BATTERY BANK POWERED AC/DC AIR SAMPLERS

Similar documents
BATTERY BANK POWERED AC/DC AIR SAMPLERS

Battery Powered Air Samplers Manufactured by F&J SPECIALTY PRODUCTS, INC.

Portable Digital Flow Meter High Volume Air Samplers

Portable Digital Flow Meter High Volume Air Samplers

F&J SPECIALTY PRODUCTS, INC.

Analog Low Volume Air Samplers

Digital High Volume Ambient Air Monitoring Systems 110 Volt

For the Health Physics, Environmental & Nuclear Industries

Power Conversion. Battery Chargers. Model

PERSONAL AIR SAMPLER & RADIATION ALARM

For the Environmental Scientist & Health Physicist

SCC-MPPT Solar Charge Controller

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

S123 v2 Fusion Splicers Hand-Held Clad Alignment Fusion Splicer

Hi Lumens & Green Energy


Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

mass flowmeter for compressed air

G2 Industrial Grade Meters

ESCORT ELF and ESCORT LC SAMPLING PUMPS

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries

FITEL S153A Ver.2 Hand-held Active Alignment Splicer

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

FLOODLIGHTS SITE LAMPS SPOTLIGHTS WORKLIGHTS HEAD LIGHTS FLASHLIGHTS

FITEL S178 Ver.2 Hand-held Core-Alignment Fusion Splicer

Solar Charge Controller

LED Cordless Sitelight

KL1.4LM (A) Main characteristic:kl1.4lm (A) LED mining lamp

Product information Panther Batterien PANTHER BATTERY ACCESSORIES.

Heavy Duty, Portable, Single & Dual Output DV Chargers: Models: Single: 12V20A Dual: 12V20A

400W / 600W / 1000W / 1500W DIY Wind Turbine

Buck BioSlide Model B1020 Instruction Manual

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

Fuel Transfer Pumps DC Aluminum Gear Fuel Pump with Auto Nozzle

c-go 24V/6A 24V/8A 24V/12A

Hour Meter Series HM36

Solar Power System. User Manual

SOLAR POWER SUPPLY SYSTEM

SCC-MPPT Solar Charge Controller

Lightweight, On-Board, Power Tender: Models: 12V6A, 24V3A

SCC-MPPT Solar Charge Controller

TRAILBLAZER LIGHTING TRAILBLAZER LIGHTING

FLOODLIGHTS SITE LAMPS SPOTLIGHTS WORKLIGHTS HEAD LIGHTS FLASHLIGHTS

A1 Commercial Grade Meters

FLOOD GATE & BARRIER

HPP1 MK5 Owner s Manual

GXSeries. User Guide DANGER

OWNERS MANUAL POWER PACK 44AH. Part No. COMPBI012. Australia s original Outdoor brand

BATTERY CHARGERS FAN COOLED HIGH FREQUENCY CHARGERS UP 30% ENERGY SAVINGS! HIGH FREQUENCY BUILT-IN CHARGER AQHF24-30FC G2 TECHNICAL PECIFICATIONS

CBHD SERIES. Single-phase battery chargers. High frequency system with advanced technology. Lightweight & compact.

Precision Control Devices

Vacuum Gauge Catalog

PROMPT TRADING CO. Ph. No.:

TP-BC AC to DC24V UNINTERRUPTED POWER SUPPLY User Manual. DC power output 8A Charge current 7.5A

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Power Inverter 400 MW Owner s Manual

Tycon RPMS Installation Instructions

HI-Q. Filter Media For Air Sampling. Filter Paper for Air Sampling. Glass Fiber, Ashless Cellulose, & Carbon Impregnated Filter Paper

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008

LASERS Positioning Tools and Accessories SLOPE LASERS UTILITY LASERS INTERIOR LASERS LASER LEVELS 2D MACHINE CONTROL ACCESSORIES

RCM - Direct Reading Flowmeters

Level Sensors and Switches Guided Radar (TDR) Radar Wave Level Sensors Ultrasonic Level Sensors Rotating Paddle Level Switches Vibrating Fork Level

Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS. Features DESCRIPTION

SBC / 2140 / Stage Battery Charger User Manual

Thermo Scientific Gilmont

mass flowmeter for compressed air

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Buck BioAire Model B520 Instruction Manual

