Installation Contactors RIC, RAC

Similar documents
RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Modular contactor for installation into distribution boards

Industrial Contactors CTX 3 3P 185A - 800A

Modular contactors and relays

W Datasheet: DIN Rail Contactors, series AMPARO

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

For Info: Phone: Fax:

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Technical Information

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

AF40... AF96 3-pole contactors Technical data

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

BC Mini Contactor VDC

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

ASL09..S 3-pole Contactors - Spring Terminals

Application Mini Contactors for Motors and Resistive Loads

Quick selection table

B Mini Contactor V Hz

TAE pole Contactors

AF series contactors (9 2650)

max pole for t=15 ms

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

3VU13, 3VU16 Circuit-Breakers

Description. Positive safety relays

RX 3 M.C.B A up to 63 A

Command and signalling E 250, E 259 selection table

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

AF series contactors (9 2650)

RX 3 M.C.B A up to 63 A

BETA Switching Switching Devices

All round protection guaranteed

Ktec Contactors and thermal overloads

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

MS25, MST25, MS20, MST20

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Essential equipment for all your requirements

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Application Mini Contactors for Motors and Resistive Loads

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

functions: --Staircase timer --Staircase timer + maintenance function --Staircase timer with early warning

Technical Information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Modular Contactors and Switches D681E121

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

AE 9... AE 40 Contactors NE... Contactor Relays

CI-TI Contactors and motor starters Types CI 61 - CI 98

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

DC/DC converters - MINI-PS DC/ 5-15DC/

A7 Magnetic Contact/Switch CONTENTS

Controls. CONTACTORS CWB Line (up to 40A)

Thermal overload relay TF65 and TF96

MS25 59 MS RI RI RV 60, RV 120 RS 76 CDB3X 77 Surface Mounted (INO) and Flush Munted (IPO) Compact Distribution Boards 78

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Micro Contactor MA Series

Series CA5 Contactors

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Solid State Relays contactor with Integrated Fuse Type RGC1F

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Electronic overload relay EF65, EF96 and EF146

Phase + Neutral, neutral on left side

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Electronic overload relays EF205 and EF370

(1,5 modules per pole)

Capacitor Switching Contactors Type K3...-A, K3...-K

Mini contactors B6, BC6 with 3 pole

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Multi-function. Mono-function 1 NO (SPST-NO)

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Phase + Neutral, neutral on right side

RUC industrial relays of small dimensions

Manual motor starter MS132

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

Manual motor starter MS132

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

XMC0 Series. Definite Purpose Contactors

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Manual motor starter MS132

6mm and 14mm Slim Interface Relay

Transcription:

Installation Contactors RIC, RAC 1 Characteristics Rated operational current: 20 63 A Coil voltages: UC 24, 36, 230 V / AC 400 V Hum-free (UC versions) 2 4 contacts NC or NO Extendable with auxiliary contacts Double break contacts Status indicator RAC with manual actuating (On-Off-Auto) 2 Ordering code 2.1 Two-pole contactors Contacts / RIC25 2 NO -200/ 2 NC -020/ 1 NC + 1 NO -110/ 2 CO RIC25-002 -200/ -020/ -110/ 2.2 Four-pole contactors Contacts RIC25 RIC40 RIC63 RAC25 4 NO RIC25-400/ AC48V AC400V RIC40-400 RIC63-400/ RAC25-400/ 4 NC RIC25-040/ AC400V RIC40-040/ RIC63-040/ 2 NC + 2 NO RIC25-220/ AC400V RIC40-220/ RIC63-220/ 2.3 Auxiliary contacts Contacts RIC-AUX* 2 NO RIC-AUX20 2 NC RIC-AUX02 1 NC + 1 NO RIC-AUX11 * RIC-AUX are compatible to RIC 25/40/63 only 19.07.2016 Vs;'Sc 1/6

3 Mounting If several contactors are mounted side by side, the spacer RIC-DIST should be installed after every second contactor for purpose of heat dissipation. 3.1 Mounting position 4 Pin assignment RIC RAC RIC-AUX RICxx-200-200 RIC-AUX 20 RICxx-020-020 RIC-AUX 02 RICxx-110-110 RIC-AUX 11 RICxx-400 RICxx-040 RICxx-220 RICxx-002 19.07.2016 Vs;'Sc 2/6

