Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Similar documents
Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Type MS450 MS497. Phone: Fax: Web: - Manual motor protectors

smissline Description

Phone: Fax: Web: -

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Miniature Circuit Breakers

Manual Motor Starter MS 116. Technical Catalogue

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Motor Controllers + Circuit Breakers

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Technical data for manual motor starters Type MS325

Technical Catalogue. Manual Motor Starters MS 116, MS 325, MS 4xx

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

Technical Catalogue Manual Motor Starters. MS 116, MS 325, MS 4xx

Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays

Short form catalogue Motor protection and control Manual motor starters

KT4 Manual Motor Starter

Control Circuit Protection

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

A302DN.40/.63A Thermal Current Motor Starter

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Protection Equipment. 5/2 Introduction

Technical Catalogue. Manual Motor Starters MS116, MS325, MS4xx ABB

System pro M compact Miniature Circuit Br eakers Description Features

Technical data OT16E3 OT160E3 UL & CSA

Ideal for use as a manual starter

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

Technical Information

Contactors. Contactors ensure positive safety between their auxiliary contact blocks. Easy coil change Captive terminal screws

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

Product Specification Sheet #3LD2.1

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Manual Motor Starters. Meta-MEC

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers

AF series contactors (9 2650)

XT IEC Power Control Manual Motor Protectors

MS General Information Extended Product Type: MS

AF series contactors (9 2650)

Miniature Circuit Breaker UL / CSA Range

C E R T I F I C A T E O F C O M P L I A N C E

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Short form catalogue. Motor protection & control

Bulletin 190-M Compact Starters. Selection Guide

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Self-protected Combination Starters System PKZ 2-SP

System pro M compact Modular DIN rail components E220 - E270 Series

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

Selection Guide Motor Control Device Solutions

Bulletin 140M Motor Protectors

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Description. Positive safety relays

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Tmax Molded Case Circuit Breakers

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

MCBs S260 S290. Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description. Features

UMBW-UL489 and UL1077 Listed

FMotor Circuit Controllers & Circuit Breakers

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

US CATALOG. Miniature Circuit Breakers

FMotor Circuit Controllers

4 - Miniature controls

Short-Circuit Current Ratings

US CATALOG. Miniature circuit breakers

AF40... AF96 3-pole contactors Technical data

j~åì~ä=jçíçê=pí~êíéêë=~åç jçíçê=pí~êíéê=`çãäáå~íáçåë 7.5 kw) Economic solution up to 7.5 kw thanks to small fuseless protection = =

Protection Equipment

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Motor Starter Protectors

1489-M Circuit Breakers

New Dimension in Motor Protection Manual Motor Starter MS116

Softstarters. Softstarters Power electronic brakes Type PEB

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Motor Starter Protectors

D509E. Manual Motor - Starters

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

Low voltage switch gear

Product Line Overview. The Most Logically Designed Contact Assembly

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

Section Contents. Disconnect Switches

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

UL 508 Non-Fusible Disconnect Switches

Motor Circuit Breakers C4

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Transcription:

Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and CSA certifi ed for Group Motor Installations 12 Setting ranges from 0.1 to 16 amps. Up to 30kA or 0kA with no back up fuse required 3mm DIN rail snap-on mounting Wide range of accessories Type MS32 Suitable for use with 3-phase motors up to 1 HP @ 480V UL ed and CSA certifi ed for Group Motor Installations 12 Setting ranges from 0.1 to 2 amps. Up to 0kA or 100kA with no back up fuse required 3mm DIN rail snap-on mounting Wide range of accessories Type MS4x Suitable for use with 3-phase motors up to 40 HP @ 480V UL ed and CSA certifi ed for Group Motor Installations 14 Setting ranges from 11 to 0 amps Up to 100kA with no back up fuse required 3mm DIN rail snap-on mounting Wide range of accessories Type MS49x Suitable for use with 3-phase motors up to 7 HP @ 480V UL ed and CSA certifi ed for Group Motor Installations 22 Setting ranges from 11 to 100 amps Up to 100kA with no back up fuse required 3mm DIN rail snap-on mounting Wide range of accessories Single motor applications Single motor applications employing a manual motor protector (MMP) result in a simple, compact and economical alternative to conventional magnetic motor controllers for manual operation of a single motor. Upstream short circuit and overcurrent protection in the form of fuses or a circuit breaker is required but the MMP can replace the overload relay, contactor and associated electrical components and wiring for controlling the contactor. Group motor applications Group motor installations offer several advantages when controlling two or more motors or other loads over conventional single motor starters. Several MMPs can be grouped together and fed from a single set of fuses or a circuit breaker. These devices can be installed together on a single DIN rail and fed power through three phase insulated busbars and a power feed terminal. Protecting this group of MMPs is a single circuit breaker or fusible switch, sized specifi cally for the load. Excellent coordination and short circuit protection can be achieved, as high as 0kAIC, when using the MS32 product in this manner. Close coupling adapters are offered to connect contactors to the load side of each MMP for automatic operation of each motor. If a single motor experiences an overload, the associated MMP trips and allows the other motors to continue running. Numerous accessories are available for signaling in the event of a trip, to indicate status, to provide shunt trip and for undervoltage release. The main benefi ts of group installation are quick, fool proof assembly, minimal wiring and a reduction of the necessary enclosure size. The only constraint is that the upstream circuit protective device must be sized specifi cally for the load a highly desirable feature in order to provide the closest coordination and the greatest level of circuit protection. Article 430.3(C) of the NEC specifi es the requirements for group motor installations; all ABB MMPs meet these requirements. Low Voltage Products & Systems.1 ABB Inc. 888-38-1221 www.abb-control.com

