DIN Track Terminal Blocks with Screw Terminals XW5T

Similar documents
DIN Track Terminal Blocks with Screw Terminals

DIN Track Terminal Blocks with Screw Terminals XW5T

S8JX-N/S8JX-G Series Replacement Brackets

Better Productivity by Standstill and Low-speed Monitoring

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

G3PE-Single-phase. Solid State Relays for Heaters

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

D4BS CSM_D4BS_DS_E_8_4

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

D4GS-N CSM_D4GS-N_DS_E_7_2

Model Number Structure

Redundancy Unit. Model Number Structure. Ordering Information. Model Number Legend. New Product. S8VK-R Series name

A165E CSM_A165E_DS_E_11_2

2NC (slow-action) Direct. Model. opening

Dimension A. Dimension B

A22LK CSM_A22LK_DS_E_6_2

D4BL. Guard Lock Safety-door Switch

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

Pushbutton Switches 30-mm Pushbutton Switches Universal Design. Emphasis on Color Coding, Workability, and Safety.

D4NH CSM_D4NH_DS_E_7_1

2NC (slow-action) Direct. Model. opening

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

Quick Installation Manual

High-power Solid State Relays G3PH

M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models

Small-diameter Proximity Sensor

A22E. Emergency Stop Switch (22-dia./25-dia.) Install in 22-dia. or 25-dia. Panel Cutout. Model Number Structure L M 24A 01

Digital display Pressure range ON/OFF output Linear output Model

CSM_D4N-_R_DS_E_6_1

Solid State Relays for Heaters

High-power Solid State Relays G3PH

Solid State Relays for Heaters

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Multiple Limit Switch

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

D4NS/D4NS-SK. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Nextgeneration. Model Number Structure. Model Number Legend

A4EG CSM_A4EG_DS_E_6_1

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

Digital Temperature Controllers/ NX-series Temperature Control Unit

A22TK Key-type Selector Switch with Direct Opening Mechanism

Power ratings Input voltage Output Voltage Output current Boost Current Model number 120 W 2-phase and 3-phase

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

Switch Mode Power Supply S8JC-Z / S8JC-ZS / S8JX-G / S8JX-P / S8VK-G / S8VK-C. Power Supply Selection Guide

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4.

Smile 41 Push-button box with/without emergency stop

Tina 4A Connection block

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

Smile 11 RA/-B Smile 12 RF/-G Reset button

A3S. Pushbutton Switch Series with Square 40-mm Body. Lighted Pushbutton Switch (Square) List of Models

Safety Limit Switch

EStrong-series Emergency Stop

1,000 M min. (at 500 VDC)

Tina 11A Connection block

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

Power ratings Input voltage Output Voltage Output current Boost Current Model number 120 W 2-phase and 3-phase

Sense7-series Non-contact coded safety switch

D4BL. Guard Lock Safety-door Switch

LED Signal Towers. Pre-assembled and pre-cabled in different aperture to highlight the processes. Features/Unique selling proposition

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Safety Guard Switching Unit G9SX-GS

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Clicks for Three Easily Discernable Positions

PRODUCT SPECIFICATION. Foot Switches. Series.

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions. Ordering Information

FMC-1/2 Tina Muting unit

Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai Ph: Mob: Fax:

Tina 10A/B/C Adaptor unit

! Refer to Safety Precautions on page A/120 W S8BA-24D24D120LF 10 A/240 W S8BA-24D24D240LF 15 A/360 W S8BA-24D24D360LF

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

MKey9-series Safety Interlock Switch with Guard Locking

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

D4NL CSM_D4NL_DS_E_9_2

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

A22TK Key-type Selector Switch with Direct Opening Mechanism

20250 Module Installation Guide

A22E. Model Number Structure. Emergency Stop Switch. Model Number Legend. Completely Assembled. Install in 22-dia. or 25-dia.

! Refer to Safety Precautions on page A/120 W S8BA-24D24D120LF 10 A/240 W S8BA-24D24D240LF 15 A/360 W S8BA-24D24D360LF

Solid State Relays G3NA. Model Number Structure. Model Number Legend

Female Plug. connecting to Fuel Quantity

GM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com

30100 Module Installation Guide L

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

PRODUCT SPECIFICATION. Stack Lights. Series.

Power Supply. Model PS-200

Guardian FBA Flywheel Coupling

G3NA. Model Number Structure. Solid State Relays. Model Number Legend

DIN Track Terminal Blocks

JD2800 Module Installation Guide

TONS. Before each shift: Before operating: Before initial operation of hoist:

15100 Module Installation Guide Mercedes EPA07 w/dpf

GRADE 3 TUBULAR LOCKSETS INDEX:

Installation Guide. Marine Filter SURT023M SURT024M

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be

Model Number Structure. Characteristics. Model Number Legend. Soft Starter. Applicable Motors. Accessories

Cummins N14 Celect & Celect Plus Engine Module. For Agricultural Applications Only. Part # 31200

CU6703 Module Installation Guide

Transcription:

