PQC - STATCON The ultra fast Power Quality Compensator

Similar documents
PQC-STATCON. PPHVC-Power Quality Solutions. Instantaneous and stepless power quality compensation for dynamic reactive power and unbalanced loads

PPHVC Power Quality Solutions. ABB PQC-STATCON Benefits and advantages

PQdynaC High speed, flexibility and modularity

LV Capacitors QCap-L series Capacitors for power factor correction

PQstorI One stop solution for energy storage and power quality

PQactiF Higher flexibility and modularity for improved power quality

EMPAC Metal enclosed capacitor bank for wind applications

Power Quality Compensator - Reactive (PQCR) Enhancing power quality and energy efficiency of your electrical network

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

&MFDUSJGJDBUJPO Products 1PXFS 2VBMJUZ 'JMUFST 12'* o 12'. o 12'4 )BSNPOJDT NJUJHBUJPO MPBE CBMBODJOH BOE SFBDUJWF DPNQFOTBUJPO PO -7 OFUXPSLT

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality

Modular Standardized Electrical and Control Solutions for Fast Track Projects

ABB central inverters PVS to 2091 kva

Targeted Application of STATCOM Technology in the Distribution Zone

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

Power Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS

Power IT LV Active Filters PQFI - PQFM PQFK - PQFS

Dynamic Reactive Power Control. By V. R. Kanetkar Full Time Consultant Technical Services at Veretiv Energy Private Limited Thane (West)

Voltage limiting device HVL

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

Power Protection Discrete Automation & Motion South Africa

Voltage limiting device HVL

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Product information. ECOSS Electronic compact starter for wound rotor drives

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Medium voltage drive for single or multimotor applications, 3 27 MW

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

ZX-Family Gas-insulated medium voltage switchgear

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS 1.2 to 5.0 kw

EC Gold Series Synchronous permanent magnet motor

EAS822 (Contrac) Power Electronic Unit

Technical News. Power Factor Correction. What technology is best for you? Specialists in electrical and automation products, systems and solutions

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS-Q 1.2 to 5.0 kw

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

More power for railway lines Maximum efficiency with proven system behavior

Contact us. Catalog Low voltage generators for diesel and gas engines Industrial Marine applications - series Standard series

Integration of Large Wind Farms into Electric Grids

ELG4125: Flexible AC Transmission Systems (FACTS)

FINHRM FINHRM5 FINHRMA FINHRMAC

smartvar Dynamic VAR Compensator

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

Power Quality Solutions STATCOM, 100kVAr to 30MVAr Dynamic reactive power compensation

Dynamic Reactive Power Control for Wind Power Plants

Power Quality. Static Var Generator (SVG) SVG Wallmount & SVG Cabinet Mount

PRODUCT BROCHURE. ABB Ability Wireless Monitor for surge arrester Enabling reliability and availability of power supply

Power Quality. Power Factor Wiring and Service. Background. Introduction. bchydro.com

HOKKIM. Control & Protection Relays. giving you control. Utilization: Power Factor Regulator : 14-STEP CYCLIC POWER FACTOR REGULATOR.

Traction systems for Light Rail Vehicles Selected references

NEMA MOTORS. Aggregate motors

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Transformers. Reduced emission painting for transformers Lower volatile organic compound painting systems

Metal enclosed capacitor banks: ABBACUS family

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

Product brochure. Medium voltage AC drive ACS 2000, 4kV 6.9kV HP

ABB i-bus KNX DG/S x DALI-Gateway Basic

When grids get smart ABB your partner for developing Smart Grids solutions

Harmonic current emissions as EN Harmonic Test Value in Amps % of fund Limit value in Amps

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

1.1 Block Diagram of Drive Components of Electric Drive & their functions. Power Processor / Modulator. Control. Unit

Surge arrester POLIM-H.. ND

Marine generators Proven generators for reliable power on board

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Breaker-failure protection RAICA

