DELTA HYDRO HOSE TESTER INSTRUCTIONS & MAINTENANCE MANUAL. READ and UNDERSTAND the Instructions below PRIOR to operating the DELTA HYDRO HOSE TESTER

Similar documents
DELTA HYDRO HOSE TESTER

DELTA HYDRO HOSE TESTER INSTRUCTIONS & MAINTENANCE MANUAL

Designed to quickly and safely test fire hose lines!!

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

Table of Contents WARRANTY

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

GARDEN HOSE UTILITY PUMP

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

Table of Contents WARRANTY

Low Profile J Series Power Unit with Vane Pump

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Operation and Maintenance. S100 Series Centrifugal Fire Pumps. Table of Contents. Visit us at F /22/02 6/21/18

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Manifold Isolation Valves

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

Pump Operating and Maintenance Manual - Models

WA 2719 ( 604 ) ( 604 ) , H.E.R.O.

LAWN SPRINKLER, IRRIGATION PUMP

OPERATION AND PARTS MANUAL

NECO Pumping Systems

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

Operating instructions Form no safety definitions

OWNER S MANUAL. Model: TR-40-GAS ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications

8650 Enterprise Drive, Peosta IA / Fax PARTS LIST FOR JP ME1/0ME3

DIRECT-DRIVE PRESSURE WASHERS

8650 Enterprise Drive, Peosta IA / Fax PARTS LIST FOR JP ME1/0ME3

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK

PLUNGER PUMP SERVICE MANUAL

S200-G Series Centrifugal Fire Pumps Operation and Maintenance Instructions

Operating Instructions & Parts Manual

LG-60-3PT-WP-309-BL-TSC

Air / Hydraulic Pump

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Page 1 of 19. Part# /10/2006

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

DIRECT-DRIVE PRESSURE WASHERS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

MODEL 25-OM-10-C & 25-OA-10-C HYDRAULIC BOOSTER

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

Heavy Duty Sprayer Owners Manual Model MS-O

PLUNGER PUMP SERVICE MANUAL

WORKHORSE. Assembly / Operation Instructions / Parts

( Versions Available)

S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

PARTS LIST FOR CA E2G CA E2G-W. Pump Oil Capacity: Nozzle Size: 4.0

JET SET OPERATOR S MANUAL J-1450

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

OPERATORS MANUAL for Electric Pressure Washers

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

AQUIS Foam System. Installation, Operation, and Maintenance Instructions AQUIS 1.5, AQUIS 3.0, and AQUIS 6.0

Installation & Operating Manual

DESIGNED BY EXPERIENCE PLASTIC SPHERE DISPENSER USER MANUAL. Manufactured by PSDS, Inc. for sole distribution by:

Athletic Field Painting Pointers Line Star Drawing Line Star Parts List 3-4. Spray Boom Drawing Stainless Steel Tank 6

IMPORTANT INFORMATION

OWNER S MANUAL Model: LG ( ) (25 Gallon Lawn & Garden Trailer Sprayer)

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

Page 1 of 12. Part# /30/2016

STYLE 3463 FireFox. With Position Feedback Potentiometer

180 Lake Ave North Paynesville, MN Phone: (320) MASTER MANUFACTURING MASTER GARDNER

ADJUSTING PRESSURE USING THE BOOM NOZZLES OPERATION

HL Series Centrifugal Fire Pumps Operation and Maintenance Instructions

Wash Prep Systems featuring CAT PUMPS DUPM623 DUPM820 / DUPM820-TS DUPM820D / DUPM820D-TS DUPM1010. Owner s Manual #

AUTOMATIC SUBMERSIBLE UTILITY PUMP

OPERATION MANUAL ESX-2

GHT-15 OPERATION AND MAINTENANCE MANUAL

PARTS LIST FOR CW ME3 (AFTER SERIAL # )

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN

HLP M10 HLP M10 (AFTER SERIAL # )

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

MODEL NO. LG Volt Lawn & Garden Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

PRESSURIZED DIATOMACEOUS EARTH FILTER SYSTEM

OWNER S MANUAL Model: LG ( ) (15 Gallon Lawn & Garden Trailer Sprayer)

BLACKMER BYPASS VALVES

The TR-Series are large volume,

TC Series Cooling Systems

Congratulations PRE-OPERATION SETUP

TECHNICAL DATA 1-1/2 (dn40)

1600 PSI ELECTRIC PRESSURE WASHER

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

Model No. LG55-3PT 55 Gallon Sprayer 3 Point Lawn & Garden Sprayer Model No. LG27-3PT 25 Gallon Sprayer GENERAL INFORMATION

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Operating and Installation Instructions

OWNER S MANUAL. ROTARY SURFACE CLEANER Models 105C, 105F, 105CW, & 105FW. Revision 2.01

Operation & Service Manual

Section 10 Chapter 17

Colt Series C400, C500

ESE Series Cast Iron Sewage Pumps

KLW4000D Multi-Port Power Pack

Transcription:

DELTA HYDRO HOSE TESTER INSTRUCTIONS & MAINTENANCE MANUAL READ and UNDERSTAND the Instructions below PRIOR to operating the DELTA HYDRO HOSE TESTER Failure to do so may result in BODILY INJURY or HOSE TESTER DAMAGE OUR COMMITMENT Niedner is committed to providing the highest quality of Customer Service! Our Customer Service is provided with warmth, friendliness, individual pride and Company Spirit. We acknowledge that to do well in a changing technological world we need to work in a climate of curiosity, adaptability, initiative and risk taking. We use our knowledge and experience to interpret your needs and pass on information. We are prepared to learn about your specific requirements and assist you with them to the best of our abilities. When we receive a request that we may not be able to accommodate, we will do our best to recommend an alternative method which may be of assistance to you. We take responsibility for what we do and how we do it. We use our resources wisely, ensuring that we provide the highest value for your investment. We acknowledge that we may make mistakes occasionally but we will learn from them and use this additional knowledge to further enhance our service to you. We value principles, such as honesty, courtesy, truthfulness and equity. Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 1