AccuPower AQU126B Installation Instructions

OPERATING MANUAL. June 2003

CX-SERIES ADVANCED BATTERY CHARGER

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

Aquavar e-abii. TECHNICAL BROCHURE BAQUAeABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

4 submersible pumps powered by renewable energy sources

AccuPower AQU128B Installation Instructions

Power Station. by Lithium USER MANUAL

BP- A Series Switch-Mode 3 Stage Battery Charger User s Manual

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection

TECHNICAL SPECIFICATIONS

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Power Products Catalog

12V 160W Folding Portable Solar Panel Kit KDSLR160PNLA User Manual

Laboratory High Precision (0.001 g) Balances

Power Conversion. Battery Chargers. Model

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

LOW COST LIGHTING BRILLIANCE - A REVOLUTION IN SOLAR ENERGY. s o l a r s y s t e m s T H E S O L L AT E K A R E V O L U T I O N I N L I G H T I N G

THE SOLLATEK GLOWSTAR LOW COST LIGHTING BRILLIANCE - A REVOLUTION IN SOLAR ENERGY T H E S O L L AT E K A R E V O L U T I O N I N L I G H T I N G

BS20 BATTERY CHARGER For lead-acid batteries

AC CONVERTER / BATTERY CHARGER

ALSF APPROACH LIGHTING. High-Intensity Approach Lighting System WITH ELEVATED SEQUENCED FLASHERS. Operating Conditions. Compliance with Standards

TIF VA500A DIGITAL HVAC ANALYZER

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

digital flow meters BW Digi-Meter F-1000

Variable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500

Digital Insulation Resistance Testers. you can depend on

MANUAL BAT/48342 IMPORTANT NOTE : BEFORE FIRST USE CHARGE THE JUMP STARTER WITH THE SUPPLIED CHARGER FOR AT LEAST 12 HOURS.

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

Transcription:

F&J SPECIALTY PRODUCTS, INC. The Nucleus of Quality Air Monitoring Programs BATTERY BANK POWERED AC/DC AIR SAMPLERS DF-40L-400-AC DF-75L-400-AC DF-75L-AC Portable Battery Bank 12V 36Ah Battery Pack 33.6 lbs. (~15.24 kgs.) BATBANK-12V DF-AB-40L-AC DF-40L-AC DF-AB-75L-AC REV: 19 Sep. 2018

Portable 12V External Battery Bank for F&J AC/DC Air Samplers Model BATBANK-12V NOTABLE FEATURES: Internal battery charging system operable from line power input (100 240VAC, 50/60 Hz) Digital and graphical battery capacity indicator (LCD) Small dimensioned, water tight enclosure with a large rugged plastic handle for easy carry Water tight connection port for powering units outdoors GENERAL DESCRIPTION: BATBANK-12V Top View F&J model BATBANK-12V is a light one man carry 12V battery bank for use with 12 VDC powered F&J air samplers. The battery bank is approximately 36 Ah and is housed in a small foot print water tight enclosure. The BATBANK-12V can be charged by plugging it into line power (100 240VAC, 50/60Hz) and provides short circuit/reverse polarity protection. The BATBANK-12V includes an LCD display for voltage level and percent capacity of the battery bank. It is provided with a power cord for charging the system and a DC cord for connection to 12VDC powered F&J AC/DC air samplers. Frontal View of BATBANK-12V View illustrating water proof AC and DC cord connection chamber

Battery Type: Battery Charging System: Enclosure: Weight: Dimensions: Display: Sealed Lead Acid Battery 12V 36Ah Battery Pack Low Self discharge (~3% capacity/month) Internal battery charging system operable from line power (100 240VAC, 50/60Hz) Short circuit / Reverse Polarity Protector Rugged water tight plastic enclosure with a large durable handle 33.6 lbs (~15.24 kgs) 16.8 L x 9.0 W x 14.0 H (42.7 x 22.9 x 35.6 cm) Bright digital and graphical LCD battery capacity indicator Optional Rain Shield Filter Holder AC/DC Air Sampler Air Sampler Connected to a Portable Battery Bank P/N: TP-4 Battery Bank Inside View BATBANK-12V Lead Acid Batteries And Charger and Digital Battery Capacity LCD Indica- Battery Capacity Indicator View Tripod mounted and coupled to battery bank

