94D / 94F / 94M / 96M

Similar documents
JUMO flowtrans DP R. Meter run R01 and orifice plate R02. Applications. Brief description. Special features. Customer benefits.

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

Datasheet Rev.3 Feb 2015 Venturi tube

Datasheet Rev.1 Feb 2014 High precision flowmeter

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC

ORIFICE PLATE flow meters

Rosemount 1195 Integral Orifice Primary Element

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

EMCO Primary Elements for Flow Measurement

STEEMCO Flowmeter for Steam

KIRLOSKAR ROMAK PUMP - RMK ISO 2858 / DIN EN / ISO 5199

Instrumentation Products F Series Manifolds and Multi-Way Cocks

Type. Type 457, , 458. Flanged Safety Relief Valves spring loaded

TRANSMITTER ATTACHES TO THIS SURFACE

ORIFICE PLATES, FLANGES FLOW NOZZLES, VENTURI TUBES AND ACCESSORIES

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

Type 459. Type 459. Available designs. Cap H2. with bushing 19. Lock nut. Bonnet. Outlet flange 2.4 Outlet adaptor 2.1. spacer.

Orifice plates and nozzles. Flow measurement using differential pressure

SPIRAL WOUND GASKETS (SWG)

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Square Edged Concentric

PFS-FN FEATURES: * ASME & ISO RECOGNIZED * * WIDELY ACCEPTED TEST STANDARD * * RELIABLE PERFORMANCE HISTORY * * ACCURATE METERING SOLUTION *

Differential Pressure Gauges (701P Series)

485 - NC NO/DA DN

STEEMCO-MAS Flowmeter for Steam

IFOA Integral Flow Orifice Assembly

FLANGES PRODUCT: STANDARD FLANGE CLASSIFICATION: PRESSURE CLASS CLASIFICATION:

Specialties in Steam Flow Measurement

ORIMAS Mass Flowmeter

PNEUMATICALLY ACTUATED 2-WAY

RHM015. Ultimate Performance Coriolis Mass Flow Meter for Critical Ultra Low Flow Applications. Features. Applications. Benefits

Bore (B) Pitch Diam. Drilling Template Flanges (1) Diam of Diam of. Groove. Neck D X G A Raised Face Raised Face P Raised face

RAIMONDI. High pressure forged globe valves to guarantee the pressure envelope integrity on harsh services.

IntraNozzle Flow Nozzle Type: IFN

Rosemount DP Flowmeters and Primary Elements

Averaging Pitot Tube Flowmeter Catalogue ED IN AUSTRALIA

Spring loaded Thermal Relief Safety Valves, manufacturers standard Medium and high pressure

Tri-Clamp ferrules & blanks

Special Documentation Mechanical accessories for pressure measuring devices

CHAMPION WAFER CHECK VALVES SIZE RANGE 2" 72" ASME CLASS MATERIALS: IRON CARBON STEEL STAINLESS STEEL ALUMINUM BRONZE ALLOY 20 MONEL NICKEL

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

Type 427, 429. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E

Block & Bleed Valve.

Compac-Noz Valves High Performance Non-Slam Check Valves

Weld-Ring Gaskets. Weld-Ring Gaskets. Absolutely leak proof gasketing. Characteristics and Advantages Page 1. Hollow Lip Weld-Ring Gaskets Page 2

ALC-3 BUTTERFLY VALVES NOMINAL PRESSURE NOMINAL SIZE MATERIALS CONNECTIONS DESIGN. ANSI Class PN DN

Materials : Carbon steel or stainless steel

Type 459. Type. 459 Safety Relief Valves spring loaded

Type 431, 433. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E

SV80H Safety and Relief Valves

TBV Valve Instrument Connection Systems Quality measurement technology, proven close-coupled mounting practices, and integrated hardware for optimal

Type 431, 433. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E

IBV Series C-LF2 Carbon Steel Inverted Bucket Vertical Steam Trap

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

RHM08. Versatile Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM04. Compact Coriolis Flow Sensor With Enhanced Performance. Features. Applications. Benefits

304C. Valve Group. Series Farris Engineering Pressure Relief Valves

Honeywell EN REV. 2 09/2014 Page 1 of 10 Specification

FAR51. Insertion adapter with venting element Universal insertion adapter for existing flange nozzles, suitable for high temperature applications

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

Standard Duty Que - Temp Desuperheater Model: 33 / 43

Type 455, 456. Type 455, 456. Flanged Safety Relief Valves spring loaded

Product Data Sheet , Rev KA April 2010 Rosemount 1495 and Contents

YARWAY NARVIK MODEL 33/43 STANDARD DUTY QUE-TEMP DESUPERHEATER

BLOCK & BLEED VALVE. High Technology Valve & Fitting Series.