Table of Contents DELTA HYDRO HOSE TESTERS All models Page number INTRODUCTION 3 Hose Tester maintenance and Care General 4 Inspection 4 Lubrication 4 Filter Cleaning 4 Cautions 5 & 6 Hose Tester Operating Instructions Operating Instructions 6 9 Draining 9 Storage 10 & 11 Anti-freeze 10 & 11 Pressure Washer Operation Using the pressure washer equipment 11 13 Using the liquid injector 13 Questions & Answers / Hose Tester Trouble Shooting Slow pressurization 13 14 No pressure build up 14 15 Cloudy/White, milky pump oil 15 DELTA HYDRO Hose tester features chart 17 Parts list & Diagrams for all model hose testers 1500 Electrical series 18 & 19 2000 Electrical series Upright cart 20 & 21 2000 Electrical series Low profile cart 22 & 23 2000 Gas series Upright cart 24 & 25 2000 Gas series Low profile cart 26 & 27 Accessories for DELTA HYDRO hose testers (all models) 28 Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 2

INTRODUCTION Niedner s DELTA HYDRO hose tester is the only hose tester with both patented stainless steel manifold and automatic safety check valves. The stainless steel material used in the manifold contributes to an extended life by not deteriorating prematurely. Unlike other hose testers that have ball valves requiring hands-on operation during tests, the DELTA HYDRO hose tester has automatic check valves that create a safety margin for the operators during hose test pressurization. These check valves are fully automatic, allowing the operator to maintain a safe distance while testing hose. Niedner s greatest concern is that personnel may be struck by a burst hose line. Creating a safety perimeter will prevent this disaster. The automatic check valves on all DELTA HYDRO hose testers enhance this safety zone and minimize the chance of injury. DELTA HYDRO Hose Testers have the following high quality features: Reliable top quality oil bath pump for consistent performance, constant lubrication and long life. A powerful industrial motor as a power source on all the electric hose testers. Stainless steel construction for corrosion-free long life. Designed to meet or exceed NFPA 1962 guidelines. A one year limited warranty ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ DELTA HYDRO hose testers should be used by competent, trained personnel within the prescribed guidelines, as set forth by the manufacturer and NFPA. Failure of a DELTA HYDRO hose tester under pressure may cause serious bodily injury or property damage. Niedner disclaims any and all liability for injury or damage to any and all persons or property that may be caused by the operation of the DELTA HYDRO hose tester, whether it is a result of misunderstanding of instructions, lack of prudent safety precautions or not following the safety standards of the industry. All questions should be directed to your Niedner distributor or Niedner Inc. Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 3

DELTA HYDRO HOSE TESTER MAINTENANCE AND CARE (Part numbers and a visual of all accessories can be found on the last page of this manual) GENERAL: The DELTA HYDRO hose tester should be stored at room temperature. No water should be left sitting in the unit over long periods of time. INSPECTION: Before each use, your DELTA HYDRO hose tester is to be inspected as per NFPA 1962 (current edition). To inspect the check valve assemblies for possible corrosion and/or foreign matter, carefully dismantle the check valve assembly with your fingers and pull out the center disc. Visually inspect the condition of the O-ring on the center disc. If any of the O-rings are missing, cracked or damaged, they must be replaced. Replacement parts are available to you from your Niedner distributor (see parts list to obtain the part number to order). LUBRICATION: DELTA HYDRO hose testers have a break-in period of 50 hours of operation. After this period, the oil in the pump should be changed, and thereafter be changed after every 3 to 5 months or 200 hours of operation (whichever comes first). The proper oil level for all DELTA HYDRO hose tester models is in the middle of the sight glass or at the cut notch on the dipstick. IMPROPER PUMP LUBRICATION WILL VOID THE WARRANTY. Part # Source Motor oil recommended Pump oil recommended CDHT1500SS Electric Not applicable 5W-30 Synthetic CDHT2000SS Electric Upright Cart Not applicable 5W-30 Synthetic CDHT2000SS-LP Electric Low Profile Cart Not applicable 5W-30 Synthetic CDHT2000GA-SS Gas Upright Cart 10W-30 Synthetic 5W-30 Synthetic CDHT2000GA-SS-LP Gas Low Profile Cart 10W-30 Synthetic 5W-30 Synthetic For lubrication of the gasoline engine, refer to the gasoline engine manufacturer s manual. FILTER CLEANING: The DELTA HYDRO hose tester is equipped with an in-line water strainer for efficient operation. To clean this filter, unscrew the filter casing and remove the strainer inside. Flush thoroughly with water, or replace the in-line water strainer unit entirely if it is damaged or corroded (replacement parts are available from your Niedner distributor see parts list and schematic diagram to locate this part and acquire the correct part number to order). Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 4