EMERGENCY RESPONSE SAMPLING SYSTEM Digital Flowmeter Technology F&J Model DF-40L-400-AC NOTABLE FEATURES: State-of-the-Art Electronics Operating Modes Line Power (100VAC 250 VAC) Lightweight 12.25 lbs. (5.5 kg) Maximum Flow 30 to 35 LPM Maximum; typical Bright LED Display Automatic Flow Control Feature Flowrate and Volume totalizations displayed are corrected to a factory settable Reference Temperature and Pressure (4 options available) Auto shut-off on time or volume GENERAL DESCRIPTION: Displayed with Optional Rain Hood and Filter Holder F&J Model DF-40L-400-LAC is a lightweight, small footprint, DC voltage powered air sampling system operable from (1) line power, or (2) auxiliary DC connector (12 15 VDC) The automatic flow control feature with the F&J Digital Flowmeter technology provides maximum flexibility for emergency response or environmental sampling responsibilities. The set flowrate is maintained automatically in case of dust loading and does not require operator attention. The air sampler is contained in a lightweight small dimensioned enclosure which is water tight. The unit can be carried very easily by its large, rugged plastic handle. Typical flow range is 10-35 SLPM (0.3-1.24 SCFM). Outdoor use configuration Indoor use configuration Air Sampler Inside View

Pump Type: Dual diaphragm high efficiency Maximum Flowrate: 35 LPM typical with FP-47M glass fiber media Power Source: External Line Power; 100VAC to 240VAC External DC 12 15VDC Current Draw: 0.6 A maximum Filter Holder Fitting: 3/8 FNPT quick disconnect Handle: Weight: Durable plastic 12.25 lbs. (5.5 kg) Dimensions: 16.8 L 9.0 W 14.0 H (42.7 22.9 35.6 cm) Average Noise Level: 67.5 Db @ 1m Operating Temperature Range: 0ºF to 122ºF (-18ºC to 50ºC) Standard Combination Filter Holders Available: FILTER HOLDER MODEL CHARCOAL CARTRIDGE DIMENSIONS PARTICULATE PAPER DIAME- TER FJ-05P F&J Model B 2 or 50 mm FJ-21P F&J Model C 2 or 50 mm FJ-35P F&J Model B 47 mm FJ-46P F&J Model C 47 mm FJ-51P F&J Model M 2 or 50 mm FJ-53P F&J Model M 47 mm Available Engineering Units for Flow and Volume: sccm / scc SLPM / SLP SCFM / SCF SCMH / SCM Digital Flow Meter Keypad/Display Display: Bright LED (6 character, 1,2 cm H) Elapsed Time: DD:HH:MM up to 168 hours Flow Control: Adjustable from keypad between 10-35 LPM Flow Accuracy: ±4.0% of Full Scale Factory Settable Reference T and P Classical STP 0ºC, 1 ATM Normal T and P 20ºC, 1 ATM Modified Normal T and P 70ºF, 1 ATM Standard Ambient T and P 25ºC, 1 ATM Flow / Volume: SLPM/SL 28.5 OPTIONS: Data Storage Device (P/N: 232FCDSD) 2 GB Secure Digital Card (P/N: 372239) Flash card Reader (P/N: SDDR-199-A20) Combination Filter Holder with Rain Hood 47mm Particulate / C Geometry FJ-47RH 50mm Particulate / C Geometry FJ-50RH Battery Bank (P/N: BATBANK-12V)

EMERGENCY RESPONSE SAMPLING SYSTEM Digital Flowmeter Technology F&J Model DF-AB-40L-AC NOTABLE FEATURES: State-of-the-Art Electronics Operating Modes Line Power (100VAC 250VAC) Automobile Cigarette Lighter Lightweight ~13 lbs. (5,9 kg) Maximum Flow 30 to 35 LPM Maximum; typical Bright LED Display Automatic Flow Control Feature Flowrate and Volume totalizations displayed are corrected to a factory settable Reference Temperature and Pressure (4 options available) Auto shut-off on time or volume GENERAL DESCRIPTION: F&J Model DF-AB-40L-AC is a lightweight, small footprint, DC voltage powered air sampling system operable from (1) line power, or (2) a 12-15 VDC power source such as solar panels or other alternative energy sources. The DF-AB-40L-AC is well suited for alternative energy air sampling activities where users do not know whether line power will be available. The unit may be operated from solar power or wind power source through either the AC input or DC input. The automatic flow control feature with the F&J Digital Flowmeter technology provides maximum flexibility for emergency response sampling responsibilities. The set flowrate is maintained automatically in case of dust loading and does not require operator attention. The air sampler is contained in a lightweight small dimensioned enclosure which is water tight. The unit can be carried very easily by its large, rugged plastic handle. Typical flow range is 10-35 SLPM (0.3-1.24 SCFM). View of Inside Air Sampler on window bracket Connection to vehicle cigarette lighter for 12VDCor sampling applications

