ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

Similar documents
SECONDARY 600 VOLT CABLES

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

High Voltage Copper, Smooth Aluminum Shield/Sheath

ELE CTR IC UT ILI TY

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

TC-RHH/RHW-2 USE-2 Copper

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

Medium Voltage Cable. marmonutility.com

Electric Utility ENERGY PRODUCTS FOR POWER GENERATION, TRANSMISSION & DISTRIBUTION

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable


DLO. Mining Cable. Mining Cable. 2 kv

ACSR BARE ALUMINUM OVERHEAD CONDUCTOR RATED STRENGTH LBS 240 LB COIL FT AMPS (1) PARTRIDGE / , ,795

Section 11 Mining Cable

CONDUCTOR WESTERN UNITED ELECTRIC SUPPLY

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

Primary, Secondary, Post-Secondary Education Facilities

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

MEDIUM VOLTAGE

MC, THHN/THWN-2 Copper

MC or MV-105 Copper, TR-XLPE Insulated

RENEWABLE ENERGY. Alcan cable solutions

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

Multiplex Overhead Aluminum Service Cable Specification ICEA Standard S General Cable Specification Sheet #AC-0004 and #AC-0006

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

STABILOY BRAND FeeDeR SOLuTIONS

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

Type P Drilmar 125-XE Signal & Instrumentation

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

Type P Drilmar 125-XE Signal & Instrumentation

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

NEC 2014 Code Changes

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

Type MMV-WP Medium Voltage Wind Power Cable

ANSI/NEMA WC ICEA No. S Portable and Power Feeder Cables for Use in Mines and Similar Applications

Category # 1 - Overhead, Primary, & Secondary Conductors

UNSHIELDED MULTI CONDUCTOR

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE

ATHLETIC STADIUMS AND SPORTS ARENAS

TUNNELING POWER CABLES

Medium Voltage Power Cables

Outdoor Power Transmission & Distribution

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Mecklenburg County Common Code Defects

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

KALAS ENTERTAINMENT CABLE

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Automotive Cables. The Global Cable Solutions Company

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

Power & Control Cables

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

POWER. Lengths (ft) Nominal Overall Diameter. Part Number. Gauge /strands

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

SPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

HOSPITAL AND HEALTHCARE

Volume 2 Charts, Formulas, and Other Useful Information

Electrical Design/Build Guide

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

Additional Information TRADE NAME PERIWINKLE; STRANDING 7 (PHASE), 6/1 (NEUTRAL); WEIGHT 272 LB PER 1000 FT

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

BRONCO PHILATRON. Brand. Premium Flexible Power Cable WIRE AND CABLE * USA MANUFACTURER

innerduct Innerduct INNERDUCT tidbit

Connector Installation Guide Compression and Mechanical Connectors

Data sheet chainflex CFSOFT1

Easier! Faster! Safer!

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

Power & Control Cable IEC

Quintas & Quintas Group

Use the following standards for system design and performance requirements.

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

1074 Kenran Industrial Dr. St. Louis, MO Phone: Power/Distribution Cable Multiconductor

Grounding equipment COOPER POWER SERIES. Temporary Connections CA325004EN. Contents

CAAI-S 0,6/1 kv with Public Lighting

General Specifications for Lighthouse Power Pedestal

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

Filtered Kitchen Supply Packaged Ventilator

Medium Voltage Cables for PermaLife Nuclear Utility Applications

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SECTION 300 OVERHEAD SERVICE

Centrifugal Filtered Supply Roof Blowers

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

INDUSTRIAL

Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

Transcription:

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES Black Crosslinked High-Density Polyethylene (XLHDPE) with and without TRISTRIPE grounded in service wired to innovate TM