New Product DIN Track Terminal Blocks with Screw Terminals XW5T Global-standard DIN Terminal Blocks for Control Panels Wires held with screws. Compatible with a wide range of wire sizes with a nominal cross section from 2.5 to 150 mm 2. Terminal Blocks with Fuses and Disconnect Terminal Blocks are available. Refer to Safety Precautions on page 20. Refer to your OMRON website for the most recent information on models that are certified for standards. Model Number Legend Feed Through Terminal Blocks XW5T - S@-@-@@ (1) Nominal Cross Section 2.5: 2.5mm 2 4.0: 4.0mm 2.0:.0mm 2 10: 10mm 2 1: 1mm 2 35: 35mm 2 70: 70mm 2 150: 150mm 2 Grounding Terminal Blocks XW5G - S@-@-@ (1) (2) (3) (4) (1) (2) (3) (2) Wiring 1.1:1:1 1.2:1:2 2.2:2:2 (3) Number of Tiers 1: 1 tier 2: 2 tiers (4) Color Blank: Dark gray BL: Blue V: Black (Vertical Connection) 1

Ordering Information Classification Feed Through Terminal blocks Grounding Terminal blocks Special terminals Product Type Standard terminals Multi tiers terminal Multi conductor terminals Nominal Cross Section (mm 2 ) Number of levels Number of cramp position per level Coler Insulating material Flammability Rating according to UL94 Model Pack Weight (pcs.) (gram) 2.5 1 2 Dark gray PA V0 XW5T-S2.5-1.1-1 100 8 2.5 1 2 Blue PA V0 XW5T-S2.5-1.1-1BL 100 8 4.0 1 2 Dark gray PA V0 XW5T-S4.0-1.1-1 100 9 4.0 1 2 Blue PA V0 XW5T-S4.0-1.1-1BL 100 9.0 1 2 Dark gray PA V0 XW5T-S.0-1.1-1 100 14.0 1 2 Blue PA V0 XW5T-S.0-1.1-1BL 100 14 10.0 1 2 Dark gray PA V0 XW5T-S10-1.1-1 50 17 10.0 1 2 Blue PA V0 XW5T-S10-1.1-1BL 50 17 1.0 1 2 Dark gray PA V0 XW5T-S1-1.1-1 50 37 1.0 1 2 Blue PA V0 XW5T-S1-1.1-1BL 50 37 35.0 1 2 Dark gray PA V0 XW5T-S35-1.1-1 20 74 35.0 1 2 Blue PA V0 XW5T-S35-1.1-1BL 20 74 70.0 1 2 Dark gray PA V0 XW5T-S70-1.1-1 20 177 70.0 1 2 Blue PA V0 XW5T-S70-1.1-1BL 20 177 150.0 1 2 Dark gray PA V0 XW5T-S150-1.1-1 10 281 150.0 1 2 Blue PA V0 XW5T-S150-1.1-1BL 10 282 2.5 2 2 Dark gray PA V0 XW5T-S2.5-1.1-2 100 13 2.5 2 2 Black PA V0 XW5T-S2.5-1.1-2V 100 15 4.0 2 2 Dark gray PA V0 XW5T-S4.0-1.1-2 100 19 4.0 2 2 Black PA V0 XW5T-S4.0-1.1-2V 100 20 4.0 1 3 PA V0 XW5T-S4.0-1.2-1 100 13 Dark gray 4.0 1 4 PA V0 XW5T-S4.0-2.2-1 100 17 4.0 1 3 PA V0 XW5T-S4.0-1.2-1BL 100 13 Blue 4.0 1 4 PA V0 XW5T-S4.0-2.2-1BL 100 17 2.5 1 2 PA V0 XW5G-S2.5-1.1-1 100 10 4.0 1 2 PA V0 XW5G-S4.0-1.1-1 100 12.0 1 2 PA V0 XW5G-S.0-1.1-1 100 20 Standard terminals 10.0 1 2 PA V0 XW5G-S10-1.1-1 50 23 1.0 1 2 Green/ PA V0 XW5G-S1-1.1-1 50 47 35.0 1 2 yellow PA V0 XW5G-S35-1.1-1 20 123 70.0 1 2 PA V0 XW5G-S70-1.1-1 20 240 Multi tiers terminal 4.0 2 2 PA V0 XW5G-S4.0-1.1-2 100 23 Multi conductor 4.0 1 3 PA V0 XW5G-S4.0-1.2-1 100 1 terminals 4.0 1 4 PA V0 XW5G-S4.0-2.2-1 100 20 Fuse terminal 4.0 1 2 PA V0 XW5T-S4.0-FU5 50 19 4.0 1 2 Dark gray PA V0 XW5T-S4.0-FU 50 22 Knife edge disconnect block 4.0 1 2 PA V0 XW5T-S4.0-KD 100 12 2