Pump Type: Dual diaphragm high efficiency Maximum Flowrate: 35 LPM typical with 47 mm glass fiber media (98% DOP efficiency) Power Source: Line Power; 100VAC or 250VAC Vehicle Cigarette Lighter 12VDC Current Draw: 0.6 A maximum Filter Holder Fitting: 3/8 FNPT quick disconnect Handle: Weight: Durable plastic 13 lbs. (5,9 kg) Dimensions: 14.5 L 8 W 10 H (36,8 20,3 25 4 cm) Operating Temperature Range: 0ºF to 122ºF (-18ºC to 50ºC) Standard Combination Filter Holders Available: FILTER HOLDER MODEL CHARCOAL CARTRIDGE DIMENSIONS PARTICULATE PAPER DIAMETER FJ-05P F&J Model B 2 or 50 mm FJ-21P F&J Model C 2 or 50 mm FJ-35P F&J Model B 47 mm FJ-46P F&J Model C 47 mm FJ-51P F&J Model M 2 or 50 mm FJ-53P F&J Model M 47 mm Available Engineering Units for Flow and Volume: sccm / scc SLPM / SLP SCFM / SCF SCMH / SCM Digital Flowmeter Keypad/Display Display: Bright LED (6 character, 1,2 cm H) Elapsed Time: DD:HH:MM up to 168 hours Flow Control: Adjustable from keypad between 10-35 LPM Flow Accuracy: ±4.0% of Full Scale Factory Settable Reference T and P Classical STP 0ºC, 1 ATM Normal T and P 20ºC, 1 ATM Modified Normal T and P 70ºF, 1 ATM Standard Ambient T and P 25ºC, 1 ATM OPTIONS: Data Storage Device (P/N: 232FCDSD) 2 GB Secure Digital Card (P/N: 372239) Flash card Reader (P/N: SDDR-199-A20) Flow / Volume: SLPM/SL 28.5

EMERGENCY RESPONSE SAMPLING SYSTEM AC or DC POWERED AIR SAMPLER Digital Flowmeter Technology F&J Model DF-40L-AC NOTABLE FEATURES: State-of-the-Art Electronics Operating Modes Line Power (100VAC 250VAC) 12VDC External Source Lightweight ~10 lbs. (4.5 kg) Maximum Flow 30 to 35 LPM Maximum; typical Bright LED Display Automatic Flow Control Feature Flowrate and Volume totalizations displayed are corrected to a factory settable reference Temperature and Pressure (4 options available). Auto shut-off on time or volume GENERAL DESCRIPTION: F&J Model DF-40L-AC is a lightweight, small footprint, DC voltage powered air sampling system operable from (1) line power, or, (2) an external 12VDC source such as solar panels. The DF-40L-AC is well suited for remote area air sampling activities where users do not have line power available. The automatic flow control feature with the F&J Digital Flowmeter technology provides maximum flexibility for emergency response sampling responsibilities. The set flowrate is maintained automatically in case of dust loading and does not require operator attention. Typical flow range is 10-35 SLPM (0.3-1.2 SCFM).