Alcan Aluminum Underground ALHIDE Single Layer Ruggedized Cables: Alcan Cable s ALHIDE Single Layer Ruggedized Cables provide superior performance and reliability when used in underground circuits where extra protection from mechanical abuse is required. The ruggedized insulation of high-density polyethylene protects the cable from possible damage that may occur during installation. Alcan s ALHIDE Cable is available in a full range of sizes to meet any 600 volt electric distribution application, as a single conductor or with one, two or three phase conductors and a neutral twisted together with no overall cover. Product Application and Features: Designed for use in electric distribution circuits not exceeding 600 volts phase to phase and may be directly buried or installed in ducts. May be used in wet or dry locations at conductor temperatures not exceeding 90 C for normal operation, 130 C for emergency overloads and 250 C under short circuit conditions. Meets or exceeds industry requirements per ASTM B-231. Manufactured in accordance with ICEA S-81-570, the industry standard for ruggedized cable. Product Construction: Alcan Single Layer ALHIDE Cables are constructed of: Three-Quarter hard drawn Class B stranded, compressed 1350 aluminum conductors. Black, weather resistant crosslinked high-density polyethylene insulation on the phase conductors and the neutral. TRISTRIPE cable features a neutral conductor that is insulated with black, weather resistant crosslinked high-density polyethylene with three continuous extruded yellow stripes located 120 apart. The identification stripes are weather resistant. In multiplexed cable assemblies, the phase conductors and neutral are twisted together with a left-hand lay not greater than 60 times the outside diameter of one phase conductor. Product Markings: Each conductor will display the following surface markings: Alcan (Plant of Manufacture), conductor size, AL XLHDPE 600V USE-2 (UL) ALHIDE (Year of Manufacture). The center aluminum wire in each stranded conductor is indent printed Alcan (Year of Manufacture). Sequential footage markings are printed every two feet on one phase conductor to ensure length measurement accuracy. USE-2 is a UL designation for a 90 C wet or dry rating. This catalog is intended to provide introductory technical data to aid the correct selection of wire and cable for permanent installation. Wire and cable products supplied by Alcan comply with the codes, standards and product specifications as indicated in this catalog. Weights and measurements are subject to manufacturing tolerances and product design changes. Consequently, Alcan does not accept responsibility for costs incurred by a purchaser as a result of weights and measurements not conforming exactly to those indicated.

ALHIDE SINGLE LAYER RUGGEDIZED CABLES Single Aluminum Conductor 600v Insulation Approx ESTIMATED WT. Ampacity* Standard Conductor XLHDPE O.D. LBS. / 1000 FT. Directly Package Code Word Size Mils Inches Aluminum Total Buried (Ft.) PRINCETON/ALHIDE 6 60 0.298 25 45 108 1000 MERCER/ALHIDE 4 60 0.345 39 64 140 1000 CLEMSON/ALHIDE 2 60 0.403 62 92 180 1000 KENYON/ALHIDE 1 80 0.473 78 121 203 1000 HARVARD/ALHIDE 1/0 80 0.512 99 146 231 1000 YALE/ALHIDE 2/0 80 0.555 125 177 263 1000 TUFTS/ALHIDE 3/0 80 0.603 157 216 299 1000 BELOIT/ALHIDE 4/0 80 0.658 198 264 338 1000 HOFSTRA/ALHIDE 250 95 0.732 234 315 368 1000 GONZAGA/ALHIDE 300 95 0.784 281 369 407 1000 RUTGERS/ALHIDE 350 95 0.831 328 422 444 1000 DARTMOUTH/ALHIDE 400 95 0.875 376 476 475 1000 EMORY/ALHIDE 500 95 0.956 469 579 540 1000 DUKE/ALHIDE 600 110 1.060 562 699 595 1000 FURMAN/ALHIDE 700 110 1.127 656 803 645 1000 SEWANEE/ALHIDE 750 110 1.159 703 855 667 1000 Duplexed Aluminum Conductor 600v Conductor Insulation Approx ESTIMATED WT. Ampacity* Standard CLAFLIN/ALHIDE 6 6 60 60 0.596 50 90 112 2000 DELGADO/ALHIDE 4 4 60 60 0.690 79 128 146 2000 Triplexed Aluminum Conductor 600v Conductor Insulation Approx ESTIMATED WT. Ampacity* Standard ERSKINE/ALHIDE 6 6 60 60 0.642 75 134 100 1000 VASSAR/ALHIDE 4 4 60 60 0.742 118 191 130 1000 STEPHENS/ALHIDE 2 4 60 60 0.830 164 250 168 1000 RAMAPO/ALHIDE 2 2 60 60 0.867 187 279 168 1000 BRENAU/ALHIDE 1/0 2 80 60 1.039 261 387 219 1000 BERGEN/ALHIDE 1/0 1/0 80 80 1.103 298 441 219 1000 CONVERSE/ALHIDE 2/0 1 80 80 1.144 330 479 249 1000 HUNTER/ALHIDE 2/0 2/0 80 80 1.196 377 535 249 1000 HOLLINS/ALHIDE 3/0 1/0 80 80 1.241 415 581 284 1000 ROCKLAND/ALHIDE 3/0 3/0 80 80 1.299 474 650 284 1000 SWEETBRIAR/ALHIDE 4/0 2/0 80 80 1.352 524 708 322 1000 MONMOUTH/ALHIDE 4/0 4/0 80 80 1.418 598 795 322 1000 PRATT/ALHIDE 250 3/0 95 80 1.497 629 850 356 1000 WESLEYAN/ALHIDE 350 4/0 95 80 1.687 859 1113 431 1000 NEWARK/ALHIDE 350 350 95 95 1.791 989 1272 431 1000 RIDER/ALHIDE 500 350 95 95 1.978 1271 1590 525 1000 WESTCHESTER/ALHIDE 500 500 95 95 2.060 1412 1745 525 1000 VILLANOVA/ALHIDE 750 350 110 95 2.325 1743 2142 615 1000 SETON HALL/ALHIDE 750 750 110 110 2.500 2120 2578 615 1000 * Ampacities are based on 90 C conductor temperature, 20 C ambient RHO-90 earth, for cables buried 36 deep, only the phase conductors carrying current, 100% load factor. DO NOT USE THESE FIGURES FOR NEC APPLICATIONS.

