F&J SPECIALTY PRODUCTS, INC. The Nucleus of Quality Air Monitoring Programs BATTERY BANK POWERED AC/DC AIR SAMPLERS DF-EDL-400-AC DF-EDL-400E-AC Portable Battery Bank 24V 18Ah Battery Pack 33.6 lbs. (~15.24 kgs.) BATBANK-24V DF-EDL-500-AC DF-EDL-500E-AC REV: 19 Sep. 2018
Portable 24V External Battery Bank for F&J AC/DC Air Samplers Model BATBANK-24V NOTABLE FEATURES: Internal battery charging system operable from line power input (100 240VAC, 50/60 Hz) Digital and graphical battery capacity indicator (LCD) Small dimensioned, water tight enclosure with a large rugged plastic handle for easy carry Water tight connection port for powering units outdoors GENERAL DESCRIPTION: BATBANK-24V Top View F&J model BATBANK-24V is a light one man carry 24V battery bank for use with 24 VDC powered F&J air samplers. The battery bank is approximately 18 Ah and is housed in a small foot print water tight enclosure. The BATBANK-24V can be charged by plugging it into line power (100 240VAC, 50/60Hz) and provides short circuit/reverse polarity protection. The BATBANK-24V includes an LCD display for voltage level and percent capacity of the battery bank. It is provided with a power cord for charging the system and a DC cord for connection to 24VDC powered F&J AC/DC air samplers. Frontal View of BATBANK-24V View illustrating water proof AC and DC cord connection chamber
Battery Type: Battery Charging System: Enclosure: Weight: Dimensions: Display: Sealed Lead Acid Battery 24V 18Ah Battery Pack Low Self discharge (~3% capacity/month) Internal battery charging system operable from line power (100 240VAC, 50/60Hz) Short circuit / Reverse Polarity Protector Rugged water tight plastic enclosure with a large durable handle 33.6 lbs (~15.24 kgs) 16.8 L x 9.0 W x 14.0 H (42.7 x 22.9 x 35.6 cm) Bright digital and graphical LCD battery capacity indicator Optional Rain Shield Filter Holder Air Sampler Connected to a Portable Battery Bank AC/DC Air Sampler P/N: TP-4 Battery Bank Inside View BATBANK-24V Lead Acid Batteries And Charger and Digital Battery Capacity LCD Indicator Battery Capacity Indicator View Tripod mounted and coupled to battery bank
ELITE DIGITAL LIGHT (EDL) AIR SAMPLER F&J Model DF-EDL-400-AC NOTABLE FEATURES: State-of-the-Art Electronics Lightweight: 18.55 lbs. (8.41 kg) Powerful flow rate to 160 SLPM Very low maintenance Automatic Flow Control Operator selectable Ambient or Reference flow T and P Conditions Auto shut-off on time or volume RS232 Communication port Brushless motor Optional 24 VDC input connector for external DC Power operation Optional rain shielded filter holder Optional battery bank for situations where line power is not available GENERAL DESCRIPTION: Displayed with Optional Rain Hood and Filter Holder F&J Model DF-EDL-400-AC is a powerful portable AC/DC powered air sampling system operable from (1) line power or (2) an optional 24VDC external power source. This powerful unit is a low volume air sampler enclosed in a solid wall, strong, water tight enclosure. It has double throw latches for easy access with a comfortable rubber over-molded handle for easy transport. The DF-EDL-400-AC air sampler is well suited for various types of air sampling applications such as emergency response and work area monitoring programs. It can also be utilized in remote air sampling applications powered from solar panels or wind turbines. The F&J Digital Flowmeter technology provides maximum flexibility, flow rate normalization, automatic flow control and opportunities for data collection through the RS232 communication port. The typical operating flow range is 20-160 SLPM (0.7 5.65 SCFM). Actual flow range implemented will depend on the filter(s) utilized by the customer. Indoor Mode Outdoor Mode Instrument Panel
