ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

Similar documents
Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

HARDWARE KIT INSTALLATION GLOVES

Safety, Installation and Service Manual Models 1952, 1953 & 1972

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

INSTALLATION INSTRUCTIONS

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

UV-AIRE AIR PURIFYING SYSTEM

Installer s Manual. PCO/UV N-Duct Model

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

WARNING Risk of property damage, injury, or death.

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

Installation & Maintenance of the Fresh-Aire UV Tubular Rack System for Commercial Air Handler Systems

PHOTO-CATALYTIC AIR PURIFIER SYSTEMS

Installation Instructions

UV-AIRE AIR PURIFYING SYSTEM

BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems

LUNA Air for life. Featuring: NASA Developed Technology. Owner s Manual. Photocatalytic Oxidation Induct Air Purification System.

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

INSTALLATION TEMPLATE

UNPACKING THE UNIT. Alcohol cleaning pad

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

21", 33", 45", & 61" Installation & Operation Manual

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

WARRANTY. Air flow. (Please note standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.

BIO-FIGHTER 4Xtreme 21", 33", 45" Ultraviolet Light Systems

Ultraviolet Systems RXIU-A02A, RXIU-A03A TREATMENT SYSTEMS

MCI. SynAIRgPURE. Owner s Manual

Installation Instructions

UV100A Ultraviolet Systems UV100A1000 AND UV100A1018 AIR TREATMENT SYSTEMS UV100A1059 AND UV100A2008 SURFACE TREATMENT SYSTEMS

Installation Instructions

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

COILCARE PM. Installation Instructions and Operating Manual. CoilCare Series BioZone Scientific International, Inc.

VH03 SAVE THESE INSTRUCTIONS

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

Air Knight REME by RGF

Portable Sanitizing Wand. Model: VH03. The CleanWave Portable Sanitizing Wand kills up to 99.9% of germs and odorcausing. surfaces.

Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System For PTAC & ETAC Units

For Mini Split Units. Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System

INSTALLATION, MAINTENANCE & OPERATION GUIDE. MODEL Sanuvair S300 WHOLE HOUSE HEPA/UV AIR PURIFIER. ITEM # Sanuvair S V EN

IMPORTANT: SAFETY INSTRUCTIONS

2008 PCP COMPOUND APPLICATIONS GUIDE


APCO Rack System. A unique solution for the elimination of viruses, bacteria and VOC s. and saving energy FRESH-AIRE UV

IMPORTANT SAFETY INFORMATION

FOODSAFE IL INSTALLATION MANUAL

IMPORTANT SAFETY INFORMATION

ULTRAVIOLET WATER DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL

110 Volt/12 Volt Portable Inflator

MINISTICK TM UV Germicidal Ultraviolet Light

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

Conduit ~15" Inlet. UV Sterilizer - Connection to Forcemain

CAUTION: Read manual carefully for proper procedures and operation.

230VAC Power Inverter 400W Owner s Manual

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

EXT DUCTLESS FUME HOOD

OWNER S MANUAL MODELS EADM900UV-VO-A & EADM900UV-VO-VS WHOLE-HOUSE DUCT MOUNT HEPA AIR CLEANER WITH ULTRAVIOLET LAMP & PHOTO CATALYTIC FILTER

Air Bear Supreme and Air Bear Cub. Media Air Cleaners READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

Spotlight 1,000,000 Power Series Cordless Rechargeable

Model AERO-24. Model ADHO24-4. Model AD24-2

Motorized Stainless 2-Way Valves

Further information: Berriman Associates Model 850P.2 Owners Manual

MODEL 950C-NP-UV Installation and Owners Manual

GPS-iConnect Installation Operation & Maintenance Manual

AeraMax Pro AM IV. Please read these instructions before use. Do not discard: keep for future reference.

Installation, Operations and Maintenance Guide

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

SPH-400 i Series General Manual

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

POWER PINNER HAND WELDER 7200 OPERATOR S MANUAL

IMPORTANT SAFEGUARDS

POWER PINNER CD HAND WELDER 7300 OPERATOR S MANUAL

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

HQUA. UV Water Sterilizer Instruction Manual. Contents

EXPERIENCE THE NEW IAQ REFRESH YOUR AIR

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

VCM LAMINAR FLOW HOOD VERTICAL

IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System. Perfect 16. Installation Manual

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

12 Volt Heavy-Duty Air Inflator

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Inductive. SeekTech Clamp WARNING! Operator s Manual

O W N E R ' S M A N U A L

Air Curtain. Installation, Operating and Maintenance Instructions

MR6F LED Windshield Lights

DUAL PURPOSE DIAGNOSTIC LEAK DETECTOR

Installation Instructions

JET METER INSTRUCTIONS

EXT HEPA/CARBON FUME HOOD

ATTENTION: PLEASE READ AND UNDERSTAND ALL INSTRUCTIONS AND WARNINGS BEFORE ASSEMBLING, INSTALLING OR USING THIS PRODUCT.

