NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

Similar documents
MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

INSTALLATION & MAINTENANCE MANUAL HBL

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Model: CF16MS / CF16CR / CF16WH CF28MS / CF28CR / CF28WH

MANUFACTURED IN THE UK

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Car Battery Charger Instructions for Use

LED Emergency Luminaires

LED emergency exit signage from Channel Safety Systems

Specification Sheet for 2D LED Light

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM E1, E7, S1 and S7 Recessed Ceiling Luminaires

INFRESCO-S-4kW X20034 Issue: 7

MANUFACTURED IN THE UK

Caution Wear protective glasses and turn your face away when connecting or disconnecting from the battery.

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN

Doc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

SLIM LIGHT SERIES FOR NON MAINTAINED / MAINTAINED LUMINAIRE

82V LITHIUM-ION BATTERY CHARGER GC 400

Operating Instructions

Cordless Rechargeable Saw Instructions for Use

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

25W LED Cross Bezel Bulkhead Light

EXI LED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

LEAD ACID BATTERY CHARGER

12 amp RMS Battery Charger

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

OPERATION & MAINTENANCE INSTRUCTIONS

ADDRESSABLE SELF TESTING NON MAINTAINED SPOT LIGHT EMERGENCY LUMINAIRES WITH 1 WHITE POWER LED

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

ML DA 1206 DE 3993 (I) ML DA 1206 DE 3993 (II) -16P027_ML_DA_1206_DE_3993-ML_DA_2407_DE_3993_ _DinA6_ indd

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

OPERATION & MAINTENANCE INSTRUCTIONS

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

OPERATION & MAINTENANCE INSTRUCTIONS

Elmdene International Ltd

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 600

OPERATION & MAINTENANCE INSTRUCTIONS

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Instruction Manual & Specification

PIL0478 ISSUE 01/ 07/16

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 900

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

OPERATION & MAINTENANCE INSTRUCTIONS

Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

SELF TESTING MAINTAINED EMERGENCY LUMINAIRES WITH WHITE LEDs

CORDLESS COMPRESSOR WITH SPOTLIGHT + JUMP START

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

EVO181B1. English

JUMPSTART MODEL NO: JS1000, JS1010 & JS1224 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: , & GC0514

K25000 & KD25000 Series

10W LED Die Cast Small Rectangle Bulkhead Light

Installation and Operation Instructions 10/04/13

18W Round LED Slimline Emergency Light

2 PORT MOTORISED VALVE (28 mm)

JUMPSTART MODEL NO: JS900/JS910 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC10/16

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Central Battery Systems Loadstar AC/DC Systems

SL2380. Installer s guide. Owner skit. Blind control device Battery module.

EC400 Power Control System

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

1.Safe testing IMPORTANT:

INFRESCO 2KW VARIABLE CONTROLLER Issue 3

USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No.

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

KD1E Range Potential Indicators

Model: CF16MS / CF16CR / CF16WH CF28MS / CF28CR / CF28WH

60V RECHARGEABLE LITHIUM-ION BATTERY

MIRRORLITE RECESSED EMERGENCY LIGHTING

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

SUBMERSIBLE DIRTY WATER PUMP

Индустриальное. освещение

LED FlatPanel Gen. 2. LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL. LED FlatPanel Gen. 2

Bore Hole Pump Model Nos: CBB75 CBB100 Part Nos:

3 PORT MOTORISED VALVE (22 mm)

QUICK CONNECT SYSTEM 18V POWER UNIT & DRILL ATTACHMENT Australia BDCDMT180 New Zealand

Protecta III GRP ATEX

Compact System NRGS 11-2 NRGS Original Installation Instructions English

RELAY BOX PRODUCT MANUAL IMPORTANT

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

Battery Charger JCB-FCH20LI2

EC200 ELECTRONIC CONTROL SYSTEM

Battery Charger JCB- SCH20LI.2

Operating instructions

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

EC400 / EC450 series Power Control System

Bigfoot Motorised Utility Vehicle Ba ery Operated Ride On Instruc on / Assembling Manual

Transcription:

Model No. PEL00581 NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT 1

Please read these instructions carefully before starting installation and retain for future reference. The centre page test record can be removed and kept with the building fire safety records. IMPORTANT SAFETY INFORMATION RISK OF ELECTRICAL SHOCK. ALWAYS ISOLATE THE POWER AT THE MAINS BEFORE INSTALLING OR MAINTAINING THIS EMERGENCY LIGHT. This product must be installed by a competent person in accordance with the Building Regulations and the current edition of the IET Wiring Regulations (BS7671). This product is suitable for mounting on normally flammable surfaces such as wood, plasterboard or masonry. Emergency light fittings should have their own separate mains circuit, protected with an appropriate MCB or fuse. They should not share their supply with other lighting or electrical equipment. The emergency light is suitable for connection to a 220-240V~ 50Hz. This emergency light is for indoor use only. This product will only illuminate in the event of a mains failure (non-maintained). Ensure that after installation the emergency light remains accessible for regular maintenance and testing. INSTALLATION NOTE: Before drilling any holes, check that there are no hidden obstructions behind the mounting surface such as pipes or cables. 1. Undo the four screws on the front of the main body and lift the panel off. 2. The position of the cable entry and fixing holes are marked on the case. Remove and open out as required. 3. Using the back of the product as a template, mark the position of the fixing holes on your mounting surface (see fig 1). 4. Drill the fixing holes and fit wall plugs as appropriate. 5. Secure the back of the product to the mounting surface using suitable fixings (not supplied). 6. Fit a cable gland (not supplied) into the cable entry hole. Apply silicone sealant to the fixings if moisture or weatherproofing is required. 7. Thread the supply cable through into the product and fit the cable retainer. 8. Make connection to the supply using the terminal block on the PCB. Ensure that the correct polarities are observed i.e.: Brown Live terminal L Blue Neutral terminal N 9. Write the current date on the battery pack. 10. Connect the battery pack terminal connector to the connector on the PCB. 11. Fit the front cover and restore the power supply. The green LED should light to show the battery is being charged. 12. Perform the electrical tests specified in the Wiring Regulations (BS7671). 2

Test Record Sheet on reverse PULL OUT 3

Installation, maintenance a Location: Installation date: Installed by: 20 20 2 Month Test Sign Date Sign Date S 1 Short 2 Short 3 Short 4 Short 5 Short 6 1 h 7 Short 8 Short 9 Short 10 Short 11 Short 12 3h 4

nd operation check record Installation test duration: 0 20 20 ign Date Sign Date Sign Date 5

Test Record Sheet on reverse PULL OUT 6

Lamp Connector 305mm 143mm 143mm LED Indicators Test button Circuit Board Mains Power Connector 76mm 227mm 305mm Fig 1. Dimensions Battery Connector Battery Fig 2. Internal Layout OPERATIONAL CHECKS Note: This equipment must be checked regularly in compliance with local regulation and codes of practice. For your own safety, testing should occur during the day. The LED s can be tested by pressing the TEST button on the bottom of the case. After installation, you should allow 24 hours for the battery pack to charge fully before testing. Isolate the power supply and check that the lamp remains illuminated for at least three hours. Restore the power supply. Each day: Check that the green charging LED is lit. Each month (short test): Isolate the power supply and check that the lamp remains illuminated. Record the results on the test record sheet included with these instructions. Every six months: Isolate the power supply and check that the lamp remains illuminated after 1 hour. Record the results on the included test record. Once each year: Isolate the power supply and check that the lamp is still illuminated after 3 hours. Record the results on the included test record. Please keep these test records in a safe place. A fire officer or other authorised person may want to see your record of inspection and testing. CLEANING AND MAINTENANCE Clean the product with a soft, dry cloth only. Do not use any solvents or abrasive chemical cleaners. The LED lamps in this product are non-replaceable. Changing the battery If after a routine operation check, the lamp does not remain lit for the 3 hour period, a new battery pack may be required. Change the battery pack as follows: 1. Isolate from the mains supply. 2. Remove the front panel. 3. Unplug the battery pack connector from the PCB. 4. Remove the old battery pack. 5. Write the current date on the new battery pack. 6. Secure the new battery pack in position and connect the wiring terminal connector. 7. Refit the cover. Make sure that the screws are securely fastened. 8. Restore mains power and allow to charge for 24 hours. 9. Perform the full operation check and update the test record. 7 Fuse

Changing the fuse 1. Isolate from the mains supply. 2. Remove the front cover. 3. Remove the fuse from it s housing and replace with one of the same type (240V F3A). 4. Refit the front cover making sure that it is securely screwed in place. 5. Test the operation. Self Test Fault Warning If the battery has failed, the alarm will sound at one minute intervals and the yellow indicator LED will flash. If the main lamp LED has failed, the alarm will sound every half minute and the yellow indicator will flash at about 1 second intervals. The fault alarm may be silenced using the test switch. Manual Test Operation: Press the Test button for 1 second: green LED will go off and a lamp test will run briefly. Press the Test button for 3 seconds: green LED will flash and a function test will run for 30 second simulating a mains power failure. Press the Test button for 5 seconds: green LED will flash and a battery duration test will run for 3 hours. Press the Test button for 10 seconds, all 3 LED indicators will flash 3 times and the lamps and functions will be reset to normal operation. SPECIFICATIONS Input voltage: 220-240V~, 50Hz Rated power: 5W Lamps: SMD2835 LEDs x 60pcs Luminous flux: 600 lm Continuous emergency illumination: > 3 hours (when the battery is fully charged) Battery pack: Ni-Cd, 3.6V, 6Ah Recharge time: 24 hours approx. Ambient temperature: 0-35 C Over-discharge protection: Yes Ingress protection rating: IP65 Cd INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT. When this product has reached the end of its life it must be treated as Waste Electrical & Electronic Equipment (WEEE). Any WEEE marked products must not be mixed with general household waste, but kept separate for the treatment, recovery and recycling of the materials used. Waste batteries can be returned to any waste battery recycling point which are provided by most battery retailers. Contact your local authority for details of battery and recycling schemes in your area. Made in China. PR2 9PP 8 Man Rev 1.0