KESSEL-Grease Separator Under sink

Similar documents
KESSEL-Staufix double flap lockable backwater valve KESSEL-Staufix single flap lockable backwater valve KESSEL- Staufix single flap backwater valve

INSTRUCTION MANUAL. Stephenson Road Speedwell Industrial Estate Staveley Chesterfield S43 3JN

SUBJECT: THIS IS THE ANNUAL GREASE DAMAGE PREVENTION PERMIT.

Installation and Operating Procedures

OSCAR- LOWeFLOW Treatment System Homeowner s Manual. January 2016

Separators. The new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation

SEPTIC TANKS. Round septic tanks. Standard version ECO version. Rectangular septic tanks. ECO version

FOG Hog Grease Interceptor System Installation & Service Manual FOR USE WITH FOGHog FH-20, FH0-35, FH-50, FH-75, and FH-100

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual

Separators. The new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation

SUBMERSIBLE DIRTY WATER PUMP

CHATSWORTH WATER WORKS COMMISSION GREASE AND OIL CONTROL ORDINANCE

Salesfolder Light fluid and EN grease separator Light fluid and grease separator

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING

Excerpt from Chapter 3 of the City Code that address Fats, Oils and Grease (FOG) control program that was adopted by the City Council on May 9, 2016.

Grease Inspection Program

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual

Florida Community Services Corporation of Walton County d/b/a Regional Utilities (Regional) FOG Control Policy

Installation and Maintenance Manual CORRUGATED RIVETED GALVANIZED STEEL WATER STORAGE TANKS

BECKLEY. General: Page 1

Gullies. Box - Gutters. Slot - Gutters. Grease Locks

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

HYDROCARBON SEPARATORS

Installation, Operation & Maintenance Manual. TotlSep (TS) Series. FRP Oil/Water Separator

1BGrease Traps and. Frequently Asked Questions About Grease:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

SASKATCHEWAN AMENDMENTS TO APPENDICES OF THE NATIONAL PLUMBING CODE, 2005

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

original operating manual Operating manual Translation of the Item-No.: ,

Installation & Operation Instructions For EZ Klear Systems Model EZK-25

OWNER S MANUAL GREAT BASIN GREASE INTERCEPTORS

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

FPU SYSTEMS OPERATION MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH CONTAINERIZED LATRINES BOH FPU Field Pack-up Units

OPERATION MANUAL BATTERY CHARGER DFC-10P DFC-50P DFC-450P DFC-650P

Fuel and Oil Separators

FORT RUCKER Environmental Management System

Hydraulic Immediate Need Power Pack

Hydraulic PTO Flow Device

Operating Manual Includes Pumps: PG-9000 Part #R809606

(a) Administrator means Clearwater's Public Works Administrator or his or her designee.

MODEL RF. Drain Cleaning Machine. Operator s Manual

2 TONNE TROLLEY JACK

A2P Single Phase Automatic Industrial Battery Charger

Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service

WSB clean: Installation Manual

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service

ST. TAMMANY PARISH COUNCIL ORDINANCE

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Artisan Professional Mixer

OWNER S MANUAL PORTABLE POWER COMPACT & ROBUST

SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638

Vertico Sink Mixer. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

INSTALLATION AND OPERATING INSTRUCTIONS FOR FLOODED TUBULAR-HP MOTIVE POWER BATTERIES

Reliable backwater protection. Protection from backwater. Backwater protection for interior installation

Parker Hannifin Filtration Group Racor Division DUAL FBO OPERATION AND MAINTENANCE INSTRUCTIONS SPARE PARTS

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

Installation manual portable distributors

04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459,

Instruction Manual. Sewage lifting station compli 300

Daikin Steam Coils. Installation and Maintenance Manual IM 901. Types HI-F5, HI-F8, & E-F5. Group: Applied Air. Part Number: IM 901

Fats, Oils & Grease Ordinance and Program. Presented by Lance McAvoy Deputy Director of Operations

