Installation Guide. Single-Control Bath and Shower Trim A K K K 12021

Similar documents
Installation Guide. Single-Control Bath and Shower Trim A K T948, K T949, K T950 K 951, K 952

Installation Guide. Single-Control Bath and Shower Trim A K-T14420, K-14421, K-14422, K-T14423, K-14424, K-14426, K-14427

Installation Guide. 3-Way/2-Way Transfer Valve E

Deck-Mounted Bath Set with Diverter

Installation Guide D. Three-Way/Two-Way Transfer Valve P29513, P29514

PILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT

Installation Instructions

Basin Set INSTALLATION INSTRUCTIONS

ALTERNA DECK/BATH-MOUNT BATH FAUCET

INSTALLATION INSTRUCTIONS

Installation Guide. Engineering Excellence. Single Handle Tub & Shower Valve Set: 4020B

Installation and Maintenance Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instruction for Valve: DFPHY.ID Trim Application: Pressure Balance Tub & Shower

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions 1662SG SG.222

Installation Instructions 1662SG SG.224

Installation Instructions for Pressure Balancing Valve Set with Volume Control. Limited Lifetime Faucet Warranty

FOR TECHNICAL ASSISTANCE

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions 1662SG SG.223

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

INSTALLATION INSTRUCTIONS

Installation Instructions

Supplies Required. Teflon Tape Allen Key Wrenches Screwdriver 1/2" NPT Brass Pipe Plug Adjustable Wrench IMPORTANT!

INSTALLATION INSTRUCTIONS

SM Valve Installation

INSTALLATION INSTRUCTIONS FOR DECK TUB SETS with HAND SHOWER Valves Numbered: &

Installation Guidelines

Installation Instructions

INSTALLATION INSTRUCTIONS

THREE-VALVE BATH & SHOWER Cast Brass Body

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Guidelines

1 - S-2251 Showerhead 6 - S-2288 Showerhead AP - Anchor Plate (S-2280 Showerhead Only)

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

Installation Guidelines

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

Installation Instructions

INSTALLATION INSTRUCTIONS

Pressure Balancing Valve Shower or Tub/Shower Installation Instructions

Installation Instructions

Installation. Tools. Single Handle Kitchen Faucet With Optional Spray. Maintenance. Safety Tips. Important Points. Need Help? For Model:

E-Mini Thermostatic Valve with Shut-Off or with Positive Shut-Off 2-Way Diverter

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

Dia. S Shower Valve System. S-3500TS-X... Valve includes stops. Arm and flange 300S. Screwless escutcheon kit RTS-011, brass RTS-012, plastic

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation Instructions

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

Installation Instructions Series Series

INSTALLATION INSTRUCTIONS STUDIO S

Dia. Installation and Service Instructions. Tub-Shower Systems 3520-B, 3521-B, 3522-B Series

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

Degas. Installation and Service Instructions. Tub-Shower Systems S-5400, S-5401, S-5402 Series

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

Central Brass REPLACEMENT PARTS. MODEL NOS Three-Valve Bath & Shower Fitting Direct Sweat 8-inch Centers

SERIN MONOBLOCK LAVATORY FAUCET with

Installation Instructions

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

E-Mini Thermostatic Valve with Shut-Off or with Positive Shut-Off 2-Way Diverter

Installation Instructions Series

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Degas Shower Valve System 5400-X... Valve includes stops 5400-TRM... Trim only

SPEAKMAN. SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET

General Installation Manual for American Gas Lamp Works Gas & Electric Lamps, Torches & Posts

Installation Instructions

Installation Instructions

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

STUDIO S BATH ACCESSORIES TOWEL BARS

E-Mini Thermostatic Valve Installation Instructions - Config. 1

Second Stage Regulator - 1/4 Turn

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

Installation Instructions

INSTALLATION INSTRUCTIONS PATIENCE

Lucetta. Shower-Hand Shower System, 4605 / 4600 Installation and Service Instructions. Visual Guide Lucetta Shower-Hand Shower System, 4605 (4600)

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

Installation Instructions

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

and 1/4 TURN SECOND STAGE REGULATOR TAL 502 (L) Rev. 0 MSA 2005 Prnt. Spec (I) Mat Doc

Installation Instructions

FINISHED WALL. OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN 1651 AND 1981mm (65 AND 78) OPTION 457 mm (18") 25mm (1) MIN.