5 Technical information 5.1 General data 5.1.1 Mechanical data Mounting Connection Protection class Housing material DIN rail Screw terminals IP20 Technyl PA6 Module width 1 2 3 3 0.5 Dimensions W x H x D [mm] 17.5 x 65.5 x 85 35 x 65.5 x 85 54.5 x 65.5 x 85 54.5 x 65.5 x 85 8 x 65.5 x 85 Conductor cross-section main terminals, rigid [mm 2 ] 1... 10 1... 10 1... 25 1... 25 1... 2.5 Conductor cross-section main terminals, flexible [mm 2 ] 1... 6 1... 6 1... 16 1... 16 1... 1.5 Conductor cross-section coil terminals, rigid / flexible [mm 2 ] 1... 2.5 1... 2.5 1... 2.5 1... 2.5 - Torque main terminals [Nm] 1.2 1.2 2 2 0.8 Torque coil terminals [Nm] 0.6 0.6 0.6 0.6 - Weight [g] 140 / 130 270 420 420 50 5.1.2 Environmental conditions Storage temperature -30 C... +80 C Operating temperature -5 C... +55 C Relative humidity 95%, non-condensing 5.2 Electrical data 5.2.1 Supply UC UC RIC25 UC RIC25 AC RIC40 UC RIC63 UC Rated voltages U N [V] 24, 36, 230 24, 36, 230 400 24, 230 24, 230 Frequency [Hz] DC, 40 500 DC, 40 500 50 60 DC, 40 500 DC, 40 500 Operating voltage range 0.85... 1.1 x U N Coil consumption [VA/W] 2.1 / 2.1 2.6 / 2.6 5.5 / 1.6 5 / 5 5 / 5 Make delay [ms] 15 45 15 45 10 30 15 20 15 20 Brake delay [ms] 20 50 20 70 10 30 35 45 35 45 5.3 Main contacts Rated voltage [V] 400 Thermal current AC1, I th [A] 20 25 40 63 6 Inrush current 100 ms [A] 50 50 150 150 - Operational voltage [V] 24 400 Mechanical endurance 3 x 10 6 Electrical endurance AC-1 at I th 2 x 10 5 2 x 10 5 1 x 10 5 1 x 10 5 50 x 10 3 Electrical endurance AC-3 at I th 3 x 10 5 5 x 10 5 1.5 x 10 5 1.5 x 10 5 50 x 10 3 Electrical endurance DC-1 at I th 1x10 5 1x10 5 1x10 5 1x10 5 50 x 10 3 19.07.2016 Vs;'Sc 3/6

