Power/oor Switch oor Interlock Power Switch with Minimum Contact gap of mm Offers the minimum contact gap of mm required for power switches as standard equipment. Safety considerations include a double return spring and direct drive positive contact opening feature. Pullon lock model for easy maintenance is also available. RoHS Compliant Number Legend Contact Form @@0 1 @ 1. Construction 1: Single pole, contact gap mm : Pullon lock, contact gap 1 mm : ouble pole, contact gap mm SPST+SPST 1000 000 1100 100 SPST 1001 1101 SPST 100 110 List of s Mounting Screw mounting Panel mounting. Mounting 0: Screw mounting 1: Panel mounting. Contact 0: SPST+SPST 1: SPST : SPST : PST+SPST 4: PST Type Standard Pullon lock * Contact gap Contact form mm min. 1 mm SPST+SPST 1000 000 SPST 1001 SPST 100 SPST+SPST 1100 100 SPST 1101 SPST 110 PST+SPST 10 PST 104 * Refer to next page for the pullon lock function. PST+SPST 10 Contact Specifications Item Type Standard Pullon lock Contact Inrush current * Please refer to " Using Micro Loads" in " Precautions" for more information on the minimum applicable load. Ratings Specification Material Rivet Silver Gap (standard value) mm min. 1 mm max. 4 max. max. 4 max. Minimum applicable load (reference value) * PST 104 5 VC 160m Item Type Rated voltage Resistive load Standard 50 VC 16 Pullon lock model 50 VC 10 Note. The above rating values apply under the following test conditions. (1) mbient temperature: 0± C () mbient humidity: 65±5% () Operating frequency: operations/min Terminal Connection Parts (Sold Separately) Refer to "Basic Switch Common ccessories" 1
Power/oor Switch Characteristics Item 1000 models 000 models 00 models Permissible operating speed 10 mm to 1 m/s Permissible Mechanical 0 operations/min operating frequency Electrical 60 operations/min Insulation resistance Note. The data given above are initial values. * For testing conditions, consult your OMR sales representative. 100 MΩ min. (at 500 VC with insulation tester) Contact resistance (initial value) 50 mω max. Between terminals of the same polarity,000 VC 50/60 Hz 1min 1,000 VC 50/60 Hz 1min,000 VC 50/60 Hz 1min ielectric strength Between currentcarrying metal parts and ground Between each terminal and noncurrentcarrying metal parts,000 VC 50/60 Hz 1min 1,500 VC 50/60 Hz 1min,000 VC 50/60 Hz 1min,500 VC 50/60 Hz 1min 1,500 VC 50/60 Hz 1min Between terminals and actuator 4,000 VC 50/60 Hz 1min 4,000 VC 50/60 Hz 1min Vibration resistance Malfunction 10 to 55 Hz, 1.5 mm double amplitude Shock urability 1,000 m/s {approx. 100G} max. resistance Malfunction 500 m/s {approx. 50G} max. 0 m/s {approx. G} max. 500 m/s {approx. 50G} max. urability * Mechanical 10,000,000 operations min. (60 operations/min) Electrical 100,000 operations min. ( operations/min) egree of protection IEC IP40 egree of protection against electric shock Class II Proof tracking index (PTI) 175 mbient operating temperature mbient operating humidity Weight 5 C to +85 C (at ambient humidity 60 % max.) (with no icing or condensation) 85% max. (for +5 C to +5 C) pprox. 14 g (for 1000) Pullon lock function (000 models) When opening or closing the door, the power state of the Switch can be checked with the door left open when applying normal (momentary) operations. By closing the door after maintenance inspection, the Switch will resume the normal momentary operation. (This feature is ideal for conducting the electrical continuity test, inspection, repair, etc. on the Switch after its assembly.) Example To turn the power when the door is closed State Contact irect Contact Opening Mechanism (1000 models) Pushing the plunger will effectively break the circuit on the side even if a contact weld occurs in the Switch. irect Contact Opening Mechanism is not available in connection. pproved Safety Standard UL (UL1054) /CS (CS C. No.55) Rated voltage 1000 000 00 15 VC 50 VC VE (EN610581) 16 10 /4HP 16 11/HP Rated voltage 1000 000 00 50 VC 16 (4) 10 16 (4) Test conditions: 1E4 (10,000 operations) T85 (0 C to 85 C) Note. The values in parentheses are the motor load ratings. To turn the power when the door is open Mounting Holes (Unit: mm) Screw Mounting Hole imensions Panel Cutout imensions 4. dia. mounting holes or M4 screw hole Four, 1.R max. To turn the power with the door left open Pull ±0.1.5±0.1 t ouble Spring Mechanism (1000/00 models) t=1.0 : =6.7±0.1 t=.5 : =7.0±0.1 Two return springs are provided for the pin plunger. Thus, if either of the springs is broken, this feature will prevent the Switch from malfunctioning or shortcircuiting.