Accessories Short Bars For XW5 -S2.5-2 No. of poles Color Model For XW5 -S4.0- For XW5 -S.0- For XW5 -S10- For XW5 -S1- Cross Connector with Screw For XW5 -S2.5-1.1-2 End Covers Pack (pcs.) XW5S-S2.5-2 10 3 XW5S-S2.5-3 10 4 Yellow (YL) XW5S-S2.5-4 10 5 XW5S-S2.5-5 10 10 XW5S-S2.5-10 20 2 No. of poles Color Model Pack (pcs.) XW5S-S4.0-2 10 3 XW5S-S4.0-3 10 4 Yellow (YL) XW5S-S4.0-4 10 5 XW5S-S4.0-5 10 10 XW5S-S4.0-10 20 2 No. of poles Color Model Pack (pcs.) XW5S-S.0-2 10 3 XW5S-S.0-3 10 Yellow (YL) 4 XW5S-S.0-4 10 5 XW5S-S.0-5 10 No. of poles Color Model Pack (pcs.) 2 Yellow (YL) XW5S-S10-2 10 No. of poles Color Model Pack (pcs.) 2 Yellow (YL) XW5S-S1-2 10 2 No. of poles Color Model Pack (pcs.) XW5S-S2.5-2N 10 3 XW5S-S2.5-3N 10 4 Yellow (YL) XW5S-S2.5-4N 10 5 XW5S-S2.5-5N 10 10 XW5S-S2.5-10N 10 Applicable Terminal Blocks XW5 -S2.5-1.1- XW5 -S4.0-1.1- XW5 -S.0-1.1- XW5 -S10-1.1- Model Pack (pcs.) XW5E-S2.5 10 XW5T-S1-1.1- XW5E-S1 10 XW5T-S4.0-KD XW5 -S4.0-1.2-1 XW5E-S4.0-1.2-1 10 XW5 -S4.0-2.2-1 XW5E-S4.0-2.2-1 10 XW5 -S4.0-1.1-2 XW5E-S4.0-1.1-2 10 XW5T-S2.5-1.1-2 XW5E-S2.5N 10 Separator Plates Applicable Terminal Blocks XW5 -S2.5-1.1- XW5 -S4.0-1.1- XW5 -S.0-1.1- XW5 -S10-1.1- Labels Applicable Terminal Blocks XW5 -S2.5- XW5 -S4.0- XW5 -S.0- Marking * Box including 250 pcs. Model Pack (pcs.) XW5Z-S2.5PT 10 Model Pack (pcs.) None XW5Z-S2.5LB 25 1-10 XW5Z-S2.5LB-1-10 25 11-20 XW5Z-S2.5LB-11-20 25 21-30 XW5Z-S2.5LB-21-30 25 31-40 XW5Z-S2.5LB-31-40 25 41-50 XW5Z-S2.5LB-41-50 25 51-0 XW5Z-S2.5LB-51-0 25 1-70 XW5Z-S2.5LB-1-70 25 71-80 XW5Z-S2.5LB-71-80 25 81-90 XW5Z-S2.5LB-81-90 25 91-100 XW5Z-S2.5LB-91-100 25 1-100 XW5Z-S2.5LB-1-100 1 * None XW5Z-S4.0LB 25 1-10 XW5Z-S4.0LB-1-10 25 11-20 XW5Z-S4.0LB-11-20 25 21-30 XW5Z-S4.0LB-21-30 25 31-40 XW5Z-S4.0LB-31-40 25 41-50 XW5Z-S4.0LB-41-50 25 51-0 XW5Z-S4.0LB-51-0 25 1-70 XW5Z-S4.0LB-1-70 25 71-80 XW5Z-S4.0LB-71-80 25 81-90 XW5Z-S4.0LB-81-90 25 91-100 XW5Z-S4.0LB-91-100 25 1-100 XW5Z-S4.0LB-1-100 1 * None XW5Z-S.0LB 25 1-10 XW5Z-S.0LB-1-10 25 11-20 XW5Z-S.0LB-11-20 25 21-30 XW5Z-S.0LB-21-30 25 31-40 XW5Z-S.0LB-31-40 25 41-50 XW5Z-S.0LB-41-50 25 51-0 XW5Z-S.0LB-51-0 25 1-70 XW5Z-S.0LB-1-70 25 71-80 XW5Z-S.0LB-71-80 25 81-90 XW5Z-S.0LB-81-90 25 91-100 XW5Z-S.0LB-91-100 25 1-100 XW5Z-S.0LB-1-100 1 * 3