CAUTIONS 3 inch (76mm) and/or larger diameter hose: All hoses 3 (76mm) and larger shall be tested flat on the ground with the use of lead lines. Lead lines are short, smaller diameter sections of hose, placed between the tester and the sections of larger hoses being tested (lead lines are available from your Niedner distributor). No sections of large diameter hose (LDH) should ever be connected directly to the DELTA HYDRO hose tester check valves. The weight of a water-filled LDH may damage the manifold. Pump Heat Build-up: The DELTA HYDRO hose tester is equipped with a positive displacement oil bath pump. An oil bath pump normally runs cooler than other types of pumps; however care must still be taken. While the pump is operating, the pressure regulator directs water back into the inlet side of the pump creating a closed loop re-circulating action. This causes heat to build up inside the pump. Caution must be used to prevent the pump temperature from exceeding 160 F (71 C). Once the desired test pressure is reached, the pump should be turned off, allowing the check valves to hold the pressure for the allotted time specified by NFPA. *** HEAT DAMAGE WILL VOID THE WARRANTY *** Inlet water pressure: Inlet water pressure should not exceed 120 PSI (827 kpa) or nonwarrantied internal damage to the pump can occur. Safety Tie Lines: Properly tying the hoses together at every coupling connection with the designed safety tie-line will secure the hoses together for stability and safety in case of hose failure. (Safety tie lines are available from your Niedner distributor). Gas Engine DELTA HYDRO Hose Testers: Running the gas model DELTA HYDRO hose tester at full throttle speed is not required or recommended. The throttle setting/speed should be half speed or slightly higher. Using the sound of the engine as a guide, strive for a smooth vibration-free operation. Excessive vibration will reduce the life expectancy of the DELTA HYDRO hose tester and could cause damage/or breakage to tester parts. Electrical Extension Cords: The use of an electrical extension cord, with any of the electric DELTA HYDRO hose tester models, is not recommended. However; should one be required, it is essential that the extension cord is properly sized and of the appropriate amperage rating for the electric motor. Use of inappropriate amperage rated electrical extension cord may cause nonwarranty damage to the motor. Water: NEVER RUN THE PUMP WITHOUT AN ADAQUATE WATER SUPPLY Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 5

Maximum safety: Be sure to carefully read, understand and follow all instructions in this manual as well as the NFPA 1962 (current edition). Personnel safety is the first priority in all hose testing evolutions. Returns: Any and all returns must have an authorization number approved by Niedner Inc. All liquids are to be removed from the hose tester prior to shipping. Any DELTA HYDRO hose tester being shipped with flammable liquids must have the appropriate MSDS sheets included with the shipment paperwork. Niedner must be advised of this prior to shipment or product pick up. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ DELTA HYDRO Hose Tester Operating Instructions (NOTE: become thoroughly familiar with these instructions & Maintenance Manual as well as the NFPA 1962 (current edition) PRIOR TO operating the DELTA HYDRO hose tester) 1. Position the DELTA HYDRO hose tester on a hard, flat and stable surface. If the test site has any incline, place the hose tester at the lowest part of the incline, with the hose discharge ends at the highest position. It must be placed so it is NOT tilted more than 10 degrees off vertical. This will help all air to be expelled from the hose. NOTE: All hose being tested together must be of the same Service Test Pressure. 2. Checking fluid levels: Electric Model testers Gas Model testers Check the oil levels in the pump. Check the oil levels in the pump Check the fuel in the gas engine Check the oil levels in the gas engine 3. Connect the sections(s) of hose(s) being tested to the hose tester outlets. Cap off any unused check valve outlet with the appropriate size OPEN bleed cap and NOT a BLIND cap. The maximum footage PER OUTLET should not exceed 300 feet. Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 6

WARNING: For more efficient time management, Niedner recommends attaching hose 3 or larger to the bottom outlet(s) only. Lead lines are to be used for testing hoses 3 or larger. Lead lines must have the same or greater service pressure rating than hose(s) being tested. Large diameter hose should NEVER be attached directly to any DELTA HYDRO hose tester check valve. 4. Attach bleed caps to all the test hose discharge ends. Make sure the petcock valve on the bleed cap is in the open position. All hoses are to be tied together at the coupling connection with a safety tie line per NFPA 1962 (current edition). The use of the safety tie lines is for safety reasons. Having the hoses tied together will minimize the chance of injury should a hose burst while pressurized. 5. Connect the DELTA HYDRO hose tester to the water supply of your choice. The inlet water pressure should not exceed 120 PSI. Surpassing this pressure could cause non-warranty internal damage to the pump. 6. For the electric model DELTA HYDRO hose tester, be sure to plug the tester into a grounded 20 amp circuit. If an extension cord is required, please refer to the notation on extension cords located on page 5 of this manual. 7. Open both ball valves on the DELTA HYDRO hose tester and turn the water supply on. Allow the water to flow throughout the tester until all the air has been evacuated from the unit. When there is a steady stream of water being expelled from the sections of hose, close the bleed caps by turning the petcock valve in the opposite direction. 8. Close the main water supply inlet ball valve. DO NOT SHUT OFF THE WATER SUPPLY. 9. Closing the inlet ball valve redirects the water supply through the pump. A continuous supply of fresh water flowing into the pump will keep it from overheating. Shutting off the water supply during operation could damage the pump and cause non warranty damage to your DELTA HYDRO hose tester unit. 10. It is normal to see water being expelled from the thermal relief valve. CAUTION: This water will be HOT. The function of the thermal relief valve is to remove the heated water from the pump to allow room for the cooler water from the main water supply. 11. At this point the hoses are filled and are completely purged/bled of air. The gauge on the hose tester should show a reading from 50 PSI to 120 PSI hydrant pressure. If the gauge needle has NOT moved from its original position, STOP the tester; as the gauge may be damaged, broken or faulty. If the gauge is functional, skip to step 14. Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 7

