INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Similar documents
Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS kva kva 3:1 3:3 VFI TYPE

Master Plus kva

Master MPS kva kva 3:1 3:3 VFI TYPE

Master Plus kva

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

Master DIALOG INDUSTRY RANGE

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

UPS Multi Sentry 10-20kVA

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Master MPS kva kva 3:1 3:3 VFI TYPE

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

Multi Sentry kva kva 3:3 VFI. Complete range kva Small footprint

set out in standard IEC EN ). Multi Sentry is designed and built using state-of-the-art technology and components.

Master MPS kva kva 3:1 3:3 VFI TYPE

Sirius series. UPS kva single/single-phase and three/single-phase kva three/three-phase. online

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

SR series. on-line

HAIRF UPS. X5 Series KVA

Technical Data Sheets

SIRIUS Online UPS. data CeNTReS. TeleCoMMUNICATIoN devices. MedICAl devices. emergency devices. TRANSPoRTATIoN. Smart Energy Solutions

TECHNICAL DATA SHEET KVA UPS Systemss

Technical Data Sheets

EFFEKTA Power Supplies

Industrial PFC UPS System

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

1.1 GENERAL CHARACTERISTICS

Green Power 2.0 MASTERYS GP

Technical data sheets

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Data Sheets

UPS Multi Power 1-28 x 42 kw up to 1MW

Technical Data Sheets

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MKN-DSP SERIES - THREE PHASE

Technical Data Sheets

ConceptpowerTM Modular kVA

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

Three Phase UPS Systems Range: 10 to 500kVA

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

POWER kva

60 to 160 kva.

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

PowerValue 11/31 T kva

TLE Series UPS 400/500 kw With eboost Technology

POWERTRONIX QUASAR 5-40 KVA

MASTERYS IP+ 10 to 80 kva

PowerWave 33 Efficient power protection for today s IT and process-related work environments

D Series: UPS UPTO - 300KVA - Three / Three Phase

TLE Series UPS 160/200/225/250 kw with eboost Technology

POWER kva

Phase Modular Finally the benefits of Modular ups are for all

PowerScale TECHNICAL SPECIFICATIONS

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

MGE TM Galaxy TM 7000 GFC

PowerScale kva Technical Specifications

Technical Data Sheets

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

MGE TM Galaxy TM 7000

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

» Sophisticated» Reliable» Intelligent

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

TECHNICAL SPECIFICATIONS

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Liebert. FP 50Z kva

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

YOUR POWER IN SAFE HANDS. E Series UPS

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

Transcription:

Local Area NETWORKS (LAN) ServerS DATA CENTRES TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms) Master MPS 10- kva Three-phase/Three-phase 10-100 kva Three-phase/Single-phase Highlights Efficiency Control System (ECS) Galvanic isolation High overload capacity LCD display Extensive parallel configurations 6 Total protection MASTER MPS series UPS provides maximum protection and power quality for critical loads, including data centres, industrial processes, telecommunications, security and electro-medical systems. The UPS is an On-line double conversion UPS (VFI SS 111 - IEC EN 62040-3) with a transformer isolated inverter. The MASTER MPS range includes three-phase input and single-phase output versions from 10 to 100kVA, and three-phase input and output versions from 10 to kva. Three phase MPS models from 10 to 200 kva are available with a 6 or 12-pulse thyristor-based rectifier. From 100 to 500 kva, the Master HP series has an IGBT-based rectifier, to 68

