Series Motor Protection

Similar documents
LA Motor Protection. A South African Company to be Proud of

KD LV Motor Protection Relay

320 to 327 M Series Low and Medium Voltage Motor Protection Relays

GA PLUS Ordering Information. Earth Leakage Motor Protection Relay Kits

M440 MOTOR PROTECTION, EARTH FAULT LOCKOUT & MANAGEMENT RELAY VERSION 3.5 NINGI SERVICES (PTY) LTD

Designed for ease of integration with automation systems

RVS-DN Digital Reduced Voltage Motor Starter

ABB Softstarter Benefits Charnchanok Thongprad

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

XM1 - Motor protection relay

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

TDX - Taco Duplex Starter with

Micro Controller based Motor Protection Relay & Motor Management System

Submittal Data Information

Features and Benefits. Control Features

SALES PRESENTATION FOR RELAYS, CONTACTORS & MOTOR STARTER TESTING EQUIPMENTS

From the dawn of Excellence emanates the high noon of Performance.

TO COME. CEP7 Solid-State Overload Relay for Motor Control Centers and Enclosed Control

A21M. Introduction: Functional Overview: Key Protection & Control Functions:

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

RVS-DX Digital Reduced Voltage Motor Starter

MSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control

MAGNETIC MOTOR STARTERS

DEEP SEA ELECTRONICS PLC

CTi Automation - Phone: Fax: Web:

Application Engineering

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT

Application Description

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

From the dawn of Excellence emanates the high noon of Performance.

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Contactors and Overloads MC

Open Chassis Star-Delta Starter User Guide

DEEP SEA ELECTRONICS PLC

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

SECTION MOTOR CONTROL

Installation Manual for DC Injection Brake Units

Phone: Fax: Web: -

Application Engineering

PSE The efficient range Description

Type SOQ Negative Sequence Time Overcurrent Relay

825-P Modular Protection System for motors Specification Guide

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

RIDE THROUGH TECHNOLOGY

LR9 F OVERLOAD RELAYS

B CW POWER RELAY

B BASIC HEAT TREATMENT CONSOLE

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE

MCD 500 Operating Instruction. Safety 5 Warnings 5. Feature List 7 Type Code 8. Mechanical Installation 9 Dimensions and Weights 10

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents

SURE-TRIP OEM RELACEMENT TRIP UNIT

AIR COOLED RECTIFIER SPECIFICATION S-50-A

Electromagnetic Industries LLP

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

USERS MANUAL MCD REMOTE OPERATOR

MAIN ELECTRIC MOTOR 900 HP 4000 V 60 HZ MAKE: RELIANCE ELECTRIC

Bulletin 825 SMM Smart Motor Manager

EE042: Practical Power System Protection for Engineers & Technicians

Crompton Controls. This is. Installation and Maintenance Instructions. S10 & Smooth-BRAKE DC Injection Brake Modules. Tel: +44 (0)

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

MaxPak Plus Analog DC V S Drive

Product Description. Application Description

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

SDS Enclosed Star-Delta Starter User Guide

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

3 Phase Smart Controller

ampcontrol s Hard rock relay range

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications


LARSEN & TOUBRO LIMITED TYPICAL SCHEME FOR PROTECTION OF SYNCHRONOUS MOTORS

High Performance, High Function System Drive SOFTSTARTER SS7. 2.2kW ~ 1.5MW / 230 ~ 690V. Drive Solution

SURE TRIP RETRO KITS

INTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS

Question Number: 1. (a)

Application Engineering Europe

Submittal Data Information

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Protection and control VIP30, VIP35. Relays technical manual

Part # Features & Applications Specifications Cross Reference

Components for EEx e Panels

Installation, Operation and Maintenance Manual

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

Installation, Operation and Maintenance Manual

a revolution in soft start motor control The future of soft start motor control at your fingertips

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE VOLT CONNECTION(S). IF OTHER VOLTAGE CONNECTIONS ARE AVAILABLE, THE AMPERES WILL

ADS7 AC Contactor Starters

Essential equipment for all your requirements

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

LIQUID STARTER FOR. FOR BALL & SAG MILLS from 1 000kW to kW

Transcription:

320-327 Series Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za

About NewElec NewElec designs and manufactures a wide range of superior electronic motor protection relays for both local and International markets. NewElec's goal, for the past 38 years, has been to exceed the expectations of every client by OFFERING quality products, outstanding customer service and greater value, thus optimizing system functionality and improved operational efficiency. As experts in motor protection, NewElec is involved in every stage of the client's selection of the required protection relay offering ongoing functional and technical support. Our R&D division is continually designing the most up to date motor protection products to meet customer requirements. NewElec's electronic motor protection relays can be found in refineries, mining, steel, petrochemical, pulp and paper, sugar mills, agriculture and material handling industries to name a few, both locally and internationally. The NewElec product range includes software programmable LV motor protection relays for process control applications, protection relays for LV and MV motors, relays for pump motor protection, as well as earth leakage protection relays. NewElec is continually expanding and has recently installed a manufacturing division for its relay housings. This ensures that the final product meets NewElec's precise requirements. With headquarters in Pretoria West, Gauteng, South Africa, NewElec was established in May 1978 and is accredited with ISO 9002.