12. Do not resume using the DELTA HYDRO hose tester unit until it has been inspected by a trained mechanic and/or the non-functional gauge has been replaced. (Replacement gauges are available from your Niedner distributor see your tester model schematic and parts list for confirmation of which part to order). 13. Make sure the pressure regulator is set at the minimum pressure before starting up the DELTA HYDRO hose tester. The minimum setting is achieved by turning the pressure regulator in the counter clockwise direction. 14. Start up the DELTA HYDRO hose tester and slowly turn the handle of the pressure regulator in a clockwise direction until the desired test pressure is indicated on the gauge. DO NOT force the handle of the pressure regulator beyond its normal resistance point. If the gas model DELTA HYDRO hose tester is being used, the engine should be run at a smooth consistent throttle speed (half speed or slightly higher). Use the sound of the gas engine as a guide to strive for a smooth, vibration free operational throttle. Excessive vibration will reduce the life expectancy of the DELTA HYDRO hose tester. 15. The pressurization time will vary, this process may take anywhere from 20 to 30 minutes, or longer, depending on the size, type and quantity of hose being tested. Also, the diameter of the water supply hose may contribute to a longer fill time. However, the inlet of the water supply hose should be of the same or greater diameter size as the inlet of the hose tester. ** WARNING: The pump should never be started or run without an adequate supply of water flowing through the pump plumbing and the DELTA HYDRO hose tester manifold. Damage to equipment, personnel injury, or death may result if the pump is operated without an adequate water supply. 16. Once all lengths of hose have successfully been tested, return the handle of the pressure regulator to its original positioning (completely counter-clockwise direction). It is IMPORTANT to turn off the DELTA HYDRO hose tester BEFORE turning off the main water supply. Shutting off the water supply while the pump is still operating may result in non-warranty damage to the hose tester unit or other equipment or may cause serious personnel injury. 17. Open all the bleed caps by turning the petcock in the appropriate direction in order to relieve the water pressure from the hose. Remove the bleed caps, safety-tie lines and lead lines (if applicable) and store everything in the appropriate location. Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 8

18. To remove the maximum amount of water from the DELTA HYDRO hose tester prior to storage, slowly tip the hose tester unit forward until all water is removed from the manifold; the lower check valves should be blocked open during this process. 19. DELTA HYDRO hose tester units which are frequently subject to salt water or brackish water conditions should be FLUSHED with CLEAN FRESH water after each use. 20. Also, DELTA HYDRO hose tester units which are used in salt water or brackish water conditions should be equipped with special ordered BRASS check valve assemblies. The brass check valves are available to you from your Niedner distributor. 21. Unless otherwise specified, the DELTA HYDRO hose tester comes equipped with Aluminum check valve assembly. Niedner disclaims any and all liability for injury or damage to any and all persons or property that may be caused by the operation of the DELTA HYDRO hose tester, whether it is a result of misunderstanding of the instructions, lack of prudent safety precautions or not following the safety standards of the industry. DRAINING THE HOSE TESTER AFTER A SERVICE TEST FLUSHING: If salt water or brackish water has been used, flush the hose tester and the pressure washer equipment thoroughly with fresh water after each use. Remove all bleed caps and store separately. DRAINING: To drain the water from the DELTA HYDRO hose tester, use a small screwdriver and your fingers to carefully pull out the center disc of one of the bottom check valve outlets. Carefully insert the screwdriver behind the center disc to keep the check valve open. Then, gradually tilt the hose tester forward, until all water has drained; being very careful that oil DOES NOT leak from the dipstick opening. Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 9

Short term and Long term storage of the DELTA HYDRO hose tester Short term storage (up to 3 months): In ABOVE freezing weather conditions: drain the water from the hose tester by following the above steps. As an additional measure, blow low pressure compressed air through the open water inlet valve to remove the remainder of the water from the inside of the unit. Long term storage (+ 3 months): In BELOW freezing weather conditions: drain all the water from the unit using the above steps, and blow low pressure compressed air through the open water inlet valve to remove the remainder of the water from the inside of the unit. Cap the check valves to prevent entry of foreign material. An inspection of the in-line straining unit should be made. This can be done by unscrewing the joint of the in-line strainer (DEL-1181). If damage is found, the in-line strainer must be replaced. ANTI-FREEZE: In colder climates, extra steps are required. Niedner recommends the following steps be taken to protect and prolong the life of your DELTA HYDRO hose tester: The pumps water way should be filled with a solution made up of 50% water and 50% ethylene glycol anti-freeze. Follow these steps: Close the inlet ball valve. Using bleed caps, cap off all but one of the check valves on the unit: Recommended: If you have a 1500 model hose tester, leave the top outlet uncapped. If you have a 2000 model hose tester, leave one of the two top outlets uncapped. Carefully insert the head of a small screwdriver into the un-capped check valve as described previously in the section Draining the hose tester after a service test. This will allow the air to escape as you are filling the unit with the anti-freeze mixture. Attach a 3 foot (0.9 m) piece of garden hose with a female GHT (garden hose thread) to the in-line Water Strainer connection. With a funnel in the garden hose, slowly pour in the anti-freeze mixture (50% water and 50% ethylene glycol anti-freeze) into the unit until full, at which time the anti-freeze mixture will seep out from the uncapped check valve opening. When the anti-freeze mixture seeps through the check valve, remove the small screwdriver and cap of the check valve. Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 10

Remove the funnel and clamp off the open end of the garden hose, so that it will not leak during storage. The water inlet can be capped off with the appropriate size fitting if the garden hose needs to be removed for storage. ************************************************************** All testing should be done in accordance to NFPA 1962 most current edition. It is the user s responsibility to ensure they are using the correct version prior to commencing their testing. Verification or purchase of the current NFPA edition can be done through the NFPA web site. Simply google: NFPA1962: standard for the care, use, inspection, service testing and replacement of fire hose, couplings, nozzles and fire hose appliances. ************************************************************** Using the pressure washer equipment All DELTA HYDRO hose testers can be used with optional pressure washer equipment. This accessory can be purchased from your Niedner distributor (see back cover for part codes and information). The pressure washer will clean dirt from equipment without peeling decals. When used at a lower pressure setting, it can also be used to remove the dirt & debris from hose without damaging the fabric of the jacket. The pressure washers are rated by PSI: the greater the PSI reading = the lower the water flow, the higher the PSI reading = the more air is generated into the water flow. DELTA HYDRO hose testers are equipped with a dedicated outlet for pressure cleaning. The feed line must be capable of supplying at least 5 GPM to the pressure washer. The pressure pump will not self-prime nor should it be gravity fed. Using a gravity fed line may result in pump damage and void the warranty. Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 11

