Titrette. class A precision. The next generation Digital Burette!

Similar documents
Titrette. class A precision. 10 ml. New. size. The next generation Digital Burette!

Titrette. class A precision. The next generation Digital Burette!

N E W! The next generation Digital Burette.

Liquid Handling Easy Handling! Titrette. Gebrauchsanleitung. Operating Manual. Mode d'emploi. Instrucciones de manejo

User Manual Electronic Titrator

Perfect Liquid Handling PRECISE RESULTS WITH INNOVATIVE TECHNOLOGY

The Measure of all Things. Volumetric Solutions from Merck

DURAN GROUP DISPENSER & DURAN GROUP DISPENSER PRO. A safe and precise dispensing system

TITREX. One instrument for all your titration and dosing applications

Liquid Handling DIN EN ISO DE-M

Dispensette. Testing Instructions (SOP) 1. Introduction. May 2009

JADE Bottle Top Dispenser

Operation Manual BOTTLE TOP DISPENSER

Liquid Handling. iclab.com.au / iclab.co.nz

For any application the right Dispensette. Dispensette III Dispensette Organic Dispensette HF

Titrette and Digital Burette

ISO-9001:2008 DISPENSERS CATALOG. Phone: Fax: Web:

ceramus HiClass in dispensing.

ceramus HiClass in dispensing

VITLAB Dispenser. Standard Operating Procedure (SOP)

Water analysis, QC and more:

Digital Burette. Assembly and operating instructions. For capacities of 30ml & 50ml

Transferpette. Testing Instructions (SOP) 1. Introduction. October 2013

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

Competence in Labware. Liquid-Handling range

Prospenser. User Manual Mode d emploi Bedienungsanleitung Manual Usuario. For capacities of 2.5 ml 5 ml 10 ml 30 ml and 50 ml

Competence in Labware. Liquid-Handling range

Eppendorf Repeater Pro Instruction Manual Manual de Instrucciones

SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor

Perfection in Liquid Handling PRECISE AND CONVENIENT PIPETTING

Quality from the very start. BLAUBRAND.

PRIEMONIŲ IŠPARDAVIMAS

Conductivity Measurement CLM 280

PROPOSED REVISION OF THE GENERAL CHAPTER 1.11 COLOUR OF LIQUIDS. for The International Pharmacopoeia

INVITATION FOR QUOTATION. TEQIP-III/2018/mmug/Shopping/29 To,

MM PISTON PUMP

MM PISTON PUMP

Efficiency in variable pipetting

Electronic Limit Switch Type

Application Data Sheet. Chemical Compatibility Chart. IND-AS EN-01 (May, 2014) Metals Plastics Seals KEY. Good. Fair. Ethylene Propylene.

Operating Manual for. Dispenser. Read this manual thoroughly before operating the Labmax Bottle Top Dispenser!

Competence in lab plastics. MEASUREMENT ACCURACY TO THE HIGHEST DEGREE

SAMPLING CONTAINERS & HOLDING TIMES. Parameters Method Holding Time 8 Minimum Volume Water Sampling Water Soil Water Soil Container Preservative 9

8.0 pipet4u pipets General Information

TORRIX Magnetostrictive level sensor

PAT941 Smart Titrator. Potentiometric Analysis Titrator

ISTEC MAGNETIC METERS

The ML-T Balance Line Reliable results Easy operation Compact and convenient. Big Features Go Compact Worry-free Weighing

TopPette Mechanical Pipettes

Liquid Handling DIN EN ISO DE-M

WHEATON. SOCOREX Acura electro Pipettes Your Electronic Choice. A World of Pipetting Expertise with SOCOREX.

Hydraulic Deadweight Tester Model CPB5800

Technical Data Sheet

MiniLab EL Series for High Performance Engine Development and Maintenance

ASTM Methods that are feasible with Metrohm instruments

Pursuing high precision, speed, and ease of use

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

INSTRUCTION MANUAL HI 921 AUTOSAMPLER

Premium Design - Premium Performance - Premium Quality

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Incubators. Incubators

Liquid Handling Easy Handling! Transferpette. electronic. Gebrauchsanleitung Operating Manual Mode d'emploi Instrucciones de manejo

Touch plate serial number. Please save this info here for use later:

TEST REPORT: CHM12-01-LSM

150 Series Brass Horizontal Float Valve. Technical Information

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

electronic micropipettes

Instruments for the Analysis of Petroleum Products. Oxidation Stability

Safety Products brochure 11 Int INDEX. Exhaust Filters 2. Air Inlet Valve 5. GL45 Caps 6. DIN50 Caps 8. GL38 Caps 10. DIN60 Caps 11.

