Planned Preventative Maintenance Schedule. Chilled Water Systems PPM Schedule

Similar documents
Planned Preventative Maintenance Schedule. Chilled Water Systems PPM Schedule. Data Centre Solutions Expertly Engineered

Planned Preventative Maintenance Schedule. AC Systems PPM Schedule

ATTACHMENT A - STATEMENT OF WORK INVITATION TO BID FOR CHILLER INSPECTION SERVICES ITB NO.: DMS-13/14-035

6. Document tasks performed during visit and report any observations to the appropriate

COMPRESSORS REPLACEMENT PROCEDURE

Electric Duct Heater X X X X X X

Models & Options Lubrication. 1/2 Through 10 Hp Models 1Ø 3Ø 1/2 Through 10 Hp Models 1Ø and 3Ø

VTZ variable speed Reciprocating compressors

Fault Codes. J control

Air Handling Unit Construction Checklist

CENTRIFUGAL CHILLER. Lubrication System Pull oil sample for spectroscopic analysis.

CHILLER START UP PROCEDURE FORM DOC. N (DOC.N BELOW TO BE RETURN TO AERMEC)

Preventative HVAC Maintenance Proposal

Thermostatic Expansion Valve

TECHNICAL HANDBOOK. for MULTISPLIT NETWORK SYSTEMS OR GROUP CONTROL

Bitzer Friga Pack Catalogue

Page Number. Contents: Product Features 2. Physical Data 2. Nomenclature. 3. Blower Performance 3. Electrical Data 4. Warranty.. 6

"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

Copeland Screw TM Compressors

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers

EcoNet and Flash Codes

6,3 108 kw R410A UP FLOW DOWN FLOW !"#$% "&'("!%)*(% "&+*'*"&$(#%,*'-%($."'$%)*(% ""!$+% "&+$&#$(%"(%/0*!'1*&%,)'$(% ""!$+% "&+$&#$( RCGROUP SpA

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

Selection & Application guidelines. Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING

Component Coverage* A/C Presidential Plan. A/C Executive Plan $ $278

Roof Units. Specification. Construction. Performance. Impellers. Size range. Ancillary Equipment

EXHIBIT A SCOPE OF SERVICES MAINTENANCE OF TRANE HVAC SYSTEMS

CGA CXA VGA VXA CG-PRC006-E4

Extended Warranty for total peace of mind

INTERNATIONAL WARRANTY PROCEDURE. AUTOCLIMA S.p.A. PG-01-05

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

BOILER PM & INSPECTION

Maintenance Guide Rooftops

LCU DX Efficient cooling with no loss of space

Class II biological safety cabinets

Rotary Screw Compressors. L26RS Variable Speed

Ultima Compact Chiller Range kW

HC-IL.ESA.W l April Extended Service Agreement Program. For Heatcraft Refrigeration Products. Wholesaler/Contractor.

MAJORSELL. A/C Compressors AIR BRAKE PRODUCTS A I R B R A K E PRO D U CT S

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)

FRONTIER PITTS MAINTENANCE CONTRACTS

BC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat)

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Electric expansion valve stepper motor. Controller for elec. expansion valve Connector for controller expansion valve

Appendix A. Cooling Coil

SERVICE SCHEDULE. Zero-Turn Mowers

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

06/2014 INSTALLATION AND SERVICE INSTRUCTIONS. Compressor Units. for AeroMaster XP and AeroMaster Cirrus

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

FACT SHEET 12 Mobile air-conditioning

MANAGING NEW CONNECTIONS FOR YOUR BUSINESS

Air-Cooled Screw Chillers RTAF kw. The best bundled in one. Our best.

Compact Cooling Units

Innovative Engineering. Catalogue. Condenser. ECU, ECV and ECW Industrial Condenser Series. Technical Brochure

INSTALLATION AND OPERATION INSTRUCTIONS 4400QC SERIES POWER PAKS

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

Brief Overview 2018 WEH CONNECTOR SOLUTIONS for pressure-tight connections in seconds WEH Q UA LIT Y. since 1973

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

30GX AIR-COOLED LIQUID CHILLER

EX4 / EX5 / EX6 / EX7 / EX8 Electrical Control Valves

Mechanical Integrity (MI)

30GX AIR-COOLED LIQUID CHILLER

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Variable speed application guidelines

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

CWP-CO / CWP-RC / CWP-HP 02 to 35

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

PART 1 GENERAL. Pfannenberg Inc.