imensions (Unit: mm) /Operating Characteristics Power/oor Switch Standard model Screw Mounting 1000 1001 100 0558RN ±0.1 16 OP TTP 1.8 5. 4.±0.05 dia. 5.8.6 4Quick Connect Terminal (#50) 1.4.6 Operating Force OF Max. () () 1000.94 N 1001 100.94 N Overtravel OT Min.. mm. mm 5.5 mm 16.4 mm 17 mm 16.4 mm Operating Position OP () () 15.9±0.4 mm 1.7±0.4 mm 1.7±0.4 mm 15.9±0.4 mm 10 mm 10 mm 10 mm 1100 1101 110 OP TTP 40±0.1 1. 5..0 1.7 4Quick Connect Terminal (#50) 1.4 1.8 Operating Force OF Max. () () 1100.94 N 1101 110.94 N Overtravel OT Min.. mm. mm 5.5 mm 1.4 mm mm 1.4 mm Operating Position OP () () 11.9±0.4 mm 8.7±0.4 mm 8.7±0.4 mm 11.9±0.4 mm 6 mm 6 mm 6 mm 10 40±0.4 5.6 dia. 1.±0. OP TTP 1858RN 1 41.5 104 OP TTP 8.8.8 1.6 4.4 40±0.4 6Quick Connect Terminal (#50) 5.6 dia. 1.±0. Operating Force OF Max. () () 10.94 N 9.81 N {1,000 gf} 104 9.81 N {1,000 gf} Overtravel OT Min.. mm. mm 1.4 mm.5 mm Operating Position OP * () 11.9±0.8 mm () 8.7±0.8 mm 8.7±0.8 mm 6.4 mm 6.4 mm * Operating sequence of the two circuits are not specified. 1 41.5 8.8 1.6 4.4 4Quick Connect Terminal (#50) Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions..the operating characteristics are for operation in the direction ( ).
Power/oor Switch Pullon lock model Screw Mounting 000 948RN *TTP *OP OP TTP ±0.1 16 5. 4.±0.05 dia. 1.8 5.8.6 4Quick Connect Terminal (#50) 1.4.6 * In Pullon lock operation Momentary Operation (Normal Operation) Operating Force OF Max. () () 000 1.96 N {00 gf}.94 N 100 1.96 N {00 gf}.94 N Overtravel OT Min. 4.5 mm 4.5 mm 14. mm 10. mm Operating Position OP () ().5±0.6 mm 1.7±0.6 mm 9.5±0.6 mm 8.7±0.6 mm 8. mm 4. mm 100 *TTP *OP OP TTP 40±0.1.0 1.7 1. 1.8 Pullon lock Operation Operating Force OF Max. Pretravel PT Max. Overtravel OT Min. Movement ifferential M Max. Operating Position OP 000 19.61 N {,000 gf} mm 0.4 mm 1.5 mm 14. mm 15.1±0.6 mm 16.5 mm 100 19.61 N {,000 gf} mm 0.4 mm 1.5 mm 10. mm 11.1±0.6 mm 1.5 mm 5. 4Quick Connect 1.4 Terminal (#50) * In Pullon lock operation Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions..the operating characteristics are for operation in the direction ( ). Precautions Please refer to "Basic Switches Common Precautions" for correct use. Using Micro Loads Correct Use Using a model for ordinary loads to open or close the contact of Mounting a micro load circuit may result in faulty contact. It is pply operation force to the pin plunger in the direction it recommended to use the Switch in the operation range shown operates. pplying forces laterally or from an oblique direction below. The minimum applicable load is the Nlevel reference may damage the pin plunger. value. This value indicates the malfunction reference level for the reliability level of 60% (λ60). (JIS C500) The equation, λ60=0.5 10 6 /operations, indicates that the 1 estimated malfunction rate is less than operations,000,000 with a reliability level of 60%. Use M4 mounting screw with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque of 0.49 to 0.69 N m {5 to 7 kg cm}. Voltage (V) 4 6 m Wiring It is recommended to use sleeve receptacles when connecting with the quick connect terminals. Insert the receptacle straight toward the terminal. pplying excessive external force horizontally or vertically may cause deformation of terminals and may damage the housings. 1 5 0 0.1 Operating range 160 m 1 10 100 1,000 Current (m) 4
Power/oor Switch pplication examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMR representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: o not use this document to operate the Unit. OMR Corporation ELECTRIC N MECHNICL COMPENTS COMPNY Contact: www.omron.com/ecb Cat. No. B085E108 0117(007)(O) 5