Megohmmeter Test Probe

Similar documents
BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Digital/Analog Megohmmeter Model 1026 USER MANUAL

MEGOHMMETER. User Manual

K100 K110 AEMC INSTRUMENTS ENGLISH. User Manual. n DC/AC MICROPROBE. Model K mv/ma OFF. DC/AC MicroProbe

Digital/Analog Megohmmeter Model 1026

362 Clamp Meter. Users Manual

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Model 1672, 1673 Triple Output Power Supply

Phase Sequence Tester

Go to to register your product and find more information.

Users Manual. Phase Rotation Indicator

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Model 1693, 1694 Switching DC Power Supply

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

Switching DC Power Supply

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

SLA Battery Capacity Analyzer

233 True-rms Remote Display Digital Multimeter Safety Information

Cable Length Meter INSTRUCTION MANUAL

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

323/324/325 Clamp Meter

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

PY-11 Voltage & Continuity Tester

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

302+/303 Clamp Meter. Users Manual

3-Year Limited Warranty. See the Users Manual for the full warranty.

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

362 Clamp Meter. Users Manual

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

KMP Insulation-Continuity Tester. Users Manual

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Digital Transformer Ratiometer

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Model P772 Conductivity Meter. User Manual

KSZ 10B Current Probe Calibrator. Instruction Manual

190M. Medical ScopeMeter. Safety Information

2-Year Limited Warranty. See the Users Manual for the full warranty.

User's Manual. Earth Ground Resistance Tester. Model Introduction

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

i400s Calibration Information Introduction

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

OPERATING INSTRUCTIONS

DT304. Digital Temperature Logger INSTRUCTION MANUAL

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

OPERATING INSTRUCTION

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

This manual covers the following model:

365 Detachable Jaw True-rms Clamp Meter

Calibration Manual. Detachable Jaw True-rms Clamp Meter

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

i3000s/i2000 Flex AC Current Probe

KSZ 100B Current Probe Calibrator. Instruction Manual

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

373 Clamp Meter. Users Manual

ULT800. TEE Transducer Leakage Current Tester. Users Guide

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

INSTRUCTION MANUAL DM5B Fax: (503)

IAQ-CALC TM Indoor Air Quality Meter

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

FD Conveyor for FD 260 Tabber

BroadBand PowerShield. 20 AHr Battery. User Manual

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

Visit us at

Triple Output Power Supply

Hybex Microsample Incubator

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

OPERATION AND MAINTENANCE

Indoor Air Quality Meter

IAQ-CALC TM Indoor Air Quality Meter

ELECTRICAL. Moisture Meter User Guide

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING


AXD 530 MicroManometer

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Installation manual wall-mounted distributor

MV Series Motors Operation & Parts Manual

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

CTFRP Series Power Supplies

Model G14SD Vapor Management System

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

Operation Manual. Battery Charger ARTIKEL CHF CHF-4803

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

Transcription:

Megohmmeter Test Probe User Manual ENGLISH www.aemc.com CHAUVIN ARNOUX GROUP

Copyright Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All rights reserved. No part of this documentation may be reproduced in any form or by any means (including electronic storage and retrieval or translation into any other language) without prior agreement and written consent from Chauvin Arnoux, Inc., as governed by United States and International copyright laws. Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA Tel: (800) 945-2362 or (603) 749-6434 Fax: (603) 742-2346 This documentation is provided as is, without warranty of any kind, express, implied, or otherwise. Chauvin Arnoux, Inc. has made every reasonable effort to ensure that this documentation is accurate; but does not warrant the accuracy or completeness of the text, graphics, or other information contained in this documentation. Chauvin Arnoux, Inc. shall not be liable for any damages, special, indirect, incidental, or inconsequential; including (but not limited to) physical, emotional or monetary damages due to lost revenues or lost profits that may result from the use of this documentation, whether or not the user of the documentation has been advised of the possibility of such damages. Chauvin Arnoux, Inc and AEMC are registered trademarks of AEMC Instruments.

Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable to international standards. We guarantee that at the time of shipping your instrument has met its published specifications. An NIST traceable certificate may be requested at the time of purchase, or obtained by returning the instrument to our repair and calibration facility, for a nominal charge. The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer. For recalibration, please use our calibration services. Refer to our repair and calibration section at www.aemc.com. Serial #: Catalog #: Model #: Please fill in the appropriate date as indicated: Date Received: Date Calibration Due: Chauvin Arnoux, Inc. d.b.a AEMC Instruments www.aemc.com

Thank you for purchasing the Megohmmeter Test Probe. This accessory is designed for use with the Megohmmeter Model 652x/653x series; and with Installation Testers C.A 6116N, and C.A 6117. For best results from your probe and for your safety: read these operating instructions carefully comply with the precautions for use WARNING, risk of DANGER! Refer to these instructions whenever this danger symbol appears. CAUTION! Risk of electric shock. The voltage at the parts marked with this symbol may be dangerous. Equipment protected by double insulation. Ground/Earth. Battery. Information or useful tip. Indicates conformance with European directives, in particular LVD and EMC. Indicates that in the European Union this product must undergo selective disposal in compliance with Directive WEEE 2002/96/EC. This equipment must not be treated as household waste. Definition of Measurement Categories (CAT) CAT II Measurement Category II corresponds to measurements taken on circuits directly connected to low-voltage installations. Example: power supply to domestic electrical appliances and portable tools. CAT III Measurement Category III corresponds to measurements on building installations. Example: distribution panel, circuit-breakers, machines or fixed industrial devices. CAT IV Measurement Category IV corresponds to measurements taken at the source of low-voltage installations. Example: power feeders, counters and protection devices. iv Megohmmeter Test Probe

Precautions for Use This accessory complies with safety standards IEC61010-1, and IEC61010-031 for voltages up to 600V in CAT IV. Failure to observe the following safety instructions may result in electric shock, fire, explosion, and damage to the instrument and installation. The operator and/or the responsible authority must carefully read and clearly understand all precautions to be taken in use. Sound knowledge and a keen awareness of electrical hazards are essential when using this accessory. If you use this accessory other than as specified, the protection it provides may be compromised, thereby endangering you. Do not use the accessory on networks on which the voltage or category exceeds those mentioned. Do not use the accessory if it seems to be damaged, incomplete, or poorly closed. Before each use, check the condition of the insulation on the leads and housing. Any item of which the insulation is deteriorated (even partially) must be set aside for repair or scrapping. Use personal protection equipment as appropriate. Keep your fingers behind the physical guard. All troubleshooting and metrological checks must be performed by competent and accredited personnel. Megohmmeter Test Probe v

Table of Contents 1. INTRODUCTION...1 1.1 Receiving Your Shipment...1 1.2 Ordering Information...1 1.3 Description...2 2. OPERATION...3 3. SPECIFICATIONS...5 3.1 Power Supply...5 3.2 Environmental...5 3.3 Mechanical...5 3.4 Safety...5 4. MAINTENANCE...6 4.1 Cleaning...6 4.2 Replacing the Battery...6 4.3 Limited Warranty...7 vi Megohmmeter Test Probe

1. INTRODUCTION 1.1 Receiving Your Shipment Upon receiving your Megohmmeter Test Probe product package, ensure the contents are consistent with the packing list. Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, providing a detailed description. Save the damaged packing container to substantiate your claim. 1.2 Ordering Information Megohmmeter Test Probe (600V CAT IV)...Cat. #2155.75 Includes one 9V alkaline battery, user manual, and verification certificate. Order Accessories and Replacement Parts Directly Online Check our Storefront at www.aemc.com for availability Megohmmeter Test Probe 1

1.3 Description 1 2 3 FRONT BACK 6 4 5 Detachable test tip Ø 2mm which can be stored on the back of the 1 probe. 2 Light to illuminate the measurement point. 3 Special 3-pin plug. 4 Button on back side of probe to turn light ON/OFF. 5 Shielded cord. 6 Button to start a test. 2 Megohmmeter Test Probe

2. OPERATION Do not use the probe on an electrically live system. The test probe plugs into: terminal of the megohmmeter MΩ terminal of the installation tester You can hold the probe in one hand and the instrument in the other, and press the probe s yellow (TEST) button to take a measurement. To use the remote probe: 1. Connect the probe to the instrument via the appropriate terminal. Then connect the red safety lead supplied with the instrument to the + or COM terminal, depending on instrument type. The symbol (for megohmmeters) or (for installation testers) appears on the instrument LCD. 2. Connect the red lead to the frame ground of the system under test. Then touch the test probe measurement tip to the other side of the system (see below). 600V CAT IV L1 L2 > 700V L3 GND In dark conditions, you can illuminate the measurement tip by pressing the button on the back side of the probe. Megohmmeter Test Probe 3