Manual motor protectors General information Selection Group installation is an approach to building multi-motor control systems in accordance with Section 430-3 of the National Electrical Code. The selection of components used in group installations is a simple process which consists of several steps. First is the selection of the appropriate fuse as Branch Circuit Protective Device (BCPD). Second is the selection of the appropriate motor starter and protector. Third, the selected MMP must be checked for UL listing with the selected BCPD and the available short circuit current at the application location. 1. Fused disconnect Calculate maximum fuse size according to NEC 430-3 (c). I max (fuse size) = 17% x FLC (full load current for largest motor) + the sum of FLC (full load current for largest motor) + the sum of FLC values for other motors on that branch using NEC Table 430-10 on the right. Select fuse from NEC Table 240-6 below. Where I max falls between two fuse ampere ratings NEC 430-3 (c) permits going to the next high ampere rating. 2. Motor protector selection Select the proper MMP catalog for each motor load from the following pages based on the actual motor full load current (FLA) using the Thermal setting range column for reference. 3. MMP Interruption ratings Using the interruption ratings table on the next page, identify the system application voltage and interrupting capacity for the type of fuse selected in step 1 above. NEC 240-6 Standard fuse amperes 1, 20, 2, 30, 40, 4, 0, 60, 70, 80, 90, 110, 12, 10, 17, 200, 22, 20, 300, 30, 400, 40, 00, 600, 700, 800, 1000, 1200, 1600 Examples: Select components for protecting the following 3-phase, 460VAC, squirrel cage induction motors. The nameplate data are: 1/2 HP, 1.0 FLA; 3 HP, 4.8 FLA; HP, 7.6 FLA; 7. HP, 11 FLA; 10 HP, 14 FLA. Example: using fused disconnect I max = 17% x 14 + (11 + 7.6 + 4.8 + 1) = 48.9A Fuse rating using Table NEC 240-6 = 0A Minimum disconnect size = 11% x Total FLA NEC 430-10 table = 11% x (14+ 11 + 7.6 + 4.8 + 1) = 44.16 Disconnect for 0A fuses is ok. NEC Table 430-10 full load current, 3ph AC motor Horsepower Induction type squirrel cage & wound rotor 1 230V 460V 7V amps amps amps 1/2 2 1.8 3/4 2.8 1.4 1.1 1 3.6 1.8 1.4 1..2 2.6 2.1 2 6.8 3.4 2.7 3 9.6 4.8 3.9 1.2 7.6 6.1 7. 22 11 9 10 28 14 11 1 42 21 17 20 4 27 22 2 68 34 27 Note: Refer to NEC 310-1 and NEC 430-3(d) for cable sizing. For full load currents of 208 and 200 volt motors, increase the corresponding 230 volt motor full-load current by 10% and 1%, respectively. MS32 data Motor rating at 460V Horsepower FLA, AC3 MS32 1/2 1.0 MS32-1.0 A9C 3 4.8 MS32-6.3 A9C 7.6 MS32-9.0 A9C 7. 11 MS32-12. A12C 10 14 MS32-16 A16C Contactor INCOMING LINES A B C ISOMAX MCCB or Fusible Switch (If specified) 1 3 1 3 1 3 1 3 1 3 I> I> I> 2 4 6 1M I> I> I> 2 4 6 2M I> I> I> 2 4 6 3M I> I> I> 2 4 6 4M I> I> I> 2 4 6 M L1 L2 L3 1C L1 L2 L3 2C L1 L2 L3 3C L1 L2 L3 4C L1 L2 L3 C T1 T2 T3 T1 T2 T3 T1 T2 T3 T1 T2 T3 T1 T2 T3 MOTOR MOTOR MOTOR MOTOR MOTOR 1 These values of full-load current are for motors running at speeds usual for belted motors and motors with normal torque characteristics. Motors built for especially low speeds or high torques may require more running current, and multispeed motors will have full-load current varying with speed, in which case the nameplate current rating shall be used. The voltage listed are rated motor voltages. The currents listed shall be permitted for system voltage ranges of 110 to 120, 220 to 240, 440 to 480, and 0 to 600 volts..2 Low Voltage Products & Systems ABB Inc. 888-38-1221 www.abb-control.com