Ratings and Specifications Feed Through Terminal Blocks Model XW5T-S2.5-1.1-1(BL) XW5T-S4.0-1.1-1(BL) XW5T-S.0-1.1-1(BL) XW5T-S10-1.1-1(BL) 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 Appearance and internal wiring NOMINAL CROSS SECTION 2.5 mm 2 4.0 mm 2.0 mm 2 10 mm 2 Minimum conductor cross section solid 0.14 mm 2 0.14 mm 2 0.2 mm 2 0.5 mm 2 Maximum conductor cross section solid 4.0 mm 2.0 mm 2 10 mm 2 1 mm 2 Minimum conductor cross section fine 0.14 mm 2 0.14 mm 2 0.2 mm 2 0.5 mm 2 Maximum conductor cross section fine 4.0 mm 2.0 mm 2 10 mm 2 1 mm 2 Minimum conductor cross section (flex., ) with cable 0.5 mm 2 0.5 mm 2 0.5 mm 2 0.5 mm 2 end sleeve Maximum conductor cross section (flex., ) with cable 2.5 mm 2 4.0 mm 2.0 mm 2 10 mm 2 end sleeve Conductor cross section AWG AWG2 to AWG12 AWG2 to AWG10 AWG24 to AWG8 AWG20 to AWG Wire strip length 9 mm 9 mm 11 mm 13 mm Tightening torque 0.4 Nm 0.5 Nm 1.2 Nm 1.2 Nm Dimensions 5 48.2 48.2 8 48.2 10 48.2.2 Applicable wire sizes TH35 TH35 TH35 TH35 IEC rated voltage 1,000 V 1,000 V 1,000 V 1,000 V IEC rated current 24 A 32 A 41 A 57 A Rated impulse voltage 8 kv 8 kv 8 kv 8 kv UL rated voltage 00 V 00 V 00 V 00 V UL rated current 20 A 30 A 50 A 5 A End Covers XW5E-S2.5-1.1-1 XW5E-S2.5-1.1-1 XW5E-S2.5-1.1-1 XW5E-S2.5-1.1-1 Applicable nameplates XW5Z-S2.5LB XW5Z-S4.0LB@ XW5Z-S.0LB@ --- Applicable Short Bars XW5S-S4.0-@ (@: Poles = 2, 3, 4, 5 or 10) XW5S-S4.0-@ (@: Poles = 2, 3, 4, 5 or 10) XW5S-S.0-@ (@: Poles = 2,3, 4, or 5) XW5S-S10-@ (@: Poles = 2) 4

Feed Through Terminal Blocks Model XW5T-S1-1.1-1(BL) XW5T-S35-1.1-1(BL) XW5T-S70-1.1-1(BL) XW5T-S150-1.1-1(BL) 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 Appearance and internal wiring NOMINAL CROSS SECTION 1 mm 2 35 mm 2 70 mm 2 150 mm 2 Minimum conductor cross section solid 1.5 mm 2 10 mm 2 --- --- Maximum conductor cross section solid 1 mm 2 10 mm 2 --- --- Minimum conductor cross section fine 4.0 mm 2 10 mm 2 10 mm 2 35 mm 2 Maximum conductor cross section fine 25 mm 2 35 mm 2 70 mm 2 150 mm 2 Minimum conductor cross section (flex., ) with cable 1.5 mm 2 --- --- --- end sleeve Maximum conductor cross section (flex., ) with cable 1 mm 2 --- --- --- end sleeve Conductor cross section AWG AWG14 to AWG4 AWG10 to AWG 1/0 AWG to AWG 2/0 AWG 2/0 to 350 kcmil Wire strip length 15 mm 18 mm 24 mm 30 mm Tightening torque 2 Nm 3 Nm Nm 10 Nm Dimensions 12 58.5 2 1 3 75.1 24 75.2 88.7 28 9 10.1 TH35 TH35 TH35 TH35 IEC rated voltage 1,000 V 800 V 800 V 1,000 V IEC rated current 7 A 124 A 179 A 309 A Rated impulse voltage 8 kv 8 kv 8 kv 8 kv UL rated voltage 00 V 00 V 00 V 00 V UL rated current 85 A 150 A 175 A 335 A End Covers XW5E-S1 Applicable nameplates --- --- --- --- Applicable Short Bars XW5S-S1-@ (@: Poles = 2) --- --- --- Applicable wire sizes 5

Feed Through Terminal Blocks Model XW5T-S2.5-1.1-2 XW5T-S2.5-1.1-2V XW5T-S4.0-1.2-1(BL) 2 tiers, 2:2 2 tiers, 2:2 1 tier, 1:2 Appearance and internal wiring NOMINAL CROSS SECTION 2.5 mm 2 2.5 mm 2 4.0 mm 2 Minimum conductor cross section solid 0.2 mm 2 0.2 mm 2 0.14 mm 2 Applicable wire sizes Maximum conductor cross section solid 4.0 mm 2 4.0 mm 2.0 mm 2 Minimum conductor cross section fine Maximum conductor cross section fine 0.14 mm 2 0.14 mm 2 0.14 mm 2 2.5 mm 2 2.5 mm 2.0 mm 2 Minimum conductor cross section (flex., ) with cable end sleeve --- --- 0.5 mm 2 Maximum conductor cross section (flex., ) with cable end sleeve --- --- 4.0 mm 2 Conductor cross section AWG AWG22 to AWG12 AWG22 to AWG12 AWG2 to AWG10 Wire strip length 8 mm 8 mm 9 mm Tightening torque 0.4 Nm 0.4 Nm 0.5 Nm Dimensions 5 5.8 71.4 5 5.8 71.4 58 TH35 TH35 TH35 IEC rated voltage 500 V 500 V 500 V IEC rated current 24 A 24 A 32 A Rated impulse voltage kv kv kv UL rated voltage 00 V 00 V 300 V UL rated current 20 A 20 A 30 A End Covers XW5E-S2.5N XW5E-S2.5N XW5E-S4.0-1.2-1 Applicable nameplates XW5Z-2.5LB@ XW5Z-2.5LB@ XW5Z-4.0LB@ Applicable Short Bars XW5S-S2.5-@N (@: Poles = 2, 3, 4, 5, or 10) XW5S-S2.5-@N (@: Poles = 2, 3, 4, 5, or 10) XW5S-S4.0-@ (@: Poles = 2, 3, 4, 5, or 10)