HWP2/HWP3/HWP4 Hydraulic Submersible Pumps

Commercial Fats, Oils & Grease Stephen Sealey

Hampton Roads Planning District Commission

City of Tega Cay, South Carolina

NEOGARD. Preventive Maintenance Manual

ORDINANCE NO BE ORDAINED BY THE CITY COUNCIL OF THE CITY OF TALLADEGA, ALABAMA, AS FOLLOWS:

1600 PSI ELECTRIC PRESSURE WASHER

SELF PRIMING CHEMICAL SERVICE PUMPS

HH10/HH10RV Hydraulic Breaker

HCS14/16/18 Hydraulic Cut-off Saw. Prior to Operation. We thank you for choosing a HYCON cut-off saw.

Chip Vacuum Removal System INSTRUCTION MANUAL

ABCD BFDC BEDA AB CDEFCC

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

INSTALLATION AND OPERATING INSTRUCTIONS FOR FLOODED TUBULAR-HP AND TUBULAR-LM FAST CHARGE MOTIVE POWER BATTERIES

HST-BL-2830MS & HST-BL-2830MS-USA

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

ClariMax Inclined Plate Clarifier. Installation, Operation & Maintenance Manual

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions

80 Litre Suction Oil Drainer With Inspection Chamber

Model : LMHS-60 Please read this manual carefully before using the instrument Labnics Equipment

HWP2/HWP3/HWP4 Hydraulic Submersible Pumps

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

OPERATION & MAINTENANCE INSTRUCTIONS

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

When is Septage Really Septage? GLAD TO SEE YOU MADE THE MOVE!

Installation manual wall-mounted distributor

Inst all a ti o n and Oper a tin g Instru c ti o n s

Instructions for use. Hawker Premier

Specifications. Important Safety Information

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

Fats, Rags, Oils, and Grease Program. Bedford Regional Water Authority

OPERATION & MAINTENANCE INSTRUCTIONS

Translation of the Original operating instructions Lifting device Z 70 /...

Regulation of Commercial Waste Originators, Pumpers, Transporters, Processors, and Disposal Facilities

GREASE INTERCEPTOR REQUIREMENTS Lakeway Municipal Utility District

Cone Skimmers. Instructions. for Models 75G, 150G and 300G. Please read these instructions in their entirety before attempting to use this product.

EQUIPMENT OWNERS MANUAL MATTHIESEN HEAVY DUTY SHAKER

Transcription:

INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE KESSEL-Grease Separator Under sink Order Number 93025.00/US Product advantages Compact structure fully adjustable inlet 290 to 420 260 350 release odor tight cover Dimensions in mm Installation Operation Instruction for the system was carried out by your specialist company: Name/Signature Date City Stamp of specialist company Edition: 09/2010 ID number: 010-848 Subject to technical modifications

Safety Instructions By installation, use, maintenance and repair of this unit please follow all safety precautions and accident prevention guidelines. Also please follow any local safety precautions and accident prevention guidelines established in your area. NO SMOKING! Smoking must not be permitted near the separator during use, maintenance and repair of the unit due to the potential build up of methane / biogas. SLIPPERY WHEN WET! Take caution when standing / walking near the separator. During disposal, cleaning and maintenance the surrounding area can become extremely slippery due to spilled water / grease / fat. SEPARATOR AREA REGULATIONS: No access of the separator for unauthorized personnel The location of the separator should be chosen carefully as to allow sufficient access for maintenance, inspection, repair and disposal of the separator. The wastewater in a grease separator can contain bacteria. After coming in contact with wastewater, it is important to wash, clean and disinfect all skin which has been contaminated. 2

