Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

Similar documents
Installation Instructions CRAFT M/L

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

MOONRING 1.5 MOONRING 3

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

I. Pendant Mount Installation

LED VaporProof Fixture

Captivate Illuminated Mirror Light

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION

LED VAPOR PROOF FIXTURE

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

INSTALLATION INSTRUCTION Magnetic Transformer

Elle Surface Mounting Instructions

INSTALLATION INSTRUCTIONS

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Specification Grade Contemporary Wall Mount/Technical Installation Data

Elle Surface Mounting Instructions

INSTALLATION INSTRUCTION Bollard Light 12V

HP-2 / HP-6 Direct Installation Instructions Overview

Luminaire Support Location Cable Mounting Kit. Non-Power Feed

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

When using electrical equipment, basic safety precautions should always be followed including the following:

INSTALLATION INSTRUCTIONS

Wet Rated Batten LED Luminaire

RSA-MRZ Installation Instructions

REGOLO 1. RP11 Direct

General Installation Instructions LED

RSA-MRZ Installation Instructions

MAXLITE RKT LED Retrofit Kit

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

LED Direct-Lit Panels

Installation Instructions Shaper 1800 aircraft cable installation

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

960 Montage sur staff préfabriqué Mounting in prefabricated plaster

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

Installation Instruction

MODELS 2 & 4 Top Conduit Linears

INSTALLATION INSTRUCTION Accent - Color Changing

Lumination TM LED Luminaire (IS Series)

MODELS. 2 & 4 Low Profile Linears

WARNING / AVERTISSEMENT

Basis Hardware. Translite Low Voltage Track System

Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento.

HBDBM High Bay Series

LAL SERIES LED LUMINAIRE

LED Recessed Troffer Retrofit Kit

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

Remote Operator Accionamiento a distancia Commande motorisée

Luminaire PROFILE-SPOKE 15 UP 85 DN LED (PS1-D) Type. Notes. Performance Summary D OPTIONS 3S A 28 W B 34 W C 44 W D 57 W

GEMINI HOUSING SPECIFICATIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

RECESSED TRACK (120V) SPECIFICATIONS

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

Maximum Weight Capacity: Top Glass Shelf: 110 lbs. MODEL E113E ASSEMBLY INSTRUCTIONS. Important! Read all warnings before starting assembly.

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

Jump Starter and AC/DC/USB Power Source Arrancador y CA / CC / USB fuente de alimentación

1Unpack fixture. Suspensions/canopies are ordered and

The lever must be placed at the lower position, when the track head is intended to be use in a one-circuit track system.

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

N100C N100C COIL-FED PNEUMATIC NAILERS CLAVADORAS NEUMÁTICAS ALIMENTADAS POR ROLLO CLOUEURS PNEUMATIQUES À ENROULEMENT

INSTALLATION DATA ETC SINGLE Stage

classic white Refined minimalism

General Installation Instructions LED

INSTALLATION GUIDE Works in double and single ended wiring.

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

Inde-Pendants Family. 32L Cylinder with Ring Chicago Plenum Ceiling Types. Document No

PRODUCT DESCRIPTION SPECIFICATIONS

Cable Cubby 1202 and 1402 Installation Guide

LIGHTPLANE 1 RECESSED - LP1R

MOUNTING SYSTEMS SPECIFICATIONS

Horticulture Batten LED Luminaire

Luminaire PROFILE-SPOKE Ind. Up Dn Control (PS3-B) Type. Project. Notes. Performance Summary OPTIONS 4S D 76 W 3S D 57 W

Universal Retrofit System Installation Instructions Revised:

Spun Bay Installation Standard Version (non dimmable), Hook Mount

NT-300 Series Single Circuit Track System & Accessories

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

LumeLEX 2084 SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

INSTALLATION DATA ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Installation Instructions - Continua Suspended LED

Round or Square Chicago Plenum Hi-lume Wall Wash Housing with LED Lamp for Flanged Trims E3_F_-L_WC-HL 1.0

INSTALLATION DATA ETC SINGLE STAGE ELECTRONIC TEMPERATURE CONTROL

Installation Instructions

MODELS SafeSite LED Linear, Class I Div V, 2 & 4 Versions

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

Customer service: or Upper mounting ring. Canopy

Transcription:

WARNINGS: Do not assemble continuous run on the ground and lift into place. Joints will distort and not create a tight fit. Joining hardware will have to be purchased and replaced. Risk of electrical shock or fire, disconnect power during installation or servicing. Read all instructions completely before starting installation. Install and wire in accordance to all national and local codes by a certifi ed electrician. Fixture may be sharp, handle with care. Let fixture cool before maintenance. AVERTISSEMENTS Risque d électrocution ou d incendie. Déconnectez l alimentation durant l installation ou la maintenance. Lisez attentivement toutes les instructions avant de commencer toute installation. Faites installer et câbler selon les normes Nationales et Locales par un électricien certifi é. Les installations peuvent être coupantes, à manipuler avec précaution. Laissez refroidir les installations avant une opération de maintenance. ADVERTENCIA Riesgo de descarga eléctrica oun incendio, desconecte la alimentación durante la instalación o servicio. Leer todas las instrucciones completas antes de empesar la instalación. Instalar y cablear en acuerdo a las reglas nacionales y códigos locales por un electricista certifi cado. El accesorio puede estar agudo, agarre con cuidado deje que el acessorio. Enfriar antes de mantenimiento. DISTORT JOINT Page 1

lighting system components ***Every luminaire will have a companion driver enclosure, not all luminaires and driver enclosures are the same, please be sure to pair the proper driver enclosure to the proper luminaire by reading the packaging labels*** 1. LUMINAIRE Package Contents Luminaire Includes factory installed 4 conductor low voltage power cord (48 Aircraft Cable = 78 Power Cord 120 Aircraft Cable = 150 Power Cord) Includes factory installed aircraft cable adjuster(s) 1. CANOPY/ DRIVER ENCLOSURE Package Contents Driver enclosure with bar hanger flange, remove for retrofit applications Power Canopy Hardware Packet (1) 5 diameter canopy (1) Stainless Steel aircraft cable coupler (1) 48 Plenum Rated Cord Sleeve (1) 48 or 120 Aircraft Cable (1) 8.25 Threaded Stem 1/4-20 (For Retrofit Only) (1) 8.75 Threaded Stem 1/4-20 (New Con struction 5/8 Sheet Rock) (1) 9.5 Threaded Stem 1/4-20 (for 1 1/4 sheet rock) 3. NON-POWER MOUNT HANGING HARDWARE NON POWER HARDWARE Package Contents Notes: Non-Power canopy hardware is only necessary for individual and row starter luminaires Non-Power Canopy Hardware Packet (1) 3 diameter canopy (1) Stainless Steel aircraft cable coupler (1) 48 or 120 aircraft cable Page 2

luminaire dimensions SERO 26 1/4 (667mm) 50 1/4 (1276mm) 2 1/4 74 1/4 (1886mm) 98 1/4 (2496mm) 4 1/4 QuB 26 1/4 (667mm) 50 1/4 (1276mm) 2 1/4 74 1/4 (1886mm) 98 1/4 (2496mm) 4 1/4 driver enclosure dimensions 6.74 4.54 7.44 6.35 8.09 4.35 2.5 3.51 5.39 6.74 6.35 Page 3

installing an individual or row starter luminaire step 1 5 Dia. 2 Line Voltage Low voltage dimming Cut 5 Diameter hole into sheet rock and pull wires though hole Remove and discard hanger bar flange after removing 3 screws 3 4 Purple (Dim) Dimming Circuit White (Neutral) Green (Ground) Black (Hot) Grey (Dim) White (Neutral) Green (Ground) Black (Hot) Remove top access cover and make low dimming wire connections if necessary Make line voltage wire connections Page 4

installing an individual or row starter luminaire 5 6 re-attach splice cover Insert driver enclosure into ceiling 7 8 Recycle Recycle Rotate two philips screws clock wise to secure brackets to sheet rock Install the smallest threaded rod into center of driver enclosure 9 10 Thread cord, coupler and aircraft cable into canopy as shown Connect coupler and aircraft cable to threaded stem Page 5

installing an individual or rowstarter luminaire 11 12 Red Release Pin Blue Red w/ white stripe Blue w/ white stripe Remove driver cartridge by pushing release pin, and make low voltage wire connection, then push driver assembly back into enclosure and attach 5 canopy as shown On power side thread aircraft cable though adjuster on luminaire (level and trim cable as last step) 14 13 Screw threaded coupler and non-power canopy onto mounting stem to physically hang luminaire On non-power side thread aircraft cable though adjuster on luminaire (level and trim cable as last step) Page 6 NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com

installing a row-mid or row-end (after starter has been installed, step 2 or step 3) step 1 step 2 step 3 ***2 cable mounts in first fixture, only one cable mount in each subsequent fixture*** 1-12 Repeat Steps 1-12 on page 4-6 to install next Grid driver enclosure in the row 13 Captive Spring Latch joins fixtures Row Mid or Row End After the Row Mid or Row End has been suspended at the far end, connect the luminaire to the Row Starter by sliding the luminaires together and then using the spring latch to securely make the final connection. Row Starter Page 7