PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

Similar documents
DMC mA Positioner

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

Electric Modulating Actuator Installation, Operation & Maintenance Manual

12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

Troubleshooting Bosch Proportional Valves

534HS Pressure Transmitter

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

TD1512AX Technical Data. REMOTE MOUNT SOLENOID DRIVER (4-20mA Input Version)

CN0055 & CN0055B DC to DC NEGATIVE RESISTANCE SPEED CONTROL

Electric Actuator Options & Accessories

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

Electronic Proportional (EP) Control for Heavy Duty Series 0/1 Piston Pumps Model 33 Model 39 Model 46. Model 54 Model 64 Model 76

IMO-517 (7027) ISSUE 3/97 ERA12, 25, 50, 83, 125, 167, 208 AND 250 ELECTRIC ACTUATORS INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

CONTROL FEATURES AVAILABLE OPTIONS

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

LLN Series Linear Actuator Installation, Operation & Maintenance Manual

Eaton Electronic Proportional (EP) Control for Medium Duty Piston Pumps

P3 3-STOP POSITIONER IOM

TECHNICAL DATASHEET#TD1516AX 3 AMP SOLENOID DRIVER

GE Sensing & Inspection Technologies

SAFE & SECURE ACTUATOR PRODUCT MANUAL

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

5001TCP SPEED CONTROLLER

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

AF-17 Electronic Positioner Installation, Operation and Maintenance Instructions

CP (Vdc) CP (Milliamp) CP (Slidewire)

th Street, Surrey, B.C. Canada V3W 0A6 Telephone Fax July 2012

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

SM-1000 SERIES ROTARY ACTUATORS

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

5001TCP SPEED CONTROLLER

Continental Hydraulics Installation Manual CEM-AA-A

M9216 Series Electric Spring Return Actuators

Fincor Series 2230 MKII/2240

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

ENGINE GOVERNING SYSTEMS

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

MF /MS Series

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) EN44 and EN88 Non-Spring Return Electronic Actuators

Servo and Proportional Valves

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

Type Type 1001 Transducers. I/P & E/P Transducers

RP-4000 Reserve Power Control

1100 Series Piston Type Differential Pressure Gauges

MAGPOWR Spyder-Plus-S1 Tension Control

POSITION TRANSMITTERS

LTX RF LEVEL SENSOR. Instruction Manual

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

Features IN THIS CHAPTER

Instruction Manual for Barber-Colman Series EA Electric High Torque Actuators

APPLICATION NOTES VALVE CHECKER M

User's Manual O

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

TRAC-3 TENSION READOUT AND CONTROL

17429X.00 SERIES MODELS:

Electric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

GE Energy. The Becker * DNGP: Fail-Safe Protection for Your Gas Pipeline

Electronic Proportional (EP) Control for Medium Duty Piston Pumps

MaxPak Plus Analog DC V S Drive

OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 24 Vac - Modulating Control

Powers TM Controls EA 338 Electronic Actuator

MBDC V. 110VAC Input Brush DC Controller. User s Guide East Landon Drive, Anaheim, CA

1000 Series. Electronic Digital Actuators. Table of Contents

Model 930 Power Control System Instruction Manual

MF Series MS Series

Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Exercise 2: Series-Opposing DC Sources

Boston Gear Ratiotrol DC Motor Speed Control

RESISTIVITY MONITOR/CONTROLLERS

ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only

How to Select the RE Industrial Actuator Part Number

Type 2000 Transducer Product Instructions

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

Installation & Operation Manual

M100F Incremental Motor Actuator R81F Interface Board

SCR Power Controllers

R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators

10V. the rack of the oil pump must be on the

A6Z OPERATING MANUAL

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

ESD5500E Series Speed Control Unit

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

System 350 S350P Proportional Plus Integral Temperature Stage Module

Transcription:

PEAKTRONICS The Peaktronics DC Motor Controller is used for proportional positioning of actuators that use either DC motors or DC solenoids. The wide operating range of the (10 to 30 VDC and loads up to 5A locked rotor for 20 seconds typical) allows operation in a variety of applications. An external command signal of 4-20mA is used to compare to a feedback signal from a potentiometer. The (open) or (close) output will energize, which powers the actuator motor or solenoids, until the feedback signal matches the command signal, at which time the controller's motor output is turned off and the actuator stops. The unit has on-board LED indicators that show which direction the is attempting to move the actuator. The red LED comes on when the unit is attempting to move the actuator toward open. Conversely, the green LED comes on when the unit is attempting to move toward closed. When the command signal is lost or disconnected, the close output will turn on. Non-interactive Zero and Span adjustments allow easy field calibration, and the Deadband adjustment allows control of faster actuators. The unit includes a yellow LED indicator (showing the presence of the 4-20mA command signal), a red LED indicator (for the open output), a green LED (for the close output), and an on-board replaceable fuse (TR5 type, 4.00A time lag 374 Series). Its solid construction body makes it rugged and easy to mount (two #6 through holes are provided). Screw terminals and a wiring diagram on the unit allow for easy field installation. ADDITIONAL FEATURES Capable of using the full range of the feedback potentiometer. DC Motor Controller, 5A MODEL NO. Close Output LED (GREEN) ZERO SPAN PEAKTRONICS Open Output LED (RED) 4-20mA Indicator (YELLOW) Limit switch inputs referenced to ground allows optional limit indicators with form-c limit switches. Compatible with XMA-105 4-20mA Feedback Position Transmitter SERIAL NO. Miniature size fits in the smallest actuators. Operating temperature range of 0 to 70 o C 4-20mA input has built-in current limiting and reverse polarity protection. Optical isolation between the input signal and the DC outputs Dynamic braking eliminates need of mechanical brake to avoid motor coasting. Low standby current (22mA typical) when actuator is not in operation.

OUTLINE FUSE SPAN (+)4-20mA ( _ )4-20mA BAT POS BAT NEG COMMON +5V WIPER GND 2.40" WIRING DIAGRAM LABEL 3.00" DEADBAND ZERO 1.50" 3.00" 0.65" 0.75" #6 clear hole (2) typical BLOCK DIAGRAM +V BAT POS +5V + EARTH 10-30 VDC see WIRE TABLE BAT NEG WIPER GND FEEDBACK POT NOTE: Battery negative must be connected to earth ground at power source. 4-20mA (+) 4-20mA (_ ) POWER / SIGNAL ACTUATOR COMMON NOTE: See output configurations for more information. 2 PEAKTRONICS

