LA Motor Protection. A South African Company to be Proud of

Similar documents
Series Motor Protection

KD LV Motor Protection Relay

320 to 327 M Series Low and Medium Voltage Motor Protection Relays

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

GA PLUS Ordering Information. Earth Leakage Motor Protection Relay Kits

M440 MOTOR PROTECTION, EARTH FAULT LOCKOUT & MANAGEMENT RELAY VERSION 3.5 NINGI SERVICES (PTY) LTD

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

XM1 - Motor protection relay

SALES PRESENTATION FOR RELAYS, CONTACTORS & MOTOR STARTER TESTING EQUIPMENTS

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

ADDITIONAL INFORMATION. BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY and RETROFIT KITS. FEATURES and APPLICATION Page 2

RVS-DX Digital Reduced Voltage Motor Starter

A21M. Introduction: Functional Overview: Key Protection & Control Functions:

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

Synergy EN product information

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

RVS-DN Digital Reduced Voltage Motor Starter

Submittal Data Information

MAGNETIC MOTOR STARTERS

SECTION MOTOR CONTROL

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Components for EEx e Panels

Softstarter Intelligent Controllers

DIGITAL EARTH LEAKAGE RELAY

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

SURE-TRIP OEM RELACEMENT TRIP UNIT

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Thermal overload relays Type TA Class 10

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

SURE TRIP RETRO KITS

Application Description

Moulded case circuit breakers

Multi-purpose percentage restraint differential protection

Technical Information

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

Breaker failure relay REB 010

Bulletin 825 SMM Smart Motor Manager

Installation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue

Thermal Overload Relays

MCD 200 Series Soft Starters

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering

TO COME. CEP7 Solid-State Overload Relay for Motor Control Centers and Enclosed Control

Bimetal Overload Relays 3UA and 3UC

CSP Circuit Breaker Three Phase

Reverse power relay and protection assemblies

Power Switching Devices

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Medium Voltage Soft Starters MOTOR CONTROL IS OUR NATURE

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE

LR9 F OVERLOAD RELAYS

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

SD Series Non-Fused Load Switches

ACS motor protection circuit breakers KT 7 Introduction

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

CI-TI Contactors and Motor Starters Type CI 6-50

B BASIC HEAT TREATMENT CONSOLE

From the dawn of Excellence emanates the high noon of Performance.

SIRIUS 3RU2 Thermal Overload Relays

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

Installation Manual for DC Injection Brake Units

Technical Data Accessories MCBs Ex9B.

IEC Contactors & Starters. (IT.) Electro-Mechanical

Transformers Global product offering

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

THYRISTORS T2-2PH from 45A to 2700A Specifications Universal 2 Phase Thyristor Unit , March 2012

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Protection and control VIP30, VIP35. Relays technical manual

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

Transfer switch GTEC open or delayed transition

Ktec Contactors and thermal overloads

Product Line Overview. The Most Logically Designed Contact Assembly

DPX moulded case circuit breakers

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

DEEP SEA ELECTRONICS PLC

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

W-SLC Medium Voltage fused contactor truck A safe, reliable and efficient motor starter

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications:

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

EPS-ECONOMY PUMP STARTER

Motor Protection With The MonitorPro

Designed for ease of integration with automation systems

Transcription:

LA Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za

About NewElec NewElec designs and manufactures a wide range of superior electronic motor protection relays for both local and International markets. NewElec's goal, for the past 38 years, has been to exceed the expectations of every client by OFFERING quality products, outstanding customer service and greater value, thus optimizing system functionality and improved operational efficiency. As experts in motor protection, NewElec is involved in every stage of the client's selection of the required protection relay offering ongoing functional and technical support. Our R&D division is continually designing the most up to date motor protection products to meet customer requirements. NewElec's electronic motor protection relays can be found in refineries, mining, steel, petrochemical, pulp and paper, sugar mills, agriculture and material handling industries to name a few, both locally and internationally. The NewElec product range includes software programmable LV motor protection relays for process control applications, protection relays for LV and MV motors, relays for pump motor protection, as well as earth leakage protection relays. NewElec is continually expanding and has recently installed a manufacturing division for its relay housings. This ensures that the final product meets NewElec's precise requirements. With headquarters in Pretoria West, Gauteng, South Africa, NewElec was established in May 1978 and is accredited with ISO 9002.