provide lower harmonic input current distortion (THDi) and a high input power factor (see Master HP section). From 600 to kva, Master MPS have a 12-pulse rectifier and optional harmonic filters. Easy source MASTER MPS technology removes the problems of oversizing upstream power sources, whilst improving load power factors and current harmonics. The MPS range features the latest input-current absorption techniques including progressive rectifier start-up and the option to reduce battery charging currents. These features make the MASTER MPS series one of the most generator and environmentally friendly UPS available. Power continuity For years, Riello UPS has developed and supplied solutions for dealing with the different requirements and the problems that inevitably arise in critical applications. Riello UPS offers flexible, high-availability solutions that are able to adapt to different system structures and critical levels. Riello UPS creates UPS systems that can tolerate a number of component or subsystem failures, while continuing to operate normally, to provide service without interruption. This is achieved by installing carefully designed redundant elements, eliminating common failure points, scheduling maintenance activities and through the control and supervision of the operating parameters of the system and the environment. The TEC service team is ready to provide guidance and advice on projects. Flexibility MASTER MPS is suitable for a wide range of applications including IT and the most demanding industrial environments. The UPS is suitable for power capacitive loads such as blade servers, without any reduction in active power, from 0.9 leading to 0.8 lagging. With a broad range of accessories and options, complex configurations and system architectures can be achieved to guarantee maximum power availability and the option to add new UPS without interruption to existing users. Using the Riello UPS Group Synchroniser (UGS) and Parallel Systems Joiner (PSJ), sophisticated inter group parallel and redundant systems can be achieved to provide the highest possible levels of resilience and availability. care system: maximum battery care Normally the batteries are kept charged by the rectifier; when mains power fails, the UPS uses this energy source to power the inverter loads. Therefore, proper battery care is critical to ensuring correct UPS operation in emergency conditions. The Riello UPS Care System consists of a series of features and capabilities to optimise battery management and obtain the best performance and operating life possible. Dual level charging regime to optimise recharge currents and reduce charge times Temperature compensation and deep discharge protection to reduce overall battery ageing Charge blocking system to reduce electrolyte consumption and lengthen the life of VRLA batteries tests to diagnose, in advance, any reduction in performance or problems with the batteries. MASTER MPS is also compatible with different battery technologies: vented open lead acid, VRLA AGM and NiCd. Ease of Installation MASTER MPS requires only a very small space for installation (only 0.64 sqm for a 200KVA system); in addition, front access allows servicing of all major components from the front panel, making side access unnecessary. MASTER MPS requires minimal space for access, utilising top-cabinet ventilation and front panel access. Specific solutions The UPS can be adapted to meet your requirements. Contact our TEC team to discuss specific solutions and options not listed in this catalogue. Advanced communication Compatible with TeleNetGuard for remote monitoring. Advanced communication, multiplatform, for all operating systems and network environments: Supervision and shutdown PowerShield 3 software for Windows operating systems 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris, Linux, Novell and other Unix operating systems. UPS is supplied with a cable for direct PC connection (Plug and PLay) RS232 double serial port Communications slot for network adapter installation; ESD contact (Emergency Switching Device) for switching off the UPS by remote emergency button. Remote LED mimic panel or graphic display. Maximum reliability and availability Distributed or centralised parallel configuration of up to 8 units per redundant (N+1) or power parallel system, even using different power ratings. Hot System Expansion (HSE): allows the addition of a further UPS into an existing system, without the need to switch off the UPS or transfer them to bypass mode. This guarantees maximum load protection, even during maintenance and system expansion. Maximum levels of availability, even in the event of an interruption to the parallel bus cable: the system is FAULT TOLERANT. It is not affected by connection cable faults and continues powering the load without disruption, signalling an alarm condition. Efficiency Control System (ECS): a system to optimise the operating efficiency of parallel systems, according to the power required by the load. N +1 redundancy is guaranteed, with every UPS working in parallel at the best load level possible. 69

OPTIONS UPS Group Synchroniser (UGS): allows two or more non-parallel UPS devices to remain synchronised even during mains power failure. The UGS also enables a Riello UPS to be synchronised with another power source that is independent and of a different power rating. Parallel Systems Joiner (PSJ): connects two UPS groups in parallel configurations through a power couplign switch. The Slave UPS group is permanently synchronised to the master group. Should one of the UPS in one of the parallel groups fail, the PSJ will automatically connect the remaining UPS to the other group via an external bypass. Maintenance Bypass Cabinet Bypass mains UPS1 UPS2 UPS3... UPS8 Load Parallel configuration of up to 8 units with distributed bypass Parallel architecture to ensure redundancy of the power source. +Flexibility and modularity System A UPS1A Bypass 1 UPS2A UGS Sinchroniser System B Bypass 2 UPS1B UPS2B Bypass mains UPS1 UPS2 UPS3... UPS8 Common BY PASS UPS1A UPS2A PSJ Load Parallel configuration of up to 8 units with common bypass Parallel architecture to ensure redundancy of the power source, with autonomous bypass management. + Selectivity of downstream faults in bypass mode System A Bypass 1 System B Bypass 2 UPS1B UPS2B Static Transfer SWITCH SWITCH Load 3 Load 1 Static Transfer SWITCH Load 2 Load 1 Load 2 Load 4 Dynamic dual bus configuration Solution to ensure redundancy until the distribution of the power supply to the loads + Downstream fault discrimination Dual bus system configuration Solution to ensure redundancy of the power supply even during maintenance + High availability and redundancy 70