Pump Type: Centrifugal blower Maximum Flowrate: 115.8 LPM - Typical w/47 mm FP47M glass fiber media 156.5 + LPM FP-4.0M 168.5 SLPM Free Air Flow capacity Power Source: Line Power; 100VAC to 120VAC External DC Source 24VDC (option) Maximum Current Draw: 4 A maximum on line power 6 A maximum on 24 VDC Filter Holder Fitting: 3/8 FNPT quick disconnect Handle: Weight: Durable plastic 18.55 lbs. (8.41 kg) Installation Category: Pollution Degree 2 Enclosure Rating: IPX2 Average dba: 61 at 94.8 SLPM using FP-47M + TE3C Dimensions: 16.8 L 9.0 W 14.0 H (42.7 22.8 35.5 cm) Operating Temperature Range: 14 F to 104 F (-10 C to 40 C) Display: Bright LED (6 character, 1.2 cm H) Elapsed Time: DD:HH:MM up to 168 hours Flow Control: Adjustable from keypad between 20-160 LPM (Depending on filter media being used) Flow Accuracy: ±4.0% of Full Scale Factory Settable Reference T and P Classical STP 0ºC, 1 ATM Normal T and P 20ºC, 1 ATM Modified Normal T and P 70ºF, 1 ATM Standard Ambient T and P 25ºC, 1 ATM OPTIONS: Data Storage Device (P/N: 232FCDSD) 2+ GB Secure Digital Card (P/N: 372239) Flash card Reader (P/N: SDDR-199-A20) Combination Filter Holder with Rain Hood 47mm Particulate / C Geometry FJ-47RH 50mm Particulate / C Geometry FJ-50RH Battery Bank (P/N: BATBANK-24V) Standard Combination Filter Holders Available: FILTER HOLDER MODEL CHARCOAL CARTRIDGE DIMENSIONS PARTICULATE PAPER DIAME- TER FJ-05P F&J Model B 2 or 50 mm FJ-21P F&J Model C 2 or 50 mm FJ-35P F&J Model B 47 mm FJ-46P F&J Model C 47 mm FJ-51P F&J Model M 2 or 50 mm FJ-53P F&J Model M 47 mm Available Engineering Units for Flow and Volume: sccm / scc SLPM / SLP SCFM / SCF SCMH / SCM Digital Flow Meter Keypad/Display Flow / Volume: SLPM/SL 100.00
ELITE DIGITAL LIGHT (EDL) AIR SAMPLER F&J Model DF-EDL-400E-AC NOTABLE FEATURES: State-of-the-Art Electronics Lightweight: 18.55 lbs. (8.41 kg) Powerful: Flow rate to 160 SLPM Very low maintenance Automatic Flow Control Operator selectable Ambient or Reference flow T and P Conditions Auto shut-off on time or volume RS232 Communication port Brushless motor Optional 24 VDC input connector for external DC Power operation Optional rain shielded filter holder Optional battery bank for situations where line power is not available GENERAL DESCRIPTION: Displayed with Optional Rain Hood and Filter Holder F&J Model DF-EDL-400E-AC is a powerful portable AC/DC powered air sampling system operable from (1) line power or (2) an optional 24VDC external power source. This powerful unit is a low volume air sampler enclosed in a solid wall, strong, water tight enclosure. It has double throw latches for easy access with a comfortable rubber over-molded handle for easy transport. The DF-EDL-400E-AC air sampler is well suited for various types of air sampling applications such as emergency response and work area monitoring programs. It can also be utilized in remote air sampling applications powered from solar panels or wind turbines. The F&J Digital Flowmeter technology provides maximum flexibility, flow rate normalization, automatic flow control and data collection through the RS232 communication port. The typical operating flow range is 20-160 SLPM (0.7 5.65 SCFM). Actual flow range implemented will depend on the filter(s) utilized by the customer. Indoor Mode Outdoor Mode Instrument Panel
