ACCESS DOORS. Model Model Model Model Model

Similar documents
ACCESS DOORS GENERAL PRODUCT OVERVIEW

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

ISO 9001:2008

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES

ISO 9001:2008

TABBED ACCESS DOOR RANGE

LINEAR DIFFUSERS AND BAR GRILLES

DOOR French, Heavy Duty, Individual Dog Model 1620 Features 1


LINEAR DIFFUSERS AND BAR GRILLES

CEILING DIFFUSERS CEILING DIFFUSERS

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

ISO 9001:2008

SERIES 700 TECHNICAL DETAILS MONDAY, JANUARY 21, 2008

CONTROL DAMPERS GENERAL PRODUCT OVERVIEW MODELS 1010 & 1020 LOW LEAKAGE CONTROL DAMPER VEE GROOVE BLADE MODELS 1012 & 1022 STANDARD CONTROL DAMPER

FIRE RATED PRODUCTS FIRE RATED PRODUCTS

CONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc.

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

CEILING AIR INLETS CORROSION PROOF ECONOMICAL DURABLE. Ideal for all Agricultural applications.

KASON SLIDING DOOR HARDWARE

8600 SERIES. SPACE$SAVER DOORWARE Page C SPACE$SAVER. Page C-6. PREMIER DOORWARE Page C-11 ASSURED EXCELLENCE 8200 SPACE$SAVER

Durulite Door Hardware Manual

Maximum leakage rate is less than half of the AWWA allowable Can be adapted to any channel Low-maintenance gates ***

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Section Traffic Doors

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES

SERIES 500 TECHNICAL DETAILS THURSDAY, JANUARY 24, 2008

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

LINEAR SLOT DIFFUSERS PLENUMS

VANEAXIAL & TUBEAXIAL FANS

INDEX. Chapter3. air master. Linear Bar Grilles

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Thermal Isolation. Break

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

PERFORATED CEILING DIFFUSERS

DIAMOND DOOR PRODUCTS TECHNICAL DETAILS MARCH 2010

PERFORATED CEILING DIFFUSERS

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

CEILING DIFFUSERS D12 CEILING DIFFUSERS

Filter Lock ... SERIES 21FL/26FL/38FL/42FL CONSTRUCTION FEATURES PRODUCT DATA CLEAN-LINE TM 21FL/26FL/38FL/42FL PD-CLFL-03A JANUARY 2003

We make dampers easy for you!

AIR DUCT ACCESSORIES

ARROW INDUSTRIAL PRODUCTS

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

makes sure products are delivered Products are offered in steel,

INDEX. Chapter1 1. A. Jet diffusers 1. Jet diffuser...: AJD-P

MECHANICAL INSTALLATION PROCEDURES for Custom Grids and Support Framing

XeteX, Inc. All Rights Reserved.

"CLARITY WALL" VIF " 1 1 8" SECTION 1 2 " 3 8 " "CLARITY" SLIDING DOOR with FIXED GLASS PANEL BLOCKING & SUPPORT AS NEEDED SCHEDULED CEILING

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Section Traffic Doors

Automatic Roof Door Vents

VOLUME CONTROL DAMPERS

I Fan Powered Terminal Unit

HCD-230 Industrial Control Damper

TKS-5001, TKS , TKS-6001, TKS-7001

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

Concrete blast door NORFO TBS

EGG CRATE RETURN GRILLE

CEILING DIFFUSERS CEILING DIFFUSERS

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

Doors and fittings. Doors and fittings Aluminum Framing Hinge profile (p. 8-3) Hinge (p. 8-4) Hinge, plastic (p. 8-5)

Model # 358-OPR-GT. 4/15/2015 Page 1 of 12

DRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION

Access Doors. Sandwich Access Doors Quick and Easy. Industries, Inc. ACCESS DOORS

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Variable Air Volume Dampers

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

Access Doors. Sandwich Access Doors. Quick and Easy

Quality Consistency Stability WB FRU 810 WB FR DW 820 WB HG SEC 1100 WB EXT 1350 ULTRA. Series Series Series Series

