Racor 75500FGX Turbine Series fuel

Similar documents
75500MAX Series and 75500MAXM Series

Product Features: Removes 99% of free water. Available with 2, 10, or 30 micron Aquabloc II media

320R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev.

120RMAM Marine Series Fuel Filter/Water Separators

660R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev F

900MA/MAM and 1000MA/MAM (for marine applications)

400 Series Spin-on Fuel Filter/Water Separators

Product Features. Easy installation. Pump adds only 3.3 to the overall assembly height. 60 GPH (227 LPH) flow rate while in priming mode.

Marine Gasoline Products

Marine Fuel Filtration. Marine Turbine Series. Stage One: Separation. Stage Two: Coalescing. Stage Three: Filtration. And more

Marine Fuel Filtration Marine 800 Series

All Racor filter materials and seals are compatible with ultra-low sulphur diesel (ULSD) fuel and B2 to B20 Biodiesel. See Racor bulletin 7679.

900FH and 1000FH Turbine Series Fuel Filter/Water Separators Installation, Operation, and Service Information

Marine Turbine Series

Introduction. Marine Turbine Series. Model Illustrations. Special Notes. Specifications 77/1000MA 73/1000MA 75/500MAX 75/900MAX 79/1000MAV 75/1000MAX

Marine Fuel Filtration. Marine FBO. Features:

General The Racor Marine Diesel Spin--on Series feature a variety of compact sizes to fit most installations and cramped engine compartments.

Flow Control Valves Check Valves Gauge Control Valves. Colorflow Valves

# and # FAST Fuel System Kits

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

DY Series 1-Piece Ball Valves. Catalog 1001C-A. July 2012 欧陆传动

AEROMOTIVE Part # and F-Body Fuel System Kit INSTALLATION INSTRUCTIONS

FPS-500. Fuel Polishing System Eliminates Microbial Contamination. Operating Manual

AEROMOTIVE Part # Mustang 5.0L Fuel System Kit INSTALLATION INSTRUCTIONS

High Pressure Gear Pumps & Motors Series PZG Pumps Series MZG Motors

AEROMOTIVE Part # & Generic Fuel System Kit INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # Generic EFI Fuel System INSTALLATION INSTRUCTIONS

3V SERIES SOLENOID VALVE

MARINE. Diesel Fuel/Water Separators. Installation. Operation. Parts. Service Information

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

4V130P-430P SERIES AIR PILOT VALVE

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Colorflow and Ball Valves. Industrial Flow Control, Check, Gauge Control. Catalog HY /US

DIESEL FUEL FILTER/WATER SEPARATORS & Recycler Systems

STC 2W Series Solenoid Valves

STC 2L Series Solenoid Valves

Dual/Triple Manifold Water Filtration Systems Instruction Manual

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

Section: B Marine Fuel Filtration

Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC

Model Combustible Gas Sample Draw Detector Head Operator s Manual

Marine Retail Basics. Product Overview

TORK DIESEL FILTER/WATER SEPARATOR

18324 INSTALLATION INSTRUCTIONS 65 PONTIAC LEMANS

Figure 1: HB Series Ball Valve Cross Sectional View DISASSEMBLY WARNING: MAKE CERTAIN THE SYSTEM IN WHICH THE VALVE IS INSTALLLED IS EXHAUSTED OF ALL

TANK MONITOR SYSTEMS DTM04 TANK MONITOR DTM08 TANK MONITOR DTM12 TANK MONITOR INSTALLATION AND OPERATION MANUAL

DVX-DUPL DFS DVF-64, DVF-65 DVX. CLEANDiesel Vessels, Housings & Skid Systems DVF-64, DVF-65, DVX, DV, DVF, DFS

Model Combustible Gas Sample Draw Detector Head Operator s Manual

BMK-30. Heavy-Duty By-Pass Filtration System Installation and Servicing Instructions

QUALITY MISTING PUMPS

AEROMOTIVE Part # & ½ L DOHC Return Style Fuel System Kit INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # HP Hot Rod EFI Kit INSTALLATION INSTRUCTIONS

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007

FUEL KITS P/N & 526-4

Diesel Pro FH235, FH236 and FH241 Series Filter/Separator/Warmer Installation Instructions

OWNER S MANUAL AUTOMATIC DISCHARGE PUMP CONTROLLER

AEROMOTIVE Part # & Mustang 5.0L Stealth Fuel System Kit INSTALLATION INSTRUCTIONS

Fuel Pro Series Filter/Separator/Warmer Installation Instructions

AEROMOTIVE Part # Street Rod Fuel Pump System INSTALLATION INSTRUCTIONS

HP FUEL PUMPS P/N ERL & ERL Installation Instructions 199R11108

STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Model Combustible Gas Sample Draw Detector Head Operator s Manual

Owner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.

