Fingerprint/Card Terminal AC-000 V.0 Installation & Wiring uide Doc. Ver. : V.0 Aug.,.0 R&D Center Union Community Co., Ltd.
. Power Connector connection ND (BK) - +V (RE) - P - P - P - Power Adapter Interface ** Insert the Power Cable to /P Terminal Block in right color matching as the picture Installation for AC-000 V.0
. Connecting Ethernet & Power Cable Adapter RJ UTP 0Base-T Switch Hub or Hub ** UTP Connector Installation for AC-000 V.0
. Main Board Feature J0 Communication/ Status Input Interface J0 USB. Host J RF/SC Card J0 Power/ Lock/ Door-phone Interface SW Reset Switch J0 USB. Host 0 J RJ Jack for Ethernet J0 USB.0 Client SW0~0 Lock Type Switch F Fuse SW RS Termination Resistor Select Switch SW RS RS Select Switch SW Debug/IrDA Select Switch Switch Setting I [ Lock Type Selection ] SW0 : ST/M [ Strike/Motor/Dead-bolt Lock ] A/D [ Auto Door / Lock No Power Contact ] SW0 : NO/MT [ Normal Open Relay Contact ] NC [ Normal Close Relay Contact ] SW0 : ST/AT.DR [ Strike, Auto Door, Dead bolt ] MT [ Motor Lock Selection ] SW0, SW0 : Normal [ nd Lock, Emergency Lamp] npwr[ Lock No Power contact ] Switch Setting II [ RS T_Resistor Selection ] SW : ON [ 0ohm termination resistor ] OFF [ Open the termination resistor ] Switch Setting III [ RS RS Selection ] SW : RS [ J0 Pin & Enabled ] RS [ J0 Pin &0 Enabled ] Switch Setting IV [ Debug IrDA Selection ] SW : Debug [ for Developer ] IrDA [ for IrDA ] J0 Power/Door Lock Control Output [Vin ] : DC Power Input [ P ] : round for DC Power [ ] : Door Phone Voltage IN [ ] : Door Phone Signal [ L ] : Lock Output [ LC ] : Lock COM for Output [ L ] : Lock Output [ LC ] : Lock Com for Output [ L ] : round for Lock Control J0 communication/ Status Input [ ]: Inside Open [ ]: Door Monitor 0 [M ]: Door Monitor [M ]: Door Monitor [ ] : round [ Door Status ] [RT]: RS TXD Output [RR]: RS RXD Input [ ] : round for RS [RA]: RS A 0 [RB]: RS B [WI0]: Wiegand Input 0 [WI]: Wiegand Input [WO0]: Wiegand Output 0 [WO]: Wiegand Output [ ] : round [ Wiegand interface ] [ V ] : V Output Installation for AC-000 V.0
. Keypad Board Feature J LCD/AC FPC 0pin J LCD FPC pin J0 FP/Camera/Button FPC 0pin J0 Camera Opposite Side J0 MiC J Touch Screen J0 FP Sensor J Speaker RV0 Door Phone Volume Installation for AC-000 V.0
. Schematic for Door Lock Interface SW0 BSI-0 ST//MT AT.DR LockCon D0 SA LockCon FB0 HH-0JT K0 S--VDC 0 VCC_V C0 0C A K D0 SA Q0 KRC0S VCC_V A K Door Lock Interface C0 0C Q0 KRC0S Lock _COM K0 S--VDC 0 NC LOCK NP SW0 BSI-0 SW0 BSI-0 NP SW0 NML MT BSI-0 NO/MT LOCK SW0 BSI-0 AT.DR/S T LOCK_COM NML C0 0C Terminal Block PIN DC_IN 0 IP_V 0 IP_SI LOCK Lock_COM LOCK LOCK_COM J0 BI--DB0-0 DC_IN DC_nd IP_V(+) IP_SI Lock Lock Com Lock Lock Com nd Installation for AC-000 V.0
. Connection of Wires to terminal blocks J0 communication/ Status Input [V] : V Output [ ] : round [ Wiegand ] [WO]: Wiegand Output [WO0]: Wiegand Output 0 [WI]: Wiegand Input [WI0]: Wiegand Input 0 0[RB]: RS B [RA]: RS A [ ]: round [ Serial Port ] [RR]: RS RXD Input [RT]: RS TXD Output [ ] : round [ Input ] [M ]: Door Monitor J0 Door Lock Control Output [ ] : DC Power Input [ P ] : round for DC Power [ ] : Door Phone Voltage IN [ ] :Door Phone Signal [ L ] : Lock Output [ LC ] : Lock COM for Output [ L ] : Lock Output [ LC ] Lock COM for Output [ L ] : round for Lock Control [M ]: Door Monitor [ ]: Door Monitor 0 [ ]: Inside Open Installation for AC-000 V.0