Differential Pressure - Primary Flow Element Wedgemeter II Series WM: C/F/P

Item Component Remarks Type 4393 Type ), SA Vulcanized soft seal disc SA L SA L

Inductive conductivity meter

/ Catlg.Val Nacional-16pg-ING indd 1 7/11/16 11:13

Praher S4 Ball Valve. manual valves. Materials. Sizes. Pressure Rating. Features. Connections. Valve Dimensions. Actuation.

Praher S4 Ball Valve. manual valves. Materials. Sizes. Pressure Rating. Features. Connections. Valve Dimensions. Actuation.

DOUBLE-ECCENTRIC BUTTERFLY VALVES TYPE L32.7

Maintenance-free shut-off globe valves PN 25/40 DN Standard variants. Application. Operating data. Materials

Safety Relief Valves Commanche Techmatic Controls

Champion Valves, Inc. DUAL DISC SPRING LOADED WAFER CHECK VALVES

Valves and manifolds

Flow Measurement SITRANS F O delta p - Primary differential pressure devices

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

Masoneilan * Pressure Regulators Steam, Gas or Liquid Service Models 525 and 526

RAIMONDI. High pressure forged check valves recommended to prevent flow reversal in severe applications.

Type 437. Type 437. Available designs. Cap H2 Adjusting screw with bushing. Axial needle 69 beering. Lock nut. Spring plate. Spring plate. Pin.

YARWAY NARVIK STANDARD DUTY A.T.-TEMP DESUPERHEATER MODEL 38/48

Rosemount Manifolds. Rosemount Manifolds. Product Data Sheet , Rev LA Catalog Contents

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits

Type. Facts. Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E

Technische Dokumentation Technical Documentation

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

Electromagnetic Flow Meter Owner s Manual HARDWARE

Instrument Valves and Manifolds

Globe valves Shut-off check valve 200 AE/BE PN DN Globe valves Lift check valve 240 MT PN DN 10-50

Maxifluss Rotary Plug Valves VETEC Types 73.3/M and 73.7/M

T EN Type 3349 Aseptic Angle Valve With USP-VI diaphragm

FLEXWOUND METALLIC AND SEMI METALLIC GASKETS

Pressure Measurement Remote seals for transmitters and pressure gauges

HOKE Monoflange Valves. Primary Isolation Valves

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

AVK (WWE) BUTTERFLY VALVE DN 50 to DN (EVTLS)

T-Bar Bonnet. Monoflanges STANDARD OPTIONS. O.S.&Y. Bonnet (firesafe) Gas Solution Bonnet. Anti-Tamper Bonnet

Hopkinsons CONTENTS SCHEDULE OF SHELL BOILER MOUNTINGS. Hopkinsons. Safety Valves 5. Boiler Stop Valves 17. Feed Check Valves 18. Blowdown Valves 20

Transcription:

94D / 94F / 94M / 96M - 2016 1 Meter Runs MBL 500 Application Meter runs combine inlet and outlet piping with a flow element which is used for flow measurement of one-phase aggressive and non-aggressive gases, steam or liquids, especially for small pipe diameters up to DN 50 (2"). Due to the integrated in- and outlet pipes flow disturbances can be reduced. For steam and gas measurements we can include additional taps in the inlet and outlet for pressure and temperature compensation. In small pipelines the influence of flow disturbances on the measurement is significant. Our inlet and outlet pipes are manufactured to fulfill all requirements which are defined in the calculation standards. This ensures minimum measurement uncertainties. Additionally, the major part of the necessary inlet and outlet pipe length is already included in our design. Standard Installation Lengths L (similar to DIN 19205) diameter 10 3/8 15 ½ 20 ¾ 25 1 32 1 ¼ Different installation lengths are also possible. 40 1 ½ L (mm) 400 550 700 900 1100 1300 1500 1600 1800 2200 2700 3200 4000 L1 (mm) 230 380 500 650 800 1000 1200 1250 1400 1700 2000 2400 3000 L2 (mm) 170 170 200 250 300 300 300 350 400 500 700 800 1000 50 2 65 2 ½ 80 3 e.g. orifice plate 100 4 125 5 150 6 200 8 Measuring Uncertainty ca. 0,5% - 1,5% of the discharge coefficient C, depending on the use case Pressure Loss The pressure loss depends on the diameter ratio β (d/d) and amounts to ca. 30-80% of the differential pressure.