Type MS116 Manual motor protectors MS116 Manual motor protectors Thermal setting Single-phase 3-phase range (Amps) horsepower ratings 1 horsepower ratings 120V 240V 240V 480V 600V MS116 0.10 0.16 MS116-0.16 0.16 0.2 MS116-0.2 $ 129 0.2 0.40 MS116-0.40 0.40 0.63 MS116-0.63 0.63 1.0 1/2 1/2 MS116-1.0 1.0 1.6 1/10 3/4 3/4 MS116-1.6 1.6 2. 1/6 1/2 1 1. MS116-2. 148.0 2. 4.0 1/8 1/3 1 2 3 MS116-4.0 4.0 6.3 1/4 1/2 1. 3 MS116-6.3 6.3 10 1/2 1. 3 7. MS116-10 8.0 12 1/2 2 3 7. 10 MS116-12 172.0 10.0 16 1 2 10 10 MS116-16 UL File # E137861 1 Single phase motor ratings are based upon wiring all three poles in series. Low Voltage Products & Systems Discount schedule MA.3 ABB Inc. 888-38-1221 www.abb-control.com

Manual motor protectors Type MS116 Accessories Auxiliary contact blocks for Type MS116 (side mount) Contact confi guration 1 NO & 1 NC HK1-11 2 NO HK1-20 $ 33 2 NC HK1-02 Auxiliary contact blocks for Type MS116 (front mount) Contact confi guration 1 NO & 1 NC HKF1-11 $ 33 HK1-11 HKF1-11 Bell alarm contact blocks for Type MS116 Contact confi guration Undervoltage trip for Type MS116 1 NO & 1 NC SK1-11 2 NO SK1-20 $ 33 2 NC SK1-02 Voltage (VAC) 24 UA1-24 48 UA1-48 60 UA1-60 120 UA1-120 $ 82.0 230 UA1-230 400 UA1-400 41 UA1-41 SK1-11 UA1-120 Undervoltage trip with 1NO & 1NC auxiliary contact for Type MS116 Voltage (VAC) 24 UA1-HK-24 48 UA1-HK-48 60 UA1-HK-60 120 UA1-HK-120 $ 97.0 230 UA1-HK-230 400 UA1-HK-400 41 UA1-HK-41 Locking device for Type MS116 Description Adaptor for padlock Type SA1 MS32-SA1 $ 1 Complete padlock locking kit (adaptor, padlock & 3 keys) MS32-SA3 37.0 OTPA116 Molded plastic enclosures for Type MS116 Item Protection description level Gray enclosure with black handle IP64 OTPA116L2P1 $ 7 Yellow enclosure with red handle IP64 OTPA116A2P1 7 Gray enclosure with clear cover, 4 module IP 12644 84 Gray enclosure with clear cover, 6 module IP 12646 98 Plastic adaptors for enclosures for Type MS116 Description PG16 to 1/2NPT PG16-1/2NPT $ 10 12644 Shunt trip for Type MS116 Voltage (VAC) 24V AA1-24 110V AA1-110 200 240V AA1-230 30 41V AA1-400 $ 7.4 Discount schedule MA Manual motor protectors Low Voltage Products & Systems Discount schedule H6 Handles, shafts & accessories ABB Inc. 888-38-1221 www.abb-control.com

Type MS116 Accessories Manual motor protectors OHB2AJ Door mounting hardware for for Type MS116 1 Description Power feed terminal blocks for Type MS116 Description for 4 AWG wire for busbar S1-M1 S1-M2 Shaft coupler MSMN $ 1 NEMA 1, 3R, 12 Black selector handle OHB2AJ 30 NEMA 1, 3R, 12 Red, yellow selector handle OHY2AJ 30 4.1 length shaft OXSX10 4 7.1 length shaft OXSX180 6 $ 24 S1-M1 PS1-2-1 S1-M2 Busbars for Type MS116 Description for 2 devices without auxiliary contacts PS1-2-0 $ 24 for 3 devices without auxiliary contacts PS1-3-0 30 for 4 devices without auxiliary contacts PS1-4-0 36 for devices without auxiliary contacts PS1--0 42 for 2 devices with 1 auxiliary contact PS1-2-1 24 for 3 devices with 1 auxiliary contact PS1-3-1 30 for 4 devices with 1 auxiliary contact PS1-4-1 36 for devices with 1 auxiliary contact PS1--1 42 for 2 devices with 2 auxiliary contacts PS1-2-2 24 for 3 devices with 2 auxiliary contacts PS1-3-2 30 for 4 devices with 2 auxiliary contacts PS1-4-2 36 for devices with 2 auxiliary contacts PS1--2 42 Busbar for direct mounting of contactors Description B6/B7 BEA7/116 $ 12 A9/A12/A16 BEA16/116 13.0 A26 BEA26/116 1 S1- M2 PS1-4-1 S1- M2 PS1-... PS1-... SK1-... HK1-... SA1 UA1-... HKF1-11 HK1-... HK1-... 1 Must have shaft coupler, handle and shaft for through-the-door operation. Low Voltage Products & Systems Discount schedule MA Manual motor protectors. ABB Inc. 888-38-1221 www.abb-control.com Discount schedule H6 Handles, shafts & accessories