Feed Through Terminal Blocks Model XW5T-S4.0-2.2-1(BL) XW5T-S4.0-1.1-2 XW5T-S4.0-1.1-2V 1 tier, 2:2 2 tiers, 1:1 2 tiers, 1:1 Appearance and internal wiring NOMINAL CROSS SECTION 4.0 mm 2 4.0 mm 2 4.0 mm 2 Minimum conductor cross section solid 0.14 mm 2 0.14 mm 2 0.14 mm 2 Applicable wire sizes Maximum conductor cross section solid.0 mm 2.0 mm 2.0 mm 2 Minimum conductor cross section fine Maximum conductor cross section fine Minimum conductor cross section (flex., ) with cable end sleeve 0.14 mm 2 0.14 mm 2 0.14 mm 2.0 mm 2.0 mm 2.0 mm 2 0.5 mm 2 0.5 mm 2 0.5 mm 2 Maximum conductor cross section (flex., ) with cable end sleeve 4.0 mm 2 4.0 mm 2 4.0 mm 2 Conductor cross section AWG AWG2 to AWG10 AWG2 to AWG10 AWG2 to AWG10 Wire strip length 9 mm 9 mm 9 mm Tightening torque 0.5 Nm 0.5 Nm 0.5 Nm Dimensions 9 58 73 75 73 75 TH35 TH35 TH35 IEC rated voltage 500 V 800 V 800 V IEC rated current 32 A 32 A 32 A Rated impulse voltage kv 8 kv 8 kv UL rated voltage 300 V 300 V 300 V UL rated current 30 A 30 A 30 A End Covers XW5E-S4.0-2.2-1 XW5E-S4.0-1.1-2 XW5E-S4.0-1.1-2 Applicable nameplates XW5Z-4.0LB@ XW5Z-4.0LB@ XW5Z-4.0LB@ Applicable Short Bars XW5S-S4.0-@ (@: Poles = 2, 3, 4, 5, or 10) XW5S-S4.0-@ (@: Poles = 2, 3, 4, 5, or 10) XW5S-S4.0-@ (@: Poles = 2, 3, 4, 5, or 10) 7

Grounding Terminal Blocks Model XW5G-S2.5-1.1-1 XW5G-S4.0-1.1-1 XW5G-S.0-1.1-1 XW5G-S10-1.1-1 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 Appearance and internal wiring NOMINAL CROSS SECTION 2.5 mm 2 4.0 mm 2.0 mm 2 10 mm 2 Minimum conductor cross section solid 0.14 mm 2 0.14 mm 2 0.2 mm 2 0.5 mm 2 Applicable wire sizes Maximum conductor cross section solid 4.0 mm 2.0 mm 2 10 mm 2 1 mm 2 Minimum conductor cross section fine Maximum conductor cross section fine 0.14 mm 2 0.14 mm 2 0.2 mm 2 0.5 mm 2 4.0 mm 2.0 mm 2 10 mm 2 1 mm 2 Minimum conductor cross section (flex., ) with cable end sleeve 0.5 mm 2 0.5 mm 2 0.5 mm 2 0.5 mm 2 Maximum conductor cross section (flex., ) with cable end sleeve 2.5 mm 2 4.0 mm 2.0 mm 2 10 mm 2 Conductor cross section AWG AWG2 to AWG12 AWG2 to AWG10 AWG24 to AWG8 AWG20 to AWG Wire strip length 9 mm 9 mm 11 mm 13 mm Tightening torque 0.4 Nm 0.5 Nm 1.2 Nm 1.2 Nm Dimensions 5 48.2 48.2 8 48.2 10 48.2.2 TH35 TH35 TH35 TH35 IEC rated voltage 1,000 V 1,000 V 1,000 V 1,000 V IEC rated current --- --- --- --- Rated impulse voltage 8 kv 8 kv 8 kv 8 kv UL rated voltage 00 V 00 V 00 V 00 V UL rated current --- --- --- --- End Covers XW5E-S2.5 XW5E-S2.5 XW5E-S2.5 XW5E-S2.5 Applicable nameplates XW5Z-S2.5LB@ XW5Z-S4.0LB@ XW5Z-S.0LB@ --- Applicable Short Bars --- --- --- --- 8