WARNING User Responsibility

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

Service Manual Series F12

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

11101, & INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Installation & Service Instructions

18318 INSTALLATION INSTRUCTIONS CHEVROLET IMPALA

Quick Coupling Products

PARTS AND INSTALLATION MANUAL

Models P, P, P, , DANGER

AEROMOTIVE Part # Fuel System Prime Kit INSTALLATION INSTRUCTIONS

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Check Valves (CO Series) Catalog 4130-CO Revised, June 2001

Section: D Alternative Fuel

Introduction Parker are designed for uni-directional flow control of fluids and gases in industries such as chemical processing, oil and gas productio

DESCRIPTION MECHANICAL FUEL PUMP FUEL FILTER HIGH PRESSURE (35-90 PSI) HIGH PRESSURE (35-90 PSI) (STEEL/INCLUDED)

Dual Flow Manifold Systems Instruction Manual

Sniper EFI Fuel Kits P/N 526-5/526-8 (20 ft. hose) & (40 ft. hose)

18660, 18661, & Stealth Fuel Cell INSTALLATION INSTRUCTIONS

Model 100 Series Kits

GreenMAX. Heavy-Duty, High-Capacity, Fuel Filter/Water Separator With Options for All-Weather Operations

Installation, Operating and Maintenance Manual

AEROMOTIVE Part # & Mustang 5.0L Fuel System Kit INSTALLATION INSTRUCTIONS

Pneumatic Division North America Richland, MI 49083

Outdoor Bottle Fillers

HP FUEL PUMPS P/N & Installation Instructions 199R10569

Thank You. for purchasing an Edelbrock Nitrous Oxide Injection System. Please take the time to read and understand the following.

Industrial Pro FH234 Series Filter/Separator/Warmer Installation Instructions

Viscount I Hydraulic Motor and Displacement Pump

Xtreme Air Command. Step 1 Prepare the components. Step 2 Select a mounting location. Parts list

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Transcription:

Installation Instructions 75500FGX Fuel Filter Racor 75500FGX Turbine Series fuel filter/water separator assemblies are designed to be installed on the vacuum side of the fuel transfer pump for best efficiency and protect precision engine components from dirt, rust, algae, asphaltines, varnishes, and especially water, which is prevalent in engine fuels. They remove contaminants from fuel using the following legendary three stage process: Stage One: Separation As fuel enters the filter assembly, it moves through the centrifuge and spins off large solids and water droplets which fall to the bottom of the collection bowl. Stage Two: Coalescing Small water droplets bead-up on the surface of the conical baffle and cartridge element. When heavy enough, they too fall to the bottom of the bowl. Stage Three: Filtration Proprietary Aquabloc II cartridge elements repel water and remove contaminants from fuel down to two micron (nominal). They are waterproof and effective longer than water absorbing elements. Features and Benefits Heavy duty construction. Installs quickly. Available in 2, 10, and 30 micron. Easy to service. See-thru collection bowl. Self-venting water drain. Selection valve. Optional accessories include: water detection kits, 12 or 24 volt dc heaters, heavy-duty fuel hose and fittings. Please Read All Instructions Prior To Beginning Installation Parker Hannifin Corporation Racor Division PO Box 3208 Modesto, CA 95354 USA Phone: 800.344.3286 Fax: 209.529.3278 E-mail: racor@parker.com Visit our website at: www.parker.com/racor