Installation Instructions

Transcription:

Installation Guide Single-Control Bath and Shower Trim K 12007 K 12014 K 12021 1031258-2-A

IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation, the installer must set the maximum water temperature setting of this valve to minimize the risks associated with scalding hazards according to ASTM F 444. Do not install a shut-off device on either outlet of this valve. The installation of any such device may create a cross-flow condition at the valve and affect the water temperature. Factors that change the temperature of the water supplied to the valve, such as seasonal water temperature changes, and water heater replacement or servicing, will change the maximum water temperature supplied by the valve and may create a scalding hazard. The pressure-balanced valve will not compensate for changes in the water supply temperature; adjust the maximum water temperature setting of this pressure-balanced valve when such changes occur. Pressure-balanced valves may not provide protection against scalding if there is a failure of other temperature-limiting devices elsewhere in the plumbing system. The installer is responsible for installing the valve and adjusting the maximum water temperature of this pressure-balanced valve according to instructions. This valve meets or exceeds ANSI A112.18.1 and ASSE 1016. If you do not understand any of the installation or temperature adjustment instructions in this document, in the United States please contact our Customer Service Department at 1-800-4-KOHLER. Outside the U.S., please contact your distributor. IMPORTANT NOTICE TO INSTALLERS! Please fill in the blanks in the information box in the Homeowners Guide and on the valve label. Retain the Homeowners Guide for future reference. 1031258-2-A 2 Kohler Co.

NOTICE TO HOMEOWNERS! This device has been preset by of to ensure a safe maximum temperature. Any change in the setting may raise the discharge temperature above the limit considered safe, and lead to scalds. Date: Tools and Materials Pipe Wrench Adjustable Wrench Strap Wrench Hacksaw or Tubing Cutter Assorted Screwdrivers Plumbers Putty Thread Sealant Hex Wrench Solder Propane Torch Thank You For Choosing Kohler Company We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before you start installation. If you encounter any installation or performance problems, please don t hesitate to contact us. Our phone numbers and web site are listed on the back cover. Thanks again for choosing Kohler Company. Before You Begin CAUTION: Risk of product damage. The valve contains plastic components. Do not apply excessive heat if you solder the valve connections. NOTE: To improve clarity, the plaster guard dome is not shown in some of the illustrations. Observe all local plumbing codes. The valve shuts off by water pressure. Do not force the handle in any direction. To turn the valve off, gently turn it to the Off position. Kohler Co. 3 1031258-2-A

Before You Begin (cont.) Flush all piping thoroughly before installing this Rite-Temp valve. Do not use plastic pipe between the Rite-Temp valve and the spout. Use 1/2 nominal copper tube or 1/2 iron pipe. Do not connect a deck-mount spout, diverter, or hand shower to the spout outlet unless you cap the shower outlet on the valve. Install a pipe or tube in a straight drop of 7 (17.8 cm) to 18 (45.7 cm) with only one elbow between the valve and the wall-mounted spout. Other types of installation may cause unsatisfactory shower performance. 1031258-2-A 4 Kohler Co.

With Stops Stem Assembly Valve Body Pressure Balancing Unit Collar Plaster Guard Stop Nut Valve Cap Less Stops Screws 72" (182.9 cm) 78" (198.1 cm) to Floor (Typical) Bath/Shower 10" Installation (25.4 cm) 4" (10.2 cm) 72" (182.9 cm) 78" (198.1 cm) to Floor (Typical) 48" (122 cm) to Floor Shower Installation 1. Prepare the Site IMPORTANT! If the bath has been installed, cover it to prevent damage to the bath surface. Rough-in Plumbing Shut off the main water supply. Install or relocate the supplies as necessary. Support Framing Determine the location of the valve, and install the support framing. 2. Prepare the Valve Carefully remove the stop nut and stem assembly, valve cap, collar, and pressure balancing unit before you apply soldering heat to the valve body. Kohler Co. 5 1031258-2-A

Plaster Guard Cold Supply Valve Body Collar Tab Shower Ell 1/2" Adapter or Solder Direct Hot Side 1/2" Copper or Pipe Shower Outlet Hot Supply Cap Assembly 180 Screws Bath Outlet Cap 3. Shower Only Valve Installation NOTE: A valve with stops is shown throughout the instruction. Installations in the United States and Canada Install the valve on the support framing so the UP mark on the valve is facing upward. Installations in Mexico Install the support framing so the UP mark on the valve is facing downward. IMPORTANT! When reassembling the pressure balancing unit to the valve body, make sure the seals in the pressure balancing unit remain in position. Rotate the cap assembly, pressure balancing unit, and collar 180 (tab on bottom), reassemble, securely tighten the screws, and reinstall the plaster guard. All Installations Install elbows and adapters (if needed) to 1/2 copper tubing or 1/2 pipe of proper length. Apply thread sealant, and connect the piping to the shower outlet of the valve. Cap the bath outlet with the cap provided. 1031258-2-A 6 Kohler Co.

