Modular contactor for installation into distribution boards

Modular contactors and relays

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Industrial Contactors CTX 3 3P 185A - 800A

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

W Datasheet: DIN Rail Contactors, series AMPARO

Switches Unlimited Phone: * Fax:

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Page 2-4 Page 2-8. Page Page 2-13

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Industrial contactors CTX-1

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

K50H004UP cam changeover switch - 4-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

AF40... AF96 3-pole contactors Technical data

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Installation Contactors RIC, RAC

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Phase + Neutral, neutral on right side

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

B Mini Contactor V Hz

Modular Contactors and Switches D681E121

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Cylindrical fuse-link

Phase + Neutral, neutral on left side

MS25 59 MS RI RI RV 60, RV 120 RS 76 CDB3X 77 Surface Mounted (INO) and Flush Munted (IPO) Compact Distribution Boards 78

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Fuse holders and fuses

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

Thermal Overload Relays

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

SD Series Non-Fused Load Switches

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

MS25, MST25, MS20, MST20

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

SWITCH DISCONNECTORS PLANET -SWITCH.

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Page 2-4 Page 2-8. Page Page 2-12

1 Phase electronic contactor (SC 1)

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Series KTU7 UL489 Molded Case Circuit Breakers

Miniature Circuit Breaker

Command and signalling E 250, E 259 selection table

CI-TI Contactors and motor starters Types CI 61 - CI 98

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED


BC Mini Contactor VDC

BETA Switching Switching Devices

Controls. CONTACTORS CWB Line (up to 40A)

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Modulostar CMS10 Modular fuse-holders

DX³ 4-pole RCBO 6000 A/10 ka

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Vistop TM isolating switches 63 to 160A

ASL09..S 3-pole Contactors - Spring Terminals

TAE pole Contactors

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Application Mini Contactors for Motors and Resistive Loads

K50F003UP cam changeover switch - 3-pole A - screw mounting

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

K63F003UP cam changeover switch - 3-pole A - screw mounting

Modular contactors, type CR

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Mini contactors B6, BC6 with 3 pole

The effective choice The benefits of a product with the highest quality standards

Thermal overload relay TF65 and TF96

Electronic overload relays EF205 and EF370

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Electronic overload relay EF65, EF96 and EF146

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

DRX 125 Circuit breaker (not adjustable)

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

DX³ RCCBs - ID 4P up to 100 A

Products and solutions for photovoltaic applications

Series KTU7 UL489 Molded Case Circuit Breakers

Safety rope switches with reset for emergency stop

1489-M Circuit Breakers

and other modular devices for low voltage installation

Transcription:

Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC operational power: 4kW, 11kW and kw (AC3 400V) Ideal for civil or industrial installations, such as office buildings, stores, hospitals, hotels, etc.

MODULAR CONTACTORS Two, three and four-pole versions, 20A to 63A Very silent during operation or control stage Operation flag indicator Add-on auxiliary contacts. SEC. - PAGE Modular contactors Contactors... - 2 Add-on blocks and accessories... - 3 Dimensions... - 4 Wiring diagrams... - 4 Technical characteristics... - 5 CIRCUIT PROTECTION AND ISOLATION