ALHIDE SINGLE LAYER RUGGEDIZED CABLES Triplex Aluminum Conductor 600v Impedance Data RESISTANCE INDUCTIVE REACTANCE Code Word Phase Neutral 25 C 50 C 75 C X1 ERSKINE/ALHIDE 6 6 0.6725 0.7392 0.8059 0.0337 VASSAR/ALHIDE 4 4 0.4227 0.4645 0.5064 0.0335 STEPHENS/ALHIDE 2 4 0.2655 0.2929 0.3182 0.0319 RAMAPO/ALHIDE 2 2 0.2655 0.2929 0.3182 0.0315 BRENAU/ALHIDE 1/0 2 0.1671 0.1837 0.2002 0.0301 BERGEN/ALHIDE 1/0 1/0 0.1671 0.1837 0.2002 0.0301 CONVERSE/ALHIDE 2/0 1/0 0.1326 0.1456 0.1587 0.0293 HUNTER/ALHIDE 2/0 2/0 0.1326 0.1456 0.1587 0.0293 HOLLINS/ALHIDE 3/0 1/0 0.1053 0.1157 0.1259 0.0286 ROCKLAND/ALHIDE 3/0 3/0 0.1053 0.1157 0.1259 0.0286 SWEETBRIAR/ALHIDE 4/0 2/0 0.0835 0.0917 0.1000 0.0279 MONMOUTH/ALHIDE 4/0 4/0 0.0835 0.0917 0.1000 0.0279 PRATT/ALHIDE 250 3/0 0.0706 0.0777 0.0847 0.0284 WESLEYAN/ALHIDE 350 4/0 0.0506 0.0557 0.0606 0.0275 NEWARK/ALHIDE 350 350 0.0506 0.0557 0.0606 0.0275 RIDER/ALHIDE 500 350 0.0356 0.0390 0.0426 0.0266 WESTCHESTER/ALHIDE 500 500 0.0356 0.0390 0 0426 0.0266 FAIRFIELD/ALHIDE 750 500 0.0251 0.0263 0.0286 0.0264 RHO = 90, phase spacing is phase conductor outside diameter. DO NOT USE these values for reduced wall designs. RHO = 90, phase spacing is phase conductor outside diameter. DO NOT use these values for reduced wall designs. Quadruplex Aluminum Conductor 600v Impedance Data POSITIVE SEQUENCE POSITIVE SEQUENCE RESISTANCE INDUCTIVE REACTANCE Code Word Phase Neutral 25 C 50 C 75 C X1 TULSA/ALHIDE 4 4 0.4227 0.4645 0.5064 0.0335 DYKE/ALHIDE 2 4 0.2655 0.2929 0.3182 0.0319 WITTENBERG/ALHIDE 2 2 0.2655 0.2929 0.3182 0.0315 NOTRE DAME/ALHIDE 1/0 2 0.1671 0.1837 0.2002 0.0301 PURDUE/ALHIDE 1/0 1/0 0.1671 0.1837 0.2002 0.0301 SYRACUSE/ALHIDE 2/0 1 0.1326 0.1456 0.1587 0.0293 LAFAYETTE/ALHIDE 2/0 2/0 0.1326 0.1456 0.1587 0.0293 SWARTHMORE/ALHIDE 3/0 1/0 0.1053 0.1157 0.1259 0.0286 DAVIDSON/ALHIDE 3/0 3/0 0.1053 0.1157 0.1259 0.0286 WAKE FOREST/ALHIDE 4/0 2/0 0.0835 0.0917 0.1000 0.0280 EARLHAM/ALHIDE 4/0 4/0 0.0835 0.0917 0.1000 0.0280 RUST/ALHIDE 250 3/0 0.0706 0.0777 0.0847 0.0284 SLIPPERY ROCK/ALHIDE 350 4/0 0.0506 0.0557 0.0606 0.0275 NIAGARA/ALHIDE 350 350 0.0506 0.0577 0.0606 0.0275 WOFFORD/ALHIDE 500 350 0.0356 0.0390 0.0426 0.0267 WINDHAM/ALHIDE 750 500 0.0251 0.0263 0.0286 0.0264

