Table of Contents. ENGLISH Contents Page

Similar documents
Ex m Solenoid Operator Type 0519

GENUINE REAR SPOILER

Operating instructions K- Control 4960, 4965, Always on the safe side.

Operating manual GA 250AL GA 400AL. Edition 07 / Automatic Airless Spraygun. II 2GX (Atex 95)

Operating instructions

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

RipTide. Brewing Pump. Assembly, Operation, & Maintenance

Operating Manual for FINE-SPRAY gun W 3/FZ-Duo

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

INSTRUCTION MANUAL MAGNA RAIL

BluePRESSLine. Size 1-S Size 2-S

English. Instruction and operation manual S 212. Dew point sensor

6L Oil-less Air Compressor 53103

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

TM-1620 OPERATING INSTRUCTIONS AND OWNERS MANUAL

IVET-D 16A / 3,5 kva IVET-D 30A / 7,5 kva IVET-D 16A / 3,5 kva - MT

Combined Ventilation Controller RVWS-T-224HA

INSTALLATION RULES for SCS/SENSOR Pt100

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Spare Parts Piezas de repuesto Pièces de Rechange. Ersatzteile

Swing Piston Compressors and Vacuum Pumps

TBE-700. Operation, Safety and Maintenance Manual. Stainless Steel Weld Cleaning System. Ensitech Pty Ltd

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Solenoid Operator 0513 / 1213

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

3 740 Wrist strap + shoe tester

Sprint Mag Hover. 40x50 cm OPERATOR S MANUAL.

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Operating Manual. Hand Welding Unit HW35-3. with generator SL35. English

Remote engine start INSTALLATION INSTRUCTIONS

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

Thermistor Thermometer MODEL NO

DC Master 24/ A

Oil-free piston compressors KK and piston vacuum pumps KV

WORKHORSE. Assembly / Operation Instructions / Parts

Start-up instructions

MR 3001, MR 3001 K, MR 3001 K8 MR 3002, MR 3002 S8 HG 3001, HG 3001 K

Translation of the Original operating instructions Lifting device Z 70 /...

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Assembly and Maintenance Manual Type ASNU

Tension Meter. PT Series. Instruction Manual PT-100-L. Valid as of: Please keep the manual for future reference!

Bedienungsanleitung Schüttler KM. Operating Instructions Shaker KM. Mode d emploi Agitateur KM KM 2 KM 2 AKKU KM CO 2 VERSION 04 / 2016

OPERATING INSTRUCTIONS

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

TOSHIBA Thermal Printer B-852-R SERIES. Maintenance Manual. Document No. EO Original Mar., 2006 (Revised ) PRINTED IN JAPAN

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Exchange of rollers from the XTS-Mover

Solenoid Operator 0516 / 1216

OPERATING INSTRUCTIONS. LEISTER Varimat V Hot Air Automatic Welding Machine

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

OPERATING INSTRUCTIONS. Operating Instructions

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

Service information. How to avoid equipment failures with preventive maintenance measures. 1. General information 08/2017

Operating manual. ba55321de LRD Conductivity measuring cell to be installed in pipelines. ba55321de01 12/00

INSTALLATION AND OPERATION MANUAL

WARRANTY...1 NOTICE INTRODUCTION USE...8

INSTRUCTION MANUAL Skin 2

Service - Safety Manual

INSTALLATION INSTRUCTIONS

Installation and Operating Instructions Magnetic Vibrator MR 1

VECTRIX VX-2 SERVICE MANUAL. Version 1.0/May 2011 VECTRIX, LLC

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

RESOL SBS 1000 * * Connection Operation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Operating Instructions for Your Cobra 300 Watt POWER INVERTER M ODEL CPI 300. Nothing comes close to a Cobra

Cateye Ergometer. Belt Drive, Automatic Type. Service Manual. Model EC-1200/EC-1600/EC-3600/EC-3700/EC-C400/EC-C400R Ver.

Operating Instructions Type MPT 53

Stevens Type A/F Encoder. For Stand-Alone Encoder Part # AND Encoder Attachment Part # INSTRUCTION 90044

Safety instructions. Always... Never... Fire hazard! Dear customer,

Armon Edero. User manual

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Shower System. Dual Head INSTRUCTION GUIDE

b3c OPERATING MANUAL (GB) 9260(A) (A) 9360 Compacts scales 9260 (A) Ver 2014 EN September BC

Operator s Manual. Nitro 1000 Nitro 1000X. Nitro 750 Nitro 750X. September REV0

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Operating Instructions K Always on the safe side.

