HARTZELL. Cool Blast, Utility, and HartKool. Fans. Hartzell Fan, Inc., Piqua, Ohio

Similar documents
HARTZELL. Power Roof Ventilators. Hartzell Fan, Inc., Piqua, Ohio

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

FADE Series Wall Axial Fans

8-12 INSTALLATION AND WIRING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS

ered Installation, Operation, and Maintenance Manual Direct Drive sizes 6-15 Nonoverloading B.I. Wheel

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL

Models GED/GSD, DFE/DFS & DDE/DDS Installation, Operation, and Maintenance Manual

Good Enough Never Is. Plug Fan SERIES 12

BULLETIN: VB PVC BLOWER-SCRUBBER VIRON INTERNATIONAL

SDBDe, STXDe, ered* Installation, Operation, and Maintenance Manual INSTALLATION AND WIRING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS

HP190SL Series Slimline Radon Fans

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

Model CWD Installation, Operation, and Maintenance Manual

Models eged/egsd. Installation, Operation, and Maintenance Manual. Direct Drive Sidewall Propeller Fans (Exhaust and Supply)

Rapid Ship. Fast Shipment of Stock, Modified Stock and Build to Order Fans. Quality Value Commitment. Fan Solutions FAST!

Bulletin REXJR05 CENTREX REX JR. Model: REXJR Direct Drive Centrifugal Inline Fans

SDBDe, STXDe, STXDeRHUL

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

2SHE Series Direct-Drive Shutter Fans

FIXED PITCH PROPELLER FANS

Mancoolers Models MCY, MCB, MCP

SOLAR DASH CHARGING SYSTEM USER GUIDE

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

OPERATING MANUAL. aeration fans. models: sa sa sa SAFETY PRACTICES

WARNING. Introduction ! ATTENTION

OPERATING MANUAL. centrifugal fan SAFETY PRACTICES

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

Type VA Vanax Fans. Models VA, VAD, & VAB

HR-20P Pneumatically Controlled Pressure Regulator

COOL DRAFT INSTRUCTIONS OWNER S MANUAL CONTENTS. Cool Draft MiniMister 14 Misting Fan CDMP1420BLU

Pressurized oil drain for collection of used lubricants and anti-freeze.

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

FarmTek Stock Numbers

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

20250 Module Installation Guide

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

GLYCOL SYSTEM MONITOR (GSM)

EMISSION CONTROL WARRANTY STATEMENT

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

2017 Price List 2018 Price List

Direct Gas-Fired Heating

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

30100 Module Installation Guide L

CU6703 Module Installation Guide

Users Guide for Ac-sync

EXHAUST FAN FLOW METER

HA/HAB Fiberglass Wall Mount Ventilators

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

MANCOOLERS. Macheta Airfoil Propeller Model UM / PUM / M39 / STL. Utility Mancooler Model UM. Pedestal Mount Mancooler Model PUM

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

VANEAXIAL & TUBEAXIAL FANS

5DDU-EC Series Direct Drive Upblast Roof Ventilator

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

15100 Module Installation Guide Mercedes EPA07 w/dpf

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

Twin City Fan & Blower

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

Turning Air Into Solutions. PLUG FANS TYPE BCPL

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

Motor Mounting Kits. Instructions J EN. 16C487 Motor Coupler Kit includes 2.25 in. (57.2 mm) key For NEMA 182/184 TC Frame ATEX Electric Motors

Types RE & RES- Recirculating Roof Ventilators

Direct Drive Centrifugal Exhausters Low Profile Roof/Sidewall and Roof Downblast

Belt Drive Propeller Fans. Catalog GS Series Catalog HC Series JANUARY I j(1

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

Female Plug. connecting to Fuel Quantity

OPERATOR S MANUAL. MODEL ORDER # MODEL HD 2.0/10 Ed HE D HD 1.8/14 Ed HE D

Centrifugal Filtered Supply Fans

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG BUNN-O-MATIC CORPORATION

II DISTRIBUTION & SUBSTATION TYPE C

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

GM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com

CEAT SPECIALTY TIRES INC. LIMITED WARRANTY POLICY For AGRICULTURE BIAS TIRES

INVERTER HARNESS INSTALLATION FOR FREIGHTLINER CASCADIA

Air Curtain. Installation, Operating and Maintenance Instructions

Broadband PowerShield. CP27U Models. User Manual

JDCR2000 Module Installation Guide

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

WEB CONTROL PRODUCTS

PLINKO Instruction Manual Model #7760

EF SERIES MOTORS OPERATION & PARTS MANUAL

Submersible Waterfall Pump 1200 Gallons Per Hour

SUNTURA SOLAR TRACKER

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

JD2800 Module Installation Guide

PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

BCFS Belt Driven Centrifugal Filtered Supply Fans

SELECT/DIRECT DEMO BOX USER GUIDE. INST164 Doc 1.00

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

Premium Series Grease Dispensing Handle One and Two Piece Body Styles

4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

Transcription:

Cool Blast, Utility, and HartKool Series 20 Series 21 Series 22 Series 23 HKA Fans BUILT WITH HONOR HARTZELL FAN, INC PIQUA, OHIO USA HARTZELL Hartzell Fan, Inc., Piqua, Ohio 45356 November 2008

Index Model Code Explanation......... Page 2 Cool Blast Fans Series 20 & 21.. Page 3 Utility Fans Series 22 & 23...... Page 4 Fan Selection The Hartzell Cool Blast, Utility, and HartKool Fan performances on the following pages are based on standard air conditions (sea level, 70 F, and 29.92 inches barometric pressure). When placing your order, be sure to specify the Hartzell Model Code. The following example demonstrates our coding system. The illustrated Series Number specifies a Hartzell Series 20 Cool Blast Fan. Spread and Throw of a Fan....... Page 5 HartKool Fans Series HKA...... Page 6 HartKool Fan Accessories....... Page 7 Hartzell Model Code Explanation A 20 28 2 ND S T FC D 3 Type A Production Item S Stock Item Q Special Quote Product Series Arrangement (centrifugals only) Size (nominal wheel diameter, inches) Class/ Blades (class for centrifugals; blades for axial) Wheel Code Wheel Width/ Blade Angle (width (%) centrifugals/ angle axials) Material of Construction Motor Enclosure Motor Horsepower Motor RPM/ Phase Motor Horsepower Horsepower 1/4 1/3 1/2 Be sure to include fan model, performance requirements, operating temperature, and motor data (enclosure, voltage, mounting position, etc.). Contact your local Hartzell Sales Representative for assistance. Motor RPM/ Phase 3 Phase 1 Phase 2 = 3450 B = 3450 3 = 1750 C = 1750 4 = 1140 D = 1140 5 = 870 E = 870 6 = 690 F = 690 7 = 575 G = 575 3/4 1 1 1 /2 2 3 5 7 1 /2 10 15 20 25 30 40 50 60 75 100 125 150 200 Code Letter D E F G H I J K L M N O P Q R S T U V W X Y Z How To Use Model Code Index: Example Assume a required performance of 6730 CFM at Free Air, at standard conditions. Reading the rating table on page 3, we find a Series 20, 28" size, with 6724 CFM at Free Air. This unit has a 2 blade propeller. Required motor horsepower is 1/4. The model code can be constructed as follows: Type will be a production item (code A), product series for the Cool Blast Fan is 20, size of the wheel is 28", number of blades is 2, blade is ND. Material of construction is steel (code ST), motor is totally enclosed, air over (code AO), motor horsepower is 1/4 (code D), and motor RPM/phase is 1750 RPM/3 Phase (code 3). Note: All other informational fields must be filled with hyphens/dashes ( ) if they are not applicable to the fan being considered. This bulletin lists Hartzell s complete line of Cool Blast, Utility, and HartKool Fans. More than 70 Hartzell offices can provide specific performance and installation data to meet your requirements. Call your Hartzell representative for assistance. Visit our website () or call toll-free for the name of your Hartzell representative... 1-800-336-3267 2