Dimensions (mm) MPM/MPT 10 40 MPM/MPT 60 80 MPT 100 - MPT 120 MPT 160- MPT 200 MPT 600 MPT 555 740 740 3200 980 4400 1000 box MODELS MODELS UPS Dimensions (mm) BB 396-L6 / BB 396-L7 BB 396-L8 / BB 396-L9 MPT 100-200 MPM 100 860 BB 480-L6 / BB 480-L7 BB 480-L8 / BB 480-L9 MPT 600- MHT 100-500 BB 384-B1 555 740 BB 384-B2 / BB 384-B3 BB 384-B4 / BB 384-B5 MPT 10-60 MPT 10-80 MODELS TCE 270 TCE 400 TLE 400 MODELS UPS MPT 100-200 / MPM 100 MHT 100-250 MPT D 600- / MHT 300-500 Dimensions (mm) 860 740 270 400 850 400 1000 71

Isolation transformers MODELS TI 10 T / TI 15 T / TI 20 T TI 30 T / TI 40 T TI 60 T / TI 80 T TI 100 T / TI 120 T TI 160 T TI 200 T / TI 250 T TI 300 T / TI 400 T TI 500 T / TI 600 T Dimensions (mm) 1200 OPTIONS Isolation transformer Synchronisation device (see UGS) Hot connection device (see PSJ) Generator interface Closed Loop parallel kit option (Closed loop: to be ordered with the UPS) cabinets 555 720 640 720 650 1200 1000 72

MODELS MPM 10 * MPM 15 * MPM 20 * MPM 30 MPM 40 MPM 60 MPM 80 MPM 100 POWER 10 15 20 30 40 60 80 100 INPUT 380-400 - 415 Vac Three-phase Voltage tolerance 400 V + 20% /- 25% Soft start 45-65 Hz 0 100% in 30 (selectable) Permissible frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Standard equipment provided standard Back Feed protection; separable bypass line BATTERIES Type open lead acid and VRLA AGM / GEL; NiCd. Residual ripple voltage < 1% Temperature compensation -0.5 Vx C Typical charge current 0.2 x C10 OUTPUT Nominal power (kva) 10 15 20 30 40 60 80 100 Active power (kw) 9 13.5 18 27 36 54 72 90 Number of phases 1 220-230 - 240 Vac Single-phase Static stability ± 1% Dynamic stability ± 5% in 10 ms Voltage distortion < 1% with linear load / < 3% with non-linear load Crest factor (lpeack/lrms) 3:1 stability on battery 0.05% 50 or 60 Hz (selectable) Overload 110% for 60 ; 125% for 10 ; 150% for 1 INFO FOR INSTALLATION Net weight 200 220 230 290 340 440 520 650 Dimensions (hwd) (mm) x 555 x 740 x x 740 x x Remote signals volt-free contacts Remote controls ESD and bypass Communication Double RS232 + remote contacts + 2 slots for communications interface Ambient temperature 0 C / +40 C Relative humidity < 95% non-condensing Colour Dark grey RAL 7016 Noise level at 1 m (dba) 54 62 62 63 Protection level IP20 Smart Active Output up to 98% Regulations Regulatory Directives LV 2006/95/EC - 2004/108/EC; IEC Safety EN 62040-1; EMC IEC EN 62040-2; IEC Performance EN 62040-3 Classification according to IEC 62040-3 (Voltage Independent) VFI - SS - 111 * Also available with internal batteries 73

MODELS MPT 10 * MPT 15 * MPT 20 * MPT 30 MPT 40 MPT 60 MPT 80 POWER 10 15 20 30 40 60 80 INPUT 380-400 - 415 Vac Three-phase Voltage tolerance 400 V + 20% /- 25% Soft start Permissible frequency tolerance Standard equipment provided standard BATTERIES Type 45 65 Hz 0 100% in 30 (selectable) ± 2% (selectable from ± 1% to ± 5% from front panel) Back Feed protection; separable bypass line open lead acid and VRLA AGM / GEL; NiCd. Residual ripple voltage < 1% Temperature compensation Typical charge current OUTPUT -0.5 Vx C 0.2 x C10 Nominal power (kva) 10 15 20 30 40 60 80 Active power (kw) 9 13.5 18 27 36 54 72 Number of phases 3 + N 380-400 - 415 Vac Three-phase + N Static stability ± 1% Dynamic stability Voltage distortion ± 5% in 10 ms < 1% with linear load / < 3% with non-linear load Crest factor (lpeack/lrms) 3:1 stability on battery 0.05% 50 or 60 Hz (selectable) Overload 110% for 60 ; 125% for 10 ; 150% for 1 INFO FOR INSTALLATION Weight without internal batteries (kg) 212 220 230 280 330 450 600 Dimensions (hwd) (mm) x 555 x 740 x x 740 Remote signals Remote controls Communication Ambient temperature Relative humidity volt-free contacts ESD and bypass Double RS232 + remote contacts + 2 slots for communications interface 0 C / +40 C < 95% non-condensing Colour Dark grey RAL 7016 Noise level at 1 m (dba) 54 60 62 Protection level Smart Active Output up to 98% Regulations Classification according to IEC 62040-3 * Also available with internal batteries IP20 Regulatory Directives LV 2006/95/EC - 2004/108/EC; IEC Safety EN 62040-1; EMC IEC EN 62040-2; IEC Performance EN 62040-3 (Voltage Independent) VFI - SS - 111 74