72" (182.9 cm) 78" (198.1 cm) to Floor (Typical) 10" (25.4 cm) 4" (10.2 cm) Bath/Shower Installation Shower Ell 1/2" Adapter or Solder Direct Hot Side Bath Outlet 1/2" Adapter or Solder Direct 1/2" Copper or Pipe Shower Outlet 1/2" Copper or Pipe Bath Ell 4. Bath and Shower Installations NOTE: A valve with stops is shown throughout the instruction. Install the valve on the support framing so the UP mark on the valve is facing upward. Install elbows and adapters (if needed) to 1/2 copper tubing or 1/2 pipe of proper length. Apply thread sealant, and connect the piping to the bath and shower outlets of the valve. Kohler Co. 7 1031258-2-A

1/2" Adapter or Solder Direct 1/2" Copper or Pipe 1/2" Elbow Hot Supply Stem Assembly Temporary Nipple Valve Body Cold Supply Pressure Balancing Unit Collar Screws Valve Cap Stop Nut Temporary Nipple 5. Complete the Bath and Shower Installation CAUTION: Risk of product damage. The valve body contains plastic components. Remove the stop nut and stem assembly, valve cap, and pressure balancing unit before you apply soldering heat to the valve body. For copper or iron supplies, connect the water supplies to the valve body using elbows, 1/2 copper tubing or pipe, and adapters (if needed). For PVC supplies, connect the water supplies to the valve body using PVC elbows, 1/2 PVC tubing, and PVC male adapters. Use thread sealant on all threaded connections. IMPORTANT! Secure the piping to the framing. Temporarily install 1/2 nipples to the bath and shower elbows. They should extend at least 2 (5 cm) beyond the finished wall. If the inner valve components were removed for soldering, carefully reinstall them now. 1031258-2-A 8 Kohler Co.

Plaster Guard Hot Supply Tab Collar Valve Body Cold Supply 180 Screws Cap Assembly 6. Back-to-Back Valve Installation NOTE: Never install the valve body upside down. Install both valves following the valve installation instructions. The supplies to one of the valves will be reversed. Remove the plaster guard, cap, cap assembly, and collar from the valve with the reversed supply connections. Rotate the cap assembly and collar 180 (tab on the bottom). Reassemble, and securely tighten the screws. Reinstall the plaster guard. 7. Installation Checkout Install caps to the temporary bath and shower nipples. Turn on the hot and cold water supplies, and check the new installation for leaks. Remove the caps from the temporary nipples. Remove the plaster guard. Turn the valve stem to the On position, and cycle the control through its operating range. Check for leaks. For bath and shower installations, check the diverter system from spout to showerhead. Turn the valve off. Kohler Co. 9 1031258-2-A

Installation Checkout (cont.) If the valve has stops, rotate both stop adjustments fully clockwise. Turn the valve on, and verify that water does not run. Turn the valve off, and rotate both stop adjustments fully counterclockwise. Reinstall the plaster guard. 1031258-2-A 10 Kohler Co.

2-3/4" (7 cm) 3-1/2" (8.9 cm) Rough-In Depth Finished Wall Thick Wall 5-9/16" (14.1 cm) D. Plaster Guard Backing Plate Backing Plate Outer Ring Plaster Guard Valve Stem Dome Wall Material 4" (10.2 cm) D. Plaster Guard 2-3/4" (7 cm) Rough-In Depth Thin Wall 8. Finish the Wall NOTE: Thick wall installations are typically tile, plaster, marble, or similar materials. Thin wall installations are typically fiberglass and acrylic. Thick Wall Installations Provide a 5-9/16 (14.1 cm) diameter hole in the rough wall material. The flat front surface of the plaster guard must be flush with the finished wall. Complete the finished wall. Do not remove the plaster guard until instructed. Thin Wall Installation Remove the plaster guard from the backing plate. Twist the plaster guard dome to separate it from the outer ring. Discard the outer ring. Slide the dome over the valve stem. Provide a 4 (10.2 cm) diameter hole in the finished wall material. Make openings for the stops (if included) by using the holes in the backing plate as a guide. Secure the backing plate to the back of the wall material. Do not remove the dome until instructed to do so. Kohler Co. 11 1031258-2-A