Mounting Instructions 5.0 in. (12.7 cm) 6.35 in. (16.1 cm) 6.35 in. (16.1 cm) 5.5 in. (14.0 cm) 12.7 in. (32.3 cm) Clearance for ⅜ (M10) fasteners. Notes: 1. Mount filter assembly as close to vertical (V) as possible. For best efficiency, do not exceed 10 o from vertical. 2. Do not remove valve fittings as they are integral components to the valve body. V 10 o 10 o 90 o Fuel Tanks Above Filter Do not exceed 39 feet (11.9 m) of head feet or 15 PSI. Installation Diagram Fuel Tank (Pressure Side Installation) Install a shut-off valve when fuel tank is mounted higher than the filter. Fuel Tank (Ideal Vacuum Side Installation) Inlet and outlet fuel ports on underside of selection valve. Maintain a clearance above filter assembly of at least 5 in. (12.7 cm) for servicing. Engine Install a check valve (with light or no restriction when tank is lower than filter to maintain prime. Fuel Tank (Vacuum Side Installation) Fuel Tanks Below Filter Do not exceed 5 feet (1.5 m) of lift or 4 inhg. Optional fuel transfer pump not to exceed 15 PSI (103 kpa) or maximum flow rate of the filter. NOT ideal - pumps emulsify water hindering filter performance. Maintain a clearance below filter assembly of at least 2 in. (5.1 cm) for draining and servicing bowl. Fuel transfer pump (IDEAL vacuum side installation). 2

Installation Instructions When positioning the 75500FGX: Install 75500FGX filter assemblies on the vacuum side of the fuel transfer pump for optimum water separating efficiency. See Installation Diagram. Keep fuel line restrictions to a minimum. Locate the 75500FGX assembly between the horizontal planes of the bottom of the fuel tank and the inlet of the fuel pump, if possible. If the 75500FGX assembly is installed where the fuel tank is higher than the filter, a shut-off valve must be installed between the tank and the 75500FGX INLET. This will be used when servicing the element. Before installing the 75500FGX: Obtain good ventilation and lighting. Maintain a safe working environment. The engine must be off for installation. NO smoking or open flames near installation. popular sizes, long-lasting reinforced construction, kink and cut resistance, and compatibility with a variety of standard fittings. Part Number CGH-10 CGH-12 CGH-16 Additional sizes are available. Hose I.D. 1/2 (12.5 mm) 5/8 (16 mm) 7/8 (22 mm) Additional Features High-tensile steel wire braid. No-Skive (does not require removal of outer cover to install. USCG rated for gasoline, diesel, oil and hydraulic systems. -4 o to +212 o F (-20 o to +100 o C) working temp. Installing the 75500FGX: Completely remove all vacuum side filters in fuel line between fuel tank and fuel pump. This is where the 75500FGX assembly will mount. Leaving these filters in place will increase fuel line restriction. Filter heads cast into engine or that are non-removable or hard piped should be serviced with a new element and left in place. Keep fuel flow restriction to a minimum. Always use the maximum size fuel hose possible. Do not make sharp bends with flexible fuel hose as kinks may occur. Avoid the use of two 45 o elbow fittings where one 90 o elbow will work. When routing hose, avoid surfaces that move, have sharp edges, or get hot. Racor Fuel Hose Racor fuel hose is fire resistant and meets SAE J1527 Type A class and SAE J1942 standards. This hose delivers test proven performance in a wide operating temperature range, constant working pressure in Parker/Racor Fittings All fittings below are 3/4-16 UNF (SAE J1926) O ring Boss for the 75500FGX assembly. Part Number Description Thread/Hose Size 913-O8-H6 3/8 Barbed 913-O8-H8 1/2 Elbow 913-O8-H10 5/8 911-O8-H6 3/8 Barbed 911-O8-H8 1/2 Straight 911-O8-H10 5/8 911-O8-F4 1/4 Female 911-O8-F6 3/8 NPT 911-O8-F8 1/2 913-O8-J6 9/16-18 SAE 37 913-O8-J8 o 3/4-16 Elbow 913-O8-J10 7/8-14 911-O8-J6 9/16-18 SAE 37 911-O8-J8 o 3/4-16 Straight 911-O8-J10 7/8-14 3