. Connection of Door Phone pin (RE) Door Phone pin Signal (Blue) pin round (BK) pin Inside Open (OR) ** Inside Open Switch Connection The Installation distance is Max 0M(00feet) between AC-000 and Door Phone. If you want to call the door phone, please use the Call button. The Color is not important. Installation for AC-000 V.0
. Connecting Dead-Bolt Type Door Lock (Fail Safe).. Connect with One System/ One Lock 0 V wo wi RB RA P L LC NC ======== NO/MT ST/MT == AutoDoor Red Black ray reen ND RR RT M M L LC L SW0 SW0 SW0 SW0 Inside Door Open S/W Red Black reen ray : Lock (+) : Lock (-) : Door Monitor (NO) : round (Door Status Com) SW SW0 Inside Open Door Monitor Installation for AC-000 V.0
. Connecting Dead-Bolt Type Door Lock (Fail Safe).. Connect with Two Systems/ One Lock System V wo wi NC ======== NO/MT ST/MT == AutoDoor P System V wo wi NC ======== NO/MT ST/MT == AutoDoor P Red Black ray reen 0 RB RA RR RT M M L LC L LC L SW0 SW0 0 RB RA RR RT M M L LC L LC L SW0 SW0 Red Black reen ray : Lock (+) : Lock (-) : Door Monitor (NO) : round (Door Status Com) SW0 SW0 SW0 SW0 SW SW0 SW SW0 Door Monitor Installation for AC-000 V.0 0
. Connecting Strike Type Door Lock (Fail Safe).. Connect with One system/ One Lock V wo wi P NC ======== NO/MT ST/MT == AutoDoor (-)Black (+)Red 0 RB RA L LC ND RR RT M M L LC L SW0 SW0 SW0 SW0 Inside Door Open S/W SW SW0 Inside Open Door Monitor Installation for AC-000 V.0
. Connecting Strike Type Door Lock (Fail Safe).. Connect with Two systems/ One Lock System NC ======== NO/MT ST/MT == AutoDoor System NC ======== NO/MT ST/MT == AutoDoor (-)Black (+)Red V V wo wi P wo wi P 0 RB RA L LC 0 RB RA L LC RR RT M M L LC L SW0 SW0 RR RT M M L LC L SW0 SW0 SW0 SW0 SW0 SW0 SW SW0 SW SW0 Door Monitor Installation for AC-000 V.0
0. Connecting Strike Type Door Lock (Fail Secure) 0.. Connect with One system/ One Lock V wo wi P NC ======== NO/MT ST/MT == AutoDoor (-)Black (+)Red 0 RB RA L LC ND RR RT M M L LC L SW0 SW0 SW0 SW0 Inside Door Open S/W SW SW0 Inside Open Door Monitor Installation for AC-000 V.0
0. Connecting Strike Type Door Lock (Fail Secure) 0.. Connect with Two systems/ One Lock System NC ======== NO/MT ST/MT == AutoDoor System NC ======== NO/MT ST/MT ===AutoDoor (-)Black (+)Red V V wo wi P wo wi P 0 RB RA L LC 0 RB RA L LC RR RT M M L LC L SW0 SW0 RR RT M M L LC L SW0 SW0 SW0 SW0 SW0 SW0 SW SW0 SW SW0 Door Monitor Installation for AC-000 V.0
. Connecting EM Type Door Lock (Fail Safe).. Connect with One system/ One Lock V wo wi P NC ======== NO/MT ST/MT == AutoDoor (-)Black (+)Red 0 RB RA L LC ND RR RT M M L LC L SW0 SW0 SW0 SW0 Inside Door Open S/W SW SW0 Inside Open Door Monitor Installation for AC-000 V.0
. Connecting EM Type Door Lock (Fail Safe).. Connect with Two System/ One Lock System NC ======== NO/MT ST/MT == AutoDoor System NC ======== NO/MT ST/MT == AutoDoor (-)Black (+)Red V V wo wi P wo wi P 0 RB RA L LC 0 RB RA L LC RR RT M M L LC L SW0 SW0 RR RT M M L LC L SW0 SW0 SW0 SW0 SW0 SW0 SW SW0 SW SW0 Door Monitor Installation for AC-000 V.0