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

User Manual Hoof trimmingcrush:sa0010. Version: User manual. Hoof trimming crush SA0010

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

Dawson DAN100. Analog Multimeter User s Manual

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Hybex Microsample Incubator

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

INSTALLATION INSTRUCTIONS

Assembly instructions

Rev ENGLISH..2

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

POST LANTERN ITEM # MODEL #39434 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

OWNER S MANUAL Please read this manual before operating your power supply

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Diaphragm Vacuum Pump

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

Transcription:

Table of Contents 1 Contents Page 1 Table of contents 1 2 Introduction 2 3 Before Starting Guide to these Operating Instructions 3 Intended Use 3 Set -Up and Function 4 Sealing process 5 Safety instructions 6 Installation 6 Programming 7 Start Up 7 Configuration 8 4 Basic Functions Operation 9 5 Troubleshooting and Maintenance Troubleshooting Chart 10 HAWO Customer Service 10 Error massages 11 Warranty 12 Maintenance Chart 13 Parts Service 14 Parts Required for Maintenance and Wear 15 Replacement parts 16 Part numbers 17 Maintenance Information Replacing heating ribbon 18 Replacing knife for cutting device 19 Calibration 20 6 Technical Data Circuit and Wiring Diagram 230 V 21 Circuit and Wiring Diagram 150 V 21 Specifications 22 Declaration of Conformity 23 9.694.005 GB 1

Operating instructions 2 Introduction First we would like to thank you for purchasing the hm 460 / AS 8-V sealing machine. These instructions include information on the machine, its function and operation.! Please read these operating instructions thoroughly before using the machine so that you will be familiar with the capabilities of the machine and can utilize its features to the optimum. Always keep these instructions in the vicinity of the machine. Important note: This device is a packaging machine for the processing of thermoplastic films and composite films according to the thermal bonding or sealing process. In this respect, please pay attention to the Intended use chapter in the operating instructions. According to the intended use, the CE symbol was affixed on the basis of the EU Directives named below: 89/336/EEC, 98/37/EC and 73/23EEC amended by 93/68EEC. The 93/42EEC Directive is not applicable to bonding and sealing devices. The limit values stipulated in IEC 60601 1 cannot be applied in case of the electrical repetition tests. The manufacturer will not assume any liability for damage caused by tests according to standards which are not listed in the declaration of conformity. Note Since we continuously improve our products we reserve all rights to modify these operating instructions and the functions described therein. We make all possible efforts to keep these instructions free of errors and complete. If you note any errors or unclear points please advise us. GB 9.694.005 2

Before Starting 3 Guide to these Operating Instructions Before Starting This chapter contains information on the functions of the machine and instructions for handling and installation. BE SURE TO READ! Basic Functions Adjustment and operation of the machine are explained here. Troubleshooting and Maintenance Instructions for finding causes of malfunctions and eliminating them. This chapter includes information on the required maintenance, parts subject to wear and replacement parts. Technical Data Shows the interrelationship between various item numbers, the circuit and diagram plans and machine specifications. Intended Use The hm 460 and machine is intended for commercial and industrial applications and should be used only for the intended purpose. The hm 460 and hawomed machine is a sealing machine for sealing sterilization packages consisting of paper, paper laminate foil, Tyvek foil, polyethylene foils, soft PVC foils, polyamide foils or polypropylene foils. The machine capacity depends on the characteristics of the sealing material used. A maximum of 6 sealing processes per minute shall not be exceeded. Otherwise, the perfect function of the device is not guaranteed 9.694.005 GB 3

Before Starting 3 Set-up and Function type plate with supply voltage cutting slide upper sealing die lower sealing die roll tray mains switch sealing controller foot switch mains fuse line connection sealing temperature sealing pressure ( option) Sealing time Connection for line recorder cooling temperature serial connector PC RS 232 GB 4 9.694.005