NANOpure Infinity UV Module Upgrade

TPC. User Manual. LED 70N Cordless LED Curing Light

PLEASE READ THESE INSTRUCTIONS BEFORE USE

Transcription:

Shown with ILS OPTION (Internal Bracket/Light Shield) Kit ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE Remote version shown Models: UMX-1224T/ UMX-1924T / UMX-12242T / UMX-19242T 24v Power Input with Remote Mount Lamps UMX-1200T/ UMX-1900T / UMX-1202T/ UMX-1902T 120v 240v Power Input with Remote Mount Lamps UMX-1000T3/ UMX-2000T3 / UMX-1036T3/ UMX-2036T3 120v 240v Power Input with Fixed Mount Lamps UME-1224T/ UME-1924T / UME-12242T / UME-19242T 24v Power Input with Remote Mount Lamps UME-1200T/ UME-1900T / UME-1202T / UME-1902T 120v - 240v Power Input with Remote Mount Lamps UME-1000T3/ UME-2000T3 / UME-1036T3/ UME-2036T3 120v 240v Power Input with Fixed Mount Lamps Page 2 Shipping and Packing list, Safety Precautions Table of Contents: Page 3-4 General Application Guidelines and Recommended Installation Page 5 Installation Steps for External Remote Lamp Mounting with External Mounting of Power Supply, Installation options for Optional ILS, Installation Steps for Optional Re-Fresh PCO Module Page 6 Maintenance, Troubleshooting, Lamp Replacement and Reset Procedure Page 7 UV Lamp Monitor, Power Consumption and Replacement Part Number, Warranty Page 8 ILS Installation options LEAVE FOR HOMEOWNER DC-IH-0232

Shipping and Packaging List: UMX/UME Electrical Housing Eight ¾ inch 5/16 self tapping screws UVC Warning Label Warranty Card Remote mount Viewport Label Remote mount Viewport Two Wire Nuts (for 24V systems) 40 VA multitap transformer (for 24V systems) Four T3 Lamp mounting screws Two T3 Lamp mounting plates UMX/UME- 1224T, 1200T, 1000T3 One 12 T3 UVC Lamp One T3 Lamp mounting gasket UMX/UME- 12242T, 1202T, 2000T3 Two 12 T3 UVC Lamps Two T3 Lamp mounting gaskets UMX/UME- 1924T, 1900T, 1036T3 One 17 T3 UVC Lamp One T3 Lamp mounting gasket UMX/UME- 19242T, 1902T, 2036T3 Two 17 T3 UVC Lamps Two T3 Lamp mounting gaskets OPTIONS -PCO (Photocatalytic Oxidation Module) Ultra-Ion Re-fresh PCO module w/ gasket Four ¾ inch 5/16 self tapping sheet metal screws Safety Precautions: It is recommended that this unit be installed and maintained by a trained technician: WARNING: UV Hazard. Always protect eyes from ultraviolet light. NEVER look at UV lamps in operation. Turn off power before re-lamping or servicing. WARNING: Severe eye damage or temporary blinding may occur. WARNING: DO NOT operate outside of Air Handler. Mount lamp base to duct first. WARNING: No openings in duct are allowed which would give direct line-of-sight to the UV light. In the event of accidental breakage or replacement of the ultraviolet lamp, please ensure that the lamp is disposed of in accordance with local and state environmental laws regarding fluorescent lamps containing mercury. Notice: All wiring inside of the duct or air handling system in direct line of site of the UV lamp must be shielded with aluminum foil tape or equivalent non-combustible material. When installing this unit, select a mounting location that prevents ultraviolet light exposure to plastic flexible duct liner or other plastic components with unknown resistance to ultraviolet light. Ultraviolet light may cause color shift or structural degradation of plastic HVAC components -ILS (Internal Bracket/Light Shield) 1 Per Lamp Internal Mounting / Light Blocking shield One Lamp Clips One Heavy Duty mounting magnet Associated Hardware 2