Manual motor protectors Type MS116 Technical data Softstarter type MS116 Standards, approvals UL, CSA, CE Rated operating current A 16 Current range A 0.16 16 Number of poles 3 Frequency Hz 0 / 60 Tripping class A 10 Max. kaic & 600V kaic 30 Mechanical life Operations 100,000 Wire range AWG 12 18 Terminal torque in. lbs. 14 Terminal tool options Flat screwdriver PZ2 Permissible attitude without derating m 3000 Degree of protection IP20 UL ed for group installation Yes Self-protected Type E manual combination starter No Accessories Terminal shroud No Auxiliary contacts Yes Shunt trip No Trip signal contacts Yes UV release Yes Busbar Yes Through the door handle Yes Minimum enclosure size H x W x D Loads for accessories Auxiliary contact for front mounting, HKF AC1 24 V, 3.0 A 230 V, 1. A Auxiliary contact for front mounting, HKF DC13 24 V, 1.0 A 48 / 60V, 0.7 A 110 V, 0.27 A Auxiliary and signal contact, HK + SK AC1 24 V, 6 A 230 V, 4 A 400 V, 3 A Auxiliary and signal contact, HK + SK DC13 24 V, 2 A 110 V, 0. A 220 V, 0.2 A 440 V, 0.1 A Electromagnet trips Response value set ex-works 9.6 14.4 x In Undervoltage release Pick-up value % of U C 8 Drop-out value % of U C 3 7 Power consumption Pick-up VA Consult factory Hold VA Consult factory Short-circuit protection MS 116 Setting ranges, short-circuit strength and max. back-up fuses Maximum rated current of the short-circuit fuses if I cc >I cs at at at at at from to 230 V AC 400 V AC 440 V AC 00 V AC 690 VAC I cu I cs gl, gg I cu I cs gl, gg I cu I cs gl, gg I cu I cs gl, gg I cu I cs gl, gg A A ka ka A ka ka A ka ka A ka ka A ka ka A Setting ranges 0.1... 0.16 to Short-circuit proof up to I cc =0kA Short-circuit proof up to I cc =30kA 1.0... 1.6 1.6... 2. 10 10 2 10 10 2 2 2.... 4.0 6 6 2 6 6 2 2 2 2 4.0... 6.3 6 6 63 6 6 63 2 2 40 6.3... 10.0 6 6 63 6 6 63 2 2 0 8.0... 12.0 2 2 80 2 2 80 6 6 63 6 6 63 2 2 0 10.0... 16.0 16 16 80 16 16 80 4 4 63 4 4 63 2 2 63.6 Low Voltage Products & Systems ABB Inc. 888-38-1221 www.abb-control.com

Type MS116 Technical data Manual motor protectors General purpose MS116 range Maximum current (600 VAC Max.) 0.1 0.16 0.16 0.16 0.2 0.2 0.2 0.40 0.40 0.04 0.63 0.63 0.63 1.0 1.0 1.0 1.6 1.6 1.6 2. 2. 2. 4.0 4.0 4 6.3 6.3 6.3 10 10 8 12 12 10 16 16 Short circuit ratings 18,000 RMS symmetrical 480 VAC,000 RMS symmetrical 600 VAC Maximum ratings Horsepower, HP, Breaking-All-Lines MS116 Single phase Three phase Range 0/60 Hz 0/60 Hz 120 VAC 240 VAC 240 VAC 480 VAC 600 VAC 0.1 0.16 0.16 0.2 0.2 0.40 0.40 0.63 0.63 1.0 1/2 1/2 1.0 1.6 1/10 3/4 3/4 1.6 2. 1/6 1/2 1 1 1/2 2. 4.0 1/8 1/3 1 2 3 4.0 6.3 1/4 1/2 1 1/2 3 6.3 10 1/2 1 1/2 3 7 1/2 8 12 1/2 2 3 7 1/2 10 10 16 1 2 10 10 Low Voltage Products & Systems.7 ABB Inc. 888-38-1221 www.abb-control.com

Manual motor protectors Type MS116 Approximate dimensions MS116 MS116 mounted with A9 - A16 contactor MS116 mounted with B6/B7 minicontactor 4 8,6 8.6 4 8.6 177 HKF1-11 19 HKF1-11 BEA16/116 BEA7/116 A9... A16 B6 / B7 47. 47 7 2 MS116 mounted with UA1..., SK!..., HK1..., HKF1-11 18 9 9 UA1-... SK1-... HK1-... 90 HKF1-11 81 8.6.8 Low Voltage Products & Systems ABB Inc. 888-38-1221 www.abb-control.com