Before Starting 3 Set-up and Function Sealing process Start End sealing die open ❶ ❺ closed Temperature ❷ ❸ ❹. cooling temperature sealing temperature teime heating sealing time cooling sealing heating time cooling ❶ After releasing the staring procedure: heating dies closed ❷ Start of heating process, ❸ Having reached the adjusted sealing temperature: start of sealing time ❹ After sealing time: start of cooling phase ❺ After falling below the adjusted cooling temperature: heating dies open 9.694.005 GB 5

Before Starting 3 General safety instructions The device must not be installed or operated by persons under 14 years of age. The device must not be operated unattendedly. Turn of the device or disconnect the power cord when it is not in use. Please don t touch the heating band with your fingers Please make sure, that there are no parts in between the sealing dies Installation Do not install or operate the machine in explosion hazard areas. Use only power sockets with protective ground. Set up the machine only in dry areas. Heavy dust, vapor, dripping or spraying water have a negative effect on the machine functions. Always ensure that the operating power corresponds to the specifications on the machine rating plate. Please choose a socket where the line power is stable. GB 6 9.694.005

Start-up Plug power cable into power socket on machine Insert plug into wall socket Switch on machine with power switch Before Starting 3 power switch line connection FUNCTION Machine switched on Display for approx. 3 seconds: Vxxx.xx = Program version DISPLAY Version xxx.xx Display of Sealing temp. sealing pressure Sealing time cooling temp. Machine is ready for operation Programming For example: Input of sealing temperature Ts =160º C F= 05 N ts =2.5 s Tc= 100º C Function Keys Display Configuration Activate select of sealing parameters system configuration sealing parameters Input sealing parameter Activate Input sealing temperature 180º C Position of cursor after activation Input º C Ts = 160º C ts =2.5 s Tc = 100º C Input º C Ts = 160º C 2 x Position of cursor after 2 x key Input º C Ts =1 6 0º C 2 x value of temp. after 2 x key Input º C Ts =1 8 0º C Configuration Return and activate entry Ts =180º C F= 05 N ts =2.5 s Tc= 100º C 9.694.005 GB 7

Before Starting 3 Konfiguration Function Keys display KONFIGURATION SEALING PARAMETER PIECE COUNTER LANGUAGE EVENT COUNTER PRESSURE SYSTEM CALIBRATION SEALING PARAMETER Temperature unit Celsius Fahrenheit º C º F Select Temperature unit system configuration Input º C Ts =160º C ts =2.5 s Tc= 100º C SEALING PARAMETER Sealing temperature 80º C - 300º C Input Sealing temperature Input º C Ts =160º C ts =2.5 s Tc= 100º C SEALING PARAMETER Sealing time 0-3 s Input Sealing time Input º C Ts =160º C ts =2.5 s Tc= 100º C SEALING PARAMETER Cooling temperature min 40% of sealing temp. max 100% of sealing temp. Input Cooling temperature Input º C Ts =160º C ts =2.5 s Tc= 100º C PIECE COUNTER Setting 7-digit Increment counter Display Absolute piece counter LANGUAGE D German GB English F French PRESSURE Activate of measurement pressing on pressure Input Piece counter Input Language Activating of measurement Piece count: 0000007 absolute: 1000000 Display piece counter TOTAL set language English GB pressing on pressure yes F = 5 N EVENT COUNTER Display Option counter event counter 0000008 GB 8 9.694.005

Basic Functions 4 Operation Sealing Operation Adjustment of sealing temperature Adjustment of sealing time Adjustment of cooling time Sealing foil in between the sealing dies Pushing of foot switch Check strength by tearing open seal. If unsealed points are present increase the sealing temperature. If the paper discolors or the foil peels off the temperature is too high. Determine suitable sealing temperature with sealing tests. A maximum of 6 sealing processes per minute shall not be exceeded. Otherwise, the perfect function of the device is not guaranteed 9.694.005 GB 9