In-line sampling system for representative sampling without process interruption

VERITY Purification Systems Build the perfect system to fit your research

Small on price, big on boot

Interface I-300 / I-300 Pro Technical data sheet

Liquid Handling DIN EN ISO DE-M

Pump kits. We deliver values.

Paddle-wheel flow controller for On/Off control

Contents. Zippette Pro Bottle-top Dispensers Safetypette Pipet Filler...4. Zippette Pro Bottle-top Dispenser Accessories...

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

Monitor Chlorine in Crude at Sub-ppm Levels

MDP 1000 OPERATING INSTRUCTIONS PUMP MDP 1000 OPERATING INSTRUCTIONS

Model 2053 Conductivity Meter Instruction Manual

SITRANS F flowmeters. SITRANS F R Meters for lubricating oils (distribution of mineral oils) 4/350 Siemens FI Overview

In-line sampling system for representative sampling without process interruption

Automated Globe Valves. BOA-H Mat P PN 16/25 DN Type Series Booklet

When you need to be Sure, be Sure to be Ready! Warranty does not cover any shipping. Berm must be shipped back to factory prepaid.

Pump Kits. More than just pumps

Liquid Handling.

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

Phone: Fax: More information:

Safety Products brochure 11 Int INDEX. Exhaust Filters 2. Air Inlet Valve 5. GL45 Caps 6. DIN50 Caps 8. GL38 Caps 10. DIN60 Caps 11.

SPG-DIGI. Operating Instruction. Please read carefully before use!

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

Differential pressure transmitter PASCAL Ci4 Delta P

GRUNDFOS alldos product information. The digital diaphragm dosing pump for difficult liquids

PVC Quick Drain Valve

Operation Manual Woltman. Operation Manual WOLTMAN Water Meters

806 Exchange Unit. Manual EN

Torque transducers the complete range for all tasks. Sensors and transducers

Callisto 100. Cold Filter Plugging Point Tester

2/2 way Angle-Seat Valve for medium up to C, DN15-50

Transcription:

The next generation Digital Burette! Titrette class A precision F I R S T C L A S S B R A N D With the Titrette bottle-top burette, you can titrate quickly and reliably with highest precision, even in close quarters, with no power hookup needed in the lab, in production, or in the field! High accuracy Precise titration within the error limits of Class A Smooth, low-force operation For sensitive, drop-wise titration Compact design Light and stable Easy handling No switching between 'fill' and 'titrate' Simple maintenance Cleaning and part replacement right in the lab PC interface (optional) Data transmission directly to the PC

A closer look The control elements of the Titrette bottle-top burette have an intuitive layout. Separate buttons for On/Off and Pause; Clear button allows user to reset the display and select functions. Easy-grip hand wheel action and smooth precision gears for fast or drop-wise titration make handling extremely simple and reliable. Digital display CLEAR/Select button PC interface (optional) (see ordering information) Replaceable batteries On/Off button Pause button Hand wheels Inspection window Piston Dispensing cylinder Titration and recirculating valve Titrating tube horizontally and vertically adjustable, with integrated discharge valve Valve block Freely rotating (Bottle thread GL 45) Recirculating tube Screw cap Telescoping filling tube

Extras Four additional helpful electronic functions make your work easier. Hold down the CLEAR button to select the desired function: Adjustment with Easy Calibration With Easy Calibration technology, you can easily make calibration adjustments of the instrument 'at the push of a button'. No tools needed! An adjustment may be necessary if the instrument has been in use for a longer period or if parts are replaced. To show that an adjustment has been carried out, a small 'CAL' icon will be shown in the upper portion of the display. Calibration schedule To save a date for the next calibration, simply store it under 'GLP'. The date can be called up each time the instrument is turned on. Hold the on/off button down for a little longer, and the letters GLP, along with the month and year of the calibration date, are shown. Save power with Auto Power Off The instrument switches off automatically after longer periods of inactivity. The current display value is stored, and returned to the display after the power is switched on again manually. Under "APO" (Auto Power Off), you can set the time until automatic power-off from 1 to 30 minutes. Changing decimal place settings For use as a microburette, you can switch the titrated volume display from 2 to 3 decimal places under 'dp' (decimal point). Above 20.00 ml, the display automatically switches to 2 decimal places.