Grounding Terminal Blocks Model XW5G-S1-1.1-1 XW5G-S35-1.1-1 XW5G-S70-1.1-1 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 Appearance and internal wiring Applicable wire sizes NOMINAL CROSS SECTION 1 mm 2 35 mm 2 70 mm 2 Minimum conductor cross section solid 1.5 mm 2 10 mm 2 --- Maximum conductor cross section solid 1 mm 2 35 mm 2 --- Minimum conductor cross section fine Maximum conductor cross section fine Minimum conductor cross section (flex., ) with cable end sleeve 4.0 mm 2 10 mm 2 10 mm 2 25 mm 2 35 mm 2 70 mm 2 1.5 mm 2 --- --- Maximum conductor cross section (flex., ) with cable end sleeve 1 mm 2 --- --- Conductor cross section AWG AWG14 to AWG4 AWG10 to AWG2 AWG to AWG 2/0 Wire strip length 15 mm 20 mm 24 mm Tightening torque 2 Nm 3 Nm Nm Dimensions 12 58.5 2 1 3 75.1 24 75.2 88.7 TH35 TH35 TH35 IEC rated voltage 1000 V 800 V 800 V IEC rated current --- --- --- Rated impulse voltage 8 kv 8 kv 8 kv UL rated voltage 00 V 00 V 00 V UL rated current --- --- --- End Covers XW5E-S1 --- --- Applicable nameplates --- --- --- Applicable Short Bars --- --- --- 9

Grounding Terminal Blocks Model XW5G-S4.0-1.2-1 XW5G-S4.0-2.2-1 XW5G-S4.0-1.1-2 1 tier, 1:2 1 tier, 2:2 2 tiers, 1:1 Appearance and internal wiring NOMINAL CROSS SECTION 4.0 mm 2 4.0 mm 2 4.0 mm 2 Minimum conductor cross section solid 0.14 mm 2 0.14 mm 2 0.14 mm 2 Applicable wire sizes Maximum conductor cross section solid mm 2 mm 2 mm 2 Minimum conductor cross section fine Maximum conductor cross section fine 0.14 mm 2 0.14 mm 2 0.14 mm 2 mm 2 mm 2 mm 2 Minimum conductor cross section (flex., ) with cable end sleeve 0.5 mm 2 0.5 mm 2 0.5 mm 2 Maximum conductor cross section (flex., ) with cable end sleeve 4 mm 2 4 mm 2 4 mm 2 Conductor cross section AWG AWG2 to AWG10 AWG2 to AWG10 AWG2 to AWG10 Wire strip length 9 mm 9 mm 9 mm Tightening torque 0.5 Nm 0.5 Nm 0.5 Nm Dimensions 58 9 58 73 75 TH35 TH35 TH35 IEC rated voltage 500 V 500 V 800 V IEC rated current --- --- --- Rated impulse voltage kv kv 8 kv UL rated voltage 300 V 300 V 300 V UL rated current --- --- --- End Covers XW5E-S4.0-1.2-1 XW5E-S4.0-2.2-1 XW5E-S4.0-1.1-2 Applicable nameplates XW5Z-4.0LB@ XW5Z-4.0LB@ XW5Z-4.0LB@ Applicable Short Bars --- --- --- 10

Terminal Blocks with Fuses Model XW5T-S4.0-FU5 XW5T-S4.0-FU 1 tier, 1:1 1 tier, 1:1 Appearance and internal wiring NOMINAL CROSS SECTION 4.0 mm 2 4.0 mm 2 Minimum conductor cross section solid 0.5 mm 2 0.5 mm 2 Maximum conductor cross section solid mm 2 mm 2 Minimum conductor cross section fine 0.5 mm 2 0.5 mm 2 Maximum conductor cross section fine 4 mm 2 4 mm 2 Minimum conductor cross section (flex., ) with cable end sleeve --- --- Maximum conductor cross section (flex., ) with cable end sleeve --- --- Conductor cross section AWG AWG22 to AWG10 AWG22 to AWG10 Wire strip length 8 mm 8 mm Tightening torque 0.5 Nm 0.5 Nm Dimensions 8 77.2 2 10 77.2 2 TH35 TH35 IEC rated voltage 800 V 800 V IEC rated current.3 A 10 A Rated impulse voltage 8 kv 8 kv UL rated voltage 00 V 00 V UL rated current 15 A 15 A End Covers --- --- Applicable nameplates --- --- Applicable Short Bars --- --- Applicable wire sizes Technical Information for XW5T-S4.0-FU5, XW5T-S4.0-FU The fuse blocks of this type have a flip top disconnect lever. It accepts miniature fuses of 5 20, 5 25 and 5 30 mm (terminal width: 8 mm) or.3 32 mm (terminal width: 10 mm). The hinged lever has latch points both in the open and in the closed position, and can be sealed. Depending on the application and the installation method, the circumstances for increased temperature must be checked in the closed fuse holders. Higher ambient temperatures are an additional load for the fuse inserts. Therefore, the reduction of the rated current must be considered accordingly in these applications. 11