Cool Blast Fans Series 20 & 21 Stationary Series 20 Rating Table Series 20 & 21 SERIES 20 STATIONARY Sizes 20" 48" Tip-proof base, rugged steel construction Tilt head type available through 40" SERIES 21 PORTABLE Sizes 20" 40" Widespread 3-point base Hard rubber casters adjusting screw Tilt head type 45 up, 30 down Portable Series 21 Features Cool Blast Fans Designed to withstand heavy industrial use. Extra heavy bases and support columns. Portable models have casters on two widespread legs with adjusting screw 40" and smaller only. Tilting head design available thru 40" size. Notes: Cool Blast Fans are equipped with TEFC continuous duty, ball bearing motors. Motors extended beyond the OSHA approved guard for easy maintenance. Fans are available with switch mounting plates; switches and wiring from switch to fan motor. All guards shown on Cool Blast Fans meet the Occupational Safety and Health Requirement Act dated May 29, 1971. Motor Approx Size Model Code HP RPM CFM Ship Wt. 20" A --202NA---STFCD3 1 4 1725 4168 224 A --203-L---STFCF3 1 2 1725 4905 228 A --242NA---STFCD3 1 4 1725 5529 244 24" A --242NB---STFCF3 1 2 1725 7170 250 A --242NC---STFCG3 3 4 1725 7936 260 A --242NC---STFCD4 1 4 1140 5245 255 A --282ND---STFCD3 1 4 1725 6724 267 A --282NA---STFCF3 1 2 1725 7928 301 28" A --282NB---STFCG3 3 4 1725 10032 311 A --282NC---STFCH3 1 1750 10571 331 A --282NC---STFCD4 1 4 1140 6860 301 A --282-L---STFCG4 3 4 1140 8739 334 A --322NB---STFCH3 1 1750 12627 345 32" A --322NA---STFCF4 1 2 1140 10692 340 A --323-L---STFCI4 1 1 2 1160 13293 375 A --323-L---STFCF5 1 2 850 9741 360 A --362ND---STFCH3 1 1750 15418 374 36" A --362NA---STFCH4 1 1160 16178 396 A --363NA---STFCJ4 2 1160 18770 420 A --363-L---STFCH5 1 870 14170 415 A --402ND---STFCH4 1 1160 17457 425 40" A --402NA---STFCJ4 2 1160 22750 456 A --402NA---STFCH5 1 870 17077 455 A --403-L---STFCJ5 2 870 20400 470 A --442NB---STFCJ4 2 1160 25400 555 44" A --442NA---STFCK4 3 1160 30103 584 A --446-P---STFCJ5 2 870 23223 580 A --443-L---STFCK5 3 870 26600 686 A --482NC---STFCJ4 2 1160 27871 615 48" A --482NA---STFCJ5 2 870 27400 640 A --486AA---STFCK5 3 870 32430 746 A --483-L---STFCL5 5 870 32700 783 Bold type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code explanation and example. Overall Dimensions Fan Size Height Width* Depth** Base Diameter 20 59 1 2 23 18 24 24 61 1 2 27 18 24 28 63 1 2 31 18 24 32 65 1 2 35 21 3 4 30 36 67 1 2 39 22 3 4 30 40 69 1 2 43 22 3 4 30 44 71 1 2 47 26 36 48 73 1 2 51 26 36 Centerline of fan to floor is 48" on all models. * Portable base is 32" wide. ** Varies slightly with motor size. 3

Utility Fans Series 22F, 22H, 22T & 23 Stationary Series 22T SERIES 22T, 22H, 22F STATIONARY Sizes 20" 36" Heavy duty round base Flat base-mount on wall, post or ceiling Tilt head type 45 up, 30 down Portable Series 23 Flat Base Series 22F SERIES 23 PORTABLE Sizes 20" 36" Portable wheel base with handle Rubber tire disk wheels Tilt head type 45 up, 30 down Features Utility Fans Designed to withstand heavy industrial use. Compact in design very versatile. Requires limited space. Portable wheel model can be moved from area to area very easily. Wheel model standard with 14" rubber tire disk wheels; available with 14" steel wheels. Flat base model can be mounted on wall, post or ceiling out of the way, eliminating extension cords. Notes: Utility Fans are equipped with TEFC continuous duty, ball bearing motors. Motors extended beyond the OSHA approved guard for easy maintenance. Fans are available with switch mounting plates; switches and wiring from switch to fan motor. All guards shown on Utility Fans meet the Occupational Safety and Health Requirement Act dated May 29, 1971. Rating Table Series 22T, 22H, 22F & 23 Motor Approx Size Model Code HP RPM CFM Ship Wt. 20" A --202NA---STFCD3 1 4 1725 4168 224 A --203-L---STFCF3 1 2 1725 4905 228 A --242NA---STFCD3 1 4 1725 5529 244 24" A --242NB---STFCF3 1 2 1725 7170 250 A --242NC---STFCG3 3 4 1725 7936 260 A --242NC---STFCD4 1 4 1140 5245 255 A --282ND---STFCD3 1 4 1725 6724 267 A --282NA---STFCF3 1 2 1725 7928 301 28" A --282NB---STFCG3 3 4 1725 10032 311 A --282NC---STFCH3 1 1750 10571 331 A --282NC---STFCD4 1 4 1140 6860 301 A --283-L---STFCG4 3 4 1140 8739 334 A --322NB---STFCH3 1 1750 12627 345 32" A --322NA---STFCF4 1 2 1140 10692 340 A --323-L---STFCI4 1 1 2 1160 13293 375 A --323-L---STFCF5 1 2 850 9741 360 A --362ND---STFCH3 1 1750 15418 374 36" A --362NA---STFCH4 1 1160 16178 396 A --363-L---STFCJ4 2 1160 18770 420 A --363-L---STFCH5 1 870 14170 415 Bold type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code explanation and example. 4