Pump Type: Dual diaphragm high efficiency Maximum Flowrate: Typical 35 LPM with 47 mm glass fiber media (98%DOP efficiency) Power Source: External Line Power; 100VAC or 230VAC Automobile Cigarette Lighter 12VDC Current Draw: Filter Holder Fitting: 3/8 FNPT quick disconnect Handle: Weight: Durable metal ~10 lbs. (4.5 kg) Dimensions: 8 6 8 0.6 A maximum (20 15 20 cm) Operating Temperature: 0ºF to 122ºF (-18ºC to 50ºC) Standard Combination Filter Holders Available: FILTER HOLDER MODEL CHARCOAL CARTRIDGE DIMENSIONS PARTICU- LATE PAPER DIAMETER FJ-05P F&J Model B 2 or 50 mm FJ-21P F&J Model C 2 or 50 mm FJ-35P F&J Model B 47 mm FJ-46P F&J Model C 47 mm FJ-51P F&J Model M 2 or 50 mm FJ-53P F&J Model M 47 mm Available Engineering Units for Flow and Volume: sccm / scc SLPM / SLP SCFM / SCF Digital Flowmeter Keypad/Display Decibels: 67 (average) Display: Bright LED (6 character, 1,2 cm H) Elapsed Time: DD:HH:MM up to 168 hours Flow Control: Adjustable from keypad between 10-35 LPM Flow Accuracy: ±4.0% of Full Scale Flow / Volume: SLPM/SL Factory Settable Reference T and P Classical STP 0ºC, 1 ATM Normal T and P 20ºC, 1 ATM Modified Normal T and P 70ºF, 1 ATM Standard Ambient T and P 25ºC, 1 ATM 28.5 OPTIONS: Data Storage Device (P/N: 232FCDSD) 2 GB Secure Digital Card (P/N: 372239) Flash card Reader (P/N: SDDR-199-A20)

EMERGENCY RESPONSE SAMPLING SYSTEM Digital Flowmeter Technology F&J Model DF-75L-400-AC NOTABLE FEATURES: State-of-the-Art Electronics Operating Modes Line Power (100VAC 250 VAC) Lightweight 16.75 lbs. (7.59 kg) Maximum Flow 15 to 75 LPM Maximum; typical Bright LED Display Automatic Flow Control Feature Flowrate and Volume totalizations displayed are corrected to a factory settable Reference Temperature and Pressure (4 options available) Auto shut-off on time or volume Optional battery bank for situations where line power is not available Displayed with Optional Rain Hood and Filter Holder GENERAL DESCRIPTION: F&J Model DF-75L-400-AC is a lightweight, small footprint, DC voltage powered air sampling system operable from (1) line power, or (2) auxiliary DC connector (12 15 VDC) This air sampler can be utilized with the optional rain shield filter holder system for use when rain or snow conditions exist. The automatic flow control feature with the F&J Digital Flowmeter technology provides maximum flexibility for emergency response or environmental sampling responsibilities. The set flowrate is maintained automatically in case of dust loading and does not require operator attention. The air sampler is contained in a lightweight small dimensioned enclosure which is water tight. The unit can be carried very easily by its large, rugged plastic handle. Typical flow range is 15-75 SLPM (0.5 2.6 SCFM). Outdoor use configuration Indoor use configuration Air Sampler Inside View

Pump Type: Dual diaphragm high efficiency Maximum Flowrate: 75 LPM typical with FP-47M glass fiber media Power Source: External Line Power; 100VAC to 240VAC External DC 12-15VDC Current Draw: 3 A maximum Filter Holder Fitting: 3/8 FNPT quick disconnect Handle: Weight: Durable plastic 16.75 lbs. (7.59 kg) Dimensions: 16.8 L 9.0 W 14.0 H (42.7 22.9 35.6 cm) Standard Combination Filter Holders Available: FILTER HOLDER MODEL CHARCOAL CARTRIDGE DIMENSIONS PARTICULATE PAPER DIAME- TER FJ-05P F&J Model B 2 or 50 mm FJ-21P F&J Model C 2 or 50 mm FJ-35P F&J Model B 47 mm FJ-46P F&J Model C 47 mm FJ-51P F&J Model M 2 or 50 mm FJ-53P F&J Model M 47 mm Available Engineering Units for Flow and Volume: sccm / scc SLPM / SLP SCFM / SCF Average Noise Level: 70.3 Db @ 1m Digital Flow Meter Keypad/Display Operating Temperature Range: 0ºF to 122ºF (-18ºC to 50ºC) Display: Bright LED (6 character, 1,2 cm H) Elapsed Time: DD:HH:MM up to 168 hours Flow Control: Adjustable from keypad between 15-75 LPM Flow Accuracy: ±4.0% of Full Scale Factory Settable Reference T and P Classical STP 0ºC, 1 ATM Normal T and P 20ºC, 1 ATM Modified Normal T and P 70ºF, 1 ATM Standard Ambient T and P 25ºC, 1 ATM Flow / Volume: SLPM/SL 28.5 OPTIONS: Data Storage Device (P/N: 232FCDSD) 2 GB Secure Digital Card (P/N: 372239) Flash card Reader (P/N: SDDR-199-A20) Combination Filter Holder with Rain Hood 47mm Particulate / C Geometry FJ-47RH 50mm Particulate / C Geometry FJ-50RH Battery Bank (P/N: BATBANK-12V)