Type MS116 Approximate dimensions Manual motor protectors Molded plastic enclosures for MS116 OTPA116L2P1 and OTPA116A2P1 12644 12646 4.92 12 4.13 10 4.92 12 4.92 12 4.13 10 6.30 160 7.09 180 7.09 180 Low Voltage Products & Systems.9 ABB Inc. 888-38-1221 www.abb-control.com

Manual motor protectors Type MS32 MS32-1.0 Manual motor protectors Type MS32 Thermal setting Single-phase 3-phase range horsepower ratings 1 horsepower ratings (Amps) 120V 240V 240V 480V 600V 0.10 0.16 MS32-0.16 0.16 0.2 MS32-0.2 $ 144 0.2 0.40 MS32-0.40 0.40 0.63 MS32-0.63 0.63 1.0 1/2 1/2 MS32-1.0 1.0 1.6 1/10 3/4 3/4 MS32-1.6 1.6 2. 1/6 1/2 1 1. MS32-2. 16 2. 4.0 1/8 1/3 1 2 3 MS32-4.0 4.0 6.3 1/4 1/2 1. 3 MS32-6.3 6.3 9.0 1/3 1 2. 7. MS32-9.0 9.0 12. 1/2 2 3 7. 10 MS32-12. 192 12. 16 1 2. 10 10 MS32-16 16 20 1. 3 10 1 MS32-20 211.0 20 2 2 3 7. 1 20 MS32-2 223.0 MS32 UL File #E137861 Accessories UL File #E9033 ➀ Single phase motor ratings are based upon wiring all three poles in series..10 Discount schedule MA Low Voltage Products & Systems ABB Inc. 888-38-1221 www.abb-control.com

Type MS32 Accessories Manual motor protectors MS32-HK11 Auxiliary contact blocks for Type MS32 (side mount) Auxiliary contact blocks for Type MS32 (front mount) Bell alarm contact blocks for Type MS32 1 NO & 1 NC MS32-HK11 2 NO MS32-HK20 $ 33 2 NC MS32-HK02 1 NO & 1 NC MS32-HKF11 2 NO MS32-HKF20 1 NO MS32-SK10 1 NC MS32-SK01 $ 33 $ 33 MS32-HKF11 Shunt trips for Type MS32 110 240 VAC/VDC, 60 Hz MS32-ST110 24 60 VAC/DC, 60 Hz MS32-ST24 $ 82.0 MS32-UA24 Undervoltage trip for Type MS32 24V MS32-UA24 48V MS32-UA48 60V MS32-UA60 110V MS32-UA110 $ 82.0 230V MS32-UA230 400V MS32-UA400 41V MS32-UA41 480V MS32-UA480 Remote control unit MS32-AS Electrically operated remote control unit for MS32. For use up to MS32-16 and below. Not for use with MS32-20 & MS32-2. Provided with 1 NO & 1 NC auxiliary contacts and 1NO trip signal contacts NOTE: May not be used with HFK, SK, ST or UV accessories 24V AC/DC RC32-24V 48V AC/DC RC32-48V 60V AC/DC RC32-60V $ 16 110V AC/DC RC32-110V 230V AC/DC RC32-230V MS32-SA1 MS32-SA3 Supporting terminal for Type MS32 for UA or as N/LS clamp MS32-AS $ 1 Padlocking devices for Type MS32 Adapter for padlock type SA1 MS32-SA1 $ 1 Complete padlock kit (includes adaptor, padlock & 3 keys) MS32-SA3 37.0 Low Voltage Products & Systems Discount schedule MA.11 ABB Inc. 888-38-1221 www.abb-control.com