Priming Instructions 1. Remove both T-handles and lids from top of 75500FGX assembly. 2. Fill 75500FGX assembly with clean fuel. 3. Lubricate both lid gaskets and T-handle O-rings with clean fuel or motor oil. 4. Replace lids and T-handles and tighten snugly by hand - do not use tools. 5. If applicable, follow engine manufacturer s Service Manual to complete the fuel system priming/repriming procedure. 6. Start engine and check for leaks; correct as necessary with engine off. Service Instructions Draining Water: Frequency of water draining is determined by the contamination level of the fuel. Inspect or drain the collection bowls of water daily or as necessary. The collection bowls must be drained before contaminants reach the top of the turbine, or when the Water Detection Module (optional equipment - sold separately) indicates it s time to drain water. 1. Turn engine off and move selection valve to the ALL OFF position. Warning! Do not leave self-venting drains open too long as it could eventually drain entire filter and possibly the entire fuel system of water AND fuel. 2. With an appropriate collection pan in place, open self-venting drains on bottom of see-thru bowls and allow water and contaminants to drain from assembly. 3. Close self-venting drains at first indication of fuel. Tighten by hand only - do not use tools. 4. Follow Priming Instructions. Element Replacement: Frequency of element replacement is determined by the contamination level of the fuel. Replace the elements every 10,000 miles, every 500 hours, every other oil change, when the vacuum gauge reads between 6 to 10 inches of mercury (inhg), if power loss is noticed, or annually, whichever occurs first. Always carry extra replacement elements as one tankful of excessively dirty fuel can plug a filter. Use only genuine Racor Aquabloc II replacement elements. 1. Move selection valve to turn OFF the filter that needs to be serviced. 2. Remove T-handle and lid. 3. Remove element by holding the bail handles and slowly pulling upward with a twisting motion. Dispose properly. 4. Replace lid gasket and T-handle O-ring with new (supplied with new element). Lubricate both seals with motor oil or diesel fuel before installing. 5. Install new element. 6. Follow Priming Instructions. 4

The Selection Valve The 75500FGX allows the operator to isolate one filter at a time for servicing - even while the engine is running. The handle POINTER always indicates which unit is ON. To take one filter off-line for servicing while the engine is running, select the filter to stay on-line, then begin servicing the other. See illustration below. Warning! Handle rotates 360 o. Avoid BOTH OFF position if engine is running. BOTH ON LEFT ON / Right off Left off / RIGHT ON BOTH OFF Optional Electronic Water Detection Kits Warning! Racor electrical options are for diesel applications only. Electronic Water Detection Kits: An electronic water detection kit analyzes electrical resistance at the water sensor(s) and determines if water is present. If so, the detection module operates to indicate water, based on its specific features. All units reset automatically after water is removed (unless specified). Electronic water detection kits are available in a wide selection for various installation requirements: under dash, in-dash and remote mount. They are manufactured using the highest quality materials and are all 100% electronically tested. These kits include one water sensor and one detection module (and other components). 75500FGX users will need to purchase an additional RK21069 water sensor to complete an installation. Detailed installation instructions are included with each kit. Below are some of our more popular water detection kits; others are available. Part Number Description Voltage Under-dash mount. Light and audio. Illuminates RK12870 and sounds when water is detected. Plastic enclosure 12 vdc measures 1.4 square by 1.25 deep. Power draw is 1 milliamp. RK12871 Same as above. 24 vdc Under-dash mount. Light only. Green ON lamp illuminates with power and red DRAIN lamp lluminates when water s detected. Initial powerup self diagnosis feature 12 vdc and circuit protection ncluded. Plastic enclosure measures 2.75 by 1.0 by 1.5. Power draw is 10 milliamps. RK20725-24 Same as above. 24 vdc 5