94D / 94F / 94M / 96M - 2016 2 Installation and Facing Flanged ends: according to EN 1092-1: flat (Form B1 and B2) groove (Form D) female (Form E) according to ASME B16.5: flat (RF and SF) groove (small/large) female (small/large) RTJ female or according to other flange standards specified by the customer. Weld ends: Weld connection according to the pipe dimensions of the customer. Bore Diameter "d" The calculation of the bore diameter is based on the supplied process data. All relevant standards and regulations will be considered. The calculation is part of the scope of supply. Pressure Taps Pressure taps will be designed according to customer requirements. Typical tap designs are: plain ends for fittings butt weld ends threaded ends flanged ends compact taps according to IEC 61518 The typical tapping length is ca. 100 mm. Installation For mounting between flanges according to EN 1092-1 / ASME B 16.5 or other standard such as DIN, JIS or BS. The pipe may be positioned horizontally, vertically or sloped.

94D / 94F / 94M / 96M - 2016 3 Calibration If the requirements dictate the highest measurement quality possible we can perform a calibration of the meter run. This means we determine the flow coefficient "C" empirically on a test bench. Marking Tag no. of flow element Pressure rating "PN" Pipe inner diameter "D" Bore diameter "d" Material, direction of flow and tagging of pressure tappings with "+" and " " Materials The following table shows a selection of typical materials utilized for meter runs. The material is chosen based on process medium, pressure and temperature. Other materials are possible as well. Carrier ring/flanges short name DIN material no. ASTM / UNS non-alloy steels heat resistant/alloyed steels stainless steels high corrosion-resistant alloys plastics P250GH (C22.8) 1.0460 ~ A105 P265GH (HII) 1.0425 - A105 ~1.0432 A105 A516 Gr.60 ~1.0436 A516 Gr.60 16Mo3 1.5415 - X2CrNiMo17-12-2 1.4404 316L X6CrNiMoTi 17 12 2 1.4571 316Ti Hastelloy C276 2.4819 N 10276 Monel 400 2.4360 N 04400 Polyvinylcloride PVC Polyvinylcloride Polyethylene PE Polyethylene PVDF (GRP 25%) PVDF PVDF Teflon (GRP 25%) PTFE PTFE Orifice plate stainless steels high corrosion-resistant alloys Pipe / Taps non-alloy steels X2CrNiMo17-12-2 1.4404 316L X6CrNiMoTi 17 12 2 1.4571 316Ti Hastelloy C276 2.4819 N 10276 Monel 400 2.4360 N 04400 S235G2T 1.0308 - P235G1TH 1.0305 - A106 Gr.B ~1.0405 A106 Gr.B

94D / 94F / 94M / 96M - 2016 4 Quality Control Manufacture and Test work is done according to the relevant codes and standards such as AD 2000, EN 13480, ASME Codes (without stamp) or customer specifications. Inspection certificates according to EN 10204 3.1 and 3.2. may be furnished. Special inspections are also possible. Accessories Pipe flanges, bolts/nuts, gaskets for installation, tap valves, condensate pots, manifolds, mounting accessories, calibration may be offered for additional charges. Designs Design 94D Our standard design for flow measurement in small pipe diameters. It includes a ring chamber and an orifice plate which can be switched easily. The inlet and outlet pipes form a unit with the ring chambers. An integral design with manifold and DP transmitter is possible. Design 94F Meter run design with a flow element mounted between flanges, e.g. an orifice plate with taps or a nozzle. Taps are located in the flow element or in the in-/outlet pipe. Design 94M Meter run design with an orifice plate BLS 100 mounted between orifice flanges according to ASME B16.36 or DIN 19214. Design 96M Meter run design with a weld-in flow element suited especially for high pressure applications.