Connecting the pressure washer equipment to the DELTA HYDRO hose tester Older model DELTA HYDRO hose tester units were not built with the hardware required for attaching the pressure washing equipment. In such cases, the appropriate parts are available to you from your Niedner distributor. Parts required for converting your older tester for pressure washer use: Part number Description Quantity required DEL-1058 BRASS 3 CONNECT TEE 3/8 1 DEL-2050 HEX PIPE NIPPLE 3/8" 1 DEL-1087M QUICK CONNECT MALE 1 If your DELTA HYDRO hose tester is equipped with the male quick connect, attaching the pressure washer equipment is easy. Install the appropriate sized bleed caps on all the check valve assemblies. Connect the water source to the hose tester inlet ball valve. Turn on the water supply and bleed all the air from the unit. Close the inlet ball valve and the ¼ inch ball valve. By closing the ¼ inch ball valve, you are redirecting the water from the manifold to the pressure washer equipment. Start the pump then adjust the pressure by turning the pressure regulator in the appropriate direction. DO NOT FORCE the pressure regulator past its resistance point. All electric model testers are locked at 500 PSI and the gas model tester is locked at 600 PSI. Tampering with the pressure regulator to obtain higher pressure will void all warranty and may cause injury to personnel. The water spray from the pressure washer gun can be adjusted by simply turning the HI/LOW tip nozzle in the appropriate direction. Water up to 140 F (60 C) may be used; HOWEVER, extreme caution must be exercised to avoid heat damage or bodily burns. With the pump on, do not keep the pressure washer in closed or in the off position for more than one (1) minute when using hot water. If it becomes necessary to shut off the motor during operation, it will be necessary to relieve the high pressure prior to attempting to restart. The electric motors WILL NOT START against the high pressure build-up. Relieve the pressure by: Momentarily opening the 1/4 ball valve (located on the manifold) to reduce the pressure in the pressure washer equipment, or Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 12

Squeeze the trigger of the pressure washer gun several times. Using the liquid injector with the pressure washer equipment: The liquid injectors used with the DELTA HYDRO hose tester pressure washers are LOW PRESSURE injectors. The pressure must be reduced before the injector will operate. This is achieved by turning the HI/LOW tip nozzle of the spray gun nozzle in the appropriate direction. While holding the pressure washer gun in the downwards position, turning the nozzle tip in a counterclockwise direction (or to the left) will inject the liquid. Turning the tip in a clockwise direction (or to the right) will stop the injection of the liquid. The purpose of the liquid injector is to soap down the project, and then turn the nozzle back to high pressure for wash down. When first used, the nozzle may need to be cycled back and forth from high pressure to low pressure several times. *** THOROUGHLY RINSE ALL PRESSURE WASHER PARTS AFTER USE *** *** NEVER RUN THE HOSE TESTER PUMP WITHOUT WATER *** Questions & Answers DELTA HYDRO Hose Tester Trouble Shooting Q: Why does it take so long for the hose to pressurize? A: Pressurization can be a time consuming process and should not be rushed! It is normal for the pressurization procedure to take anywhere from 15 to 20 minutes or longer depending on the type, diameter, and quantity of hose being tested. However, it is also due in part to a designed safety feature. The hose is pressurized through a 1/4 inch high pressure hose which leads from the pump to the manifold. This small diameter hose restricts the volume of water being transferred, thus reducing the risk of a hose whipping uncontrollably should there be a burst line or coupling separation during testing. ** Consider this: A pump from a fire truck unit can easily deliver 250 GPM to 1000 GPM (depending on the make and model), whereas the pump from the CDHT1500SS tester delivers 3.2 GPM and the pump on the CDHT2000SS Electric tester delivers 4.2 GPM. Because the pumps on the DELTA HYDRO hose testers are significantly smaller, the pressurization time will be longer. Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 13

However, by using the DELTA HYDRO hose tester (in accordance with this manual and the NFPA 1962 (current edition) guidelines) the advantages are threefold: first, you have not taken a fire truck out of service to perform your annual hose testing operations; second, you are not putting extra wear on your apparatus motor, pump and valves; third, due to the mobility of the testers, hose testing can be performed at any location which has the required water supply and appropriate unobstructed space as described herein. Q: Why won t my DELTA HYDRO hose tester build up pressure? A: Double check the following pressurizing settings: The inlet ball valve is CLOSED. The water supply is TURNED ON. The water supply is not restricted and has adequate pressure. The 1/4" ball valve is OPEN. There are no leaks in the hose. There is no air remaining in the hose tester unit. Additionally, check the following on the DELTA HYDRO hose tester unit: 1) OPEN the 1/4" ball valve (valve is to remain open unless pressure washer equipment is being used) 2) REMOVE all hose from the hose tester 3) Cap off all the check valves with the appropriate sized bleed caps. 4) Turn the water supply ON 5) CLOSE the main water supply inlet ball valve. 6) Bleed the air from the manifold 7) With the pressure regulator set at the minimum setting (full counter-clockwise), turn the pump on and SLOWLY raise the pressure. 8) Within a very few seconds, the pressure should build up to a 400 to 500 PSI range. 9) If the pressure gauge needle does not move, STOP the pump immediately and remove all the water from the hose tester. You must replace the gauge before resuming the use of your tester. Replacement parts can be ordered from your Niedner distributor see parts list for appropriate part number. Checking the pressure in the manifold: Use an in-line gauge to check if there is adequate pressure in the manifold. To do so, attach a separate pressure gauge to the appropriate sized adapter and attach this adapter to one of the TOP check valve outlets on the manifold of your DELTA HYDRO hose tester. Cap off the remaining check valves with the appropriate sized bleed caps. Carefully repeat steps 4 through 9, this time observe the readings from BOTH pressure gauges. If the in-line gauge shows a reading, but the gauge on the hose tester does not, it is likely that the pressure gauge on the tester is faulty. DO NOT continue using the hose tester until the faulty gauge has been replaced. Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 14