EMERGENCY RESPONSE SAMPLING SYSTEM Digital Flowmeter Technology F&J Model DF-AB-75L-AC NOTABLE FEATURES: State-of-the-Art Electronics Operating Modes Line Power (100VAC 250VAC) Automobile Cigarette Lighter Lightweight ~17.25 lbs. (8.1 kg) Maximum Flow 75 LPM Maximum; typical Bright LED Display Automatic Flow Control Feature Flowrate and Volume totalizations displayed are corrected to a factory settable Reference Temperature and Pressure (4 choices) Auto shut-off on time or volume GENERAL DESCRIPTION: F&J Model DF-AB-75L-AC is a lightweight, small footprint, DC voltage powered air sampling system operable from (1) line power or (2) a 12-15 VDC power source such as solar panels or other alternative energy sources. The DF-AB-75L-AC is well suited for alternative energy air sampling activities where users do not know whether line power will be available. The unit may be operated from solar power or wind power source through either the AC input (via inverter) or DC input. The automatic flow control feature with the F&J Digital Flowmeter technology provides maximum flexibility for emergency response sampling responsibilities. The set flowrate is maintained automatically in case of dust loading and does not require operator attention. The air sampler is contained in a lightweight enclosure which is water tight. The unit can be carried very easily by its large, rugged plastic handle. Typical flow range is 30-75 SLPM (2.6 SCFM).

Pump Type: Dual diaphragm high efficiency Maximum Flowrate: 75 LPM typical with FP47M glass fiber media Power Source: Line Power; 100VAC or 250VAC Vehicle Cigarette Lighter 12 VDC External Battery 12 to 15 VDC Current Draw: ~3 A @ 75 LPM Filter Holder Fitting: 3/8 FNPT quick disconnect Standard Combination Filter Holders Available: FILTER CHARCOAL PARTICULATE HOLDER CARTRIDGE DI- PAPER DIAME- MODEL MENSIONS TER FJ-05P F&J Model B 2 or 50 mm FJ-21P F&J Model C 2 or 50 mm FJ-35P F&J Model B 47 mm FJ-46P F&J Model C 47 mm FJ-51P F&J Model M 2 or 50 mm FJ-53P F&J Model M 47 mm Handle: Weight: Durable plastic 31 lbs. (14 kg) with battery 17.25 lbs. (8.1 kg) without battery Available Engineering Units for Flow and Volume: SLPM / SLP SCFM / SCF Dimensions: 17 L 10.4 W 13 H (43,2 26,4 33 cm) Digital Flowmeter Keypad/Display Operating Temperature Ranges: 14ºF to 122ºF (-10ºC to 50ºC) Display: Bright LED (6 character, 1,2 cm H) Elapsed Time: DD:HH:MM up to 168 hours Flow Control: Adjustable from keypad between 30-75 LPM Flow Accuracy: ±4.0% of Full Scale Factory Settable Reference T and P Classical STP 0ºC, 1 ATM Normal T and P 20ºC, 1 ATM Modified Normal T and P 70ºF, 1 ATM Standard Ambient T and P 25ºC, 1 ATM Flow / Volume: SLPM/SL 60.0 OPTIONS: Data Storage Device (P/N: 232FCDSD) 2 GB Secure Digital Card (P/N: 372239) Flash card Reader (P/N: SDDR-199-A20)