Why was it designed? For the protection of TEFC S1 rated lightweight LV and MV metric motors with optimised core laminations, windings and reduced thermal overload capacity Protection settings during start-up allow for acceleration times for high inertia loads to full safe Hot and Cold stall times of the motor Thermal overload protection during normal running fixed IDMT hot curve allowing mechanical protection of driven load User-friendly descriptive calibration settings Indication LEDs for monitoring as well as fault indication Motor load indication via 4 to 20 ma output interface to PLC Comprehensive protection of system and motor in the event of fault

Feature Highlights Overload protection even when used on long acceleration times Locked rotor protection timer adjustable in seconds (1-21 or 4-84) Selectable run stall (Jam) protection (150% - 300%) Non-volatile thermal memory calibrated in Starts / Hour (1 12) Thermal memory decay caters for running and standstill conditions Start per hour and programmed consecutive start attempt limitation Thermal overload auto / manual reset facility Adjustable unbalance current single-phasing protection (2% 20%) Earth fault protection (10% In) Short-circuit protection (11 x Ie) Transfer of short-circuit and earth fault to back tripping relay Descriptive fault indication LEDs to assist maintenance personnel

Benefits Accurate overload protection during any phase of operation Unbalance current protection with VSD or soft starter Phase loss single-phasing protection Starts per hour limitation thermal protection Thermal overload protection for long starting times Earth fault protection with selectable stability resistor Short-circuit protection High-energy fault tripping transfer with time delay on contactor circuit Remote thermal / current indication meter Descriptive fault / level monitoring indication LEDs User-friendly calibration settings

Typical Applications Conveyor motor with soft start starter or DOL Fan motors with extended run up time Crusher motors Compressor motors with cyclic loading Ball Mill motors

Specifications Input Current Overload Capacity : 6 x Maximum Load Current setting cont. : 8 x Maximum Load control setting for 5 min Frequency Response : 42 to 66 Hz ± 7% : 1 to 1,2 (le) Maximum Load Current Setting Level Setting Accuracy : ± 4% Linearity : ± 4% Repeatability : ± 1% Detection Level : ± 1% Calibration : Amps R.M.S. Range : 21 : 1 continuous Response: Related to average of 3 input line C.T. s

Specifications Contd. Start Per Hour Limiter Level Setting Accuracy : ± 4% Linearity : ± 4% Repeatability : ± 1% Calibration : Starts per hour Range : 1 to 12 per hour Short Circuit Sensor Tripping Level Tripping delay : 10,5 to 11,2 x max load dial setting : 100ms Overload Trip Delay Curves * See NewElec 320M Series running curve Accuracy : ± 5% for 125 to 1100% overload : ± 10% for 102 to 124% overload : ± 1% for 101% overload

Specifications Contd. Main Trip Relay Configuration : 5 Amps 220Volt A.C. Maximum Load Current Setting Level Setting Accuracy : ± 4% Linearity : ± 4% Repeatability : ± 1% : 1-Form C Common, n/o, n/c Detection Level : ± 1% Calibration : Amps R.M.S. Range : 21 : 1 continuous Response : Related to average of :3 input line C.T. s

Start Timer Start Detection Specifications Contd. : Inrush Current to rise from 10% to 101% of max load current dial setting within 1s Start Range : 4 to 84s Automatic transfer from : Occurs when input current Start to running curve falls below max load current dial setting. Earth Fault Sensor Tripping Level Tripping Delay Reset Lockout Time on Overload Trip : 10% of motor running load : 100ms Monitor control power on : Lockout Time (Min) Starts per hour calibration : (60 / (Ns)) Min ± 5% Selected (Ns) Monitor Control Power Off : 25 min ±15% Auxiliary Relay Contacts Ratings Configuration : 5 Amps 220Volt A.C. : 1-Form C Common, n/o, n/c

Electrical Connection Diagram

Dimensional Diagram

Ordering Information C.T. Ratio Recommended Range (Amps) Code 20:1 0,8 to 12 0 50:1 13 to 30 1 Mounting Code 100:1 31 to 80 2 Flush : F 200:1 80 to 160 3 500:1 160 to 400 4 Chassis: C Control Supply 110: 110V AC 5VA Running Stall A: 3 x M.L.C. B: 2,5 x M.L.C. C: 2 x M.L.C. C.T. 1: 1A Sec 1000:1 400 to 800 5 220: 220V 5: 5A Sec 2000:1 800 to 1680 6 AC 5VA D: 1,5 x Xxx:1 30% to 115% 7 M.L.C.

Ordering Information Example: NewElec 32 3 M F 220 A 1 Code: Options F Immediate overload warning (Option I, O and P disallowed) G Earth Fault H Short Circuit I Transfer options G and H to auxiliary relay (option F and O disallowed) with 1 s delay on main trip relay J 100ms trip time for options G and H(if not selected, 1 s delay will be selected) K Thermal memory override facility L Motor Load and thermal memory analogue indication meter (29m or 39m) M Auto-manual overload trip reset facility N Programmed limitation of start attempts (1, 2 or 3) O Phase unbalanced alarm - trip function disabled (option I, O and P disallowed) P Slave auxiliary relay with main trip relay (option I, O and P disallowed) Example: NewElec 32 3 M F 220 A 1 G H K

We provide a 1 year renewable guarantee We repair products out of guarantee for 50% of their list price and renew the guarantee Local support

Applications particularly well suited for use in conjunction with the NewElec range of electronic motor protection relays. Mining Water Affairs Petro Chemical Refineries Agriculture Material Handling Mills Cable Theft Detection Pulp & Paper