3. Press the probe s yellow button to start the measurement. Keep the button pressed until you obtain a stable reading. 4. After the measurement is taken, release the yellow button. Then remove the probe from the system under test and disconnect the probe from the instrument. For details about taking measurements with your instrument, refer to its user manual. 4 Megohmmeter Test Probe

3. SPECIFICATIONS 3.1 Power Supply The probe is powered by a 9V alkaline battery (type 6LF22). The nominal operating voltage is between 7 and 10V. The battery is needed only to power the light; the probe is otherwise fully functional without the battery. Battery life is 100 hours of continuous operation. 3.2 Environmental Indoor use Operating range: 32 to 113 F (0 to 45 C) and 10 to 90% RH Storage range (without battery): -40 to 158 F (-40 to 70 C) and 10 to 90% RH Pollution Degree: 2 Altitude: <6562 ft (2000m) 3.3 Mechanical Dimensions: (L x W x H): 6.1 x 1.85 x 1.93 (155 x 47 x 49mm) Cord: 6.56 ft (2m) Weight: approximately 7.76 oz (220g) Ingress protection: IP 53 according to IEC 60 529 IK 04 according to IEC 50102 Drop test: according to IEC 61010-1 3.4 Safety Electrical safety according to IEC 61010-031 (Ed. 2 of 2002). Megohmmeter Test Probe 5

4. MAINTENANCE Use only factory specified replacement parts. AEMC will not be held responsible for any accident, incident, or malfunction following a repair done other than by its service center or by an approved repair center. 4.1 Cleaning Disconnect all leads from the probe and turn it OFF. Use a soft cloth, dampened with soapy water. Rinse with a damp cloth and dry quickly with a dry cloth or forced air. Do not use alcohol, solvents, or hydrocarbons. 4.2 Replacing the Battery The battery must be replaced when the probe light is too dim to provide adequate illumination. 1. Disconnect all leads and probes from the instrument. 2. Using a screwdriver, remove the two fastening screws. 3. Replace the old battery with a new one (9V alkaline battery, type 6LF22). Used batteries must not be treated as ordinary household waste. Recycle them appropriately. 4. Position the new battery in the designated slot, taking care to ensure correct polarity 5. Close the case and ensure that it is closed completely and correctly. 6. Replace the two fastening screws. 6 Megohmmeter Test Probe

4.3 Limited Warranty The Megohmmeter Test Probe is warranted to the owner for a period of two years from the date of original purchase against defects in manufacture. This limited warranty is given by AEMC Instruments, not by the distributor from whom it was purchased. This warranty is void if the probe has been tampered with or abused, or if the defect is related to service not performed by AEMC Instruments. Full warranty coverage and product registration is available on our website at www.aemc.com/warranty.html. Please print the online Warranty Coverage Information for your records. What AEMC Instruments will do: If a malfunction occurs within the warranty period, you may return the probe to us for repair, provided we have your warranty registration information on file or a proof of purchase. AEMC Instruments will, at its option, repair or replace the faulty material. REGISTER ONLINE AT: www.aemc.com Warranty Repairs What you must do to return an Instrument for Warranty Repair: First, request a Customer Service Authorization Number (CSA#) by phone or by fax from our Service Department (see address below), then return the instrument along with the signed CSA Form. Please write the CSA# on the outside of the shipping container. Return the instrument, postage or shipment pre-paid to: Ship To: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA Phone: (800) 945-2362 (Ext. 360) (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 E-mail: repair@aemc.com Caution: To protect yourself against in-transit loss, we recommend you insure your returned material. NOTE: You must obtain a CSA# before returning any instrument. Megohmmeter Test Probe 7

Notes: 8 Megohmmeter Test Probe

Notes:

CHAUVIN ARNOUX GROUP 08/18 99-MAN 100436 v2 Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA Phone: (603) 749-6434 Fax: (603) 742-2346 www.aemc.com