DESCRIPTION The is equipped with screw terminals, allowing for easy field wiring. The unit also has a label that provides convenient information for wiring and locating the adjustments. Two mounting holes are provided that allow easy mounting with standard #6 screws. See Outline information for more details. The unit is intended to be mounted in an appropriate enclosure to protect it from the environment. A heater and thermostat should be used where condensation may occur. POWER The positive terminal of the DC power source is connected to the BAT POS terminal while the negative terminal of the source connects to the BAT NEG terminal (see Block Diagram). Transferring DC power can be inefficient, therefore care should be taken to use appropriate wire sizes. The size wire required depends on the locked rotor motor current and the length of wire to be used. See the Wire Table for more information. MOTOR and FEEDBACK POT The and terminals should be connected to a DC motor so that the actuator moves toward the open position with being positive. Conversely, the actuator should move toward the closed position when is positive. When powering solenoids, connect to the solenoid that moves the actuator toward open, while is connected to the solenoid that moves the actuator toward closed. Internally, the connects to BAT POS and to BAT NEG when attempting to move the actuator toward the open position. The opposite occurs when the attempts to move the actuator toward the closed position. Since and MOTOR 2 are alternately connected to BAT NEG and BAT POS, care should be taken not to connect these outputs to any other terminals. The provides a dynamic braking feature that eliminates the need for a separate brake. When the turns off the motor outputs, and are internally connected to BAT NEG; this has the effect of shorting the motor leads together, thus braking the motor motion. This condition also holds true when power is removed from the. In some applications, a brake is required for mechanical reasons, such as avoiding back driving the motor; the is suitable for powering most brakes, however, consult the actuator manufacturer for more information. Many actuators include limit switches that are used to turn off the motor when the extreme ends of travel have been reached. Limit switches should be wired to the LIMIT,, COMMON terminals (see Wiring Diagrams, Output Configurations). If limit switches are not used, and must be connected to COMMON; if this is not done, the will not be able to control the motor outputs. The feedback potentiometer wiper must be connected to the WIPER terminal. One end of the potentiometer is connected to the +5V terminal, and the other is connected to the GND terminal. The potentiometer should be connected so that when the actuator moves towards the open position, the potentiometer's resistance between the WIPER and GND terminals will increase. This can also be measured as a voltage - the voltage between the WIPER and GND terminals should increase when the actuator moves towards the open position. If the potentiometer is wired incorrectly, the typical response of the unit will be to run the actuator to the full open or closed position (the appropriate output indicator will remain on) regardless of the command signal input. The feedback potentiometer should be mounted to provide a proper feedback signal through the entire range between the open and closed positions. For best results, position the actuator to the midway point between the open and closed positions; then adjust the feedback potentiometer for approximately 2.5 VDC (or 1/2 of the potentiometer's resistance) between the WIPER and GND terminals. Since the feedback potentiometer is crucial for proper operation of the, the following items should be carefully observed: 1 - Potentiometer resistance should be a value from 1K to 10K ohms. 2 - The potentiometer should be a linear taper type. 3 - The potentiometer must be properly wired to provide the correct feedback signal. 4 - The potentiometer must be properly and securely mounted in order to provide a reliable feedback signal. COMMAND INPUT and INDICATOR The is designed to be controlled with a standard 4-20mA signal. The input is optically isolated from the DC power line and includes built-in current limiting and protection against reverse polarity. The input can PEAKTRONICS 3

be connected in series with any part of the current loop (sinking or sourcing outputs). The unit is equipped with a yellow indicator that will turn on whenever the 4-20mA signal is connected. If the input signal is lost, the indicator will turn off, and the close output will turn on (moving the motor to the full closed position). OUTPUT INDICATORS The has on-board LED indicators that identify when one of the motor outputs is turned on. When the output is turned on, the red LED will turn on to indicate that the unit is trying to power the actuator toward open. When the output is turned on the green LED will turn on to indicate that the unit is trying to power the actuator toward closed. See the Outline drawing for location of the LED's. Many actuators are equipped with limit switches at the open and closed positions which are intended to disconnect power to the motor to prevent mechanical damage. For this reason, it is possible that the will indicate that one of the motor outputs is turned on when the actuator is not in motion. CALIBRATION The non-interactive zero and span adjustments of the allows for easy calibration once the unit is installed. After insuring that the feedback potentiometer and motor outputs are wired to provide a proper feedback signal, as described under "MOTOR and FEEDBACK POT", follow these steps to calibrate the unit (see Outline for the location of the adjustments): 1 - Apply DC power to the unit, and set the command input signal to 4 ma. 2 - Adjust the "Zero" adjustment so that the actuator moves to the desired closed position. If the desired position cannot be achieved, check that the feedback potentiometer provides a feedback signal as described under "MOTOR and FEEDBACK POT"; also, check the position of the limit switches. 3 - If the actuator is hunting for position, turn the "Deadband" adjustment clockwise until hunting stops. If the actuator is not hunting for position, turn the "Deadband" adjustment counterclockwise until the actuator begins to hunt; then turn the "Deadband" adjustment slightly clockwise until hunting stops. WARNING! Actuator failure may occur if the "Deadband" adjustment is set to allow continuous hunting. This can cause excessive wear of motor bearings, gear train, dynamic brake, and feedback potentiometer. Hunting can also cause the internal temperature of the actuator housing to rise to a level that exceeds the maximum rating of the DMC- 101, 70 o C. 4 - Set the command signal input to 20 ma. 5 - Adjust the "Span" adjustment so that the actuator moves to the desired open position. If the desired position cannot be achieved, check the position of the limit switch. NOTE: The "Zero" adjustment is an offset setting rather than an absolute setting. Should the "Zero" adjustment be changed, the "Span" adjustment should be checked for the desired open position. Setting of the "Span" adjustment has no affect on the "Zero" adjustment. 6 - To check proper operation and linearity, set the command signal to 12 ma, and verify that the actuator's position is midway between the open and closed positions. REVERSE ACTING CALIBRATION When converting a direct acting actuator to a reverse acting actuator, three changes in wiring must be made: 1 - Reverse the feedback potentiometer wires connected to +5V and GND. 2 - Reverse the motor wires connected to and. 3 - Reverse the limit switch wires connected to the and terminals. NOTE: DO NOT reverse the input signal polarity. After the wiring changes have been made, refer to CALI- BRATION for setting the zero and span adjustments. 4 PEAKTRONICS