Disconnect Terminal Blocks Model XW5T-S4.0-KD 1 tier, 1:1 Appearance and internal wiring Applicable wire sizes NOMINAL CROSS SECTION 4.0 mm 2 Minimum conductor cross section solid 0.14 mm 2 Maximum conductor cross section solid mm 2 Minimum conductor cross section fine 0.14 mm 2 Maximum conductor cross section fine mm 2 Minimum conductor cross section (flex., ) with cable end sleeve 0.5 mm 2 Maximum conductor cross section (flex., ) with cable end sleeve 4 mm 2 Conductor cross section AWG AWG2 to AWG10 Wire strip length 9 mm Tightening torque 0.5 Nm Dimensions 58 58 TH35 IEC rated voltage 500 V IEC rated current 20 A Rated impulse voltage kv UL rated voltage 300 V UL rated current 1 A End Covers XW5E-S4.0-1.2-1 Applicable nameplates XW5Z-S4.0LB@ Applicable Short Bars XW5S-S4.0-@ Short Bar Model XW5S-S2.5- XW5S-S4.0- XW5S-S.0- XW5S-S10- XW5S-S1- IEC rated voltage 00 V 1,000 V IEC rated current 20 A 30 A 50 A 57 A 7 A UL rated voltage 00 V UL rated current 20 A 30 A 50 A 5 A 85 A Compliant standards UL IEC0947-7-1 Characteristics Operating temperature range -40 to 0 C (with no condensation or icing) Insulating material PA Flammability rating according to UL 94 V0 Operating humidity range 5% to 95% Compliant standards culus (UL 1059), IEC 0947-7-1 and IEC 0947-7-2 Vibration resistance 5 to 150 Hz 0.94 (m/s 2 ) 2 /Hz Shock resistance 50 m/s 2 30 ms according EN 1373 12

Dimensions (Unit: mm) Feed Through Terminal Blocks XW5T-S2.5-1.1-1 XW5T-S4.0-1.1-1 5 48.2 44 48.2 44 48. 47.8 41 4.8 48. 47.8 41 4.8 42.2 42.2 XW5T-S.0-1.1-1 XW5T-S10-1.1-1 8 10 48.2 44 48.2 44 48. 47.8 41 4.8.2 48. 47.8 48..2 42.2 42.2 XW5T-S1-1.1-1 XW5T-S35-1.1-1 12 1 58.5 57.5 3 2 54.5 53.7 47 52.8 75.1 9 7. 27.9 29.3 35.4 47.25 13.85 G-rail EN 0715-G32 13

XW5T-S70-1.1-1 XW5T-S150-1.1-1 24 28 75.2 9 91.7 88.7 82.7 81.2 1.4 29. 31.1 37.1 10.1 100.1 98. G-rail EN 0715-G32 19.95 25.8 27.3 33.3 G-rail EN 0715-G32 Mouting rail 28.25 XW5T-S2.5-1.1-2 XW5T-S4.0-1.2-1 5 5.8 34 58 3.9 8.4 71.4 48 47.8 43 48.8 G-rail EN 0715-G32 42.2 XW5T-S4.0-2.2-1 XW5T-S4.0-1.1-2 9 8 73 37.7 72 58 50 75 7 52.4 54.5 14

XW5T-S4.0-FU5 XW5T-S4.0-FU 8 10 77.2 77.2 54.5 59 2 54.5 59 2. G-rail EN 0715-G 32. EN 0715-35x15 G-rail EN 0715-G 32 XW5T-S4.0-KD 58 58 50 42.2 Grounding Terminal Blocks XW5G-S2.5-1.1-1 XW5G-S4.0-1.1-1 5 48.2 44 48.2 44 48. 47.8 41 4.8 48. 47.8 41 4.8 42.2 42.2 XW5G-S.0-1.1-1 XW5G-S10-1.1-1 8 10 48.2 44 48.2 44 48. 47.8 41 4.8 48. 47.8 41 4.8 42.2 42.2 15

XW5G-S1-1.1-1 XW5G-S35-1.1-1 12 1 58.5 57.5 3 2 54.5 53.7 47 52.8 75.1 9 7. 27.9 29.3 35.4 47.25 13.85 G-rail EN 0715-G32 XW5G-S70-1.1-1 XW5G-S4.0-1.2-1 24 58. 75.2 48. 47.8 43 48.8 88.7 82.7 81.2 29. 1.4 31.1 37.1 42.2 G-rail EN 0715-G32 19.95 XW5G-S4.0-2.2-1 XW5G-S4.0-1.1-2 9 8 73 37.7 72 58 50 75 7 52.4 54.5 1

Short Bars XW5S-S2.5- L (5) l (2.1) (14) (23.9) (1.5) For XW5 -S2.5- Model I (mm) L (mm) XW5S-S2.5-2 5 10 XW5S-S2.5-3 10 15 XW5S-S2.5-4 15 20 XW5S-S2.5-5 20 25 XW5S-S2.5-10 45 50 XW5S-S4.0- For XW5 -S4.0- L l 23.9 14 2.4 1.75 Model I (mm) L (mm) XW5S-S4.0-2 12 XW5S-S4.0-3 12 18 XW5S-S4.0-4 18 24 XW5S-S4.0-5 24 30 XW5S-S4.0-10 54 0 XW5S-S.0- L 3 For XW5 -S.0- Model I (mm) L (mm) 9 XW5S-S.0-2 8.2 14.7 29. XW5S-S.0-3 1.4 22.9 XW5S-S.0-4 24. 31.1 l 1. XW5S-S.0-5 32.8 39.3 XW5S-S10-2 XW5S-S1-2 17.8 4 20.5 5.4 15.2 18.5 35 35.8 10.2 2.4 12.2 3. Cross Connector with Screw XW5S-S2.5- N For XW5 -S2.5-1.1-2 5 L l 9.1 0.8 5 M2.5 Model I (mm) L (mm) XW5S-S2.5-2N 5 8.9 XW5S-S2.5-3N 10 13.9 XW5S-S2.5-4N 15 18.9 XW5S-S2.5-5N 20 23.9 XW5S-S2.5-10N 45 48.9 17