If the pressure builds up on either gauge, this means that the DELTA HYDRO hose tester is operating properly. There is one more step which can be taken to verify the function of the pressure gauge. W A R N I N G: The step below must be performed by a trained mechanic: Improper replacement of the poppet valves could cause irreparable damage to the pump. It is imperative that this repair be completed by a trained mechanic. The pressure could be restricted due to the poppet valve located within the pump. If the poppet valves are clogged, broken or dysfunctional, they will need to be replaced before reusing the DELTA HYDRO hose tester. Replacement parts can be ordered from your Niedner distributor see parts list for appropriate part number. Replacement of the Poppet Valves: To replace a poppet valve, unscrew each brass poppet valve cap from the pump. Carefully remove the poppet valve from its socket with a pair of needle nose pliers. Each poppet valve must be visually inspected and tested to ensure that the spring mechanism functions properly. If the spring mechanism moves freely inside the poppet valve when pushed inwards, without applying too much force with the end of the needle nose pliers, it is functioning properly. If the spring is rusted or damaged, the entire poppet valve must be replaced. Once all the poppet valves are inspected, repaired or replaced, re-assemble the pump by reversing the above steps. Q: Why does the oil in the pump appear to be white/cloudy or milky? A: There are a few reasons why the oil in the pump may appear this color. The first of which may be water leaking into the oil. This is likely caused by damaged or worn packing rings. To order a replacement packing kit from your Niedner distributor, you must provide the following information: 1) The DELTA HYDRO hose tester serial number. This number is on a black tag located at the back and on the cart of the hose tester. The serial number begins with HT-02... 2) Specify the model number and the manufacturing company of the pump. This information is usually located on the underside of the pump. This information ensures that the correct packing kit is ordered as they differ depending on pump manufacturer. If you continue having problems with your DELTA HYDRO hose tester, please contact Niedner Inc. s customer service department between 8am & 4:30pm EST Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 15

N O T E S Niedner recommends that you write down the following information for future reference: Niedner distributor whom you purchased your DELTA HOSE tester from: Distributor telephone number: DELTA HYDRO Hose tester model number: CDHT DELTA HYDRO Hose Tester serial number: HT-02 Purchase date: Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 16

DELTA HYDRO HOSE TESTER PARTS LIST AND SCHEMATIC DRAWINGS CDHT1500SS CDHT2000SS-LP CDHT2000GA-SS-LP CDHT2000SS CDHT2000GA-SS Model Power Pump Motor Cart Style Manifold size Number of outlets Inlet & Outlet size Wheels 1500 115v Electric 3.2 GPM 1.7 HP / 60Hz Low profile 1.5 4 1.5 4 x 5 2000 115v Electric 4.3 GPM 1.7 HP / 60Hz Low profile 2.0 6 2.5 4 x 5 115v Electric 4.3 GPM 1.7 HP / 60Hz Upright 2.0 6 2.5 2 x 8 Gasoline 5.6 GPM 5.5 HP Low profile 2.0 6 2.5 4 x 5 Gasoline 5.6 GPM 5.5 HP Upright 2.0 6 2.5 2 x 8 ALL DELTA HYDRO Hose Testers are compliant with the NFPA 1962 (current edition) and come STANDARD with: A one year limited warranty Durable stainless steel car and manifold Industrial type motors Maximum pressure of 500 PSI (all electric models) and 600 PSI on the gas model Male quick connect for optional pressure washer equipment Oil bath pump with thermal protective valve In-line water filter system Fully automatic aluminum check valve assembly (brass assemblies also available at extra cost) Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 17

DIAGRAM / SCHEMATIC Niedner Inc. DELTA HYDRO Hose Tester Model #CDHT1500SS P A R T S L I S T No. Quantity Part Number Description 1 1 CA3500015B15B 1.5 NH (NST) x 1.5 NH (NST) DSW Female 3 4 DEL-51001 Check Valve Assembly 1.5NH (NST) (Hose tester serial number required to purchase this part) 9 1 DEL-1014 Manifold 1500 (Hose tester serial number required to purchase this part) 10 1 DEL-1121 Motor 1.7 HP / 60 Hz 11 1 DEL-1024 Pump 3.2 GPM 12 1 DEL-1032 Inlet Nipple 1.5 NH-NPT 13 1 DEL-1034 Ball Valve 1/4" 14 1 DEL-1037 Ball Valve 1.5 15 1 DEL-1039-01 Gauge 1000 PSI BACK Connection 16 1 DEL-1041/21 120 Volt electric cord 17 1 DEL-1042 Toggle Switch 18 1 DEL-1043 Toggle Switch Boot 19 1 DEL-1045-14-3 Strain Relief Connector 20 4 DEL-1049 5 Caster Wheels 21 1 DEL-1052 Street Elbow 1/4" - 90 22 3 DEL-1055 Street Elbow 3/8" - 90 23 1 DEL-1056 Adapter 1/2" - 45 24 1 DEL-1062 Pressure Regulator (unloader) Testers purchased prior to May 9, 2013 will also require 1 x DEL-1098. Reducer with ¼ is no longer available 25 1 DEL-1064 Hose 3/8 x 18 26 1 DEL-1066 Hose 1/2 x 15 27 1 DEL-1067 Hose 1/2 x 18 28 1 DEL-1068 Brass 3 Connect Run Tee 1/2" 33 1 DEL-1087M Quick Connect Male 34 1 DEL-1098 Reducer 1/2" Female x 3/8 Male 35 1 DEL-1120 Thermal Relief Valve 36 1 DEL-1009 Stainless Steel Low Profile Cart 37 1 DEL-1138 1/4" Hex nipple 38 1 DEL-1181 In Line Strainer Unit 39 2 DEL-2050 Hex Pipe Nipple 3/8 Not shown 1 DEL-1046-120V GFCI Module 120V Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 18