Manual motor starters Overview and benefits

ABB n.v Power Quality in LV installations

LV Capacitor Bank APC

ZX2 Gas-insulated medium voltage switchgear

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

ADF. Restoring the perfect wave

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

TECHNICAL SPECIFICATION

SINAMICS SM150. Siemens product performance features. Competitor product profile. Components. Power, transport units. Service friendliness

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

Product brochure. Medium voltage AC drive ACS2000, kw, kv

TECHNICAL SPECIFICATION

Baldor-Reliance Food Safe Stainless steel NEMA motors

EU MEPS for low voltage electric motors

Overview Overvoltage protection

BROCHURE. IE4 SynRM motor-drive packages Super premium efficiency for industry

POWER FACTOR CORRECTION USING SHUNT COMPENSATION

MGE TM Galaxy TM 7000 GFC

LV Capacitor Bank APC

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

Short form catalogue Motor protection and control Manual motor starters

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

Low Voltage Systems MNS and MNS is PowerCenter

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

CHAPTER 6 POWER QUALITY IMPROVEMENT OF SCIG IN WIND FARM USING STATCOM WITH SUPERCAPACITOR

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

TECHNICAL DATA SHEET KVA UPS Systemss

ELECTRICAL POWER SYSTEMS 2016 PROJECTS

Implementation of FC-TCR for Reactive Power Control

Three Phase UPS Systems Range: 10 to 500kVA

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Physical Design of a Volt/Var Implementation

ABB November 16, 2016 Slide 1

Transcription:

PQC - STATCON The ultra fast Power Quality Compensator

PQC - STATCON The ultra fast power quality compensator PQC - STATCON is based on IGBT voltage source inverter technology. It is a shunt connected device capable of performing ultra fast dynamic reactive power and unbalance compensation in a smooth step-less fashion. It uses a full closed loop control system to precisely control, regulate and improve the source power quality parameters. PQC - STATCON technology is used for dynamic reactive power compensation, unbalance compensation and voltage stability improvement. Hence it has a wider application, even for the weaker networks. Apart from the grid supply network, it can support dynamic loads operating from generator. PQC - STATCON has a good steady state performance with much faster response and superior control characteristics. It can be operated dynamically to compensate to fast varying capacitive, inductive and unbalanced loads. A typical PQC - STATCON installation is shown in Figure 1. Yellow - STATCON current Blue - Supply Voltage Magenta - Step response Source Real power PQC STATCON Load Unbalance / reactive power Figure 2: PQC - STATCON Dynamic response PQC - STATCON can perform a fast dynamic step change from 100% inductive VAr to 100% capacitive VAr or vice-versa in 1-1.5 power cycles. Fig 2 shows a similar step response of PQC - STATCON with a recorded response rise time of 20.97 ms. Unlike capacitor based reactive power compensation systems, PQC - STATCON can be operated even in highly distorted voltage networks. Figure 1: A typical PQC - STATCON installation PQC - STATCON supplies the reactive and unbalance components of load currents locally. Therefore the PCC and source are relieved from the excessive VAr loading. The source supplies only clean real power and the heating of equipment are reduced, improving the life of plant electrical infrastructure. 2 PQC STATCON Product brochure

PQC - STATCON variants PQC - STATCON is available for single phase and three phase applications as PQCS STATCON and PQCT STATCON respectively. The PQCS STATCON performs fast reactive power compensation based on a target power factor (PF) setting, which can programmed through the user interface. PQCS STATCON also has an option for setting dual PF target (Main/ Auxiliary PF Targets). This option enables the system to work at unity PF (or any other Main PF setting), when supplied from utility source and to work at 0.8 lag PF (or any other Auxiliary PF setting), when supplied from generator. PQCS STATCON is well suited for single phase applications like railway traction substations and automotive welding shops. The PQCT STATCON performs fast reactive power and unbalance compensation for a three phase network. The operation of PQCT STATCON is represented in Figure 3. PQCT STATCON has priority option to perform allocate the converter resources between reactive power and unbalance compensation requirements, in addition to the dual PF target option as in PQCS STATCON. The Priority compensation can be selected to be Reactive Power or Unbalance. If reactive power is selected as priority, PQC - STATCON will compensate for reactive power to the specified target PF and use the remaining resources for unbalance compensation. If unbalance is selected as priority, PQC - STATCON will nullify the unbalance current components in the load and use the available remaining resources for reactive power compensation. In addition to priority setting, the dual PF target option enables the system to work at unity PF (or any other Main PF setting), when supplied from utility source and to work at 0.8 lag PF (or any other Auxiliary PF setting), when supplied from generator. Load current (-) PQCT STATCON current = Source current + + Real current Reactive current Negative sequence unbalance current () Load current + Reactive current Negative sequence unbalance current Real current PQCT STATCON current Source current Figure 3: PQCT STATCON nullifies the reactive & unbalance currents at the source Note: PQCT STATCON is a three wire device. It compensates the phase to phase unbalance currents only. Product brochure PQC STATCON 3