Slip-Fit Spouts Copper Tube Apply plumbers putty. Threaded Spouts Nipple 1-1/2" (3.8 cm) 2-7/8" (7.3 cm) 5/32" Hex Wrench Setscrew 3-7/8" (9.8 cm) Apply plumbers putty. 9. Install the Spout CAUTION: Risk of internal seal damage. Do not use petroleum-based lubricants when installing slip-fit spouts. If the spout will not slide over the tubing, use soapy water or a silicone-based lubricant. CAUTION: Risk of internal seal damage. Loosen spout setscrew with a 5/32 hex wrench prior to installing the spout. Slip Fit Spouts Remove the temporary nipple from the bath elbow. Apply thread sealant and install a 1/2 copper tube so it extends 1-1/2 (3.8 cm) to 2-7/8 (7.3 cm) beyond the finished wall. Deburr the copper tubing. Loosen the setscrew with a 5/32 hex wrench. Apply a bead of plumbers putty or other sealant around the inlet end of the spout according to the putty manufacturer s instructions. Install the spout and carefully retighten the setscrew. Do not overtighten the setscrew. Remove all excess putty. For Threaded Spouts Remove the temporary nipple from the bath elbow. 1031258-2-A 12 Kohler Co.

Install the Spout (cont.) Apply thread sealant, and install a 1/2 nipple so it extends 3-7/8 (9.8 cm) beyond the finished wall. Apply a ring of plumbers putty or other sealant to the back of the spout according to the putty manufacturer s instructions. Apply thread sealant to the nipple, and install the spout to the nipple. Carefully tighten with a clean strap wrench. Remove excess putty. Kohler Co. 13 1031258-2-A

Shower Elbow Escutcheon Shower Arm Apply plumbers putty. Setscrew Showerhead 10. Install the Shower Arm and Showerhead CAUTION: Risk of product damage. To avoid plugging the showerhead spray outlets, use thread sealant tape on the shower arm threads. Do not use thread sealant compound (pipe dope). Remove the temporary nipple from the shower elbow. Apply plumbers putty or other sealant to the back of the escutcheon according to the putty manufacturer s instructions. Slide the escutcheon over the shower arm. Apply thread sealant tape to the shower arm, and install the shower arm to the shower elbow. Carefully tighten with a clean strap wrench. Press the escutcheon against the finished wall and secure with the setscrew. Remove all excess putty. With the showerhead off, flush out the system. Apply thread sealant tape to the shower arm and thread the showerhead to the shower arm. 1031258-2-A 14 Kohler Co.

Setscrew Tab Collar Valve Label Valve Stem O-Ring 11. Water Temperature Adjustment CAUTION: Risk of personal injury. The water temperature should never be set above 120 F (49 C). Turn the valve clockwise to the full open position and let the hot water run for several minutes. Position a thermometer in the water stream and check the temperature. For minor water temperature changes, adjust the setscrew, and recheck the water temperature. For major water temperature changes, remove the O-ring and collar from the valve stem. Slowly rotate the valve stem until the desired water temperature is reached. Reinstall the collar on the valve stem with the setscrew against the side of the tab. Reinstall the O-ring, rotate the valve stem counterclockwise to shut the water off, and recheck the water temperature. NOTE: After adjustment, complete the required information on the valve label. Kohler Co. 15 1031258-2-A

Valve Stem Plaster Guard w/dome Discard Face Plate Screw Graphic Ring Sleeve Handle Screw Insert Washer Plug Button 12. Install the Face Plate Remove and discard the plaster guard and/or dome, if installed Install the face plate onto the valve. Secure with two screws. Do not overtighten. Install the graphic ring to the face plate, and rotate it clockwise to lock it in place. Rotate the valve stem fully counterclockwise. Fit the sleeve onto the valve. Align the handle, and press the handle and insert firmly onto the valve stem. Secure the handle with a washer and screw. Press the plug button firmly into place, aligning the tab with the notch in the handle. 13. Complete the Installation Turn the valve fully counterclockwise to the off position. Remove the aerator assembly from the spout by turning it counterclockwise. Turn on the main water supply. Turn the valve to the center and run water for approximately one minute to flush the system. Check all connections for leaks. Reinstall the aerator. 1031258-2-A 16 Kohler Co.

1031258-2-A

1031258-2-A

1031258-2-A

USA:1-800-4-KOHLER kohler.com 2004 Kohler Co. 1031258-2-A