CN contactors CN20... CN25... CN40... Order code Rated Configura- Qty Wt auxiliary tion and n per supply voltage of contacts pkg [V] NO NC n [kg] One-pole or two-pole. CN20 11 024 º 24VAC/DC 1 1 10 0.135 CN20 11 220 º 220-230VACª 1 1 10 0.135 CN20 20 024 º 24VAC/DC 2 10 0.135 CN20 20 220 º 220-230VACª 2 10 0.135 Order code Rated Configura- Q.ty Wt auxiliary tion and n per supply voltage of contacts pkg [V] NO NC n [kg] Three-pole or four-pole. CN25 10 024 24VAC/DC 4π 5 0.260 CN25 10 220 220-230VACª 4π 5 0.260 CN25 01 024 24VAC/DC 3 1π 5 0.260 CN25 01 220 220-230VACª 3 1π 5 0.260 Three-pole or four-pole. CN40 10 024 24VAC/DC 4π 5 0.425 CN40 10 220 220-230VACª 4π 5 0.425 CN40 01 024 24VAC/DC 3 1π 5 0.425 CN40 01 220 220-230VACª 3 1π 5 0.425 Three-pole or four-pole. CN63 10 024 24VAC/DC 4π 5 0.425 CN63 10 220 220-230VACª 4π 5 0.425 CN63 01 024 24VAC/DC 3 1π 5 0.425 CN63 01 220 220-230VACª 3 1π 5 0.425 Other voltages on request. Consult Customer Service; see contact details on inside front cover. 2NC version supplied on request. The last (NC) pole has the same characteristics as the power pole. It can therefore be used indifferently as an auxiliary or as a NC power contact. π The fourth NO or NC pole has the same characteristics as the power poles; therefore it can be used indifferently as auxiliary or as power contact. On request CN25 and CN40 contactors in the following versions can be supplied: 2NO + 2NC or 4NC power poles. Consult Customer Service; see contact details on inside front cover. ª Can also operate at 220VDC. º No auxiliary contacts can be mounted. General characteristics DC powered magnetic core system assuring silent operation and noise damping during the control phase Overvoltage protection circuit and voltage peak limitation of the magnetic core Equipped with 2 or 4 closing contacts of equal capacity permitting use in power or auxiliary circuits Operation flag indicator Fast mounting. Operational characteristics Type IEC conventional IEC cperating Protection free-air thermal power fuse current Ith in AC3 gg (IEC) in AC1 230V 400V [A] [kw] [kw] [A] CN20... 20 1.3 20 CN25... 25 2.2 4 35 CN40... 40 5.5 11 63 CN63... 63 8.5 80 Noise level: Closed contactor 20dB Making/breaking operation 50dB IEC degree of protection: IP20 Mounting on 35mm DIN rail (IEC/EN 60175). When contactors are mounted side by side and operate in continuous service ( 1 hour), spacing is needed between equipment to consent appropriate cooling. 9mm spacing is required; there is an accessory, called half-module spacer, order code CNX 80, for this specific type of mounting. The following table indicates details of the space needed between each. Maximum number of contactors to be mounted side-by-side without spacing; the CNX 80 spacer is required when the number of pieces is more than the indicated below: CN20 CN25 CN40 CN63 Ambient 3 3 3 3 temperature 40 C Ambient 2 2 3 2 temperature >40...55 C CN63... Operational characteristics of contactor-incorporated auxiliary contacts Type IEC insulation IEC rating (AC category) voltage Ui 230V 400V [V] [A] [A] CN20... 440 6 6 CN25... 440 6 4 CN40... 500 6 4 CN63... 500 6 4 Certifications and compliance Certifications obtained: EAC. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, IEC/EN 61095. Utilisation Lighting systems Electric home heating Heat pumps Conditioning Ventilation Civil installations. Lighting circuit switching See page -6. -2 Add-on blocks/accessories page -3 Dimensions page -4 Wiring diagrams page -4 Technical characteristics page -5 to 7

Add-on blocks and accessories CNH... Order code Characteristics Max Qty Wt qty per per contactor pkg n n [kg] Auxiliary contacts. CNH 11 1NO + 1NC 1 1 0.044 CNH 20 2NO 1 1 0.044 Set for terminal protection (also sealable). CNP 0 For CN20 2 1 0.001 CNP 1 For CN25 2 1 0.002 CNP 2 For CN40 2 1 0.003 and CN63 Spacer. CNX 80 1/2 module wide 1 10 0.013 Not suitable for CN20 modular contactors. Set of 2 pieces. Mounting Fasten the CNH... auxiliary contact by slightly pressing it in place. Operational characteristics for auxiliary contacts IEC rated insulation voltage: 440VAC IEC conventional free air thermal current Ith: 6A Minimum switching capacity: 5mA 12V Conductor section: 1...2.5mm 2 Maximum tightening torque: 1Nm. Certifications and compliance Certifications obtained: EAC. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, IEC/EN 61095. CNP2 Removal Release the catch using a screwdriver. Dimensions page -4 Wiring diagrams page -4-3