Features PQC STATCON is an advanced, reliable and user friendly solution for power quality problems. It uses robust control and protection techniques implemented on a high speed digital control system. The features of PQC STATCON are discussed as follows. Energy efficient operation Energy save mode is a feature available in PQCS and PQCT range of PQC - STATCONs. If the PQC - STATCON is operating at near zero current levels for 30 seconds, IGBT converter is switched off and successively the blowers are switched off in 2 minutes. The system enters a sleep mode and the stress on power components is minimized. The power consumption of PQC - STATCON in sleep mode is almost zero, but the system is available in hot standby. As the load demand rises, the system can supply the rated kvar within 5-8 power cycles. This mode can be optionally enabled / disabled through the user interface. capacitor bank. Refer figure 4. PQC - STATCON can control the parallel filter banks through a potential free contact, by which energy efficient operation is achieved more efficiently and the system will achieve a dynamic range of -X to +2X kvar. Protection PQC - STATCON has advanced fault diagnostic features to provide a maximum protection level. It is protected against over-current, input supply over/under voltages, over-temperature, unstable grid and many more abnormal operating conditions. The diagnostic feature also monitors the performance of cooling system and any permanent failure of PQC - STATCON system components. The fault history is recorded with time stamping and duration of the fault. The logged history is accessible through the graphical user interface (GUI). Operation with parallel fixed capacitor bank PQC - STATCON has the capability to operate in inductive and capacitive modes. In order to achieve higher kvar, PQC - STATCON may be operated in parallel with a fixed 100% x 100% x 200% 2 x + = 0% -100%-x 0% Statcon Fixed capacitor Total RPC plant Figure 4: Improved economic dynamic range with parallel capacitor bank 4 PQC STATCON Product brochure

Modes of operation The different modes of PQC - STATCON operation are discussed as follows. I L = I Ld, I Lq Fixed compensation mode In this mode PQC - STATCON supplies a fixed lagging / leading reactive current. It functions as a fixed inductive / capacitive reactive current source. The current to be supplied can be set through the user interface. Dynamic modes In dynamic modes PQC - STATCON supplies a dynamic current based on the feedback from CT. It can take feedback from CT located on the source side or load side. I STAT = I Lq + D Figure 5: Open loop configuration I L Dynamic, load CT mode This mode can be selected through the user interface. PQC - STATCON measures the reactive/unbalance component in load current and injects an anti-phase component of the same. Since both the currents are flowing on the same bus, the reactive/unbalance currents drawn by the load is locally compensated. This mode operates on an open loop fashion. When more than one PQC - STATCON are used in parallel, all of them uses the same CT feedback and shares the load demand equally. This mode is useful, when only the loads in a specific feeder are to be compensated and PQC - STATCON is located on a different feeder of the same bus. I g = I L + I STAT (-I Lq ) I g I STAT = (-I Lq ) Figure 6: Closed loop configuration I L = I Ld, I Lq Dynamic, grid CT mode This mode can be selected through the user interface. In this mode PQC - STATCON measures and regulates the reactive/unbalance currents at the source side to zero. This is performed in a closed loop fashion. This is the most widely used, accurate and recommended method, by which the capabilities of PQC - STATCON can be utilized to the maximum. Typical configuration is shown in Figure 6. In most cases more than one PQC - STATCON are used to meet the reactive power requirement. All the PQC - STATCON systems can share the same CT feedback and regulate the source power factor. Figure 7: Operating boundaries of PQCT STATCON (Refer technical specifications - PQC Current for details) Product brochure PQC STATCON 5