Pump Type: Centrifugal blower Maximum Flowrate: 115.8 LPM - Typical w/47 mm FP47M glass fiber media 156.5 + LPM FP-4.0M 168.5 SLPM Free Air Flow capacity Power Source: Line Power; 220VAC to 240VAC External DC Source 24VDC (option) Maximum Current Draw: 4 A maximum on line power 6 A maximum on 24 VDC Filter Holder Fitting: 3/8 FNPT quick disconnect Handle: Weight: Durable plastic 18.55 lbs. (8.41 kg) Installation Category: Pollution Degree 2 Enclosure Rating: IPX2 Average dba: 61 at 94.8 SLPM using FP-47M + TE3C Dimensions: 16.8 L 9.0 W 14.0 H (42.7 22.8 35.5 cm) Operating Temperature Range: 14 F to 104 F (-10 C to 40 C) Display: Bright LED (6 character, 1.2 cm H) Elapsed Time: DD:HH:MM up to 168 hours Flow Control: Adjustable from keypad between 20-160 LPM (Depending on filter media being used) Flow Accuracy: ±4.0% of Full Scale Factory Settable Reference T and P Classical STP 0ºC, 1 ATM Normal T and P 20ºC, 1 ATM Modified Normal T and P 70ºF, 1 ATM Standard Ambient T and P 25ºC, 1 ATM OPTIONS: Data Storage Device (P/N: 232FCDSD) 2+ GB Secure Digital Card (P/N: 372239) Flash card Reader (P/N: SDDR-199-A20) Combination Filter Holder with Rain Hood 47mm Particulate / C Geometry FJ-47RH 50mm Particulate / C Geometry FJ-50RH Battery Bank (P/N: BATBANK-24V) Standard Combination Filter Holders Available: FILTER HOLDER MODEL CHARCOAL CARTRIDGE DIMENSIONS PARTICULATE PAPER DIAME- TER FJ-05P F&J Model B 2 or 50 mm FJ-21P F&J Model C 2 or 50 mm FJ-35P F&J Model B 47 mm FJ-46P F&J Model C 47 mm FJ-51P F&J Model M 2 or 50 mm FJ-53P F&J Model M 47 mm Available Engineering Units for Flow and Volume: sccm / scc SLPM / SLP SCFM / SCF SCMH / SCM Digital Flow Meter Keypad/Display Flow / Volume: SLPM/SL 100.00
ELITE DIGITAL LIGHT (EDL) AIR SAMPLER F&J Model DF-EDL-500-AC NOTABLE FEATURES: State-of-the-Art Electronics Lightweight: 33 lbs. (15 kg) Powerful: Flow rate to 160 LPM Very low maintenance Automatic Flow Control Operator selectable Ambient or Reference flow T and P Conditions Auto shut-off on time or volume RS232 Communication port Brushless motor Optional 24 VDC input connector for external DC Power operation Optional rain shielded filter holder Line Power; 100VAC to 120VAC; 50/60 Hz Optional battery bank for situations where line power is not available GENERAL DESCRIPTION: Displayed with Optional Rain Hood and Filter Holder F&J Model DF-EDL-500-AC is a powerful portable AC/DC powered air sampling system operable from (1) line power or (2) an optional 24VDC external power source. This powerful unit is a low volume air sampler enclosed in a solid wall, strong, water tight enclosure. It has double throw latches for easy access with three comfortable rubber over-molded handles and a retractable extension handle with strong polyurethane wheels for easy transport. The DF-EDL-500-AC air sampler is well suited for various types of air sampling applications such as emergency response and work area monitoring programs. It can also be utilized in remote air sampling applications powered from solar panels or wind turbines. The F&J Digital Flowmeter technology provides maximum flexibility, flow rate normalization, automatic flow control and opportunities for data collection through the RS232 communication port. The typical operating flow range is 20-160 SLPM (0.7 5.65 SCFM). Actual flow range implemented will depend the filter(s) utilized by the customer. Indoor Mode Outdoor Mode Instrument Panel