ALHIDE SINGLE LAYER RUGGEDIZED CABLES Quadruplexed Aluminum Conductor 600v Conductor Insulation Approx ESTIMATED WT. Ampacity* Standard TULSA/ALHIDE 4 4 60 60 0.833 157 255 119 1000 DYKE/ALHIDE 2 4 60 60 0.940 227 343 153 1000 WITTENBERG/ALHIDE 2 2 60 60 0.973 250 372 153 1000 NOTRE DAME/ALHIDE 1/0 2 80 60 1.176 361 534 198 1000 PURDUE/ALHIDE 1/0 1/0 80 80 1.236 398 588 198 1000 SYRACUSE/ALHIDE 2/0 1 80 80 1.293 455 657 226 1000 LAFAYETTE/ALHIDE 2/0 2/0 80 80 1.340 502 713 226 1000 SWARTHMORE/ALHIDE 3/0 1/0 80 80 1.404 574 797 257 1000 DAVIDSON/ALHIDE 3/0 3/0 80 80 1.456 632 867 257 1000 WAKE FOREST/ALHIDE 4/0 2/0 80 80 1.530 724 973 291 1000 EARLHAM/ALHIDE 4/0 4/0 80 80 1.589 798 1061 291 1000 RUST/ALHIDE 250 3/0 95 80 1.695 865 1166 319 1000 SLIPPERY ROCK/ALHIDE 350 4/0 95 80 1.910 1188 1536 385 1000 NIAGARA/ALHIDE 350 350 95 95 2.006 1318 1695 385 1000 WOFFORD/ALHIDE 500 350 95 95 2.237 1742 2170 437 1000 MARSHALL/ALHIDE 500 500 95 95 2.308 1883 2328 437 1000 Reduced Wall Triplex Alhide Conductor Insulation Approx NOMINAL WT. Ampacity* Standard PRATT/ALHIDE -RW 250 3/0 80 80 1.450 629 822 331 1000 WESLEYAN/ALHIDE -RW 350 4/0 80 80 1.640 859 1081 399 1000 NEWARK/ALHIDE -RW 350 350 80 80 1.726 989 1224 399 1000 RIDER/ALHIDE -RW 500 350 80 80 1.914 1271 1535 485 1000 WESTCHESTER/ALHIDE -RW 500 500 80 80 2.000 1412 1690 485 1000 Reduced Wall Quadruplex Alhide Conductor Insulation Approx NOMINAL WT. Ampacity* Standard RUST/ALHIDE -RW 250 3/0 80 80 1.638 865 1124 300 1000 SLIPPERY ROCK/ALHIDE -RW 350 4/0 80 80 1.854 1188 1488 360 1000 NIAGRA/ALHIDE -RW 350 350 80 80 1.934 1318 1632 360 1000 WOFFORD/ALHIDE -RW 500 350 80 80 2.165 1742 2099 438 1000 MARSHALL/ALHIDE -RW 500 500 80 80 2.235 1883 2253 438 1000 *Ampacities are based on 90 C conductor temperature, 20 C ambient RHO-90 earth, for cables buried 36 deep, only the phase conductors carrying current, 100% load factor. DO NOT USE THESE FIGURES FOR NEC APPLICATIONS.

Alcan Cable operates throughout North America in the U.S. as a division of Alcan Products Corporation, and in Canada as a division of Alcan, Inc. Alcan Cable has its own research and development facilities and is backed by the technology and laboratories of the Alcan Group. We re proud of our long history of providing new and innovative aluminum solutions to the many customers we serve. ALCAN CABLE Division of Alcan Products Corporation Three Ravinia Drive, Suite 1600 Atlanta, GA 30346-2133 770-394-9886 fax 770-677-2609 www.cable.alcan.com UT0009 (06/04)