TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation

Similar documents
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON

Thermal-Magnetic Circuit Breaker M1-...

Thermal Circuit Breaker 3120-F...

High Performance Thermal Circuit Breaker

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Magnetic Overcurrent Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TECHNICAL DATA

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker

circuit breakers circuit breakers Thermal Circuit Breaker, rotary knob actuation, 1-, 2- or 3-pole Description Applications

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal-Magnetic Circuit Breaker M1-..

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications

Thermal Overcurrent Circuit Breaker 3130

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TeChniCAl DATA

High Performance Thermal-Magnetic Circuit Breakers 410/520/

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Essential equipment for all your requirements

Control Circuit Protection

Electronic Circuit Breaker ESS20-0..

Thermal Overcurrent Circuit Breaker 3130

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Technical data for manual motor starters Type MS325

KT4 Manual Motor Starter

Simulator switch, magnetic operation

Ideal for use as a manual starter

max pole for t=15 ms

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

Thermal Overcurrent Circuit Breaker 3130

Miniaturized limit switches

Circuit Breakers. DIN rail-mounted equipment protection

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Protection components

Protection Equipment. 5/2 Introduction

PD-Series Ground Fault Circuit Protection

Electronic Circuit Breaker ESS20

TMC 91H is now TMC 60 C Series

Electronic circuit breaker EBU10-T

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

UMBW-UL489 and UL1077 Listed

AF series contactors (9 2650)

3VU13, 3VU16 Circuit-Breakers

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Low Voltage A GE Power Controls Company. General catalogue

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Miniature Circuit-Breakers (MCBs)

Thermal overload relay TF65 and TF96

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE

AF series contactors (9 2650)

and other modular devices for low voltage installation

Miniature Circuit-Breakers (MCBs)

MINIATURE CIRCUIT BREAKER

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

Manual Motor Starters. Meta-MEC

SIRIUS 3RU2 Thermal Overload Relays

Jtec 10kA Miniature Circuit Breaker

General_technical_data Series

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Technical Information

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

Thermal overload relay TF140DU and TF140DU-V1000

Pre wired limit switches

Thermal Overload Relays - WEG RW Series, 2 Pole

Ktec Contactors and thermal overloads

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Selection Guide Motor Control Device Solutions

Residual current circuit breakers with conditional shortcircuit

cor Long Run Experience

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

Electronic overload relay EF65, EF96 and EF146

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Thermal Circuit Breaker / Switch Series 3131

60T Series Snap-Action Temperature Controls

D509E. Manual Motor - Starters

Btdin RCBO 6000A up to 63A (2P)

Thermal Circuit Breaker / Switch Series 3131

Protection Equipment

Transcription:

CIRCUIT BREAKERS FOR EQUIPMENT TM Series Thermal magnetic release Positively trip-free Reset or manual actuation The TM circuit breaker for equipment (CBE) is a single pole, thermal-magnetically operated device providing small size, low cost and reliable trip-free operation on overloads and short circuits within the maximum breaking capacity. It is intended primarily for the protection of circuit control functions in sensitive instruments etc. It is not generally suitable for line protection unless the prospective short circuit current is less than 00 A at 0 V a.c. (00 A at 8 V d.c.). Threaded neck and flange mounting types are available each with optional push on/push off mechanism, shunt terminal and auxiliary contact. There is also a choice of screw clamp terminals on certain types. The well proven mechanism is designed to open the contacts in the event of overloads. A bimetal strip is heated by the overcurrent and deflects, thereby releasing the latch mechanism. If the overcurrent is sufficiently high, the magnetic release will operate and open the circuit instantaneously. Two characteristics are available. The more commonly used T characteristic has operating limits between 8- times the rated current. The optional F characteristic operates at a lower current levels of -8 times the rated current. In case of overloads, the contacts will open even if the reset button is manually held in the closed position. This is known as a trip-free feature. The contacts open and close with a snap action and the tripped state is clearly shown by the increased projection of the reset button. After the opening operation, the reset button has to be fully depressed, then released, to effect a closing of the contact. It is impossible to «tease» the contacts by gentle pressure on the reset button. Available options Fast and slow magnetic tripping characteristics Flange type Threaded neck type Type of actuation: reset or manual / (push/push) Terminals: quick connect or screw clamp terminals Independent auxiliary contact (change-over contact) Shunt terminal Setting indication on reset button indicates the position of the contacts Special features Competitive pricing Quick connect terminals Choice of mounting styles Positively trip-free Insensitive to shock or vibration UL, CSA, VDE and other approvals Schurter, Inc. Phone 707-778-3 Fax 707-778-0 E-mail info@schurterinc.com Website http://www.schurterinc.com 93

CIRCUIT BREAKERS FOR EQUIPMENT TM Effect of ambient temperature Tripping characteristics TMF + TMT The unit is calibrated for an ambient temperature of +3 C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below: 0 30 0 0 5 [ min ] [ sec ] 0'000 '000 Rated current < 7,0 A 7,0 A Ambient temp.. +3 C Ambient temperature [ C] Correction factor 00 0-5 0,87 0 0,90 +0 0,95 +3,00 +30,05 +0, +50,0 +0,30 Example Rated current at +3 C 5,0 A Ambient temperature +50 C Correction factor, Chosen rated current at +50 C ambient temperature 5,0 A x, =,0 A Tripping time TMF TMT 0, 0,0 0,00 0,000,05,3 5 8 0 0 50 Multiple of rated current [ x In Technical data Main circuit Rated voltage Ue See approvals, page 95 AC 0 V; DC 8 V Rated current I n See approvals, page 95 AC/DC 0,05 A Conditional short circuit current I nc EN 0 93 PC, AC 0 V 000 A Short circuit capacity I cn AC 0 V 00 A AC/DC 8 V 00 A Auxiliary circuit Rated voltage Ue See approvals, page 95 AC 0 V, 0 V; DC 8 V Rated current I n See approvals, page 95,0;,0; 3,0 A Class of protection Between live and accessible parts II Other parts I 9 Schurter, Inc. Phone 707-778-3 Fax 707-778-0 E-mail info@schurterinc.com Website http://www.schurterinc.com

