Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Similar documents
Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Contactors. CT1115/04, CT1130/04 CT1215/04, CT1230/04 CT1315/04, CT1330/04 1, 2 and 3 pole power contactors for AC and DC Catalogue C20.

Contactors. C110B/80, C110B/120 C110B/200, C110B/300 Single pole DC NO contactors for industrial trucks Catalogue B71.en

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

Contactors. Brochure. Contactors for industry, rolling stock and battery-powered vehicles Emergency disconnect switches

l Snap-Action Switches

S870, S970 Series. Snap-action switches. Positive opening operation Self-cleaning contacts Catalogue D70.en

l Snap-Action Switches

Play it safe Connectors Switches Contactors. New Energy. Special Switchgear Solutions

S880 Series Snap-action switches with positive opening operation and self-cleaning contacts Catalogue D80.en

Connect - Contact - Control. Fuses for high-voltage switchgear F-HS, F-VS Series Ø 60. F 185.en

Connnectors. B Series Connectors for rail vehicles Catalogue F160.en. More information here: schaltbau-gmbh.com

T-Switches Range. TL Contactors TS disconnectors TP Contactors. TELARC s multipurpose DC and AC current switches for multiple application.

Connect - Contact - Control. Connectors. High Power Connectors for industrial trucks Catalogue A84.en

TECHNICAL DESCRIPTION

Connectors. LV Series High Power Connectors for faster charging of industrial trucks Catalogue A84.en. more information here: schaltbau-gmbh.

TECHNICAL DESCRIPTION

Play it safe Connectors Switches Contactors. Material Handling. Improved performance for rapid charging

TAE pole Contactors

Switches Unlimited Phone: * Fax:

Connectors. M Series Circular Modular Connectors Catalogue A10.en

Selection Guide Motor Control Device Solutions

Connect - Contact - Control. Brochure. l Connectors

COMPONENTS. Off-load Switch for Fixed Installation Title type SW

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Fuse switch disconnectors

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Manual Motor Starters. Meta-MEC

Thermal overload relay TF140DU and TF140DU-V1000

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

DD Frame - Series Circuit Breakers

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Micro Contactor MA Series

vertical fuse switch disconnectors

Phase + Neutral, neutral on right side

Motorized switch-disconnectors OTM 40 to 125 Amperes

Application Mini Contactors for Motors and Resistive Loads

Page 2-4 Page 2-8. Page Page 2-13

Electronic overload relays EF205 and EF370

TRANSPORTATION TECHNOLOGY. Customizing is Our Standard

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

AF40... AF96 3-pole contactors Technical data

Phase + Neutral, neutral on left side

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

RX 3 M.C.B A up to 63 A

Brochure Connectors. More information here: schaltbau-gmbh.com

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

RX 3 M.C.B A up to 63 A

TX³ RCCBs 2P up to 100 A

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

Industrial Contactors CTX 3 3P 185A - 800A

ASL09..S 3-pole Contactors - Spring Terminals

B Mini Contactor V Hz

Short form catalogue. Motor protection & control

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Electronic overload relay EF65, EF96 and EF146

Special Purpose Fuses

Thermal overload relay TF65 and TF96

DX³ RCCBs - ID 4P up to 100 A

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

500V / V /

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

IEC Low Voltage General Purpose Protection

Thermal Overcurrent Circuit Breaker 3120-F...

BC Mini Contactor VDC

Magnetic Overcurrent Circuit Breaker

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Presented to the IAPMO Standards Review Committee on December 9, 2013

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Thermal Overload Relays

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Product Group Brochure. PS Range Capacitor Vacuum Switches

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi

Thermal-Magnetic Circuit Breaker 201/-WA

Meta Solution. Contactors and Overload relays

FL series position switches

Safety technique. Emergency Stop Module BH 5928, BI 5928

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Disconnectors and earthing switches up to 25 kv AC

AE 9... AE 40 Contactors NE... Contactor Relays

up to 63 A (1 module per pole)


BETA Switching Switches and Light Indicators

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Description. Positive safety relays

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

For Info: Phone: Fax:

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Transcription:

Connect - Contact - Control 3 Contactors CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

