Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Similar documents
User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Installation and Operation Back-UPS BX550CI-CN

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Installation and Operation Manual Back-UPS BX1100CI-CN

Installation and Operation Manual Back-UPS BR1000-CH

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

Installation and Operation Manual Back-UPS BR800/1100CI-IN

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

3000VA 120/208/230VAC

Installation and Operation Smart-UPS SUA500PDR

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Back-UPS CS Back-UPS CS 350

User Manual Back-UPS BE425M/425M-LM, BN450M/450M-CA

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

Uninterruptible Power System

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Operation Manual. English. APC Smart-UPS VA 3U Rack and Stack Uninterruptible Power Supply 230 Vac , Revision 1 12/00

Uninterruptible Power System

APC Smart-UPS RT UX. User s Manual. Models SURT1000UXI and SURT2000UXI 220/230/240 Tower/Rack Mount Uninterruptible Power Supply.

CP900EPFCLCD User s Manual K

User Manual. Smart-UPS. Uninterruptible Power Supply. 1000/1500 VA 100/120/230 Vac. 750XL/1000XL VA 120/230 Vac. Tower

SUA1000I-IN / SUA1500I-IN 230 VAC

Installation and Operation

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000 VA. 100/120/230 Vac. Rack Mount 1U

APC Smart-UPS 2200/3000 VA 230 VAC. Uninterruptible Power Supply

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

User s Manual. English. APC Smart-UPS RT. 3000/5000 VA VAC 3U Tower/Rack Mount Uninterruptible Power Supply

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Operation Manual. Smart-UPS C. Uninterruptible Power Supply 1000/1500/2000/3000 VA. 120/230 Vac. Tower. su0813a

POWERSTAR INC. Operations / Maintenance Manual Model: PS VA Tower UPS

Liebert PSA VA. Installer/User Guide

Allen-Bradley. User Manual for 3000/5000 VA UPS. Tower/Rack-Mount 3U Uninterruptible Power Supply

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Installation and Operation

Operation Manual. Smart-UPS. Uninterruptible Power Supply. Rack-Mount 1U. 1200/1500 VA 100/120/230 Vac

Uninterruptible Power System

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA Tower 100/120/230 Vac. 500 VA Tower 100 Vac

PR1000ELCD / PR1500ELCD User s Manual

Uninterruptible Power System

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

w w w.apc.com Home Appliance & Lighting UPS HI800SQ Installation Guide and User s Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual

Eclipse Plus VA UPS and Surge Suppressor User s Manual

Power Inverter. Model BI800T and BI800F. w w w.apc.com. Installation Guide and User s Manual

Installation Guide Smart-UPS X 2000/2200/3000 XL Tower/Rack-Mount 4U

MM-AVR UPS Series User s Manual

Uninterruptible Power Supply

SmartPro Medical-Grade UPS, Line Interactive, Lithium Battery, 6 Outlets - 230V, 1kVA, 750W, Full Isolation

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Operation Manual. Smart-UPS Uninterruptible Power Supply. 1000/1500/2200/3000 VA 220 Vac. Rack-Mount 2U

400 Watt Backup Power System Owner s Manual

APC Smart-UPS RT UXI/UXICH

Limousin II User Manual

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

User Manual. English. APC Smart-UPS. 7500/10000 VA VAC 6U Tower/Rack Mount Uninterruptible Power Supply B 02/2004

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

Operation Manual. Smart-UPS Uninterruptible Power Supply. Rack-Mount 2U. 750/1000/1500 VA 120/230 Vac VA 120 Vac. 100/120/208/230 Vac

User Manual Easy UPS On-Line SRV Series 1000VA, 2000VA, 3000VA

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Operation Manual. Smart-UPS Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA 100/120/230 Vac. 500 VA 100 Vac. Tower

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Sola/Hevi-Duty S3K Series Mini-Tower UPS

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Installation and Operation

Installation and Operation

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

User Manual Easy UPS On-Line SRVS Series Rack-Mount 1000VA, 2000VA, 3000VA

POWERWARE User s Guide VA.