Technical specifications Value Parameter Condition/ Remarks Min Typ Max Unit Supply voltage Voltage group 1 208 240 265 Volt Voltage group 2 375 415 455 Volt PQC current Refer ratings table below Amp Temperature -10 45 C 50 Hz operation 47 53 Frequency 60 Hz operation 57 63 Hertz 1no for PQCS Measurement CT Input 3nos for PQCT 5 Amp Parallel PQC STATCON Units 1 8 Nos Target COSø setting -0.6 0.6 - Response time (10% to 90%) 1 1.1 1.5 Cycles Active power At full Compensation 3 % Other Parameters Protection level Humidity Altitude Color Installation Cable Entry Particulars IP30 (Other protection levels on request) Maximum 95% RH, non-condensing Up to 1000m RAL 7035 matt finish (Other colors on request) Floor fixation Bottom (Other options on request) RATINGS PQCS STATCON S. No Type No. Application VOLTAGE kvar Amp (Ir) 1 PQCS-50-V240 1-Ph 240 50 210 2 PQCS-100-V240 1-Ph 240 100 420 3 PQCS-100-V415 1-Ph 415 100 240 4 PQCS-150-V415 1-Ph 415 150 360 5 PQCS-250-V415 1-Ph 415 250 600 PQCT STATCON S. No Type No. Application VOLTAGE kvar Amp (Ir) 1 PQCT-100-V415 3-Ph. 415 100 140 2 PQCT-150-V415 3-Ph 415 150 210 3 PQCT-250-V415 3-Ph 415 250 350 Note: For unbalance and reactive power sharing please refer Fig. 7 Type no. nomenclature : For example. Refer PQCT (S.No. 3) (PQCT - 250 - V 415) Refer PQCS (S.No. 2) (PQCS - 100 - V 240) PQCT 250 V 415 PQCS 100 V 240 3f PQC STATCON 250 kvar to 250 kvar Nominal supply voltage 415 V 1f PQC STATCON 100 kvar to 100 kvar Nominal supply voltage 240 V 6 PQC STATCON Product brochure

Applications PQCS/PQCT STATCONs finds a wide range of applications, where ever the load demands dynamic reactive power / unbalance currents. Typical applications are as follows. Railway/ Traction substations Wind mills Automotive / Welding plant Steel plants / Rolling mills Process industries Sky lifts / Compressor loads Pulp & Paper industries Chemical plants Off-shore drilling Rubber industries Hydro plants Cement factories Water treatment plants Airports / Shipyards Advantages of STATCON Smooth / step-less dynamic reactive power compensation Very fast real-time response (1-1.5 cycles) Complete solution for providing transient free PF correction and load balancing Improving voltage stability for weaker networks / generator fed power supply Dynamic range in both capacitive and inductive directions Useful solution for 1-Ph / 2-Ph / 3-Ph Loads STATCON may be connected through step-down transformer for MV / HV applications Do not require detail system study and no amplification of load harmonics Reduction in system losses Enhancing the life of existing transformers and other electrical equipment Less maintenance as no moving parts Easy to install and commissioning Environmental and user-friendly High system reliability and performance, thanks to transient free and step-less reactive power / unbalance compensation. Product brochure PQC STATCON 7

Contact us ABB Limited PPHV - LV capacitors Plot no. 5 & 6, 2nd phase, Peenya industrial area, Bangalore 560 058, India Phone: +91 80 2294 9334 / 9391 / 9330 Fax: +91 80 22949339 Email: pqc-statcon@in.abb.com NOTE: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its content - in whole or in parts - is forbidden without ABB s prior written consent. Copyright 2009 ABB. All rights reserved. 1HYC412000-300