Easy Handling With the Titrette bottle-top burette, you can titrate drop-wise with great sensitivity. No switching needed between filling and titrating! The instrument is light-weight, compact, and can be dismantled for cleaning and maintenance in the lab. Easy handling! Smooth operation! The large, easy-grip hand wheels are conveniently easy to turn. With the optimized gear ratio, you can fill the device quickly and titrate drop-wise with great sensitivity. Class A precision! The Titrette bottle-top burette has an innovative new measuring system which matches the Class A accuracy of glass burettes and, if needed, can offer the precision of 3 decimal places below 20 ml. This is an important feature for users who need to work within the Class A error limits of glass burettes according to DIN EN ISO 385 (e.g., in pharmaceutical work). No switching needed! To change between filling and titration, no switching is needed. The instrument automatically detects whether you are filling or titrating by the direction of hand wheel rotation greatly reducing the risk of handling errors. Pressing the Pause button allows you to interrupt the titration if priming was incomplete. Simply push the button again to resume titration.

Easy Handling User seviceable! We have designed the instrument to be disassembled quickly and easily in a matter of minutes for cleaning, to replace the piston/cylinder, or to replace the batteries. Now you can carry out maintenance conveniently and easily in the lab, and in a few minutes the instrument is ready to go again! Light protection! For protection of light-sensitive media, you can replace the clear inspection windows with the amber colored windows (included). It's quick and easy, because the windows just clip into place. Light-weight and compact! All components move within the housing, reducing headroom requirements. The compact design and the light weight ensure good stability. The titrating tube can be adjusted horizontally and vertically. This provides flexibility when positioning the instrument, e.g., when using a magnetic stirrer or different bottle sizes.

Technical data Comparison of error limits Titrette bottle-top burette Bottle-top burettes acc. to DIN EN ISO 8655-3 Glass burettes Class A acc. to DIN EN ISO 385 Volume ml Partial volume ml A* ± % µl CV* % µl A* ± % µl CV* % µl EL** ± µl 25 25 0.07 18 0.025 6 0.2 50 0.1 25 30 12.5 0.14 18 0.05 6 0.4 50 0.2 25 30 2.5 0.70 18 0.25 6 2 50 1 25 30 50 50 0.06 30 0.02 10 0.2 100 0.1 50 50 25 0.12 30 0.04 10 0.4 100 0.2 50 50 5 0.60 30 0.20 10 2 100 1 50 50 * Error limits related to the nominal capacity (= maximum volume) indicated on the instrument, obtained when instrument and distilled water are equilibrated at ambient temperature (20 C/68 F) and with smooth operation. ** Error limit: EL = A + 2CV (A = accuracy, CV = coefficient of variation, EL = error limit) The maximum resolution of the display: 25 ml instrument: 0.001 ml, above 20 ml titration volume 0.01 ml; 50 ml instrument: 0.002 ml, above 20 ml titration volume 0.01 ml. Material and reagents The instrument can be used for the following titration media (maximum concentration 1 mol/l): Note: If you need an official certification which confirms the error limits that are much stricter than those of DIN EN ISO 8655-3, we recommend a calibration certificate from an accredited calibration laboratory (e.g., the DKD laboratory at BRAND). Acetic acid Oxalic acid solution Sodium arsenite solution Alcoholic potassium hydroxide Perchloric acid Sodium carbonate solution solution Perchloric acid in glacial acetic Sodium chloride solution Ammonium iron (II) sulfate solution acid Sodium hydroxide solution Ammonium thiocyanate solution Potassium bromate solution Sodium nitrite solution Barium chloride solution Potassium bromate bromide Sodium thiosulfate solution Bromide bromate solution solution Sulfuric acid Cerium (IV) sulfate solution Potassium dichromate solution Tetra-n-butylammonium EDTA solution Potassium hydroxide solution hydroxide solution Hydrochloric acid Potassium iodate solution Triethanolamine in Acetone Hydrochloric acid in Acetone Potassium permanganate solution Zinc sulfate solution Iodine solution Potassium thiocyanate solution Nitric acid Silver nitrate solution When the instrument is properly handled, dispensed liquid will only come into contact with the following chemically resistant materials: borosilicate glass, Al 2 O 3, ETFE, PFA, FEP, PTFE, platinum-iridium; PP (screw cap). Limitations of use Chlorinated and fluorinated hydrocarbons or chemical combinations which form deposits may make the piston difficult to move or may cause jamming. Compatibility of the instrument for a special application (e.g., trace material analysis) must be checked by the user. For additional information, please contact the manufacturer. Operating limits This instrument is designed for titrating liquids, observing the following physical limits: +15 C to +40 C (59 F to 104 F) of instrument and reagent Vapor pressure up to 500 mbar Viscosity up to 500 mm 2 /s Altitude: maximum 3000 m above sea level Relative humidity: 20% to 90% The instrument is not autoclavable!