500FG Replacement Parts Part Number Description 1. RK15378 Mounting Bracket Kit RK11838 Bracket Hardware Kit (5/16-18, not shown) 2. RK15377-01 Body Kit (3/4-16 UNF Ports) RK15377-02 Body Kit (16M X 1.5 Ports) 3. RK15035 Bowl Ring Kit 4. RK15081 Hex Head Capscrews Kit (includes 4, 10-24 x 7/8 ) 5. RK15405 See-thru Bowl Kit (includes bowl, drain, bowl gasket and probe plug) 1 RK15301 Metal Bowl Kit (not shown) (includes 1/4 NPT drain) 6. RK11-1945 T-handle and O-ring Kit (9/16-18 UNF threads) 11350 T-handle O-ring 7. RK15078 Lid and Lid Gasket Kit 15005 Lid Gasket 2 3 8. RK15397 Return Tube Kit 4 9. (Replacement elements include seals) 2010SM-OR 2 Micron Element 5 2010TM-OR 10 Micron Element 2010PM-OR 30 Micron Element 10. (Heater kits include item #11) RK15383-01 1 Heater Kit (12 vdc, 150 watt) RK15383-02 1 Heater Kit (24 vdc, 150 watt) 11. RK21067 Feed-thru Assy Kit (for heater) RK11-1679 Feed-thru Plug Kit (not shown) 12. 15374 Bowl Gasket 13. RK15010B Check Ball with Seal Kit 14. RK15013D Centrifuge/Conical Baffle Kit 15. RK20126 Water Probe Plug Kit 16. RK30880 2 Water Sensor Probe Kit Additional Parts (not shown) RK15211 Complete Seal Service Kit 6 7 8 9 10 11 12 13 14 15 16 1 In-filter heater kits require a Racor Heater Relay Kit. Maximum power requirements for in-filter heaters are: 12.5 amps for 12 volt dc and 6.3 amps for 24 volt dc. 2 Do not use on gasoline applications. Water sensors must be used with a Racor Water Detection Module. Indash, underdash and others are available. See page 5. 6

1 1 2 3 4 5 4 5 75500FGX Replacement Parts Part Number Description 1. 500FG (See 500FG Replacement Part List) 2. RK19476 Gauge Assembly Kit 3. RK15329 Main Bracket Kit 4. RK15378 Housing Bracket Kit RK11838 Housing Bracket Hardware Kit (5/16-18, not shown) 5. RK15391 Rigid Tubing and Fitting Kit 6. RK15390 Valve Assembly Kit 6 Performance Data (Controlled laboratory tests. Field results may vary.) (PSI X 2.036 = inhg) (PSI X 6.895 = kpa) 7

RACOR LIMITED WARRANTIES STATEMENT All products manufactured or distributed by Racor are subject to the following, and only the following, LIMITED EXPRESS WARRANTIES, and no others: For a period of one (1) year from and after the date of purchase of a new Racor product, Racor warrants and guarantees only to the original purchaser-user that such a product shall be free from defects of materials and workmanship in the manufacturing process. The warranty period for pumps and motors is specifically limited to ninety (90) days from the date of purchase. A product claimed to be defective must be returned to the place of purchase. Racor, at its sole option, shall replace the defective product with a comparable new product or repair the defective product. This express warranty shall be inapplicable to any product damaged or impaired by external forces. THIS IS THE EXTENT OF WARRANTIES AVAILABLE ON THIS PRODUCT. RACOR SHALL HAVE NO LIABILITY WHATSOEVER FOR CONSEQUENTIAL DAMAGES FLOWING FROM THE USE OF ANY DEFECTIVE PRODUCT OR BY REASON OF THE FAILURE OF ANY PRODUCT. RACOR SPECIFICALLY DISAVOWS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED INCLUDING, WITHOUT LIMITATION, ALL WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE (EXCEPT FOR THOSE WHICH APPLY TO PRODUCT OR PART THEREOF THAT IS USED OR BOUGHT FOR USE PRIMARILY FOR PERSONAL, FAMILY, OR HOUSEHOLD PURPOSES), WARRANTIES OF DESCRIPTION, WARRANTIES OF MERCHANTABILITY, TRADE USE OR WARRANTIES OR TRADE USAGE. WARNING Failure or improper selection or improper use of the products and/or systems described herein or related items can cause death, personal injury and property damage. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including with limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. The following statement is required pursuant to proposition 65, applicable to the State of California: This product may contain a chemical known to the State of California to cause cancer and reproductive toxicity. Racor s policy is one of continual improvement in design and manufacturing to insure still finer products; therefore, specifications, equipment and product information, while correct at the time of publication, is subject to change without notice. Copyright, Parker Hannifin Corporation, August 2004. Part number 13011 Revision -.