Formulae for Determining the Spread and Throw of a Fan We have been asked many times for information on the velocity from a fan and also the width of the stream at a specific distance. While these values are influenced greatly by the presence or absence of walls, floors and obstructions, the following formulae will give a good approximation for most cases. It should be noted that the spread and throw formulae are unique to Hartzell and specifically the Hartzell Utility and Cool Blast Models. The equations were developed based upon tests performed with Hartzell Utility and Cool Blast fans in the Hartzell research and development testing facility. The equations will not work for fans manufactured by others. SPREAD: d W = 0.36L + 12 W = Maximum width in feet of airstream perpendicular to axis of rotation of the fan. L = Distance from fan in feet. d = Fan diameter in inches. VELOCITY (Not less than 10 feet from fan): (1) k = 5 (2) v La = 1.15 L k (3) v max = k v La v max CFM 2.5 x CFM ( ) 2 d d ( ) 73 +1 v La = Fan constant. = Average velocity across the width of the spread L feet from the fan (Feet per minute). = Maximum velocity L feet from the fan (Feet per minute). = Free Air Delivery of fan. 5

HartKool Series HKA Features Venturi orifice ring provides rigidity to the fan housing as well as the Hartzell exclusive propeller Tip Seal for lowered horse-power requirements and improved airflow. More usable air/kwh. Fewer fans for same effect. More rugged construction than basket-type fans. Reliable performance ratings. All HartKool fans are performance tested in an AMCA accredited test facility in accordance with AMCA Standard 230 (Laboratory Methods of Testing Air Circulator Fans for Rating). Efficient cast aluminum, airfoil propeller. Front and rear, OSHA approved removable guards. Available in black or safety yellow. 18'' and 24'' available in black; 32'' and 36'' available in safety yellow. Large, predictable volume of air. Quiet operation. Available in 115/230 single phase, dual voltage motors. Thermal overload; totally enclosed, air over construction, 6' grounded cord, two-year warranty on motor. Product Uses: Spot cooling Air circulation eliminate dead spots, break up stagnation, reduce condensation Heat stress relief Series HKA Rating Table Series HKA Motor Amps CFM Approx. Size Model HP RPM @ 115/60/1 @ 0" S.P. db A @ 5' 18 _HKAB-182NB---PLYAEC 1/3 1700 3.0 4236 71 24 _HKAB-242NB---PLYAFC 1/2 1700 7.0 8480 77 32 _HKAY-322NA---PLYAFD 1/2 1100 6.0 11187 71 36 _HKAY-362NC---PLYAFD 1/2 1100 6.0 13450 74 (File note: dba values are Q=1.) Available in HRS Stock Program. Principal Dimensions Series HKA Fan Size/Item Length Width Depth Ship Wt. 18 22 3 8 22 3 8 11 1 2 33 lbs. 24 29 29 12 13 16 47 lbs. 32 37 37 13 19 32 86 lbs. 36 42 3 8 42 3 8 14 7 16 100 lbs. Mounting Hook - Small (18" & 24") 12 2 3 2 lbs. Mounting Hook - Large (32" & 36") 23 2 3 3 lbs. Wall/Ceiling Bracket 24 1 1 2 16 12 lbs. Wheeled Cart* 42 24 29 45 lbs. Low Pressure Mist Kit 1 lb. *Ships unassembled. 6