Dimensions (mm [in]) CONTACTORS CN20... CN25... CN40... CN63... 17.5 (0.69 ) 60 (2.26 ) 43 (0.69 ) 60 84 (3.31 ) 45 (1.77 ) (1 77 ) 5.5 (0.22 ) ADD-ON BLOCKS Contact blocks CNH... Spacer CNX80 10 (0.39 ) 60 (2.26 ) 43 (0.69 ) 9 (0.35 ) 67 (2.64 ) 84 (3.31 ) 45 (1.77 ) 45 (1.77 ) 2 (0.08 ) 5.5 (0.22 ) Wiring diagrams TWO-POLE MODULAR CONTACTORS THREE AND FOUR-POLE MODULAR CONTACTORS CN20 11 CN20 20 CN25 01 CN40 01 CN63 01 CN25 10 CN40 10 CN63 10 A1 1 21 A1 1 3 A1 1 3 5 21 A1 1 3 5 13 (7) A2 2 22 A2 2 4 A2 2 4 6 22 A2 2 4 6 14 (8) The NC contact has the same characteristics as the power pole contact. Therefore, it can be used indifferently as an auxiliary or as a NC power pole contact. The fourth pole NO or NC has the same characteristics as the power poles. Therefore, it can be used indifferently as auxiliary or as power pole contact. ADD-ON AUXILIARY CONTACTS CNH11 CNH20 51 63 53 63 52 64 54 64-4

Technical characteristics TYPE CN20... CN25... CN40... CN63... CONTACT CHARACTERISTICS IEC conventional free air thermal current Ith ( 40 C) A 20 25 40 63 IEC rated insulation voltage Ui V 230 440 440 440 IEC rated impulse withstand voltage Uimp kv 4 4 4 4 Minimum switching capacity 17V, 50mA 17V, 50mA 17V, 50mA 17V, 50mA Average coil consumption in-rush and holding W 2.5 3 5 5 Maximum tightening torque for Nm 0.6 0.6 0.6 0.6 coil terminals lbft 0.44 0.44 0.44 0.44 Tool PZ1 PZ1 PZ2 PZ2 Coil conductor section min. mm 2 1 max. mm 2 2,5 Maximum tightening torque Nm 1.2 1,2 2 2 for power terminals lbft 0.9 0.9 1.48 1.48 Tool PZ1 PZ1 PZ2 PZ2 Power conductor section min. mm 2 2.5 2.5 1 1 max. mm 2 6 6 25 25 AC/DC CONTROL CIRCUIT Operating voltage pick-up % Us 85-110 limits drop-out % Us 20-25 OPERATING TIMES Average time closing NO ms -45-45 -20-20 opening NO ms 25-50 20-70 35-45 35-45 LIFE Mechanical cycles 3,000,000 3,000,000 3,000,000 3,000,000 Electrical (in AC3 duty) cycles 300,000 500,000 0,000 0,000 Electrical (in AC1 duty) cycles 200,000 200,000 100,000 100,000 AMBIENT CONDITIONS Operating temperature C -5...+55 Storage temperature C -30...+80-5