EMERGENCY RESPONSE SAMPLING SYSTEM 12VDC POWERED AIR SAMPLER Digital Flowmeter Technology F&J Model DF-75L-AC NOTABLE FEATURES: State-of-the-Art Electronics Operating Modes Line Power (100VAC 250VAC) Automobile Cigarette Lighter Lightweight 19 lbs. (8.6 kg) Maximum Flow: 65 to 75 LPM; typical Bright LED Display Automatic Flow Control Feature Flowrate and Volume totalizations displayed are corrected to a factory settable Reference Temperature and Pressure (4 options available) Auto shut-off on time or volume GENERAL DESCRIPTION: F&J Model DF-75L-AC is a lightweight, small footprint, AC powered air sampling system operable from (1) line power, (2) line power, or (3) automobile cigarette lighter socket.. The DF-75L-AC is well suited for emergency response sampling activities where users do not know whether line power will be available. Typical operating time from on-board battery is approximately 8-10 hours utilizing 47 mm glass fiber filter paper. The automatic flow control feature with the F&J Digital Flowmeter technology provides maximum flexibility for emergency response sampling responsibilities. The set flowrate is maintained automatically in case of dust loading and does not require operator attention. Typical flow range is 30-75 SLPM (1.1-2.6 SCFM).

Pump Type: Dual diaphragm high efficiency Maximum Flowrate: 75 LPM Typical w/47 mm FP47M glass fiber media Power Source: Line Power; 100VAC or 250VAC Automobile Cigarette Lighter 12VDC Current Draw: 4 A maximum Filter Holder Fitting: 3/8 FNPT quick disconnect Handle: Weight: Durable metal 19 lbs. (8.6 kg) Dimensions: 15 16 13 Operating Temperature Ranges: 0ºF to 122ºF (-18ºC to 50ºC) (38.1 28 33 cm) Standard Combination Filter Holders Available: FILTER HOLDER MODEL CHARCOAL CARTRIDGE DI- MENSIONS PARTICULATE PAPER DIAME- TER FJ-05P F&J Model B 2 or 50 mm FJ-21P F&J Model C 2 or 50 mm FJ-35P F&J Model B 47 mm FJ-46P F&J Model C 47 mm FJ-51P F&J Model M 2 or 50 mm FJ-53P F&J Model M 47 mm Available Engineering Units for Flow and Volume: sccm/ scc SLPM / SLP SCFM / SCF SCMH / SCM Digital Flowmeter Keypad/Display Display: Bright LED (6 character; 1.2 cm H) Elapsed Time: DD:HH:MM up to 168 hours Flow Control: Adjustable from keypad between 30-75 LPM Flow Accuracy: ± 4.0% of Full Scale Factory Settable Reference T and P Classical STP 0ºC, 1 ATM Normal T and P 20ºC, 1 ATM Modified Normal T and P 70ºF, 1 ATM Standard Ambient T and P 25ºC, 1 ATM OPTIONS: Data Storage Device (P/N: 232FCDSD) 2 GB Secure Digital Card (P/N: 372239) Flash card Reader (P/N: SDDR-199-A20) Flow /Volume: SLPM/SL 60.0

F&J SPECIALTY PRODUCTS, INC. The Nucleus of Quality Air Monitoring Programs PRODUCT PROFILE Air Sampling Systems High Volume Air Samplers Portable Grab Samplers Environmental Systems Enzyme Dust Samplers PM10 Systems Continuous Air Samplers Environmental Systems Portable Fixed Station Personal Air Samplers Emergency Response DC Powered Air Sampling Systems Filter Paper Glass Fiber Cellulose Membrane Quartz Filter Holders Open face In-Line PAS Filter Holders Materials Plastic Aluminum Stainless Steel Radon Detection Devices 2-Day Passive Charcoal Canisters 7-Day Passive Charcoal Canisters Continuous Radon Monitors Tritium Detection Systems Portable and Fixed Station Collection Systems utilizing Silica Gel or Molecular Sieve Absorbents Continuous Tritium Monitors New Products Global Air Sampling Systems Digital Flowmeter Air Samplers C-14 Collection Systems ELITE DIGITAL LIGHT (EDL) Air Samplers Isokinetic Air Sampling Systems MEGA High Volume Air Samplers ULTRA High Volume (CTBTO) Air Samplers Radioiodine Collection Cartridges TEDA Impregnated Charcoal Silver Zeolite Custom Cartridges Bulk Silver Zeolite Air Flow Calibrators World Calibrator Series Compact Digital V.2 Series Mini-Calibrator