HartKool Accessories Wall/Ceiling Bracket Permanently mount the HartKool from posts, walls, and ceilings. Low Pressure Mist Kit with Optional Ground Fault Interrupter For evaporative cooling. Female coupling attaches to tap or garden hose. Ring has brass and stainless steel nozzles with a 5 ft. lead line. Available for 18", 24", 32" and 36" fans. Wheeled Cart* Makes the HartKool a truly port-able fan, ready to go where you need it most. Holds one fan (any size) or two 18" or 24" fans. *Ships unassembled. Model Code Example HartKool S H K A B 24 2 N B P L Y A F C Type A Production Item S Stock Item Q Special Quote Product Series Color (HartKool only) Size (nominal wheel diameter, inches) Class/ Blades (class for centrifugals; blades for axial) Wheel Code Wheel Width/ Blade Angle (width (%) centrifugals/ angle axials) Material of Construction Motor Enclosure Motor Horsepower Motor RPM/ Phase Motor Horsepower Horsepower 1/3 1/2 Code Letter E F Colors: B Black Y Safety Yellow Fans Motor RPM/ Phase 1 Phase C = 1700 D = 1100 Material of Construction: PL Polyethylene (all sizes) How To Use Model Code Index: Example Assume a required performance of 8480 CFM at Free Air, at standard conditions. Reading the rating table on page 6, we find a HartKool Fan, 24" size, with 8480 CFM at Free Air. This unit has a 2 blade propeller. Required motor horsepower is 1/2. The model code can be constructed as follows: Type will be a stock item (code S), product series for the HartKool Fan is HKA (color is black), size of the wheel is 24", number of blades is 2, blade is NB. material of construction is plastic (code PL), motor is totally enclosed, air over yoke mount (code YA), motor horsepower is 1/2 (code F), and motor RPM/phase is 1100 RPM/1 Phase (code C). Note: All other informational fields must be filled with hyphens/dashes ( ) if they are not applicable to the fan being considered. 7

Hartzell Warranty LIMITED WARRANTIES Hartzell represents to Buyer that any goods to be delivered hereunder will be produced in compliance with the requirements of the Fair Labor Standards Act of 1938 as amended. Hartzell also warrants to Buyer its goods to be free from defects in workmanship and material under normal use and service for one (1) year after tender of delivery by Hartzell, plus six months allowance for shipment to approved stocking dealers and distributors. No warranty extends to future performance of goods and any claims for breach of warranty or otherwise accrues upon tender of delivery. The foregoing constitute Hartzell s sole and exclusive warranties and are in lieu of all other warranties, whether written, oral, express, implied or statutory. LIMITATION OF LIABILITY FOR BREACH OF WARRANTY Hartzell s obligation for any breach of warranty is limited to repairing or replacing, at its option, without cost to Buyer at its factory any goods which shall, within such a warranty period, be returned to it with transportation charges prepaid, and which its examination shall disclose to its satisfaction to have been defective. Any request for repair or replacement should be directed to Hartzell Fan, Inc., P.O. Box 919, Piqua, Ohio 45356. Hartzell will not pay for any repairs made outside its factory without its prior written consent. This does not apply to any such Hartzell goods which have failed as a result of faulty installation or abuse, or incorrect electrical connections or alterations, made by others, or use under abnormal operating conditions or misapplication of the goods. LIMITATION OF LIABILITY To the extent the above limitation of liability for breach of warranty is not applicable, the liability of Hartzell on any claim of any kind, including negligence, for any loss or damage arising out of or connected with, or resulting from the sale and purchase of the goods or services covered by these Terms and Conditions of Sale or from the performance or breach of any contract pertaining to such sale or purchase or from the design manufacture, sale, delivery, resale, installation, technical direction installation, inspection repair, operation or use of any goods or services covered by these Terms and Conditions shall, in no case exceed the price allocable to the goods or services which gave rise to the claim and shall terminate one year after tender of delivery of said goods or services, plus six months allowance for shipment to approved stocking dealers and distributors. In no event will Hartzell be responsible or liable for any labor or other incidental costs associated with the removal or replacement of defective products or materials. In no event whether as a result of breach of contract, or warranty or alleged negligence, defects, incorrect advice or other causes, shall Hartzell be liable for special or consequential damages, including, but not limited to, loss of profits or revenue, loss of use of the equipment or any associated equipment, cost of substitute equipment, facilities or services, down time costs, or claims of customers of the Buyer for such damages. Hartzell neither assumes nor authorizes any person to assume for it any other liability in connection with the sale of its goods or services. NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS HARTZELL DOES NOT WARRANT THAT SAID GOODS ARE OF MERCHANTABLE QUALITY OR THAT THEY ARE FIT FOR ANY PARTICULAR PURPOSE. THERE IS NO IMPLIED WARRANTY OF MERCHANTABILITY AND THERE IS NO IMPLIED WARRANTY OF FITNESS. Propeller Fans Cooling Tower & Heat Exchanger Fans Duct Fans Duct Axial Fans Vaneaxial Blowers Cool Blast & Utility Fans Steel Centrifugal Blowers Roof Ventilators Steel & Fiberglass Heating Equipment Gas & Steam Fiberglass Axial Flow Fans Fiberglass Centrifugal Blowers Hartzell Fan, Inc., Piqua, Ohio 45356 Plants in Piqua, Ohio and Portland, Indiana. Marine Mine Duty Blowers Litho in U.S.A. A-120-O 11/08