Troubleshooting and Maintenance 5 Troubleshooting Chart Malfunction Possible cause Remedy Power connection Power cable not plugged in Check power connection, if necessary connect to different socket Machine can not be switched on Power cable defective Power fuse Replace power cable Replace power fuse! If fuse blows again always have machine checked Foot switch doesn t work Sealing seam is not tight Foot switch defective Sealing controller defective Sealing temperature too low Sealing time too short Cooling temperature too low Replace the foot switch Replace sealing controller Increase sealing temperature Increase sealing time. Increase cooling temperature. Replace folio material. Folio material too old Paper side is discoloured Sealing temperature too high Reduce sealing Temperature Folio became wrinkled Cooling temperature too low Increase cooling temperature No start possible Device in configuration mode Error massage See Error massages Your HAWO-Service Department is aivable Monday - Thursday 7.30-16.30 + Friday 7.30-15.30, under the telephone number xx49 (0)6261 9770-00 or (0)1726289126 GB 10 9.694.005

Troubleshooting and Maintenance 5 Error Messages Error: No pressure Error: sealing dies open Error: heat up time too high Message Possible cause Remedy DMS Module no function Controller HTR 300 no function Magnet defect Switch heating start no function Controller HTR 300 defect Heating transformer defective Heating band or heating connectors defect DMS Module re-calibrate or replacement Replace controller Replace magnet Check switch or replace Replace controller Check heating transformer or replace Replace heating band or heating connectors Error: cooling time too high Error: Resistor of heating band too high Controller HTR 300 no Function Controller HTR 300 no Function Heating transformer no function Heating band or heating connectors defect Controller HTR 300 no Function Replace controller Replace controller Check heating transformer or replace Replace heating band or heating connectors Replace controller 9.694.005 GB 11

Troubleshooting and maintenance 5 Warranty We assume a 12-month factory warranty for material and labor on all of our equipment corresponding to our general warranty terms for any proven defects. The equipment or parts thereof will be repaired or replaced as required at no cost. Please advise of warranty claims within 8 days. The warranty does not apply to transport damage to improperly packed equipment shipped to the supplier or manufacturer as a result of guarantee claims. When processing guarantee claims we reserve all rights to make technical modifications in the interest of technical progress and improvement of our equipment. Recognition of a guarantee claim does not increase the total guarantee period. Guarantee claims do not entitle the claimant to withhold payments in full or in part. We assume no liability for damage resulting from the following causes: Unsuitable or improper use, incorrect installation or start-up, erroneous operation, incorrect or careless operation, natural wear, use of unsuitable operating agents, chemical, electro-chemical or electrical effects. Moreover, any modifications or repair work accomplished improperly by the operator of the equipment or third parties without previous approval by HAWO are excluded from any type of guarantee. The same applies if genuine HAWO replacement parts are not used. Parts replaced shall become the properly of HAWO. GB 12 9.694.005

Troubleshooting and Maintenance 5 Maintenance chart As all technical equipment your equipment is also subject to technical wear. In order to ensure that your machine is always ready for use it should be serviced at least once annually by a trained technician. Lubrify Check Replace Maintenance chart teflon strip heating band silicon rubber silicon glass cutting knife controller axle bearing At least every 3 month Depending on use at least once annually axle bearing 9.694.005 GB 13

Troubleshooting and Maintenance 5 Parts Service Simply order parts by fax: Please copy the following pages according to the parts required. Page 15: Parts required for maintenance and wear Page 16: Replacement parts Enter machine number. Enter machine model Enter name, address, fax number and order number. Mark items required Enter quantity required. Sign order. Fax order. No.: 123456 Type: hm 460 GB 14 9.694.005

To: HAWO Gerätebau GmbH From: Fax Nr.. 0049 (0) 6261 64752 Order No Date: Machine model Maschine number Designation Part No qty Knife for cutting device 2.593.001 hm 460 Teflon strip upon heating band 6.105.113 Teflon strip under heating band 6.105.150 Heating band 6.535.082 Silicon rubber 6.105.280 Silicon glass reinforced laminate 6.105.261 Teflon strip upon heating band 6.105.114 Teflon strip under heating band 6.105.154 Heating band 6.535.083 Silicon Rubber 6.105.265 Silicon glass reinforced laminate 6.105.216 Signature 9.694.005 15 GB

To: HAWO Gerätebau GmbH From: Fax Nr. 0049 (0) 6261 64752 Order No Date: Machine Model Machine number Designation Part No qty Guidance sled compl. for cutting device 1.629.001 Power switch 6.545.004 Foot switch complete 1.592.008 limit switch 6.561.002 joining piece (stamp) 1.629.006 Pressure spring (beam l+r) 6.181.003 Pressure spring (lower beam) 6.181.005 pressure spring (magnet) 6.181.001 welding transformer 6.531.030 lifting magnet power cable ( 230V ) 6.593.013 power cable ( 115V ) 6.593.014 Sealing controller DMS Modul 1.410.018 Signature GB 16 9.694.005