Manual motor protectors Type MS32 Accessories Switch cublicle mounting kit Molded plastic enclosures for Type MS32 Item Protection description level Light gray enclosure with black handle IP64 OTPA32B2P1 $ 7 Light gray enclosure with red/yellow handle IP64 OTPA32A2P1 7 Gray enclosure w/clear lid, 4 module IP 12644 84 Gray enclosure w/clear lid, 6 module IP 12646 98 NOTE: Use Discount schedule MA for IP64 enclosures ; use Discount schedule CB8 for IP enclosures. Plastic adaptors for enclosures for Type MS32 PG16 TO 1/2 NPT PG16-1/2 NPT $ 10 MS32-BB1 Selector handles for through-the-door operation for Type MS32 1 Shaft coupler MSMN $ 1 NEMA 1, 3R, 12 black selector handle OHB2AJ 30 NEMA 1, 3R, 12 red/yellow selector handle OHY2AJ 30 4.1 length shaft OXSX10 4 7.1 length shaft OXSX180 6 NOTE: Use Discount schedule MA for shaft coupler; use Discount schedule H6 for handles and shafts. Power feed terminal blocks for Type MS32 Standard, accepts 4 AWG wire MS32-SM1 $ 24 Low profi le, accepts 4 AWG wire MS32-BB1 2.0 MS32-SM1 PS3-2-0 PS3-4-0 Busbars for Type MS32 2 for 2 devices; without auxiliary switch PS3-2-0 $ 24 for 3 devices; without auxiliary switch PS3-3-0 30 for 4 devices; without auxiliary switch PS3-4-0 33 for devices; without auxiliary switch PS3--0 39 for 2 devices; with 1 auxiliary switch PS3-2-1 30 for 3 devices; with 1 auxiliary switch PS3-3-1 34.0 for 4 devices; with 1 auxiliary switch PS3-4-1 37.0 for devices; with 1 auxiliary switch PS3--1 42 for 2 devices; with 2 auxiliary switches PS3-2-2 30 for 4 devices, with 2 auxiliary switches PS3-4-2 37.0 Busbars can be daisy chained to connect additional MS32s. Close coupling adapters Device MS32 + B6/B7 contactor BEA7/32 MS32 + VB6/VB7 reversing contactor MS32-VB7 $ 12 MS32 + A9, A12, A16 contactor BEA16/32 13.0 MS32 + A26 contactor BEA26/32 1 MS32 coupled to mini-contactor 1 Must have shaft coupler, handle and shaft for through-the-door operation. 2 UL fi le # E16720; CSA fi le# LR98427M7-11.12 Discount schedule MA Manual motor protectors & accessories Discount schedule H6 Handles, shafts & accessories Low Voltage Products & Systems Discount schedule CB8 IP plastic enclosures ABB Inc. 888-38-1221 www.abb-control.com