Industry best 5 year fan housing warranty, 1 year motor warranty

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Registers for spiral ducts

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

GRILLES AND REGISTERS

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

SECTION DUCTWORK ACCESSORIES

SINGLE DUCT TERMINAL UNITS 3000 SERIES

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

LINEAR DIFFUSERS AND BAR GRILLES

GETO City body kit A high-performance solution for Sprinter Class vehicles

table of contents PRODUCT SUMMARY 2

Midea Air Handling Unit

University of Delaware

CEILING DIFFUSERS CEILING DIFFUSERS

F-SERIES TERAFRAME CABINET SYSTEM 23.6 W (600 mm) Cabinets

GRILLES AND REGISTERS

K1-2. Table of Contents LINEAR BAR GRILLES 1500, 1500MC, 1800, 1800MC

SECTION METAL ATHLETIC SPORT LOCKERS

DUNHAM-BUSH ecs3 Series

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED

ROOF HATCHES. Over 45 years of proven performance in Standard & Custom Designed Hatches SINCE 1965 NOW WITH R-20 INSULATED ROOF HATCHES!

Transcription:

MODEL 0840-6 PLENUM CCESS DOOR Nailor Model 0840-6 ultra-low leakage plenum access door provides easy access to larger plenums and equipment housings and is suitable for use in high, medium or low pressure applications. The design features include positive seal gasketing and insulation which provide assured low-leakage performance. The die-formed frame, hinged door and die-cast closure handles provide extra strength and maximum operational convenience. Model 0840-6 MODELS 0890 & 0895 FOR ROUND DUCT Nailor Model 0890 is an economical round duct access door suitable for use in low pressure applications. durable hinge permits the heavy duty 16 ga. (1.6) door to swing open fully, allowing unobstructed access to the duct, while the zinc plated strikes and catches and polyurethane foam gasketing provide a tight, positive seal when closed. Model 0895 turret style access doors provide heavy duty construction with easy opening, suitable for use in medium and high pressure round duct systems. Features include an all-welded turret box and saddle formed to duct radius, and a high-pressure 0800 Series access door that is caulked and fastened to turret. Zinc plated progressive camlocks and bulb type door gasket provide a secure, tight seal. Model 0890 Model 0895 MODEL 0900-1 & 0900-2 UTLTY FRE RTED & GENERL USE Nailor Model 0900-1 fire-rated access door is for use whenever it is necessary to provide service access to utilities located within fire separations such as corridor walls, stairwells and ceilings. The 2" (51) thick insulation, which acts as a heat barrier, is also ideal for reducing sound transmission through access opening. The flush key operated latch provides convenient and secure opening and closing. Model 0900-2 is a multi-purpose access door designed to provide convenient access to utilities contained within walls or ceilings. This versatile access door installs flush in drywall, masonry block or tile, and plaster walls and ceilings with a clean unobtrusive finish. Both models are offered in an array of standard sizes, with special sizes available upon request. Model 0900-1 Model 0900-2 4

PLENUM PLENUM CCESS DOOR HNGED NSULTED ULTR-LOW LEKGE Model: 0840-6 Model 0840-6 The Nailor Model 0840-6 ultra-low leakage plenum access door provides easy access to larger plenums and equipment housings and is suitable for use in high, medium or low pressure applications. The design features include positive seal gasketing and insulation which provide assured low-leakage performance. The die-formed frame, hinged door and die-cast closure handles provide extra strength and maximum operational convenience. 1 9 2 3 10 24 3/4" (629) 25 3/4" (679) 5 4 STNDRD CONSTRUCTON: 1. Frame: Die-formed 22 ga. (0.85) galvanized steel flange frame for strength. 2. Door Panel: Die-formed 22 ga. (0.85) galvanized steel door panel for extra strength. 3. nsulation: 1" (25) dual density insulation with 22 ga. (0.85) galvanized steel backing plate. 4. Hinge: Zinc plated piano hinge. 5. Fasteners: Die-cast closure hatches. 6. Seal: Positive bulb flexible PVC door seal. 7. Template: Layout template included. 8. Mounting: 3/16" (5) dia. pre-punched attachment holes on inner flange for surface mounting. 16 3/4" (425) 25" x 17" (635 x 432) NOMNL SZE 18 3/4" (476) 6 COMMON OPTONS: 9. Viewport: Viewport - 5 1/2" (140) dia.. 10. Mounting: 3/16" (5) dia. pre-punched attachment holes on outer flange for flush mounting. LEKGE NFORMTON: Conforms to British Standard DW144 Class, B and C. Maximum allowable leakage at 8" w.g. (2 kpa): 0.286 cfm (8.1 l/min.) 13