DIAGRAM / SCHEMATIC Niedner Inc. DELTA HYDRO Hose Tester Model #CDHT1500SS Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 19

DIAGRAM / SCHEMATIC Niedner Inc. DELTA HYDRO Hose Tester Model #CDHT2000SS (electric upright cart) P A R T S L I S T No. Quantity Part Number Description 1 1 CA3500020B25B 2 NH (NST) x 2.5 NH (NST) DSW Female 3 6 DEL-52002 Check Valve Assembly 2.5NH (NST) (Hose tester serial number required to purchase this part) Manifold 2000 (Hose tester serial number required to purchase this part) 9 1 DEL-1015 10 1 DEL-1121 Motor 1.7 HP / 60 Hz 11 1 DEL-1033 Inlet Nipple 2 NH 12 1 DEL-1034 Ball Valve 1/4" 13 1 DEL-1036 Pump 4.3 GPM 14 1 DEL-1038 Ball Valve 2 15 1 DEL-1041/21 120 Volt electric cord 16 1 DEL-1045-14-3 Strain Relief Connector 17 1 DEL-1042 Toggle Switch 18 1 DEL-1043 Toggle Switch Boot 20 2 DEL-1051 8 Wheels 21 3 DEL-1052 Street Elbow 1/2" - 90 22 2 DEL-1055 Street Elbow 3/8-90 23 1 DEL-1058 Brass 3 Connect Tee 3/8 24 1 DEL-1062 Pressure Regulator (unloader) Testers purchased prior to May 9, 2013 will also require 1 x DEL-1098. Reducer with ¼ is no longer available 25 1 DEL-1064 Hose 3/8 x 18 26 2 DEL-1066 Hose 1/2 x 15 27 1 DEL-1068 Brass 3 Connect Run Tee 1/2" 30 2 DEL-1076 Wheel push cap 32 1 DEL-1087M Quick Connect Male 33 1 DEL-1098 Reducer 1/2" Female x 3/8 Male 34 1 DEL-1120 Thermal Relief Valve 35 1 DEL-1039-01 Gauge 1000 PSI BACK Connection 36 1 DEL-1138 1/4" Hex Nipple 37 1 DEL-1012 Stainless Steel Upright Cart 38 2 DEL-9283 Plastic cap for legs 39 1 2 DEL-1013-01 DEL-0002 Stainless Steel face plate Face Plate Bracket 40 1 DEL-1181 In-Line Strainer unit 41 2 DEL-2050 Hex Pipe Nipple 3/8 43 2 DEL-1107 55-59 mm Clamp 44 2 DEL-1025 Lower Bracket 45 2 DEL-2053 45 Elbow 1/4" NPT Not shown 1 DEL-1046-120V GFCI Module 120V Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 20

DIAGRAM / SCHEMATIC Niedner Inc. DELTA HYDRO Hose Tester Model #CDHT2000SS (electric upright cart) Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 21

DIAGRAM / SCHEMATIC Niedner Inc. DELTA HYDRO Hose Tester Model #CDHT2000SS-LP (electric low profile cart) P A R T S L I S T No. Quantity Part Number Description 1 1 CA3500020B25B 2 NH (NST) x 2.5 NH (NST) DSW Female 3 6 DEL-52002 Check Valve Assembly 2.5NH (NST) (Hose tester serial number required to purchase this part) 9 1 DEL-1015-51 Manifold 2000 (Hose tester serial number required to purchase this part) 10 1 DEL-1121 Motor 1.7 HP / 60 Hz 11 1 DEL-1033 Inlet Nipple 2 NH 12 1 DEL-1034 Ball Valve 1/4" 13 1 DEL-1036 Pump 4.3 GPM 14 1 DEL-1038 Ball Valve 2 15 1 DEL-1039-01 Gauge 1000 PSI BACK Connection 16 1 DEL-1041-21 120 Volt electric cord 18 1 DEL-1042 Toggle switch 19 1 DEL-1043 Toggle switch boot 20 1 DEL-1045-14-3 Strain Relief connector 21 4 DEL-1049 5 Caster wheels 22 3 DEL-1052 Street elbow 1/2" - 90 23 2 DEL-1055 Street elbow 3/8-90 24 1 DEL-1058 Brass 3 Connect Tee 3/8 25 1 DEL-1062 Pressure Regulator (unloader) Testers purchased prior to May 9, 2013 will also require 1 x DEL-1098. Reducer with ¼ is no longer available 26 1 DEL-1064 Hose 3/8 x 18 27 2 DEL-1066 Hose 1/2 x 15 28 1 DEL-1068 Brass 3 Connect Run Tee 1/2" 32 1 DEL-1087M Quick Connect Male 33 1 DEL-1098 Reducer 1/2" Female x 3/8 Male 34 1 DEL-1109 Stainless Steel low profile cart 35 1 DEL-1120 Thermal Relief Valve 36 1 DEL-1138 1/4" Hex Nipple 37 1 DEL-1181 In-Line Strainer unit 38 2 DEL-2050 Hex Pipe nipple 3/8 Not Shown 1 DEL-1046-120V GFCI Module 120V Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 22