Operation Manual. Smart-UPS. Uninterruptible Power Supply VA Short-depth Rack-Mount with Lithium-ion batteries. 120 Vac

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

User Manual Smart-UPS On-Line SRC1KI-IN, SRC1KUXI

Installation and Operation Manual Smart-UPS Tower 220/230/240 Vac SRC1000ICCIND; SRC1000UXIND

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

1. INTRODUCTION. Features:

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500 VA Short-depth Rack-Mount with Lithium-ion batteries.

Installation and Operation

Installation and Operation

USER MANUAL MPS 1-5KW SERIES

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

Pulsar EXtreme 2200C / 3200C

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Up to 98% efficient under full load Similar runtimes to the previous 3u model

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

User Manual 1KVA-5KVA INVERTER / CHARGER

Installation Guide Smart-UPS 1200/1500 VA 100/120/230 Vac Rack-Mount 1U

Liebert PowerSure PSI UPS

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

Transcription:

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit breaker USB port Tel/Network ports Input power outlet Battery and surge protected outlets bu204a Setup and Installation Connect the battery Pull the battery connector handle down, and then push it into the unit. Connect the equipment to Battery Backup+Surge Protection Outlets Connect equipment to the BATTERY BACKUP + SURGE PROTECTION outlets. These outlets provide backup power to the connected equipment during power outages. The Back- UPS must be turned ON in order to supply backup power. These outlets also provide protection to the connected equipment from power surges or spikes, even if the Back-UPS is turned OFF. Connect a computer, monitor, modem or other critical devices you want to stay powered during outages or utility problems into these outlets. Connect the power cord Connect the Back-UPS power cord to the outlet on the back of the unit and to a wall outlet. Do not connect the power cord to a surge protector or power strip. The outlet should be near the equipment and easily accessible. Connect the telephone cord Connect a phone line from the wall jack to the IN outlet on the UPS. Then, connect a phone, fax machine, or modem to the OUT outlet on the UPS using a phone cable.

Turn on the power to the unit Press the ON/OFF button on the front of the unit. The unit will emit a single, short beep and the green POWER ON indicator will illuminate to confirm that the unit is on and is providing power protection. To provide maximum runtime, the Back-UPS should charge for at least 10 hours. The unit is being charged whenever it is connected to utility power, even if the unit is OFF. PowerChute Personal Edition Software Overview Use PowerChute Personal Edition software to configure the UPS settings. Protect your computer and other equipment during a power outage. During a power outage, PowerChute will save any open files on your computer and safely shut it down. When power is restored, it will restart the computer. Configure the UPS to use features such as power-saving outsets, shutdown configuration, and alarms. Monitor the UPS for power usage and power events. Note: PowerChute is only compatible with a Windows operating system. If you are using a Mac OSX, use the native shutdown feature to protect your system. See the documentation provided with your computer. Installation Use a USB cable to connect the Data port on the rear panel of the UPS to the USB port on your computer. If the Back-UPS came with a PowerChute CD, insert the CD into your computer and follow the on-screen instructions If the Back-UPS did not come with a PowerChute CD, go to www.apc.com and download the software free of charge. Transfer Voltage and Sensitivity Settings Automatic Voltage Regulation This Back-UPS unit has Automatic Voltage Regulation (AVR). If the input utility voltage drops below a level that is safe for the operation of the connected equipment, the unit will boost utility voltage up to safe level. It will also compensate for high input utility voltage by lowering it to a level that is safe for the connected equipment. The Back-UPS will switch to battery power if the input voltage level becomes too low for the Automatic Voltage Regulation to compensate, or if the utility power is distorted. No-load Shutdown If the UPS is operating on battery power and detects that the connected equipment is using less than 15 W of energy for more than 15 minutes, it will shut down to conserve energy. When the UPS is reconnected to utility power, the UPS will automatically switch on. Note: Even if the UPS is OFF, it is still protecting connected equipment from power surges. 2