PLENUM HOW TO ORDER OR TO SPECFY MODEL: 0840-6 PLENUM CCESS DOOR EXMPLE: 0840-6 - 2517 - VP - PO 1. Model 0840-6 Plenum ccess Door, 25" x 17" (635 x 432) only OPTONS: 2. VP Viewport. 3. PO Pre-punched holes on outer flange. SUGGESTED SPECFCTON: Provide and install as shown on plans and/or schedules, plenum access doors as manufactured by Nailor ndustries, nc., which meet the following criteria: ccess doors shall meet British Standard DW144 Class C for leakage. Manufacturer shall submit leakage data tested to minimum of 8 in. w.g. (2 kpa). Frame shall be of oval design, constructed of die-formed 22 ga. (0.85) galvanized steel. Door shall constructed of double skin die-formed 22 ga. (0.85) galvanized steel with 1" (25) insulation fully enclosed within the door panel. Door shall be attached to frame with continuous plated steel piano hinge and shall close securely by means of two die-cast closure handles. Bulb type seal shall be integrally fastened to door for positive seal. Standard of acceptance shall be Nailor ndustries Model 0840-6. 14

PLENUM OUT-SWNG FRME (NEGTVE PRESSURE) THERML BREK PLENUM CCESS DOOR EXTRUDED LUMNUM FRME NSULTED STEEL DOOR PNELS Models: 0850-2L Left Hinge 0850-2R Right Hinge Standard Sizes: 12 x 12 (305 x 305) 30 x 72 (762 x 1829) 18 x 18 (457 x 457) 36 x 36 (914 x 914) 18 x 24 (457 x 610) 36 x 48 (914 x 1219) 24 x 24 (610 x 610) 36 x 60 (914 x 1524) 24 x 36 (610 x 914) 36 x 72 (914 x 1829) 24 x 48 (610 x 1219) 36 x 84 (914 x 2134) 24 x 60 (610 x 1524) 48 x 48 (1219 x 1219) 24 x 72 (610 x 1829) 48 x 60 (1219 x 1524) 30 x 36 (762 x 914) 48 x 72 (1219 x 1829) 30 x 48 (762 x 1219) 48 x 84 (1219 x 2134) 30 x 60 (762 x 1524) 48 x 96 (1219 x 2438) Model 0850-2R (with optional viewport) Nailor Model Series 0850 thermal break plenum access doors are ultra-low leakage, premium quality doors designed for out-swing (negative pressure) applications. Design features include extruded aluminum frames with attractive mitered corner construction, thermal break door and frame design that utilizes pour-and-debridging technology to achieve levels of thermal isolation unsurpassed by other methods and double door gaskets to assure low levels of leakage. standard 3 lb. density insulation is used between the 20 ga. (1.0) galvanized steel inner and outer door panels. Ergonomic adjustable door latches have cam-locking surfaces for smooth operation and positive seal. ll units feature full length stainless steel piano type hinges, for either left hand or right hand operation. NOMNL SZE 1/4" (6) CCESS OPENNG = NOMNL SZE 3 1/2" (89) 2 1/4" (57) WDTH 1/4" (6) OPTONL VEWPORT NNER ND OUTER DOOR GSKETS THERML BREKS SEPRTE NSDE FROM OUTSDE HEGHT 1/4" (6) OPTONL VEWPORT DOOR PERMETER FRME FLNGED OUTER FRME CROSS-SECTON - MODEL 0850-2L LEFT HND HNGE MODEL 0850-2R RGHT HND HNGE 15