MODELS MPT 100 MPT 120 MPT 160 MPT 200 POWER 100 120 160 200 INPUT 380-400 - 415 Vac Three-phase Voltage tolerance 400 V + 20% /- 25% Soft start 45 65 Hz 0 100% in 30 (selectable) Permissible frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Standard equipment provided standard Back Feed protection; separable bypass line BATTERIES Type open lead acid and VRLA AGM / GEL; NiCd. Residual ripple voltage < 1% Temperature compensation -0.5 Vx C Typical charge current 0.2 x C10 OUTPUT Nominal power (kva) 100 120 160 200 Active power (kw) 90 96 144 180 Number of phases 3 + N 380-400 - 415 Vac Three-phase + N Static stability ± 1% Dynamic stability ± 5% in 10 ms Voltage distortion < 1% with linear load / < 3% with non-linear load Crest factor (lpeack/lrms) 3:1 stability on battery 0.05% 50 or 60 Hz (selectable) Overload 110% for 60 ; 125% for 10 ; 150% for 1 INFO FOR INSTALLATION Weight (kg) 640 650 770 810 Dimensions (hwd) (mm) x x Remote signals volt-free contacts Remote controls ESD and bypass Communication Double RS232 + remote contacts + 2 slots for communications interface Ambient temperature 0 C / +40 C Relative humidity < 95% non-condensing Colour Dark grey RAL 7016 Noise level at 1 m (dba) 63 68 Protection level IP20 Smart Active Output up to 98% Regulations Regulatory Directives LV 2006/95/EC - 2004/108/EC; IEC Safety EN 62040-1; EMC IEC EN 62040-2; IEC Performance EN 62040-3 Classification according to IEC 62040-3 (Voltage Independent) VFI - SS - 111 75

MODELS MPT 600 MPT POWER 600 INPUT 380-400 - 415 Vac Three-phase Voltage tolerance 400 V ± 20% Power factor Current distortion Soft start Permissible frequency tolerance Standard equipment provided standard BATTERIES Type 45 65 Hz > 0.93 in HC version < 3% in HC version 0 100% in 30 (selectable) ± 2% (selectable from ± 1% to ± 5% from front panel) Back Feed protection; separable bypass line open lead acid and VRLA AGM / GEL; NiCd. Residual ripple voltage < 1% Temperature compensation Typical charge current OUTPUT -0.5 Vx C 0.2 x C10 Nominal power (kva) 600 Active power (kw) 480 640 Number of phases 3 + N 380-400 - 415 Vac Three-phase + N Static stability ± 1% Dynamic stability Voltage distortion ± 5% in 10 ms < 1% with linear load / < 3% with non-linear load Crest factor (lpeack/lrms) 3:1 stability on battery 0.05% 50 or 60 Hz (selectable) Overload 110% for 60 ; 125% for 10 ; 150% for 1 INFO FOR INSTALLATION Weight (kg) 4000 5300 Dimensions (hwd) (mm) x 3200 x 1000 x 4400 x 1000 Remote signals Remote controls Communication Ambient temperature Relative humidity voltage-free contacts ESD and bypass Double RS232 + remote contacts + 2 slots for communications interface 0 C / +40 C < 95% non-condensing Colour Dark grey RAL 7016 Noise level at 1 m (dba) < 75 < 78 Protection level Smart Active Output up to 98% Regulations Classification according to IEC 62040-3 IP20 Regulatory Directives LV 2006/95/EC - 2004/108/EC; IEC Safety EN 62040-1; EMC IEC EN 62040-2; IEC Performance EN 62040-3 (Voltage Independent) VFI - SS - 111 support@upsdirect.com +44 (0)8456 445 002 UPS Direct Ltd Column House, London Road Shrewsbury SY2 6NN England