Trobleshooting and Maintenance 5 Part numbers upper sealing die hm 460 6.105.280 6.105.265 hm 460 6.105.150 6.105.144 hm 460 6.535.082 6.535.083 hm 460 6.105.113 6.105.114 hm 460 6.105.113 6.105.114 hm 460 6.535.082 6.535.083 hm 460 6.105.150 6.105.154 lower sealing die hm 460 6.105.261 6.105.216 1.629.006 6.181.003 9.694.005 GB 17

Troubleshooting and Maintenance 5 Maintenance Information Replacing heating band! Please use only genuine HAWO replacement parts Switch of machine and DISCONNECT POWER PLUG Disconnect heater band connections ❶ Remove mounting screws ❷ and remove sealing die. Remove mounting screws ❸ and detach clamping device Detach teflon strip. ❷ ❸ ❶ ❶ Remove mounting screws ❹ of heating band clamping device Remove old heating band. Cramp the new heating band on one side of the sealing die Extend the heating band across the sealing die. Move the heating band trough the clamping device and stretch it. Fix the screw ❹ of the heating band clamping device Fit a new teflon strip without wrinkling Fasten the clamping device Fit the sealing die Connect the heating band connections ❶ ❹ GB 18 9.694.005

Troubleshooting and Maintenance 5 Maintenance Information Replacement of cutting knife! Please use only genuine HAWO replacement parts Switch of machine and DISCONNECT POWER PLU Remove upper sealing die ❶ ❶ ❶ Replace the cutting knife ❷ with a socket- or fork spanner wrench size 8 or turn it round about 180 degrees ❷ 9.694.005 GB 19

Troubleshooting and Maintenance 5 Calibrations Zero setting After replacement of the heating band or the sealing controller the zero setting has to be done. Function Keys Display SEALING PARAMETER PIECE COUNTER LANGUAGE EVENT COUNTER PRESSURE SYSTEM CALIBRATION SYSTEM CALIBRATION Please measure the room temperature! Input Room temperature system configuration system calibration room temp. = 20 º C Pressing on pressure Function Keys Display SEALING PARAMETER PIECE COUNTER LANGUAGE EVENT COUNTER PRESSURE SYSTEM CALIBRATION PRESSURE Activate measurement of pressure Activation of measurement system configuration pressing on pressure yes F = 5 N CALIBRATION PRESSURE 1. Prior to adjustment unscrew screw S totally 2. Adjusting zero point to 5 N using potentiometer P1 3. Set pressing -on pressure to 20 N using screw S 4. Activate foot switch and key succcessively The sealing dies get closed without starting heating an sealing time Caution! Before calibration the device have been switched on for at least 5 minutes + pressing on pressure yes F = 5 N pressing on pressure yes F = N pressing on pressure hm 460 pressing on pressure yes F = 300 N pressing on pressure pressing on pressure yes F = 250 N GB 20 9.694.005

Technical Data 6 Circuit and Wiring Diagram 230 V upper lower heating band Magnet Foot switch Start heating Sealing controller Circuit and Wiring Diagram 115 V upper lower heating band Magnet Foot switch Start heating Sealing controller 9.694.005 GB 21

Technical Data 6 Specifications Power connection [ V ] 230 / 115 Main fuse 230 V (115V) [ A ] 10 T ( 20 T ) Power consumption max [ VA] 280 Heat disipation [ kj/s] 0,1 Ambient temperature [ C ] 5-25 Dimensions lenght [ mm ] 530 hm 460 width hight 700 300 220 Weight ca [ kg ] 25 Sealing temperature [ C ] 80-300 Sealing time [ s ] Colling temperature [ C ] Min Max 40% of Sealing temperature 300 Film width [ mm ] 400 hm 460 570 Film thickness [ mm ] 2 x 0,4 Seal seam length [ mm ] 450 hm 460 630 Cutting length [ mm ] 360 hm 460 540 Sealing seam width [ mm ] 8 GB 22 9.694.005