Adjust the settings If the Back-UPS switches to battery power too frequently or too infrequently, adjust the transfer voltage and sensitivity settings: 1. Ensure the battery is connected and that the Back-UPS is OFF, but connected to utility power. 2. Press and hold the ON/OFF button until the LED repeatedly flashes.the unit is now in Program Mode. 3. Release the button. The LED will indicate the current setting by flashing once, twice, or three times per, and emitting audible beeps. 4. Press ON/OFF within two s to change the setting. Continue pressing the button until the desired setting is reached. If the button is not pressed within five s, the Back-UPS will exit the Program Mode. LED Flashing Audible Indicator Transfer Voltage Setting Input Voltage Range No-load Shutdown Description Once per Once per Twice per Twice per Three times per Three times per None Low 140-300 Disabled The Back-UPS will switch to battery power less often. Use this setting for equipment that is not sensitive to low or high level voltage levels or minor voltage waveform distortions. 4 beeps per Low 140-300 Enabled The Back-UPS will switch to battery power less often. Use this setting for equipment that is not sensitive to low or high level voltage levels or minor voltage waveform distortions. None Medium 140-300 Disabled Use when the input utility power is normal, without any fluctuation in voltage levels. 4 beeps per Medium (factory default) 140-300 Enabled Use when the input utility power is normal, without any fluctuation in voltage levels. None High 150-290 Disabled The Back-UPS will switch to battery power during any small fluctuation in voltage. Use this setting for equipment that is sensitive to low or high level voltage levels or minor voltage waveform distortions. 4 beeps per High 150-290 Enabled The Back-UPS will switch to battery power during any small fluctuation in voltage. Use this setting for equipment that is sensitive to low or high level voltage levels or minor voltage waveform distortions. 3

Status Indicators LED Audible Alarm Condition On Off On-line - The Back-UPS is supplying utility power to the connected equipment Constant Tone On Line Overload - The power being used by the connected equipment has exceeded the capacity of the unit. Disconnect some equipment Constant beeping Over-temperature Warning - The unit is overheating and will shut down if the temperature is not lowered. Disconnect some of the connected equipment. On (Off during 4 beeps) Flashing Off 4 beeps repeated every 30 s Rapid Beeping (every 1/2 ) Constant tone Chirp every 2 s Short beep every 4 s Constant Tone Constant Tone Constant Tone On-Battery - The Back-UPS is supplying battery power Low Battery Warning - The Back-UPS has 2 minutes of runtime remaining Bad Battery Detected - The battery needs to be charged, or is at end of life. (See Battery Replacement.) Charger Warning - The Back-UPS has experienced an internal problem, but is still providing power to the connected equipment. Contact APC Technical Support Low Battery Shutdown - During On Battery operation the battery power was almost completely exhausted, and the Back-UPS is waiting for utility power to return to normal On Battery Overload - The connected equipment requires more power than provided by the Back-UPS battery. Unplug devices one at a time to remove overload. If the problem is not corrected, contact APC Technical Support Charger Fault - Back-UPS has an internal problem, and is no longer powering the load. Contact APC Technical Support Temperature Fault - The Back-UPS has overheated and has shut down. 4