94D / 94F / 94M / 96M - 2016 5 Meter Run Design 94D Meter run 94D are flow elements with ring chamber tapping. The orifice plate can be replaced easily. Possible orifice plate types are square edge concentric quarter circle nozzle bidirectional plate with conical entrance double cone according to the relevant standards (ISO 5167, ASME MFC-3M etc.). The plate type is chosen based on the specific process conditions. The meter runs are delivered completely mounted. The end connections can designed as flange ends or weld ends. The inlet and outlet pipes form a unit with the ring chambers. This results in the lowest flow disturbance possible as any sudden change in the pipe inner diameter is avoided. The meter run can be adapted to different process conditions easily by switching the removable orifice plate. Compact design (MBL 500 K): External influences such as temperature, vibrations, differences in elevation etc. can be avoided. Installation costs are reduced because there is no need for tap pipes to be installed on site. We can deliver a meter run complete with manifold and the customer's transmitter, ready for direct usage. Nominal Diameter DN 10 to DN 80 / DN 3/8 to DN 3 Pressure Rating PN 6 to PN 40 / 150# to 300# (for higher pressure ratings please use design 96M)

94D / 94F / 94M / 96M - 2016 6 Meter Run Design 94F The design 94F combines a meter run with any flow element which can be mounted between flanges, e.g. ring chamber orifice plates BLA 200 or orifice plates with single bore taps BLB 300. Another solution could be an orifice plate without taps BLS 100 where the pressure taps are located in the meter run pipe. Please see the relevant brochures E92 (BLA 200), E93 (BLB 300) or E91N (BLS 100) for more information on the flow elements. By choosing an appropriate flange facing such as male/ female or groove/ tongue the flow element can be aligned perfectly centric. The meter run will be delivered completely mounted, ready for installation on site. We may offer flanged end connection or weld end connection. Installation disturbances, e.g. sagging of the weld seam root, can be avoided by subsequent mechanical processing. Additionally, we can ensure the correct mounting of the flow element before shipping it to the installation site. Nominal Diameter DN 50 to DN 250 / DN 2 to DN 10, other sizes are possible. Pressure Rating PN 6 to PN 100 / 150# to 600# (ASME) Meter run with a ring chamber orifice plate Meter run with an orifice plate and "D and D/2 pressure tappings"

94D / 94F / 94M / 96M - 2016 7 Meter Run Design 94M The design 94M combines a meter run with orifice flanges (e.g. according to DIN 19214 or ASME B16.36) and an orifice plate BLS 100. Please check the brochure E91N/F for more information on orifice plates and orifice flanges. The meter run will be delivered completely mounted, ready for installation on site. We may offer flanged end connection or weld end connection. Installation disturbances, e.g. sagging of the weld seam root, can be avoided by subsequent mechanical processing. Additionally, we can ensure the correct mounting of the flow element before shipping it to the installation site. Nominal Diameter DN 10 to DN 200 / DN 1/2 to DN 8, other sizes are possible. Pressure Rating PN 6 to PN 400 / 150# to 2500# (ASME)

94D / 94F / 94M / 96M - 2016 8 Meter Run Design 96M Meter run design 96M are flow elements with welded ring chamber tappings. This design is well suited for high pressure and high temperature applications. The orifice plate can be manufactured as square edge concentric bidirectional quarter circle nozzle plate with conical entrance double cone according to the relevant standards (ISO 5167, ASME MFC- 3M etc.). The plate type is chosen based on the specific process conditions. Generally, we offer weld end connections. The welded construction avoids any leakage of the flow medium. All welding seams can be analyzed via radiographic examinations or other NDE procedures. Installation disturbances, e.g. sagging of the weld seam root, are avoided by subsequent mechanical processing. Nominal Diameter DN 10 to DN 50 / DN 1/2 to DN 2, other sizes are possible. Pressure Rating PN 63 to PN 400 / 600# to 2500# (ASME), lower pressure ratings are possible on request. Installation This meter run design can be directly welded to the pipe on site. If necessary, we can make respective adjustments to the end connection dimensions.