Contact material AgNi AgNi AgSnO 2 AgSnO 2 AgNi Minimal load at 24 V [ma] 50 50 50 50 5 Distance of open contacts [mm] 3.6 3.6 3.6 3.6 - Max. back-up fuse [A] 20 25 63 80 6 5.4 Typical performance 5.4.1 AC RIC25 RIC40 RIC63 Rated operational current AC-1 [A] Rated operational current AC-7a [A] 20 25 40 63 Rated operational current AC-3 [A] Rated operational current AC-7b [A] Rated operational current AC-4 [A] 5.4.2 DC 9 (NO) 6 (NC) 0.37 (NO) 0.25 (NC) 8.5 22 30 RIC25 RIC40 RIC63 Contacts in series 1 2 1 2 3 4 1 2 3 4 1 2 3 4 Rated op. current DC-1 24 V [A] 20 20 25 25 25 25 40 40 40 40 63 63 63 63 Rated op. current DC-1 48 V [A] 15 18 20 25 25 25 24 38 40 40 26 42 63 63 Rated op. current DC-1 110 V [A] 6 10 6 10 20 20 4 10 30 40 4 10 35 63 Rated op. current DC-1 220 V [A] 0.6 6 0.6 6 15 15 1.2 8 20 40 1.2 8 30 63 Rated op. current DC-3 24 V [A] 10 20 15 25 25 25 22 40 40 40 25 45 63 63 Rated op. current DC-3 48 V [A] 5 10 8 16 25 25 10 20 40 40 11 22 45 63 Rated op. current DC-3 110 V [A] 1 4 1.3 5.5 15 20 1.5 5 15 40 1.5 5 18 63 Rated op. current DC-3 220 V [A] 0.1 0.4 0.2 0.6 3 8 0.3 1 4 10 0.3 1 5 10 Rated op. current DC-5 24 V [A] 10 20 15 25 25 25 20 40 40 40 25 45 63 63 Rated op. current DC-5 48 V [A] 4 8 5 15 25 25 8 18 28 40 10 20 44 63 Rated op. current DC-5 110 V [A] 0.3 2 0.5 4 12 15 1 5 12 35 1 5 15 45 Rated op. current DC-5 220 V [A] 0.06 0.2 0.1 0.4 2 5 0.2 0.8 3 8 0.2 0.8 4 10 Rated op. current DC-13 110 V [A] 0.3 1 Rated op. current DC 110 V, L/R 40 ms [A] 3 6 5.4.3 Lamp loads Maximum number of lamps per contact at 230V, utilization category AC-5a. The following information applies to 100 000 cycles. Load Incandescent lamps and halogen lamps Power [W] Current [I] RIC25 RIC40 RIC63 20 0.09 100 110 200 250 25 0.11 80 88 160 200 30 0.13 67 73 133 167 35 0.15 57 63 114 143 46 0.20 43 48 87 109 50 0.22 40 44 80 100 19.07.2016 Vs;'Sc 4/6

Load Transformators for low-voltage halogen lamps (electromagnetic and electronic) Compact fluorescent lamps with internal ballasts Fluorescent lamps with external electromagnetic ballasts LED-Lamps Power [W] Current [I] RIC25 RIC40 RIC63 57 0.25 35 39 70 88 60 0.26 33 37 67 83 75 0.33 27 29 53 67 100 0.44 20 22 40 50 150 0.65 13 15 27 33 300 1.30 7 7 13 17 30 0.13 33 40 90 143 40 0.17 25 30 68 108 50 0.22 20 24 54 86 60 0.26 17 20 45 72 70 0.30 14 17 39 61 100 0.44 10 12 27 43 150 0.65 7 8 18 29 200 0.87 5 6 14 22 300 1.30 3 4 9 14 7 0.08 64 86 236 300 9 0.10 50 67 183 233 11 0.12 41 55 150 191 13 0.14 35 46 127 162 18 0.20 25 33 92 117 26 0.27 17 23 63 81 18 0.09 39 53 139 200 2x18 0.17 21 28 74 106 21 0.11 32 43 114 164 2x21 0.22 16 22 57 82 28 0.14 25 34 89 129 2x28 0.27 13 18 46 67 35 0.17 21 28 74 106 2x35 0.34 10 14 37 53 54 0.26 13 18 48 69 2x54 0.52 7 9 24 35 58 0.25 14 19 50 72 2x58 0.48 7 10 26 38 80 0.40 9 12 31 45 2x80 0.76 5 6 16 24 Power supplies for LEDs N: Number of lamps or power supplies - - N = 2,4 A / In N = 3,8 A / In N = 11 A / In N = 18 A / In In: Current consumtion per lamp or power supply 6 Operation The contactor RAC can be manually locked in the position On or Off. In position Auto, the contactor is conventionally operated with the coil. 19.07.2016 Vs;'Sc 5/6

7 Dimensions *optional sealing cover: RIC-SEAL20, RIC-SEAL25, RIC-SEAL40-63 *optional spacer RIC-DIST 8 Standards IEC/EN 60947-4-1, VDE 0660 Low voltage switchgear - general establishments IEC/EN 60947-5-1 Low voltage switchgear - control circuit devices and switching elements IEC/EN 61095, VDE 0637 Electromechanical contactors for household and similar purposes CE, RoHS 19.07.2016 Vs;'Sc 6/6