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge

Electric expansion valves Types AKVA 10, 15 & 20

Repair any problems or leaks before retrofitting. Affix labels to the vehicle showing conversion status. Observe all safety recommendations.

SARAVEL PACKAGED AIR-COOLED CONDENSING UNIT

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge

HUNTLEY COMMUNITY SCHOOL DISTRICT #158 Addendum No. 1 to Bid Specifications for HVAC Preventative Maintenance Services Bid #

A Practical Guide. to your Warranty Plus Plan for your Thermo King units

Danfoss Commercial Compressors Towards more eco-friendly commercial refrigeration systems

To determine if an A/C clutch should be returned for Warranty Consideration:

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls

Demystifying HVAC What To Do When They Cut Your Budget By Ron Prager

CWK Circular duct coolers for cooled water

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

Installation and Operating Manual

Air-Cooled Liquid Chiller with integrated hydraulic module

NOBEL FIXED SPEED from 5.5 to 37 kw NOBEL DV VARIABLE SPEED from 7.5 to 37 kw

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

an ISO 9001:2008 Registered Company 1964 CHEVY IMPALA WITHOUT FACTORY AIR REV C 7/8/14, 1964 IMPALA wo AC EVAP INST PG 1 OF 25

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil

Site Services. Asset Management for Modern Networks

kW. Ultima Screw Chiller Range kW. > Ultima Screw Chiller Range. Includes Ultima FreeCool Chiller Range

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A

Instruction Manual. Vibration Calibrator VC20. Manfred Weber. Metra Mess- und Frequenztechnik in Radebeul e.k. Meissner Str D Radebeul

SEMI-HERMETIC RECIPROCATING COMPRESSOR MULTIPLE COMPRESSORS UNIT WITH LEADING INVERTER COMPRESSOR ORIGINAL MANUFACTURED EQUIPMENT

Alfa Laval Optigo CS. Commercial air coolers - Slim line

Transcription:

Planned Preventative Maintenance Schedule Chilled Water Systems PPM Schedule

Planned and contracted maintenance services To ensure that data centre or building services are always operating to their full potential Workspace Technology recommends the deployment of regular planned preventative maintenance programmes which are backed up with emergency callout for unplanned failures. Workspace Technology engages specialist teams of service engineers operating throughout the UK. You can choose the level of service to match the business criticality. Support Plan Options Standard Premium Comprehensive Routine maintenance with access to our call-out service. All newly supplied products* *** covered within warranty period. As Standard, but inclusive of callout charges when newly supplied equipment is within the warranty period* Provides full service including call-out charges and equipment replacement both in and out of warranty** ***. * Equipment replacement costs when within their warranty period are inclusive. This excludes consumables, batteries and lamps/bulbs. ** Excludes consumables, batteries and lamps/bulbs. *** Excludes failures where the system has been damaged by users or third parties, or has a call out due to customer mis-operation. Damage due to poor quality water, fire, storm, flood or act of nature will be chargeable. Full details are in the contract terms and conditions.

Chilled Water PPM Schedule Frequency Two to Four checks per Year. Direct Expansion & Chilled Water Air-conditioning Air Handlers PPM Maintenance Service ELECTRICAL SECTION 1 Power down unit, check and tighten all electrical connections where possible. 2 Check and record mains voltage. 3 Check and record all voltages at all critical points in the electrical circuit including any transformed voltage. 4 Check and record all component running currents. 5 Examine data against previous information to establish any damaging trends. 6 Either correct or make recommendations in relation to any problems found in point 1 6. WATER SECTION (where applicable) 1 Check the whole fluid circuit for any leakage points where possible. 2 Check running pressure of pump(s). 3 Inspect and examine for any pressure drops around the systems. 4 Inspect fluid condition for any contamination. 5 Inspect any fluid filters in system and clean where applicable. 6 Examine new data against any previous data for trends. 7 Either correct or make recommendations in relation to any problems found in points 1 7.