End Covers XW5E-S2.5 XW5E-S1 44 57.5 40. 4. 47 XW5E-S4.0-1.2-1 XW5E-S4.0-2.2-1 57.4 55.9 7.8 42 40.7 42.7 42. 40. XW5E-S4.0-1.1-2 37.7 72 XW5E-S2.5N 33.8 59.5 53.2 2.5 35.4 32.1 33.7 Separator Plates XW5Z-S2.5PT 50.5 49 52.7 4.1 18

Label XW5Z-S2.5 4.8 9 5=45 5 8.3 XW5Z-S4.0 59.5 5.75 9 =54 8.3 XW5Z-S.0 7.75 79.5 9 8=72 8 8.3 19

Safety Precautions Be sure to read the precautions for all models in the website at the following URL: http://www.ia.omron.com/. Signal Word Definitions Precautions for Safe Use Precautions for Correct Use Supplementary comments on what to do or avoid doing, to use the product safely. Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction, or undesirable effects on product performance. Precautions for Safe Use Do not bend a wire past its natural bending radius or pull on it with excessive force. Doing so may cause the wire disconnection. Do not insert more than one wire into each terminal insertion hole. Before you start wiring, make sure that the Terminal Block is securely attached and mounted to a DIN Track. If the Terminal Block is not stable, it may fall and possibly injure a worker. Do not install the Terminal Block upside down when mounting multiple Terminal Blocks. Doing so may cause short circuits with the adjacent Terminal Block. Precautions for Correct Use 1. Precautions for Correct Use Do not drop the Terminal Block. Terminal Block functionality may be inhibited. Always attach End Cover. Not doing so may cause electrical shock. When you wire the Terminal Block, do not subject it or the wires to stress. Secure the wires so that they do not resonate with vibrations from the facilities in installation conditions. Always turn OFF the power supply before wiring. Electrical shock may occur. 2. Connecting Wires to the Terminal Block Wiring Double-check all wiring before turning ON the power supply. After wiring, route the cable so that force is not applied directly to the connections. Wires for Terminal Blocks Do not damage the cores when stripping the insulation from them. Always twist wires together before connecting them. Do not presolder wires. It may not be possible to connect them or remove them. Screw Tightening Torque and Applicable Wires When you connect wires to a Terminal Block, use the applicable wires and tightening torque given in the following table. Model Wiring method Tightening torque [N m] (Use a flatblade screwdriver.) Applicable wire sizes Applicable wire sizes with ferrules attached XW5@-S2.5 M2.5 0.4 AWG2-AWG12 AWG20-AWG14 XW5@-S4.0 M3 0.5 AWG2-AWG10 AWG20-AWG12 XW5@-S.0 M4 1.2 AWG24-AWG8 AWG20-AWG10 XW5@-S10 M4 1.2 AWG20-AWG AWG20-AWG8 XW5@-S1 M5 2 AWG12-AWG4 AWG12-AWG XW5@-S35 M 2.5 AWG10-AWG1/0 AWG10-AWG2 XW5@-S70 M8 3.5 AWG-AWG2/0 AWG-AWG2/0 XW5@-S150 M10 4 AWG2/0-350kcmil AWG2/0-300kcmil Wire Stripping Lengths If you connect wires directly to the terminals, use the following stripping lengths. Model Stripping length [mm] XW5@-S2.5 9 XW5@-S4.0 9 XW5@-S.0 11 XW5@-S10 13 XW5@-S1 15 XW5@-S35 18 XW5@-S70 24 XW5@-S150 30 3. Mounting to and Removing from DIN Track Mounting Procedure Removal Procedure (2) Press. (1) Hook. Hook the Unit on the DIN Track. 2. Press the Unit onto the DIN Track to secure it. Insert a flat-blade screwdriver into the DIN Track lock. 2. Move the screwdriver like a lever to free the lock. 20

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.

OMRON Corporation Industrial Automation Company Kyoto, JAPAN Contact: www.ia.omron.com Authorized Distributor: Regional Headquarters OMRON EUROPE B.V. Wegalaan 7-9, 2132 JD Hoofddorp The Netherlands Tel: (31)23-81-300/Fax: (31)23-81-388 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 11997 Tel: (5) 835-3011/Fax: (5) 835-2711 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 019 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (8) 21-5037-2222/Fax: (8) 21-5037-2200 OMRON Corporation 201 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_1_4_1217 Cat. No. G125-E1-02 091 (031)