. Connecting EM Type Door Lock (Fail Safe).. Connect with One system/ Two Locks ** Use external DC Power adapter ND 0 V wo wi RB RA RR RT M M P L LC L LC L SW0 SW0 SW0 SW0 NC ======== NO/MT ST/MT == AutoDoor V A Adapter (+) (-) Inside Door Open S/W External (-)Black (+)Red Door Monitor Lock SW SW0 Inside Open Door Monitor Lock Installation for AC-000 V.0
. Connecting Auto-Door (Contact Control).. Connect with One system/ One Door Auto Door Operating Part Auto Door Motor 0 V wo wi RB RA RR RT P L LC L LC NC ======== NO/MT ST/MT == AutoDoor Auto-Door Sensor P CONN Sensor Input Line Auto-Door Monitor M M L SW0 SW0 SW0 SW0 Inside Door Open S/W SW SW0 Installation for AC-000 V.0
. Connecting Auto-Door (Contact Control).. Connect with Two systems/ One Door Auto Door Operating Part Auto Door Motor System NC ======== NO/MT ST/MT == AutoDoor System NC ======== NO/MT ST/MT == AutoDoor Auto-Door Sensor Sensor Input Line Auto-Door Monitor V V P CONN wo wi P wo wi P 0 RB RA RR RT L LC L LC 0 RB RA RR RT L LC L LC M M L SW0 SW0 M M L SW0 SW0 SW0 SW0 SW0 SW0 SW SW0 SW SW0 Installation for AC-000 V.0
. Connecting Mortise Lock.. Connect with Motor Lock V AutoDoor/ST == MT NC ======== NO/MT ST/MT == AutoDoor 0 wo wi RB RA RR RT P L LC L LC Motor Motor Blue : Motor Brown : Motor Orange: Door Monitor White : round Yellow : Unlock Signal Black : round Red : Lock Signal M L M SW0 SW0 SW0 Inside Door Open S/W ** Example : ALM Series. SW0 SW Inside Open SW0 ** Select motor lock st in the Lock setting at the configuration menu. Installation for AC-000 V.0 0
. Connecting Mortise Lock.. Connect with Solenoid Lock V NC ======== NO/MT ST/MT == AutoDoor 0 wo wi RB RA P L LC Lock Blue : Motor Brown : Motor Orange: Door Monitor White : round Yellow : Unlock Signal Black : round Red : Lock Signal RR RT M L LC L Lock M SW0 SW0 SW0 Inside Door Open S/W ** Example : ALTA/ALRA Series. SW0 SW SW0 Inside Open Installation for AC-000 V.0
. Connecting Emergency Lamps NC ======== NO/MT ST/MT == AutoDoor Emergency Lamp Emergency Lamp V wo wi P 0 RB RA RR RT M M L LC L LC L Lock (+) Lock (+) SW0 SW0 V (+) round (-) V (+) round (-) SW0 SW0 SW SW0 Installation for AC-000 V.0
. Connecting Wiegand Output to External Controller Data 0 Data ND V wo wi P External Access Controller Input 0 RB RA RR RT L LC L LC AC000 Supported Formats - bits - bits (Site Code + User ID) = User Card number for controller M M L Installation for AC-000 V.0
. Appendix. RS- Interface V wo wi P round 0 RB RA L LC RS- RXD IN RS- TXD Out RR RT L LC M M L SW SW Communication Port Select S/W : SW RS === RS Installation for AC-000 V.0
. Appendix. RS- Interface V wo wi P RS- B RS- A round 0 RB RA RR RT L LC L LC M M L OFF ON SW SW SW RS- Termination Resistor Select S/W : ON/OFF Select SW Communication Port Select S/W : RS ===== SW RS Installation for AC-000 V.0
. Wiring uide. Terminal & Exit Button Adapter AW0 * C AW * C AW0 * C Server Door CAT. -Pr.(UTP) Switch Hub CAT. -Pr.(UTP) Installation for AC-000 V.0
. Wiring uide. Terminal & Exit Button w/lock Controller Adapter Adapter Lock Controller ( ex.blc-0 ) AW0 * C AW0 * C (Power) AW * C AW * C(RS) Door Server CAT. -Pr.(UTP) Switch Hub CAT. -Pr.(UTP) Installation for AC-000 V.0
. Ferrite Core Attachment on Adapter Cable Attachment the Ferrite Ring Core 0xx on the Adapter cable times as below picture. 0mm +/-0mm turns Installation for AC-000 V.0