REFRIGERATION SECTION 1 Carry out a full leak test of refrigeration circuit to comply with FGAS regulations. 2 Check and calibrate all pressure switches and alarm functions. 3 Check and calibrate all pressure gauges (where applicable). 4 Fit gauges and record operational pressures in all circuits. 5 Check expansion valve superheat and adjust as necessary. 6 Check and record system operating temperatures as required. 7 Carry out pump down test on each circuit to establish compressor performance (where applicable). 8 Examine refrigerant oil level in each compressor. 9 Check and record oil pressure (where applicable). 10 Check liquid line filter driers for blockage or contamination. 11 Clean the heat rejection condensers as necessary (remove and clean filters). 12 Check and record the system condensing and evaporating temperatures to establish system efficiency. 13 Check temperature rise across heat rejection coil to indicate correct air flow performance. 14 Examine new data against any previous data for trends. 15 Either correct or make recommendations in relation to any problems found in points 1 14. REFRIGERANT LEAK TESTING - EC REGULATION 842/2006 F GAS REGULATIONS 1 Systems containing HFC s (R134a, R404a, R407c, R410a, R22r) are subject to regulations as follows: 2 Systems that contain 3kg to 30kg charge must be leak tested annually. 3 Systems that contain 30kg to 300kg charge must be leak tested every six months. 4 After a leak has been repaired the plant must be rechecked within one month to ensure the repair has been effective (to be quoted for approval to proceed).

MICROPROCESSOR/ELECTRICAL CONTROL 1 Check all electrical terminations. 2 Examine alarm listing history and record where necessary. 3 Check and record compressor hours run times and adjust accordingly. 4 Check and calibrate all temperatures and pressure measurements. 5 Check and calibrate all temperature set points. 6 Either correct or make recommendations in relation to any problems found in points 1 5. REAR DOOR/IN ROW CHILLED WATER AHU s 1 Check and adjust off temperature (where necessary) and record. 2 Check and adjust fan speed (where necessary) and record. 3 Check operation of fans. 4 Reset all alarms and alarm timers. 5 Check condition of the door coils (and advise). 6 Check operation of valve and adjust if necessary. Record data. GENERAL SERVICE PLAN OPTIONS LEAK PREVENTION SYSTEM (WHERE FITTED) 1 Check pump pressures and current draw (adjust if needed). 2 Check heat exchanger where fitted for correct operation. 3 Check Venturi for correct pressure drop and operation (adjust if needed). 4 Check fluid level in tank. 5 Check Glycol strength in system and advise. GENERAL WORK 1 Clean down unit both internally and externally. 2 Repair any pipe work lagging found damaged. 3 Ensure all fixing screws are in place, replace where necessary. 4 Check for any excessive vibration on frame of pipe work. 5 Ensure all air intakes are free of any debris. 6 Ensure installation area is clean and safe on completion. 7 On completion, issue a full written report and give a comprehensive verbal report to customer, identifying any immediate recommendations needed along with longer term requirements. 8 Advise customer regarding any specific compressor maintenance that may be required in the mid to long terms. 9 Either correct or make recommendations in relation to any problems found in points 1 6.

Notes on Service Schedule All work mentioned in the schedule is carried out subject to Workspace Technology s Terms and Conditions of sale. The audit schedules shown are based on a standard and will not be applicable to every installation for every item listed. Consequently each task has to be qualified by the term; if it is safe so to do, if applicable, if possible and if appropriate. It is possible that your specific installation may have additional or specialised equipment not mentioned in this schedule. In that case, the specific equipment would be the subject of addenda to the main contract. Tasks mentioned in the schedule may also be omitted if Workspace Technology s engineers or its appointed agents deem that it is unsafe to carry out that task or that it may jeopardise the security of electrical supply. Approved Endorser EU Code of Conduct on Data Centre Efficiency APC Elite Partner Data Centre Certified Workspace Technology Limited Technology House, 5 Emmanuel Court, Reddicroft, Sutton Coldfield, West Midlands B72 1TJ. Tel : 0121 354 4894 Fax: 0121 354 6447 email : sales@workspace-technology.com www.workspace-technology.com Creating an effective workspace environment