Table of contents Safety Instructions... Page 2 1. General Use... Page 4 Commissioning... Page 4 2. Maintenance... Page 5 3. Warranty... Page 6 CE-Declaration of confromity... Page 7 Dear Customer, Before the KESSEL Under Sink Separator is installed and placed in operation please carefully read and follow all of the instructions contained in this Installation, Maintenance and Safety Instructions. Upon delivery of the Under Sink Separator please thoroughly inspect the separator to make sure that it has not been damaged during shipping. In case damage has occurred to the separator, please follow the instructions listed in the Guarantee section of this Manual. 3

1. General Use Animal and vegetable oils and fats must not be discharged into public disposal systems and into bodies of water, since they can cause narrowing of cross-sections and blockages in the disposal pipes when they set. In addition, fatty acids are produced after a short decomposing time, leading to unpleasant odours and corroding pipes and constructional elements of the draining systems. The solidified grease layer on the surface of the water also hinders the necessary oxygen supply to bodies of water and sewage treatment plants. Commissioning Place separator into position and connect inlet and outlet pipes. Remove any debris from the separator and clean (including inlet and outlet). Completely fill separator (to outlet level) with cold water. Check exterior of separator to insure water tightness. Please note that the unit is designed to receive kitchen wastewater with a maximum temperature of 60 degrees Celsius (140 degrees F). Temperatures higher than 60 degrees Celsius could damage the unit. Ø 50 Dimensioned drawing Nominal size 0,25 Ø 50 426 790 to 930 Ø 50 296 Dimensions in mm storage volumes sludge trap Grease trap 7 l 7 l 4

2. Maintenance The chapter "Safety instructions" must be heeded! Disposal Under sink separators require daily grease removal. This grease separator is to be completely emptied and cleaned on a weekly basis. Notice: proper maintenance and disposal is required for correct grease separator operation.. Servicing The separator system must be serviced once a year by a qualified person Alongside disposal measures, the following jobs must be carried out: - Check on the inner walls of the sludge trap and the grease separator - Records of the findings and work carried out must be kept in the operating log and evaluated. Review (general inspection) Before initial operation and then at regular intervals of not longer than 5 years, the separator system must be checked for proper condition and correct operation by a technical expert following complete emptying and cleaning. At least the following points must be checked and recorded: - Condition of the inner walls of the built-in components if appropriate - Completeness and plausibility of records in the operating log - Proof of correct disposal of the contents of the separator system removed A test report must be drawn up for the inspection carried out, listing any faults found. If faults are found, they have to be eliminated without delay. 5

3. Warranty 1. In the case that a KESSEL product is defective, KESSEL has the option of repairing or replacing the product. If the product remains defective after the second attempt to repair or replace the product or it is economically unfeasible to repair or replace the product, the customer has the right to cancel the order / contract or reduce payment accordingly. KESSEL must be notified immediately in writing of defects in a product. In the case that the defect is not visible or difficult to detect, KESSEL must be notified immediately in writing of the defect as soon as it is discovered. If the product is repaired or replaced, the newly repaired or replaced product shall receive a new warranty identical to that which the original (defective) product was granted. The term defective product refers only to the product or part needing repair or replacement and not necessarily to the entire product or unit. KESSEL products are warranted for a period of 24 month. This warranty period begins on the day the product is shipped form KES- SEL to its customer. The warranty only applies to newly manufactured products. Additional information can be found in section 377 of the HGB. This additional warranty applies to the watertightness, usability and structural soundness of the product. A requirement of this additional warranty is that the product is properly installed and operated in accordance with the valid installation and user's manual as well as the corresponding norms / regulations. 2. Wear and tear on a product will not be considered a defect. Problems with products resulting from improper installation, handling or maintenance will also be considered a defect. Note: Only the manufacturer may open sealed components or screw connections. Otherwise, the warranty may become null and void 01.06.2010 6

5. CE Declaration of conformity 7

Backwater protection Lifting Stations and pumps Drains and shower channels Separators -Grease Separators -Oil-/Fuel-/Coalescence Separators -Starch Separators -SedimentSeparators Septic Systems Inspection Chambers Rainwater Management Systems