2 CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V The economical solution for switching medium power AC and DC loads CL Series contactors are available as 1, 2 and 3 pole AC and DC versions. They guarantee reliable, low-wear switching of rated voltages up to 1,500 V and amperages up to. The compact contactors come with an arc chute that has proven itself many times over and are suitable for universal use in the harsh environmental conditions of industrial applications as well as in AC and DC railway networks. Especially robust and environmentally friendly materials - from plastics featuring low smoke and low content of toxic gases up to cadmium-free contact tips - are used for the CL Series. The contactors have been tested and approved by independent laboratories. Features Compact, rugged design Long life Maintenance free in normal operation Rated voltage 1,500 V, current rating max. Double-break, cadmium free main contacts 1, 2 and 3 pole AC and DC versions available Drive system with coil tolerance according to railway standard Functional insulation for main circuit Basic insulation between main circuit and protective earth Reinforced insulation between main circuit and control circuit/ auxiliary circuit Applications Precharge contactor: CL Series contactors are the ideal complement to our CT range. Used as precharge contactors the switchgear is best suited for switching medium power AC and DC loads. Line contactor: CL Series contactactors are particularly suited as main switches of electric heating systems or starter and compressor motors and for switching field circuits of motors. Ordering code Series CL11 CL12 CL13 1 pole NO contactor 2 pole NO contactor 3 pole NO contactor Main contacts: Rated voltage 15 U n = 1,500 V Main contacts: Conv. thermal current 02 I th = Polarity of main contacts* 1 P DC, magnetic blowout, parallel connection G DC, magnetic blowout, series connection X AC, no blowout Example: ( ) ( ) ( ) CL1115/02 P 110ET-U2 2x snap switches W1D1 a 012 * 3, contact material: silver (standard) 2x snap switches W1D a 012 * 3, contact material: gold Aux. contacts: number of* 2 and type U2 Coil suppression Suppressor diode T Coil tolerance -30 % +25 % E Coil voltage 2 / 36 / 72 / 110 V DC I2 Note: Presented in this catalogue are only stock items which can be supplied in short delivery time. For some variants minimum quantities apply. Please do not hesitate to ask for the conditions. Special variant: If you need a special variant of the contactor, please do not hesitate to contact us. Maybe the type of contactor you are looking for is among our many special designs. If not, we can also supply customized designs. In this case, however, minimum order quantities apply. *1 DC contactors are fitted with permanent magnetic blowouts. Select»P«for parallel connection of main contacts. Select»G«for series connection of main contacts. Observe the positive marking + on the arc chute of the contactor! *2 Standard: 1, 2, 3 pole variant: 2x snap-action switch Optional: 2 pole variant: x snap-action switch 3 pole variant: 6x snap-action switch *3 For Series snap-action switches, refer to catalogue D70.

3 Specifications 1115/02 CL1215/02 CL1315/02 Type of voltage DC (bidirectional), AC (f < 60 Hz) Main contacts, number of, configuration 1x SPST-NO 2x SPST-NO 3x SPST-NO Nominal voltage U n 1,500 V 1,500 V 1,500 V Rated operating voltage U e 1,800 V 1,800 V 1,800 V Rated insulation voltage U Nm 2,200 V 2,200 V 2,200 V Rated impulse withstand voltage U Ni 12 kv 12 kv 12 kv Pollution degree / Overvoltage category PD3 / OV3 PD3 / OV3 PD3 / OV3 Switching surge overvoltage U e = 1,800 V < 6.6 kv < 6.6 kv < 6.6 kv Conventional thermal current I th at T a = 0 C / at T a = 70 C / 200 A / 200 A / 200 A Component category (IEC 60077-2) A2 A2 A2 Short-circuit making capacity I cm 1,5 ka 1,5 ka 1 ka Breaking capacity I cn (T2 < 15 ms) DC, U e = 720 V DC, U e = 1,200 V DC, U e = 1,800 V Breaking capacity I cn (T2 < 1 ms) DC, U e = 720 V DC, U e = 1,200 V DC, U e = 1,800 V Breaking capacity I cn (cosφ = 0,8) AC, U e = 720 V (f = 50 Hz) AC, U e = 1,200 V (f = 50 Hz) AC, U e = 1,800 V (f = 50 Hz) Breaking capacity I cn (cosφ = 1) AC, U e = 720 V (f = 50 Hz) AC, U e = 1,200 V (f = 50 Hz) AC, U e = 1,800 V (f = 50 Hz) Rated short-time withstand current I cw (T < 100 ms) 2. ka 2. ka 2.3 ka Critical current range None None None Main contacts Contact material Terminals Torque Aux. contacts Number of and type Contact material breaking capacity (T = 5 ms) Terminals Magnetic drive Pollution degree / Overvoltage category Coil voltage U s Coil tolerance 20 A 15 A 10 A 00 A 90 A 50 A 150 A 800 A 20 A 15 A 10 A 00 A 90 A 50 A 150 A 800 A AgSnO 2 M8 6 Nm max. 2x Silver / Gold DC13: 110 V / 0.2 A / 2 V / 2 A Flat tabs 6.3 x 0.8 mm PD3 / OV2 2 / 72 / 110 V DC -30 %... +25 % U s Power consumption at U s and T a = 20 C cold / warm coil < 29 W / < 21 W < 31 W / < 22 W < 2 W / < 30 W Pull-in time, at T a = 20 C typ. Drop-off voltage, at T a = 20 C typ. Drop-off time, at T a = 20 C typ. Switching frequency at T a = 20 C and 1.25 U s Coil suppression Coil terminals Ingress protection rating (IP code) Mechanical endurance Vibration / Shock (EN 61373) Mounting orientation Ambient conditions Operating / Storage temperature Altitude Humidity (EN 50125-1) 80 ms 0.1... 0. x U s < 20 ms operations/minute Suppressor diode M3 screws IP00 > 3 million operating cycles Category 1, Class B Horizontal / Vertical -0 C +70 C / -0 C +85 C < 2,000 m above sea level < 75 % yearly average Weight < 2.7 kg <.9 kg < 7.6 kg 20 A 15 A 10 A 00 A 90 A 50 A 150 A 800 A