Why was it designed? To provide superior thermal and unbalance current protection in applications that would traditionally have used thermal bimetal relays. This microprocessor based thermal overload relay designed to IEC 60255-8 provides: Overload protection for cyclic and stable loads Unbalance current and single-phasing protection A single feed through primary 22 mm aperture covers the range 1 to 250 amps

Feature Highlights Overload protection cyclic and sustained thermal curve Class 15 Cold 5 Hot Thermal memory as per IEC 60255-8 Thermal memory decay caters for running and standstill conditions Locked rotor protection Unbalance current single phasing protection (20%) Stable operation with VSD and soft starters Fail-safe trip relay configuration indicates relay healthy Latched LED trip diagnosis Test main trip relay - toggle 1sec pulse when motor is at standstill

Benefits Accurate overload protection during any phase of operation Unbalance current protection Phase loss single-phasing protection Descriptive fault / level monitoring indication LEDs User-friendly calibration settings Requires no additional CTs for load currents 1 to 250 amps Current range from 1 to 250 amps in 4 models

Typical Applications Pump motors Thermal motor protection within Class 5 Hot curve Compressor motors with cyclic loading

Specifications Input Current From NewElec Current Transformer Module Block Overload Curve Accuracy ± 5% : 1,2 to 10 (le) ± 7% : 1 to 1,2 (le) Maximum Load Current Setting Level Setting Accuracy : ± 2% Repeatability : ± 1% Detection Level : 102% of (le) Operational Level : 104% of (le) Calibration : Amps R.M.S. Setting Range : 10% to 100% In Response : Average Value

Specifications Contd. Overload Withstand Ratings LA 10 LA 50 LA 100 LA 250 : 50 Amp cont. : 100 Amp cont. : 200 Amp cont. : 500 Amp cont. Environmental Withstand Insulation : IEC 255-5 / A Impulse Voltage : IEC 255-5 / Class 3 Auxiliary Supply Range : 110V or 220V AC Operating Range : 85% to 120% Burden : 3VA Frequency Range : 45 to 65Hz Isolation : 2kV 1 minute IEC 255-5 / A Impulse Withstand : Transient 5kV IEC 255-5 / Class 3

Specifications Contd. Overload Reset Delay Running Standing Unbalanced Current : 1 X t heating : 2 X t heating Setting (I2) : 20% (ILOAD) Calibration : Amps Detection Level : 102% (I2) Repeatability : ± 2% Trip Delay : 4 seconds Delay Accuracy : ± 0,05 seconds Contact Ratings Main Trip Relay : 5 Amps 220V AC Configuration : 1 n/o + 1 n/c Terminals : n/c 14 and 15 : n/c 16 and 17 Isolation : 2kV separate circuits : 1kV across contacts Interference High Frequency : IEC 255-22-1 Electromagnetic : IEC 255-22-3

Electrical Connection Diagram

Innovative solutions from South Africa s Leading Motor Protection Specialists Dimensional Diagram

Ordering Information MODEL LA 10 LA 50 LA 100 LA 250 AMPERAGE RANGE 1 to 10 Amp 5 to 50 Amp 10 to 100 Amp 25 to 250 Amp

We provide a 1 year renewable guarantee We repair products out of guarantee for 50% of their list price and renew the guarantee Local support

Applications particularly well suited for use in conjunction with the NewElec range of electronic motor protection relays. Mining Water Affairs Petro Chemical Refineries Agriculture Material Handling Mills Cable Theft Detection Pulp & Paper