Troubleshooting Problem Probable Cause Solution Back-UPS will not turn on. The circuit Breaker has tripped. Disconnect some of the equipment that is plugged into the BATTERY BACKUP + SURGE PROTECTION outlets. Reset the circuit breaker. Utility power is not available at the Check if the circuit breaker for the wall outlet has wall outlet. been tripped, if it has, reset the breaker. Connected equipment loses power. The Back-UPS is overloaded. Ensure that the equipment plugged into the unit is not overloading the capacity of the unit. Try disconnecting some of the equipment one device at a time, and see if the problem continues. The ON/OFF button is lit, and the unit is beeping four times every 30 s, or it is emitting a constant tone. Battery Replacement The Back-UPS has exhausted its available battery power. The unit can only operate on battery power for a limited amount of time. The unit will eventually turn off when the available battery power has been used. Allow the unit to recharge for 10 hours before continuing to use the unit. The equipment connected to the The output waveform is designed for computers Back-UPS does not accept the stepapproximated sine waveform from designed for use with motor-type equipment. and computer-related equipment. It is not the unit. The Back-UPS may require service. Contact APC Technical Support for further troubleshooting. The unit is using battery. The unit is operating normally and using battery power. Save any current work, turn off all equipment, and turn the unit OFF. Once normal power is restored, turn the unit back ON, and turn on all equipment. The On/Off button flashes once Battery capacity is low (there are The unit is about to shut down due to a low per ½, and the Back- UPS beeps once per at the same time. about 2 minutes of runtime remaining). battery charge condition. When the unit beeps once every, the battery has about 2 minutes of runtime remaining. Immediately power down your computer, and turn the unit OFF. When power returns to normal, the unit will recharge the battery. Inadequate runtime. The battery is not fully charged. Allow the unit to charge by leaving it plugged in, and switched on for 10 hours. The battery is near the end of useful life. As a battery ages, the amount of runtime available will decrease. Batteries also age prematurely if the unit is placed near excessive heat. If the battery will not charge, the Back-UPS is no longer operable. The battery in the Back-UPS 650 is not user-replaceable. Contact APC Sales and Technical Support for a list of authorized service centers near you. 5

Specifications Input Voltage 230 VAC nominal Frequency 45-65 Hz Brownout Transfer 140 VAC, typical Over-voltage Transfer 300 VAC, typical Output UPS Capacity (total) 650 VA / 390 W Voltage On Battery 230 Vac rms (step-approximated sine wave) Frequency - On Battery 50 Hz ±1 Hz, 60 Hz ±1 Hz Transfer Time 6ms typical Protection AC Surge Protection Full time, 273 joules and Filtering AC Input Resettable circuit breaker Battery Type (maintenance-free) 12V, 7.2 AH Average Life 2-5 years depending on the number of discharge cycles and environmental temperature Typical Recharge Time 8 Hours Physical Net Weight 6.2 kg Dimensions (H x W x D) 20 cm x 11.5 cm x 25.7 cm Operating Temperature 0 o C to 40 o C (32 o F to 104 o F) Storage Temperature -15 o C to 45 o C (5 o F to 113 o F) Operating Relative 0 to 95% non-condensing Humidity Operating Elevation 0 to 3000 m (0 to 10,000 ft) Service DO NOT RETURN Back-UPS to the place of purchase under any circumstances. 1. Consult the Troubleshooting section to eliminate common problems. 2. If you still have problems or questions, please contact APC via the internet or at one of the phone numbers listed below. 3. Before contacting APC, please be sure to record the date purchased, UPS model, and serial number (on bottom of unit). 4. Be prepared to troubleshoot the problem over the telephone with a Technical Support Representative. If this is not successful, the representative will issue a Return Material Authorization Number (RMA#) and a shipping address. 5. Pack the unit in its original packaging. If the original packaging is not available, ask APC Technical Support about obtaining a new set. Pack the unit properly to avoid damage in transit. Never use foam beads for packaging. Damage sustained in transit is not covered under warranty (insuring the package for full value is recommended). Write the RMA# on the outside of the package. Customer support and warranty information is available at the APC Web site, www.apc.com. 2010 APC by Schneider Electric. APC, the APC logo, and Back-UPS are owned by Schneider Electric Industries S.A.S., American Power Conversion Corporation, or their affiliated companies. All other trademarks are property of their respective owners. 990-3916-007 11/2010