CL1115/02 1 poles NO contactor Dimensions, mounting, circuit diagram Dimensions 10 min. 10 min. 175 13 ±1 M8 69 ±1 80.7 ±1 192. ±1 179. ±1 66 ±1 M6 75 ±1 5 x 7 57 Aux. contact 2x Arc chute 21 22 2 200 ±1 10 11 12 1 Main terminal screw M8 Coil terminal screw M3 PE terminal screw M6 Mounting plate 20 Mounting holes Circuit diagram DC contactors: polarity sensitive main contacts»p«1+ 12 1 22 2 120 ±0.2 A2 2 11 21 AC contactors: non-polarity sensitive main contacts»x«1 12 1 22 2 A2 2 11 21 (bottom view) 16 ±0.2 Mounting holes 5x Ø7 32 ±0.2 Dimensions in mm

5 CL1215/02 1 poles NO contactor Dimensions, mounting, circuit diagram Dimensions 10 min. 101 ±1 10 min. 175 ±1 13 ±1 M8 21 22 2 200 ±1 10 6 73 ±1 8.7 ±1 196. ±1 18 ±1 M6 101 ±1 80 ±1 3 x 7 95 Aux. contact 2x Arc chute 11 12 1 Main terminal screw M8 Coil terminal screw M3 PE terminal screw M6 20 26 6 ±0.2 Mounting plate Mounting holes Circuit diagram DC contactors: polarity sensitive main contacts»p«1+ 3+ 12 1 22 2 120 ±0.2 2 11 21 A2 DC contactors: polarity sensitive main contacts»g«1+ 12 1 22 2 Dimensions in mm Mounting holes 3x Ø7 60 ±0.2 (bottom view) 2 3+ 11 21 A2 AC contactors: non-polarity sensitive main contacts»x«1 3 12 1 22 2 2 11 21 A2

6 CL1315/02 3 pole NO contactor Dimensions, mounting, circuit diagram Dimensions 12 175 ±1 10 min. 10 min. 13 ±1 M8 125 21 22 2 200 ±1 160 8 77 ±1 200 ±1 187 ±1 Coil terminal screw M3 88.7 ±1 M6 13 ±1 89 ±1 6 x 7 Aux. contact 2x Arc chute 11 12 1 Main terminal screw M8 Coil terminal screw M3 PE terminal screw M6 Mounting plate 20 26 26 6 ±0.2 6 ±0.2 Mounting holes Circuit diagram AC contactor: non-polarity sensitive main contacts»x«1 3 5 12 1 22 2 138 ±0.2 A2 2 6 11 21 Mounting holesx Ø7 (bottom view) 5 ±0.2 Dimensions in mm

