MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

Similar documents
STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

Mission Critical Standby 1400 ekw 1750 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

DIESEL GENERATOR SET FEATURES

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 225 ekw 281 kva

ESP 550 ekw 688 kva 60 Hz 1800 rpm 480 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

DIESEL FEATURES GENERATOR SET

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

Voltage 220 to or 1800 RPM

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

Specifications. 3406C Generator Set Electric Power

3412C Generator Set Electric Power. Specifications. Benefits and Features

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

220 to volts. Electronic unit injection

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm 480 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

Continuous, Prime, Standby, Mission Critical

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1600 ekw 2000 kva 50 Hz 1500 rpm Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 200 ekw 250 kva

Mission STANDBY Critical Standby 2000 ekw 2500 kva 60 Hz 1800 rpm 480 Volts

STANDBY 200 ekw 250 kva

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

Caterpillar 2500 kw 3516C

Generator Set Specifications 100 ekw (125 kva)

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

CONTINUOUS 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

Mission Critical Standby 1800 ekw 2250 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 292 ekw 365 kva 50 Hz 1500 rpm 400 Volts

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

STANDBY 350 ekw kva 60 Hz 1800 rpm 480 Volts

STANDBY 350 ekw 438 kva 60 Hz 1800 rpm 480 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

Prime 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

STANDBY 440 ekw 550 kva 50 Hz 1500 rpm 400 Volts

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 480 Volts

PRIME 480 ekw 600 kva 50 Hz 1500 rpm 400 Volts

Generator Set Specifications 60 ekw (75 kva)

C13. STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

400 to 11,000 Volts. Standby, Prime, Continuous

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

Transcription:

DIESEL GENERATOR SET MISSION CRITICAL STANDBY 1100 ekw 1375 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. FEATURES Image shown may not reflect actual package. FUEL/EMISSIONS STRATEGY Low Fuel consumption DESIGN CRITERIA The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response FULL RANGE OF ATTACHMENTS Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost effective installation UL 2200 / CSA - Optional UL 2200 listed packages CSA Certified Certain restrictions may apply. Consult with your Cat Dealer. WORLDWIDE PRODUCT SUPPORT Cat dealers provide extensive post sale support including maintenance and repair agreements Cat dealers have over 1,800 dealer branch stores operating in 200 countries The Cat S O SSM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products CAT 3512 TA DIESEL ENGINE Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight CAT GENERATOR Matched to the performance and output characteristics of Cat engines Industry leading mechanical and electrical design Industry leading motor starting capabilities High Efficiency CAT EMCP 4 CONTROL PANELS Simple user friendly interface and navigation Scalable system to meet a wide range of customer needs Integrated Control System and Communications Gateway

FACTORY INSTALLED STANDARD &OPTIONAL EQUIPMENT System Standard Optional Air Inlet Air cleaner Cooling Package mounted radiator Exhaust Exhaust flange outlet []Exhaust mufflers (except Tier 4) Fuel Generator Primary fuel filter with integral water separator Secondary fuel filters Fuel priming pump Matched to the performance and output characteristics of Cat engines Load adjustment module provides engine relief upon load impact and improves laod acceptance and recovery time IP23 protection []Oversize and premium generators []Permanent magnet excitation (PMG) []Internal excited (IE) []Anti-condensation space heaters Power Termination Bus bar [] Circuit breakers, UL listed [] Circuit breakers, IEC compliant Control Panel EMCP 4Genset Controller []EMCP 4.2 []EMCP 4.3 []EMCP 4.4 []Generator temperature monitoring and protection []Load share module []Digital I/O module []Remote monitoring software Mounting []Rubber vibration isolators Starting/Charging General Paint -Caterpillar Yellow except rails and radiators gloss black []Battery chargers []Oversize batteries []Jacket water heater []Heavy duty starting system []Charging alternator []Air starting motor with control and silencer (3500 & C175 models only) The following options are based on regional and product configuration: []Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007 []EU Certificate of Conformance (CE) []UL 2200 package []CSA Certification []EEC Declaration of Conformity [] Enclosures- sound attenuated, weather protective []Automatic transfer switches (ATS) []Integral &sub-base fuel tanks []Integral &sub-base UL listed dual wall fuel tanks 2

SPECIFICATIONS CAT GENERATOR Cat Generator Frame size... 1402 Excitation...Internal Excitation Pitch... 0.6667 Number of poles...4 Number of bearings... Single bearing Number of Leads... 006 Insulation... UL 1446 Recognized Class H with tropicalization and antiabrasion - Consult your Caterpillar dealer for available voltages IP Rating... IP23 Alignment... Pilot Shaft Overspeed capability...125 Wave form Deviation (Line to Line)... 002.00 Voltage regulator... 3 Phase sensing with selectible volts/hz Voltage regulation...less than +/- 1/2% (steady state) Less than +/- 1% (no load to full load) CAT DIESEL ENGINE 3512 TA, V-12, 4-Stroke Water-cooled Diesel Bore... 170.00 mm (6.69 in) Stroke... 190.00 mm (7.48 in) Displacement...51.80 L (3161.03 in 3 ) Compression Ratio... 13.5:1 Aspiration... TA Fuel System... Direct unit injection Governor Type... Woodward CAT EMCP 4 SERIES CONTROLS EMCP 4 controls including: - Run / Auto / Stop Control - Speed and Voltage Adjust - Engine Cycle Crank - 24-volt DC operation - Environmental sealed front face - Text alarm/event descriptions Digital indication for: - RPM - DC volts - Operating hours - Oil pressure (psi, kpa or bar) - Coolant temperature - Volts (L-L & L-N), frequency (Hz) - Amps (per phase & average) - ekw, kva, kvar, kw-hr, %kw, PF Warning/shutdown with common LED indication of: - Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level Programmable protective relaying functions: - Generator phase sequence - Over/Under voltage (27/59) - Over/Under Frequency (81 o/u) - Reverse Power (kw) (32) - Reverse reactive power (kvar) (32RV) - Overcurrent (50/51) Communications: - Six digital inputs (4.2 only) - Four relay outputs (Form A) - Two relay outputs (Form C) - Two digital outputs - Customer data link (Modbus RTU) - Accessory module data link - Serial annunciator module data link - Emergency stop pushbutton Compatible with the following: - Digital I/O module - Local Annunciator - Remote CAN annunciator - Remote serial annunciator 3