PLENUM N-SWNG FRME (POSTVE PRESSURE) THERML BREK PLENUM CCESS DOOR EXTRUDED LUMNUM FRME NSULTED STEEL DOOR PNELS Models: 0855-2L Left Hinge 0855-2R Right Hinge Standard Sizes: 12 x 12 (305 x 305) 30 x 72 (762 x 1829) 18 x 18 (457 x 457) 36 x 36 (914 x 914) 18 x 24 (457 x 610) 36 x 48 (914 x 1219) 24 x 24 (610 x 610) 36 x 60 (914 x 1524) 24 x 36 (610 x 914) 36 x 72 (914 x 1829) 24 x 48 (610 x 1219) 36 x 84 (914 x 2134) 24 x 60 (610 x 1524) 48 x 48 (1219 x 1219) 24 x 72 (610 x 1829) 48 x 60 (1219 x 1524) 30 x 36 (762 x 914) 48 x 72 (1219 x 1829) 30 x 48 (762 x 1219) 48 x 84 (1219 x 2134) 30 x 60 (762 x 1524) 48 x 96 (1219 x 2438) Model 0855-2R Nailor Model Series 0855 thermal break plenum access doors are ultra-low leakage, premium quality doors designed for in-swing (positive pressure) applications. Design features include extruded aluminum frames with attractive mitered corner construction, thermal break door and frame design that utilizes pour-and-debridging technology to achieve levels of thermal isolation unsurpassed by other methods and double door gaskets to assure low levels of leakage. standard 3 lb. density insulation is used between the 20 ga. (1.0) galvanized steel inner and outer door panels. Ergonomic adjustable door latches have cam-locking surfaces for smooth operation and positive seal. ll units feature full length stainless steel piano type hinges, for either left hand or right hand operation. 2 1/4" (57) CCESS OPENNG = NOMNL SZE 3 1/2" (89) NOMNL SZE 1/4" (6) OPTONL VEWPORT NNER ND OUTER DOOR GSKETS DOOR PERMETER FRME FLNGED NNER FRME THERML BREKS SEPRTE NSDE FROM OUTSDE OPTONL VEWPORT HEGHT 1/4" (6) CROSS-SECTON - MODEL 0855-2L LEFT HND HNGE WDTH 1/4" (6) MODEL 0850-2R RGHT HND HNGE 16

PLENUM HOW TO ORDER OR TO SPECFY MODELS: 0850-2L, 0850-2R, 0855-2L & 0855-2R THERML BREK PLENUM EXMPLE: 0855-2L - DH2 - VP8 1. Models Negative Pressure 0850-2L Negative Pressure, Out-swing Frame, Right Hand Hinge 0850-2R Negative Pressure, Out-swing Frame, Left Hand Hinge Positive Pressure 0855-2L Positive Pressure, n-swing Frame, Left Hand Hinge 0855-2R Positive Pressure, n-swing Frame, Right Hand Hinge OPTONS: 2. Door Handles DH0 None, Prep Only. DH2 2 Per Door (recommended min. for door heights under 60" [1524]). DH3 3 Per Door (recommended min. for door heights 60" [1524] through 80" [2032]). DH4 4 Per Door (recommended min. for door heights over 80" [2032]). 3. View Port Dual Pane, hermetically sealed Lexan view glass window. VP8 8" (203) round. Minimum door size is 18" x 18" [457 x 457]). VP12 12" (305) round. Minimum door size is 24" x 24" [610 x 610]). SUGGESTED SPECFCTON: Provide and install as shown on plans and/or schedules, thermal break plenum access doors as manufactured by Nailor ndustries, nc., which meet the following criteria: Frames shall be extruded aluminum with mitered corner construction. Door panels shall be constructed of 20 ga. (1.0) galvanized steel. nsulation between door panels shall be 3 lb. density. Thermal isolation shall be achieved utilizing pour-and-debridging technology and each door shall be complete with double gaskets assuring low leakage performance. Door shall be attached to frame with continuous stainless steel piano type hinge and shall close securely by means of die cast closure handles. 1. Out-swing (negative pressure) operation. Standard of acceptance shall be Nailor ndustries Model (specifier to select) 0850-2L with left hand hinge or 0850-2R with right hand hinge or 2. n-swing (positive pressure) operation. Standard of acceptance shall be Nailor ndustries Model (specifier to select) 0855-2L with left hand hinge or 0855-2R with right hand hinge. 17