7 Mounting instructions Safety instructions Mounting CL Series contactors can be mounted horizontally or vertically. Use mounting plates or mounting frames which are strong enough to carry the weight of the contactor even under shock and vibration. This is especially true for use of the contactors in the rough railway environment. Depending on the number of contacts, the contactors are to be affixed with 3 or M6 screws. Use suitable screws with washers and observe tightening torque of the mounting screws: CL1115/02 3 x M6 or x M6 CL1215/02 3 x M6 CL1315/02 x M6 Mounting orientations»h«horizontal Tightening torque 10 Nm max.»v«vertical The switching device meets the requirements of basic insulation. Make sure the plate onto which the drive of the contactor is mounted is earthed in a vibration resistant way. Do not use contactor without properly mounted arc chute. The contactor has non-insulated live parts and carries a label that warns of the hazard. This caution must be observed and the label must not be removed in any way. Observe the required clearance of live parts to ground and other parts of the contactor as well as the safety regulations of the applicable standards. Switching at maximum breaking capacity might require larger clearance! Do not hesitate to ask our advice for dimensioning. Coil suppression for reducing surges when the coil is switched off is optimally attuned to the contactor s switching behaviour. The existing opening characteristic must not be negatively influenced by parallel connection with an external diode. Improper handling of the contactor, e.g. when hitting the floor with some impact, can result in breakage, visible cracks and deformation. Electrical requirements Observe clearance to non-insulated live parts and earth. When switching high loads, the minimum time between switching operations is 30 seconds. After 3 switching operations make sure that there is a fault closure for 10 minutes. To prevent flashovers and excessive contact wear, ensure adequate ventilation of the contactor. Observe the minimum cross sections of wires and current bars that are to be connected to the main terminals of the contactor and to its PE terminal. Spare parts Items Description Ordering code 1 1 AC arc chute, complete with fixed contacts and contact bridge DC arc chute, complete with fixed contacts and contact bridge 1-2757-336205 1-2757-336206 Defective parts must be replaced immediately! Maintenance instructions For detailed maintenance, safety and mounting instructions please refer to our operating manual C25/02-M.en! CL Series contactors are maintenance free with normal use. Make regular inspections once or twice a year. So when installing the contactor, make sure that there is enough space to remove and replace the arc chute with ease and that the main contacts become accessible for inspection. Frequent switching or switching under high load may lead to increased wear of the main contacts. In this case replacement of the main contacts may become necessary. 1 Series auxiliary switch 1-1570-1982 Standards IEC 60077: Railway applications Electric equipment for rolling stock EN 5012-1: Railway applications Insulation coordination Part 1: Basic requirements Clearances and creepage distances for all electrical and electronic equipment IEC 61373: Railway applications - Rolling stock equipment - Shock and vibration tests

Schaltbau GmbH For detailed information on our products and services visit our website or give us a call! with compliments: Schaltbau GmbH Hollerithstrasse 5 81829 Munich Germany Phone +9 89 9 30 05-0 Fax +9 89 9 30 05-350 Internet www.schaltbau-gmbh.com e-mail contact@schaltbau.de RoHS 2011/65/EC Schaltbau GmbH manufactures in compliance with RoHS. The production facilities of Schaltbau GmbH have been IRIS certified since 2008. Quality you can count on Schaltbau Certified to DIN EN ISO 1001 since 2002. For the most recent certificate visit our website. Quality you can count on Schaltbau Certified to DIN EN ISO 9001 since 199. For the most recent certificate visit our website. Electrical Components and Systems for Railway Engineering and Industrial Applications Connectors Connectors manufactured to industry standards Connectors to suit the special requirements of communications engineering (MIL connectors) Charging connectors for battery-powered machines and systems Connectors for railway engineering, including UIC connectors Special connectors to suit customer requirements Snap-action switches Snap-action switches with positive opening operation Snap-action switches with self-cleaning contacts Enabling switches Special switches to suit customer requirements Contactors Single and multi-pole DC contactors High-voltage AC/DC contactors Contactors for battery powered vehicles and power supplies Contactors for railway applications Terminal bolts and fuse holders DC emergency disconnect switches Special contactors to suit customer requirements Electrics for rolling stock Equipment for driver's cab Equipment for passenger use High-voltage switchgear High-voltage heaters High-voltage roof equipment Equipment for electric brakes Design and engineering of train electrics to customer requirements C2013/1312/1.0 Printed in Germany We reserve the right to make technical alterations without prior notice. For updated product information visit www.schaltbau-gmbh.com. Issued 12-2013