Technical characteristics LIGHTING CIRCUIT SWITCHING Lamp features Lamp Retd Capacitor Maximum number [n] of lamps each contactor pole power current power 230V 50Hz [W] [A] [µf] CN20 CN25 CN40 CN63 INCANDESCENT AND TUNGSTEN 60 0.26-23 29 65 85 HALOGEN 100 0.43-14 16 40 50 200 0.87-7 8 20 25 500 2.17-3 3 8 10 1000 4.35-1 1 4 5 ENERGY SAVING 3 0,03-50 60 0 200 5 0.04-45 55 135 180 7 0.055-40 50 12 160 8 0.065-35 45 110 0 9 0.075-30 40 100 140 10 0.08-30 40 100 140 11 009-30 40 100 140 12 0.10-25 35 95 120 14 0.11-25 35 90 120 0.12-20 30 85 1 16 0.13-20 30 80 105 18 0.145-18 26 70 95 20 0.16-17 22 65 85 21 0.17-20 60 80 23 0.185-20 60 70 24 0.195-20 55 70 30 0.16-20 55 70 FLUORESCENT 18 0.37-22 24 90 140 not corrected and series correction 24 0.35-22 24 90 140 36 0.43-17 20 65 95 58 0.67-14 17 45 70 FLUORESCENT 18 0.11-30 40 100 0 DUO circuit (lead-lag) 24 0.14-24 31 78 118 36 0.22-17 24 65 95 58 0.35-10 14 40 60 FLUORESCENT 18 0.12 4.5 7 8 48 73 corrected 24 0. 4.5 7 8 48 73 36 0.2 4.5 7 8 48 73 58 0.32 7 4 5 31 47 ELECTRONIC FLUORESCENT BALLAST 1 x 18 0.09-25 35 100 140 1 x 36 0.16-20 52 75 1 x 58 0.25-14 19 50 72 2 x 18 0.17-12 17 50 70 2 x 36 0.32-7 10 26 38 2 x 58 0.49-7 9 25 36 HIGH-PRESSURE MERCURY VAPOUR 50 0.61-14 18 38 55 not corrected 80 0.8-10 13 29 42 125 1. - 7 9 20 29 250 2. - 4 5 10 400 3.25-2 3 7 10 700 5.4-1 2 4 6 1000 7.5-1 1 3 4 HIGH-PRESSURE MERCURY VAPOUR 50 0.28 7 4 5 31 47 corrected 80 0.41 8 4 5 27 41 125 0.65 10 3 4 22 33 250 1.22 18 1 2 12 18 400 1.95 25 1 1 9 13 700 3.45 45 - - 5 7 1000 4.8 60 - - 4 5-6

Technical characteristics Lamp features Lamp Retd Capacitor Maximum number [n] of lamps each contactor pole power current power 230V 50Hz [W] [A] [µf] CN20 CN25 CN40 CN63 METAL HALIDE 35 0.53-18 22 43 60 not corrected 70 1-10 12 23 32 0 1.8-5 7 12 18 250 3-3 4 7 10 400 3.5-3 3 6 9 1000 9.5-1 1 2 3 2000 16.5 - - - 1 1 METAL HALIDE 35 0.25 6 5 6 36 50 corrected 70 0.45 12 2 3 18 25 0 0.75 20 1 1 11 250 1.5 33-1 6 9 400 2.5 35-1 6 8 1000 5.8 95 - - 2 3 2000 11.5 148 - - 1 2 HIGH-PRESSURE SODIUM VAPOUR 0 1.8-5 6 17 22 not corrected 250 3-3 4 10 13 400 4.7-2 2 6 8 1000 10.3 - - 1 3 3 HIGH-PRESSURE SODIUM VAPOUR 0 0.83 20 1 1 11 16 corrected 250 1.5 33-1 6 10 400 2.4 48 - - 4 6 1000 6.3 106 - - 2 3 LOW-PRESSURE SODIUM VAPOUR 18 0.35-22 27 71 90 not corrected 35 1.5-7 9 23 30 55 1.5-7 9 23 30 90 2.4-4 5 14 19 135 3.5-3 4 10 13 180 3.3-3 4 10 13 LOW-PRESSURE SODIUM VAPOUR 18 0.35 5 6 7 44 66 corrected 35 0.31 20 1 1 11 16 55 0.42 20 1 1 11 16 90 0.63 26 1 1 8 12 135 0.94 45 - - 4 7 180 1.16 40 - - 5 8 LED LIGHTING BALLAST 10V, 12V, 24V,...; 350mA, 500mA, 750mA... N =2400/In N =3800/In N =5600/In N =11000/In N = Number of controlled ballasts In = Ballast rated current in ma Example of calculation with 500mA ballast: Considering type CN40, then N = 5600 / 500 = 11.2. Therefore, the maximum number of ballasts which each CN40 power pole can be connected to and control is 11. -7