TECHNICAL DATA Open Generator Set - - 1800 rpm/60 Hz/480 Volts Low Fuel Consumption DM8224 Generator Set Package Performance Genset Power rating @0.8 pf Genset Power rating with fan Fuel Consumption 100% load with fan 75% load with fan 50% load with fan Cooling System 1 Air flow restriction (system) Air flow (max @rated speed for radiator arrangement) Engine Coolant capacity with radiator/exp. tank Engine coolant capacity Radiator coolant capacity 1375 kva 1100 ekw 305.4 L/hr 80.7 Gal/hr 232.6 L/hr 61.4 Gal/hr 167.0 L/hr 44.1 Gal/hr 0.12 kpa 0.48 in. water 1331 m³/min 47004 cfm 286.8 L 75.8 gal 156.8 L 41.4 gal 130.0 L 34.3 gal Inlet Air Combustion air inlet flow rate 92.3 m³/min 3259.5 cfm Exhaust System Exhaust stack gas temperature Exhaust gas flow rate Exhaust flange size (internal diameter) Exhaust system backpressure (maximum allowable) Heat Rejection Heat rejection to coolant (total) Heat rejection to exhaust (total) Heat rejection to aftercooler Heat rejection to atmosphere from engine Heat rejection to atmosphere from generator Alternator 2 Motor starting capability @ 30% voltage dip Frame Temperature Rise 524.0 º C 975.2 º F 258.9 m³/min 9143.0 cfm 203.2 mm 8.0 in 6.7 kpa 26.9 in. water 729 kw 41458 Btu/min 1202 kw 68358 Btu/min 134 kw 7621 Btu/min 122 kw 6938 Btu/min 62.8 kw 3571.4 Btu/min 2734 skva 1402 150 º C 270 º F Lube System Sump refill with filter 310.4 L 82.0 gal Emissions (Nominal) 3 NOx g/hp-hr CO g/hp-hr HC g/hp-hr PM g/hp-hr 8.92 g/hp-hr 1.3 g/hp-hr.16 g/hp-hr.236 g/hp-hr 1 For ambient and altitude capabilities consult your Cat dealer. Air flow restriction (system) is added to existing restriction from factory. 2 UL 2200 Listed packages may have oversized generators with adifferent temperature rise and motor starting characteristics. Generator temperature rise is based on a40ºc ambient per NEMA MG1-32. 3 Emissions data measurement procedures are consistent with those described in EPA CFR 40 Part 89, Subpart D &Eand ISO8178-1 for measuring HC, CO, PM, NOx. Data shown is based on steady state operating conditions of 77ºF, 28.42 in HG and number 2 diesel fuel with 35º API and LHV of 18,390 btu/lb. The nominal emissions data shown is subject to instrumentation, measurement, facility and engine to engine variations. Emissions data is based on 100% load and thus cannot be used to compare to EPA regulations which use values based on aweighted cycle. 4

RATING DEFINITIONS AND CONDITIONS Applicable Codes and Standards: AS1359, CSA C22.2 No 100-04, UL142, UL489, UL601, UL869, UL2200, NFPA 37, NFPA 70, NFPA 99, NFPA 110, IBC, IEC60034-1, ISO3046, ISO8528, NEMA MG 1-22, NEMA MG 1-33, 72/23/EEC, 98/37/EC, 2004/108/EC Mission Critical Standby Output available with varying load for the duration of the interruption of the normal source power. Average power output is 85% of the standby power rating. Typical peak demand up to 100% of standby rated ekw for 5% of the operating time. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year. Fuel stop power in accordance with ISO3046. Standby ambients shown indicate ambient temperature at 100% load which results in a coolant top tank temperature just just below the shutdown temperature. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions. Fuel Rates are based on fuel oil of 35º API (16º Cor 60º F) gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C(85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional Ratings may be available for specific customer requirements. Consult your Cat representative for details. 5

DIMENSIONS Length Width Height Package Dimensions Information not available at this time. NOTE: For reference only - do not use for installation design. Please contact your local dealer for exact weight and dimensions. www.cat-electricpower.com Feature Code: 512DE7D Gen. Arr. Number: 2523756 Source: U.S. Sourced 2013 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, "Caterpillar Yellow," the "Power Edge" trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. 6