CIRCUIT BREAKERS FOR EQUIPMENT TM Technical data (continued) Degree of protection Accessible range IP0 Termination range IP00 Dielectric strength Accessible range AC 000 V Insulation resistance DC 500 V >00 MΩ Endurance Number of cycles at x I n (AC) R-type 0 Number of cycles at I n S-type 5000 Permissible ambient temperature -5 C to +0 C Vibration resistance IEC 8--, Test Fc, 0 g mm amplitude 5-0 Hz, 0-500 Hz Shock resistance IEC 8--, Test Ea 00 g Type of actuation Reset type R Manual / (push/push) S Type of tripping Thermal-magnetic TM Positively trip-free Weight approx. 33 g Approvals Main circuit Auxiliary circuit Rated Rated Rated Rated Rated Rated current range voltage AC voltage DC current voltage AC voltage DC UL 077 0,05 A 0 V 8 V 3 A 8 V A 0 V CSA C, 0,05 A 0 V 8 V A 0 V VDE EN 093 0,05 A 0 V 8 V A 0 V 8 V SEMKO 0,05 A 0 V A 0 V NEMKO 0,05 A 0 V A 0 V DEMKO 0,05 A 0 V A 0 V SEV EN 093 0,05 A 0 V 8 V A 0 V 8 V Schurter, Inc. Phone 707-778-3 Fax 707-778-0 E-mail info@schurterinc.com Website http://www.schurterinc.com 95

CIRCUIT BREAKERS FOR EQUIPMENT TM Order code Basic type TM Single pole thermal magnetic overload protection switch, positively trip-free Magnetic release range** F T Fast Slow Mounting style Flange type Threaded neck type M0 x, with hexagonal- and knurled nut Actuation type Reset type Manual / (push/push) Terminal type,3 x 0,8 mm quick connect terminals DIN -A Screw clamp terminals* * Not available with S-auxiliary contact or N-shunt terminal Construction variants * S N R Auxiliary contact Shunt terminal only for rated currents <7 A Setting indication on reset button * (S; N; R; SN; SR; NR; SNR) Rated current 0,05 0, 0,5 0, 0,3 0, 0,5 0, 0,7 0,8 0,9,0,,,3,,5,,7,8,9,0,,3,5,8 3,0 3,3 3,5,0,5 5,0 5,5,0,5 7,0 7,5 8,0 8,5 9,0 9,5 0 3 5 Other rated currents by request ** The magnetic tripping range is valid for AC. For DC the stated magnetic currents are approx., x higher. Accessories TZZ 0 Protective cover for threaded neck mounted front side IP5 T M F S N R 0,5 T Z Z 0 Order example 9 Phone 707-778-3 Fax 707-778-0 E-mail info@schurterinc.com Website http://www.schurterinc.com Schurter, Inc. Phone 707-778-3 Fax 707-778-0 E-mail info@schurterinc.com Website http://www.schurterinc.com

SW 3 CIRCUIT BREAKERS FOR EQUIPMENT TM Threaded neck type TMx- TMx-N M 0x Maximum torque,5 Nm 8 M 0x Maximum torque,5 Nm 8 8.5 +0.5 0. 8.7 0 ±0..5 ±0..5 SW 3.5 8.5 +0.5 0. 8.7. 0 8..5 SW 3 TMx- Cut-out M 0x Maximum torque,5 Nm 8 8. +0. 0.0 8.7 0 with without Anti-rotation protection 8.5 +0.5 0. M ±0..5.5 Schurter, Inc. Phone 707-778-3 Fax 707-778-0 E-mail info@schurterinc.com Website http://www.schurterinc.com 97

CIRCUIT BREAKERS FOR EQUIPMENT TM Flange type TMx- TMx-SN 5 50 Ø.5 50 Ø.5 3.5 0.7 8.5 +0.5 0. 3.5 0.7 8.5 +0.5 0. A ±0. 58 Ø.5.5 9.5 0. ±0. 8. 8..5 3.5 0.7 8.5 +0.5 0. ±0. ±0. M TMx- 50 Ø.5 ±0. 58 Ø.5.5 Cut-out ±0. 58 Ø.5 Installation from rear 3 3 9.5 30.5 Installation from front 3 3.5.5.5.5 98 Schurter, Inc. Phone 707-778-3 Fax 707-778-0 E-mail info@schurterinc.com Website http://www.schurterinc.com

CIRCUIT BREAKERS FOR EQUIPMENT TM Schematic diagrams accessories colors Schematic diagrams TM-... TM-...N TM-...S TM-...SN 5 5 I> I> 3 3 Accessories Protective transparent cover Degree of protection IP5 TZZ0 Colors Black Setting display R white Nickel plated Black Ø White label Nickel plated Black galvanized 7 8 Schurter, Inc. Phone 707-778-3 Fax 707-778-0 E-mail info@schurterinc.com Website http://www.schurterinc.com 99