Pump Type: Centrifugal blower Maximum Flowrate: 132.8 LPM - Typical w/47 mm FP47M glass fiber media 160.0 + LPM Free air flow capacity Power Source: Line Power; 100VAC to 120VAC External DC Source 24VDC (option) Maximum Current Draw: 4 A maximum on line power 10 A maximum on 24 VDC Filter Holder Fitting: 3/8 FNPT quick disconnect Handle: Weight: Durable rubber 33 lbs. (15 kg) Installation Category: Pollution Degree 2 Enclosure Rating: IPX2 Average db: 74.6 at 3.53 CFM using FP-47M Dimensions: 19.7 12 18 (50 30.5 46 cm) Standard Combination Filter Holders Available: FILTER HOLDER MODEL CHARCOAL CARTRIDGE DIMENSIONS PARTICULATE PAPER DIAME- TER FJ-05P F&J Model B 2 or 50 mm FJ-21P F&J Model C 2 or 50 mm FJ-35P F&J Model B 47 mm FJ-46P F&J Model C 47 mm FJ-51P F&J Model M 2 or 50 mm FJ-53P F&J Model M 47 mm Available Engineering Units for Flow and Volume: sccm / scc SLPM / SLP SCFM / SCF SCMH / SCM Digital Flow Meter Keypad/Display Operating Temperature Range: 14 F to 104 F (-10 C to 40 C) Display: Bright LED (6 character, 1.2 cm H) Elapsed Time: DD:HH:MM up to 168 hours Flow Control: Adjustable from keypad between 20-160 LPM (Depending on filter media being used) Flow Accuracy: ±4.0% of Full Scale Flow / Volume: SLPM/SL Factory Settable Reference T and P Classical STP 0ºC, 1 ATM Normal T and P 20ºC, 1 ATM Modified Normal T and P 70ºF, 1 ATM Standard Ambient T and P 25ºC, 1 ATM OPTIONS: Data Storage Device (P/N: 232FCDSD) 2+ GB Secure Digital Card (P/N: 372239) Flash card Reader (P/N: SDDR-199-A20) Combination Filter Holder with Rain Hood 47mm Particulate / C Geometry FJ-47RH 50mm Particulate / C Geometry FJ-50RH Battery Bank (P/N: BATBANK-24V) 100.00
ELITE DIGITAL LIGHT (EDL) AIR SAMPLER F&J Model DF-EDL-500E-AC NOTABLE FEATURES: State-of-the-Art Electronics Lightweight: 33 lbs. (15 kg) Powerful: Flow rate to 160 LPM Very low maintenance Automatic Flow Control Operator selectable Ambient or Reference flow T and P Conditions Auto shut-off on time or volume RS232 Communication port Brushless motor Optional 24 VDC input connector for external DC Power operation Optional rain shielded filter holder Line Power; 220VAC to 240VAC; 50/60 Hz Optional battery bank for situations where line power is not available GENERAL DESCRIPTION: Displayed with Optional Rain Hood and Filter Holder F&J Model DF-EDL-500E-AC is a powerful portable AC/DC powered air sampling system operable from (1) line power or (2) an optional 24VDC external power source. This powerful unit is a low volume air sampler enclosed in a solid wall, strong, water tight enclosure. It has double throw latches for easy access with three comfortable rubber over-molded handles and a retractable extension handle with strong polyurethane wheels for easy transport. The DF-EDL-500E-AC air sampler is well suited for various types of air sampling applications such as emergency response and work area monitoring programs. It can also be utilized in remote air sampling applications powered from solar panels or wind turbines. The F&J Digital Flowmeter technology provides maximum flexibility, flow rate normalization, automatic flow control and opportunities for data collection through the RS232 communication port. The typical operating flow range is 20-160 SLPM (0.7 5.65 SCFM). Actual flow range implemented will depend on the filter(s) utilized by the customer. Indoor Mode Outdoor Mode Instrument Panel