WIRING DIAGRAMS Output Configurations +V COMMON optional thermal switch optional torque switch SWITCH optional limit indicators +V SWITCH DC Motor Control Output SOLENOID 3W maximum P EA EB A B ACTUATOR COMMON CLOSE SOLENOID 3W maximum DC Solenoid Control Output PEAKTRONICS 5

WIRING DIAGRAMS Special Applications BAT POS BAT NEG CLI-100 CURRENT LOOP INDICATOR EARTH 4-20mA Monitor 4-20 WIPER W +5V XMA-105 GND FEEDBACK POT Connecting a Position Feedback Transmitter SOLENOID 3W maximum LIMIT COMMON P EA EB A B ACTUATOR *NOTE: connect battery power as usual: 10-30VDC to BAT POS and BAT NEG. BAT POS* WIPER GND Intrinsically Safe Barriers 4-20 ma + CLOSE SOLENOID XMA-104A -/BL 3W maximum R WH FEEDBACK POT CONTROL PANEL 250 ohms (1-5V) NEMA 4 ENCLOSURE Intrinsically Safe Solenoid Controller 6 PEAKTRONICS

WIRING DIAGRAMS Special Applications 4-20mA Command Signal 520 Ω LOAD Calibrate unit #1 to open and close with 4 to 12 ma, and unit #2 to open and close with 12 to 20 ma. Note, the ratio between the feedback pot rotation to the actuator shaft rotation must be 1:1. 4-20mA Input 4-20mA Input #1 Motor NOTE: Limit switches must be used to stop actuator travel! #2 Motor MOTOR2 Split range control PEAKTRONICS 7

WIRE TABLE The table below shows the maximum recommended distance (in linear feet) between the battery source and the unit. The maximum distance is limited by the wire size used and the locked rotor current of the motor. All signal wires on the should be connected with wires sizes ranging from 22 to 18. ft Wire Size Locked Rotor Current (Amps) 18 16 14 12 (see Note 1) 10 (see Note 1) 8 (see Note 1) 6 (see Note 1) 1 133 211 337 535 847 1353 2151 2 66 106 169 268 424 677 1076 3 44 70 112 178 282 451 717 4 33 53 84 134 212 338 538 5 27 42 67 107 169 271 430 NOTES 1) The terminal strip will not accept wire sizes larger than 14. Use a short run of 14 from the to an auxiliary terminal block when larger wire is needed. 2) If the motor is located some distance from the, add this length to the overall wire length; be sure to use an appropriate wire size to the motor. 3) When multiple actuators are powered by a common set of wires, use the sum of all the motor currents when determining wire size. www.peaktronics.com PEAKTRONICS, Inc. 1363 Anderson Clawson, MI 48017 Phone (248) 542-5640 FAX (248) 542-5643 800-90C