Ordering information Titrette Items supplied: Titrette bottle-top burette, conformity certified, performance certificate, telescoping filling tube (170-330 mm), recirculation tube, 2 batteries (AAA/UM4/LR03), 3 PP bottle adapters (GL 45/32, GL 45/S 40, GL 32/NS 29/32), 2 colored light shield inspection windows, operating manual. Standard with RS 232 interface* Volume Cat. No. Cat. No. 25 ml 4760 151 4760 251 50 ml 4760 161 4760 261 Note: When ordering devices with DKD certificates, the prefix "DKD" must be added to the order number, e.g., DKD 4760 161. * Additionally included: connector cable (Sub-D plug connector, 9-pin), one CD (driver software and open RS232 communication protocol). The CD also includes an example application in XLS-file format, as well as a special operating manual. Storage conditions Store the instrument and accessories at dry conditions. Storage temperature: -20 C to +50 C Relative air humidity: 5% to 95% PC interface (optional) The instrument is available with an optional RS 232 communications interface. Advantages compared to the standard configuration: The titration results are automatically transmitted to the PC by double-clicking on the CLEAR key. This eliminates transcription errors while recording primary data, and complies with an important requirement of GLP. With each data transfer, the burette sends the titrated volume, the serial number of the instrument, the nominal volume and the adjustment value, as well as the next scheduled calibration date. Thus, all raw data is collected. The transmitted data is recognized as keyboard inputs by the PC. This universal input format ensures that the instrument is compatible with all PC applications that accept keyboard inputs. To connect the instrument to a USB interface, simply use a standard USB/RS 232 adapter.

Accessories Spare parts Titrating tube with screw cap and integrated discharge and recirculation valve. Cat. No. 7075 26 Telescoping filling tube FEP. 170-330 mm Cat. No. 7042 04 250-480 mm Cat. No. 7042 05 Filling valve with olive-shaped nozzle and sealing ring. Cat. No. 6636 Inspection window 1 set colorless and 1 set amber colored (light shield). Cat. No. 6783 Piston for vol. 25 ml Cat. No. 7075 30 for vol. 50 ml Cat. No. 7075 32 Dispensing cylinder with valve block for vol. 25 ml Cat. No. 7075 34 for vol. 50 ml Cat. No. 7075 36 For laboratory bottles, and an assortment of adapters, please visit www.brand.de. 9943 55 Printed in Germany 3/0909 Titrette and BRAND are trademarks of BRAND GMBH + CO KG, Germany. Our technical literature is intended to inform and advise our customers. However, the validity of general empirical values, and of results obtained under test conditions, for specific applications depends on many factors beyond our control. Please appreciate, therefore, that no claims can be derived from our advice. The user is responsible for checking the appropriateness of the product for any particular application. Subject to technical modification without notice. Errors excepted. BRAND GMBH + CO KG P.O. Box 1155 97861 Wertheim Germany Tel.: +49 9342 808-0 Fax: +49 9342 808-236 E-Mail: info@brand.de Internet: www.brand.de