General application guidelines for Ultramax Ultraviolet air purification systems Ultravation manufactures several configurations of Ultraviolet disinfection products to meet any installation criteria. Ultravation two lamp ultraviolet systems are designed to adequately treat up to a 5 ton system or 3,500 sq ft. Whenever possible use a two lamp configuration with the longest lamp length possible for the installation. Up Flow **Up Flow Ultravation suggests mounting on the exit side of the HVAC system before the ductwork branches off. This will ensure that the airborne contaminants reaching the ultraviolet purification system and the OPTIONAL Re-Fresh Odor reduction module have been reduced to an acceptable Micron size by the HVAC systems filter. Ultravation Ultramax products have been designed for peak performance in the cooler temperatures commonly found in the supply plenum of a typical HVAC system. Installing an Ultraviolet system in the return may degrade the media filter and/ or collect dirt particles on the UV lamp glass gradually decreasing performance. If this is the obvious source of microbial growth then placing the Ultraviolet system in the return is the best solution. **Caution must be taken to ensure Ultraviolet light is not coming in contact with the media filter or being exposed outside the enclosed system. Ultravation s exclusive OPTIONAL Re-Fresh odor reduction module performs continuous photo catalytic processing, constantly reducing or eliminating unwanted odor and bacteria resulting in clean fresh breathable air. Ultravation Ultraviolet systems produce no ozone. There is no harmful by-products or off gassing taking place in the sterilization process or the photo catalytic process. Up Flow **Up Flow Horizontal The surrounding illustrations show the flexibility offered with the Ultravation Ultramax product line actual installation may vary depending upon installation criteria, if you need help or have questions call our toll free help line: 1-866-GO-UV-AIR 468-8247 ext 16 9:00 am 5:00 pm Est. Horizontal 3

Recommended Installation OPTIONAL: Exclusive Re-Fresh PCO odor reduction Module - reduces odor, VOC s and bacteria. Simply add more for greater odor reduction. Produces no ozone or other hazardous gases! Available in single and dual lamp configurations. Ships with multitap transformer to adapt to all household voltages Full 10 year warranty Patented T3 lamp technology provides 40% more UV than the competition Mounting Plate with gasket material provides a safe air tight fit Patented lamp safety connection, prevents accidental exposure to harmful UV rays. 6 Ft. remote lamp leads allow for the flexibility required for most installs. 4

Installation steps for remote lamp mounting, remote lamp replacement, and external mounting of power supply: 1. Remover the cover from the electronic housing. 2. Determine a suitable location to install unit housing. Mounting location should be of sufficient strength as to support the unit; otherwise reinforcement of the ductwork may be necessary. Lift into place against ductwork. Fasten unit in place with two self- tapping screws (supplied). 3. Install supplied #10 3/8 inch pan head screw (for anchoring electronic housing cover) 4. Select location for UV lamp module; drill a 1 hole for each lamp. Mount mounting plate over drilled hole with screws provided. Insert UV lamp module into hole. Attach to mounting plate with 2 self-drilling screws (provided). 5. Plug the rubber lamp connector fully onto the installed UV lamp assembly. Be sure the 4 pinholes are orientated properly to the 4 mating pins of the lamp. 6. Connect power to unit. (It is recommended that the system be powered constantly, not cycled with HVAC system power) Note: The T3 UV lamp assembly can be removed independently, simply by removing the 2 screws in the lamp base. Note: the pins are in a rectangular patent and can only be mated in 2 positions. (See below) Installation options for Optional ILS (Internal Bracket/Light Shield): The Internal Bracket/Light Shield is a versatile kit that can be used for mounting the UVC lamp(s) internally via screw mount or utilizing the heavy duty magnet for even easier mounting. It can also be used as a light shield to block the intense UVC energy from breaking down non metallic materials such and filters or allowing the UVC energy to escape through return grills. For the full range of configurations please review page 8. Installation steps for Optional Exclusive Re- Fresh PCO odor reduction Module: 1. Find a location adjacent to the UV lamps to mount the PCO module. To activate the PCO module it requires UV light shinning on its surface. PCO module can be mounted within inches of the UV light, or if necessary the module can be within 2 ft. of direct UV light and still be activated. 2. To mount the PCO module you will need to drill one 2 1/2 diameter hole. The base plate of the module will need to be screwed to the duct or air handler with the 4 screws supplied. 3. The PCO module measures 14 ¾ inches long by 2 ½ diameter. The surface area of the module relates directly to the amount of VOC s it can eliminate. If necessary the Module can be trimmed to a shorter length to accommodate installation in the air handler. It is beneficial to install additional PCO modules in the area of the UV lights, thereby increasing the airborne bacteria disinfection rate and the removal of VOC s. Also the PCO modules may be installed completely internally. Installation steps for UVViewport: 1. Find a location on the airhandler or ductwork that will visible and be in direct line of site of UVC light. 2. Affix UVViewport label to air handler or ductwork. 3. Drill a 3/8 hole through label and air handler or ductwork in marked location on label. 4. Press in UVViewport until it snaps into place. 5