Pump Type: Centrifugal blower Maximum Flowrate: 132.8 LPM - Typical w/47 mm FP47M glass fiber media 160.0 + LPM Free air flow capacity Power Source: Line Power; 220VAC to 240VAC External DC Source 24VDC (option) Maximum Current Draw: 4 A maximum on line power 10 A maximum on 24 VDC Filter Holder Fitting: 3/8 FNPT quick disconnect Handle: Weight: Durable rubber 33 lbs. (15 kg) Installation Category: Pollution Degree 2 Enclosure Rating: IPX2 Average db: 74.6 at 3.53 CFM using FP-47M Dimensions: 19.7 12 18 (50 30.5 46 cm) Standard Combination Filter Holders Available: FILTER HOLDER MODEL CHARCOAL CARTRIDGE DIMENSIONS PARTICULATE PAPER DIAME- TER FJ-05P F&J Model B 2 or 50 mm FJ-21P F&J Model C 2 or 50 mm FJ-35P F&J Model B 47 mm FJ-46P F&J Model C 47 mm FJ-51P F&J Model M 2 or 50 mm FJ-53P F&J Model M 47 mm Available Engineering Units for Flow and Volume: sccm / scc SLPM / SLP SCFM / SCF SCMH / SCM Digital Flow Meter Keypad/Display Operating Temperature Range: 14 F to 104 F (-10 C to 40 C) Display: Bright LED (6 character, 1.2 cm H) Elapsed Time: DD:HH:MM up to 168 hours Flow Control: Adjustable from keypad between 20-160 LPM (Depending on filter media being used) Flow Accuracy: ±4.0% of Full Scale Flow / Volume: SLPM/SL Factory Settable Reference T and P Classical STP 0ºC, 1 ATM Normal T and P 20ºC, 1 ATM Modified Normal T and P 70ºF, 1 ATM Standard Ambient T and P 25ºC, 1 ATM OPTIONS: Data Storage Device (P/N: 232FCDSD) 2+ GB Secure Digital Card (P/N: 372239) Flash card Reader (P/N: SDDR-199-A20) Combination Filter Holder with Rain Hood 47mm Particulate / C Geometry FJ-47RH 50mm Particulate / C Geometry FJ-50RH Battery Bank (P/N: BATBANK-24V) 100.00
F&J SPECIALTY PRODUCTS, INC. The Nucleus of Quality Air Monitoring Programs PRODUCT PROFILE Air Sampling Systems High Volume Air Samplers Portable Grab Samplers Environmental Systems Enzyme Dust Samplers PM10 Systems Continuous Air Samplers Environmental Systems Portable Fixed Station Personal Air Samplers Emergency Response DC Powered Air Sampling Systems Filter Paper Glass Fiber Cellulose Membrane Quartz Filter Holders Open face In-Line PAS Filter Holders Materials Plastic Aluminum Stainless Steel Radon Detection Devices 2-Day Passive Charcoal Canisters 7-Day Passive Charcoal Canisters Continuous Radon Monitors Tritium Detection Systems Portable and Fixed Station Collection Systems utilizing Silica Gel or Molecular Sieve Absorbents Continuous Tritium Monitors New Products Global Air Sampling Systems Digital Flowmeter Air Samplers C-14 Collection Systems ELITE DIGITAL LIGHT (EDL) Air Samplers Isokinetic Air Sampling Systems MEGA High Volume Air Samplers ULTRA High Volume (CTBTO) Air Samplers Radioiodine Collection Cartridges TEDA Impregnated Charcoal Silver Zeolite Custom Cartridges Bulk Silver Zeolite Air Flow Calibrators World Calibrator Series Compact Digital V.2 Series Mini-Calibrator