DIAGRAM / SCHEMATIC Niedner Inc. DELTA HYDRO Hose Tester Model #CDHT2000SS-LP (electric low profile cart) Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 23

DIAGRAM / SCHEMATIC Niedner Inc. DELTA HYDRO Hose Tester Model #CDHT2000GA-SS (gas upright cart) P A R T S L I S T No. Quantity Part Number Description 1 1 CA3500020B25B 2 NH (NST) x 2.5 NH (NST) DSW Female 3 6 DEL-52002 Check Valve Assembly 2.5NH (NST) (Hose tester serial number required to purchase this part) Manifold 2000 (Hose tester serial number required to purchase this part) 9 1 DEL-1015 10 1 DEL-1022 Motor 5.5 HP Honda 11 1 DEL-1033 Inlet Nipple 2 NH 12 1 DEL-2033-ASSEM Pump assembly 5.6 GPM 13 1 DEL-1034 Ball Valve 1/4" 14 1 DEL-1038 Ball Valve 2 15 2 DEL-1051 8 Wheels 16 2 DEL-1052 Street Elbow 1/2" - 90 17 2 DEL-1055 Street Elbow 3/8-90 18 1 DEL-1058 Brass 3 Connect Tee 3/8 19 1 DEL-1062 Pressure Regulator (unloader) Testers purchased prior to May 9, 2013 will also require 1 x DEL-1098. Reducer with ¼ is no longer available 20 1 DEL-1064 Hose 3/8 x 18 21 2 DEL-1066 Hose 1/2 x 15 22 1 DEL-1068 Brass 3 Connect Run Tee 1/2" 26 2 DEL-1076 Wheel push cap 28 1 DEL-1087M Quick Connect Male 29 1 DEL-1098 Reducer 1/2" Female x 3/8 Male 30 1 DEL-1120 Thermal Relief Valve 31 1 DEL-1039-01 Gauge 1000 PSI BACK Connection 32 1 DEL-1138 1/4" Hex Nipple 33 1 DEL-1012 Stainless Steel Upright Cart 34 2 DEL-9283 Plastic cap for legs 35 1 2 DEL-1013-01 DEL-0002 Stainless Steel face plate Brackets for face plate 36 1 DEL-1181 In-Line Strainer unit 37 2 DEL-2050 Hex Pipe Nipple 3/8 39 2 DEL-1107 55-59 mm Clamp 40 2 DEL-1025 Lower Bracket 41 2 DEL-2053 45 Elbow 1/4" NPT 42 1 4 DEL-2067 DEL-2071 Flange F25 5/16 Fine Thread Bolt (used to attach Flange to motor) 43 1 DEL-2069 Bronze Sleeve Bearing for ¾ Shaft 1 OD x1 ¼ length 44 1 DEL-2068 Shaft Adapter 3/4" to 1 Not shown 1 DEL-1046-120V GFCI Module 120V Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 24

DIAGRAM / SCHEMATIC Niedner Inc. DELTA HYDRO Hose Tester Model #CDHT2000GA-SS (gas upright cart) Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 25

DIAGRAM / SCHEMATIC Niedner Inc. DELTA HYDRO Hose Tester Model #CDHT2000GA-SS-LP (electric low profile cart) P A R T S L I S T No. Quantity Part Number Description 1 1 CA3500020B25B 2 NH (NST) x 2.5 NH (NST) DSW Female 3 6 DEL-52002 Check Valve Assembly 2.5NH (NST) (Hose tester serial number required to purchase this part) 9 1 DEL-1015-51 Manifold 2000 (Hose tester serial number required to purchase this part) 10 1 DEL-1022 Motor 5.5 HP Honda 11 1 DEL-1033 Inlet Nipple 2 NH 12 1 DEL-2033-ASSEM Pump assembly 5.6 GPM 13 1 DEL-1034 Ball Valve 1/4" 14 1 DEL-1038 Ball Valve 2 15 4 DEL-1049 5 Caster Wheels 16 2 DEL-1052 Street Elbow 1/2" - 90 17 2 DEL-1055 Street Elbow 3/8-90 18 1 DEL-1058 Brass 3 Connect Tee 3/8 19 1 DEL-1062 Pressure Regulator (unloader) Testers purchased prior to May 9, 2013 will also require 1 x DEL-1098. Reducer with ¼ is no longer available 20 1 DEL-1064 Hose 3/8 x 18 21 2 DEL-1066 Hose 1/2 x 15 22 1 DEL-1068 Brass 3 Connect Run Tee 1/2" 28 1 DEL-1087M Quick Connect Male 29 1 DEL-1098 Reducer 1/2" Female x 3/8 Male 30 1 DEL-1120 Thermal Relief Valve 31 1 DEL-1039-01 Gauge 1000 PSI BACK Connection 32 1 DEL-1138 1/4" Hex Nipple 33 1 DEL-1109 Stainless Steel low profile cart 36 1 DEL-1181 In-Line Strainer unit 37 2 DEL-2050 Hex Pipe nipple 3/8 42 1 4 DEL-2067 DEL-2071 Flange F25 5/16 Fine Thread Bolt (used to attach Flange to motor) 43 1 DEL-2069 Bronze Sleeve Bearing for ¾ Shaft 1 OD x1 ¼ length 44 1 DEL-2068 Shaft Adapter 3/4" to 1 Not Shown 1 DEL-1046-120V GFCI Module 120V Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 26

DIAGRAM / SCHEMATIC Niedner Inc. DELTA HYDRO Hose Tester Model #CDHT2000GA-SS-LP (electric low profile cart) Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 27

ACCESSORIES Niedner Inc. DELTA HYDRO Hose Tester All Models Tel: 800 567 2703 E-mail: sales@niedner.com Web site: www.niedner.com Page 28