Maintenance: Typical maintenance consists of replacement of the ultraviolet lamps. UV lamps undergo a photochemical process during operation. This slowly reduces the amount of UV light generated to disinfect against airborne pathogens. For optimum air stream disinfection against airborne pathogens it is recommended the UV lamps be changed on an annual basis. When installing new lamps, ensure that the lamp glass is free from any fingerprints or debris, as this may alter the path of the UV energy. Use rubbing alcohol and a dry cloth to remove any surface contaminants. The Optional PCO/VOC Module when used with a MERV 11 (minimum) rated filtration, no maintenance will be required for 10 years. Troubleshooting: Important information: It is a normal characteristic of all UV lamps to blacken around the filaments of the lamp. This does not signify the lamp is defective or not emitting Ultraviolet light. The only time a UV lamp is defective is if it will not light. UV Lamps that illuminate will not qualify for Warranty. Verify the unit has 24vac or 120V - 240V When resetting the unit, depress reset button. (if the unit does not reset, wait 5 minutes to depress again) Power switch is in the ON position Lamps are securely plugged into their sockets The electronic circuit of a 2-lamp system only operates when both lamps are operating. Verify what signal if any the UV Lamp Monitor LED is emitting. (See adjacent). Verify if in fact the UV lamps are on or off. Do not look at the UV light without proper eye protection. Lamp Replacement and Reset Procedure: *See Lamp Installation for Replacement Procedure. NOTE: When replacing lamps after 1 year or 2 years of operation disconnect power to the unit first. After the lamps are in place, complete steps 1-4 to set the service indicator to 0. For optimum 24/7 air stream disinfection it is recommend the UV-C lamp is replaced on an annual basis. Service Indicator Light (FOR UMX SERIES ONLY): To set the service indicator Light: It is recommended that a certified technician perform this operation. (For the fixed lamp UMX system the cover must be removed and power left on the reset switch in inside the equipment) 1. To set or reset the annual service indicator the unit must have power to it. 2. Press down and hold the square yellow RESET button (hold down for 10 sec.) on circuit board (located below LED view port on the end of the electrical housing), the LED should turn GREEN while the button is depressed. 3. Release the square yellow RESET button. 4. LED should be Green. Please contact your local dealer or Ultravation directly for replacement lamps There are NO user serviceable parts inside. Refer servicing to qualified service personnel. Note: A flashing red every 1 second and a beep every 1 second does not necessarily mean the lamps are defective or no longer emitting UV, it is sensing the lamp(s) in the unit are not on. This could be caused by other factors. In this case a service technician should be contacted. Please contact your local dealer or HVAC contractor for replacement lamps. NOTE: If just a single UVC lamp of a 2 lamp UVC system is light, than the lamp that is not light is out of orientation. 6

UV Lamp Monitor: LED Color Green Audible Visual Alarm No audible Unit Status OK Solid Red Flashing Red (Every 5 seconds) Pulsing Red (Every 1 second) No Audible Beep every 3 Minutes Beep every 1 second Reset lamp service indicator or replace lamp within 30 days Occurs at approx. 11 months of operation Lamp has exceeded 1 year of operation, reset or replace lamps UV lamp(s) are not lit (verify if possible) Replacement Parts: Model Description Replacement Part Number UME/UMX 1224T, 12242T, 1200T, 12 T3 Lamp ASIH1001 1202T, 1000T3, 2000T3 UME/UMX 1924T, 19242T, 1900T, 17 T3 Lamp ASIH1003 1902T, 1036T3, 2036T3 All UVC Equipment Ultra-ion Re-fresh PCO Module 94-004 Warranty: Ultravation warrants this product against any defects in material or workmanship for a period of 10 years (except UME series which is 5 years) after date of consumer purchase, with the exception of the Ultraviolet Lamp, which is warranted for a period of one year after date of consumer purchase. This warranty does not include damage to the unit from accident, misuse or improper installation. If this product should become defective during the warranty period, Ultravation will elect to repair or replace the product free of charge. Ultravation will return repaired or replaced warranted products pre-paid, provided that the product was delivered pre-paid. Ultravation shall have no responsibilities for charges incurred by the customer for installation or removal of warranted items. Liability is limited only to the replacement or repair of this product This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. All returns must be accompanied by a return authorization number, which may be obtained by contacting Ultravation, Inc. Ultravation, Inc. ~ P.O. Box 165 ~ 212 Ideal Way ~ Poultney, Vermont 05764 Phone: 802-287-9735 ~ Fax: 802-287-9203 ~ 7