Type MS32 Accessories DLA starters, non-reversing Manual motor protectors + = MS32-6.3 DLA9-30-84 DLA starter Manual motor protectors MS32 Single-phase 3-phase Thermal setting horsepower ratings 1 horsepower ratings DLA module range (amps) catalog 120V 240V 240V 480V 600V 0.10 0.16 MS32-0.16 0.16 0.2 MS32-0.2 0.2 0.40 MS32-0.40 $ 144 0.40 0.63 MS32-0.63 0.63 1.0 1/2 1/2 MS32-1.0 DLA9-30-84 $ 117 1.0 1.6 1/10 3/4 3/4 MS32-1.6 1.6 2. 1/6 1/2 1 1. MS32-2. 16 2. 4.0 1/8 1/3 1 2 3 MS32-4.0 4.0 6.3 1/4 1/2 1. 3 MS32-6.3 6.3 9.0 1/3 1 2. 7. MS32-9.0 DLA9-30-84 117 9.0 12. 1/2 2 3 7. 10 MS32-12. 192 DLA12-30-84 131 12. 16 1 2. 10 10 MS32-16 DLA16-30-84 13 16 20 1. 3 10 1 MS32-20 211.0 DLA16-30-84 13 20 2 2 3 7. 1 20 MS32-2 223.0 DLA26-30-84 234 General information The construction of DLA starters is based on ABB A-Line contactors. The mounting plate, including a built-in A contactor, is designed to integrate an ABB manual motor starter type MS32. Starters can be easily made with protection against overloads and short-circuits (Type I or Type II coordination). The technical characteristics of these devices are identical to A-Line contactors. The advantages are as follows: Simplifi ed installation: DLA starters mount onto 3 x 1 mm DIN rail (EN 0022). Direct mounting of manual motor starter MS32 Contactor coil terminals accessible on lower side. High performance as a result of this combination of the MS32 manual motor starter with high breaking capacitiy and the new A-Line contactor ensuring high electrical durability. Accessory types on the manual motor starter: Set of bus bars, external operating mechanism, padlock holder, auxiliary contact, undervoltage coil, shunt trip, etc. Coil voltage selection All AC operated catalog s include a 120VAC coil. To select other coil voltages, substitute the code from the Coil voltage selection chart for the two digits after the last dash in the catalog. AC coils only. Ex.: A 240V coil is required for a DLA9 starter: DLA9-30-80 Ordering instructions The MS32 manual motor starters and the DLA module must be ordered separately and assembled by customer. Accessories for DLA starters Accessories for DLA starters are the same as for the individual contactors and manual motor protectors. Coil voltage selection chart Volts Hz 12 24 48 110 120 220 240 380 41 440 60 81 83 84 84 80 86 86 0 81 83 84 80 8 86 For other AC voltages, see page 1.13 1 Single phase motor ratings are based upon wiring all three poles in series. 2 In group motor applications, use the lowest maximum fuse or MCCB size. Low Voltage Products & Systems Discount schedule MA MS32.13 ABB Inc. 888-38-1221 www.abb-control.com Discount schedule AA DLA

Manual motor protectors Type MS32 Accessories WLA starters, reversing + = MS32-1.0 WLA9-30-84 WLA... Manual motor protectors Single-phase 3-phase Thermal setting horsepower ratings 1 horsepower ratings Reversing DLA range (amps) module catalog 120V 240V 240V 480V 600V MS32 0.10 0.16 MS32-0.16 0.16 0.2 MS32-0.2 0.2 0.40 MS32-0.4 $ 144 0.40 0.63 MS32-0.63 0.63 1.0 1/2 1/2 MS32-1.0 WLA9-30-84 $ 294 1.0 1.6 1/10 3/4 3/4 MS32-1.6 1.6 2. 1/6 1/2 1 1. MS32-2. 16 2. 4.0 1/8 1/3 1 2 3 MS32-4.0 4.0 6.3 1/4 1/2 1. 3 MS32-6.3 6.3 9.0 1/3 1 2. 7. MS32-9.0 WLA9-30-84 294 9.0 12. 1/2 2 3 7. 10 MS32-12. 192 WLA12-30-84 422 12. 16 1 2. 10 10 MS32-16 WLA16-30-84 464 16 20 1. 3 10 1 MS32-20 211.0 WLA16-30-84 464 20 2 2 3 7. 1 20 MS32-2 223.0 WLA26-30-84 31 Coil voltage selection All AC operated catalog s include a 120VAC coil. To select other coil voltages, substitute the code from the Coil voltage selection chart for the two digits after the last dash in the catalog. AC coils only. Ex.: A 240V coil is required for a DLA9 starter: DLA9-30-80 Ordering instructions The MS32 manual motor starters and the DLA module must be ordered separately and assembled by customer. Accessories for DLA starters Accessories for DLA starters are the same as for the individual contactors and manual motor protectors. Coil voltage selection chart Volts Hz 12 24 48 110 120 220 240 380 41 440 60 81 83 84 84 80 86 86 0 81 83 84 80 8 86 For other AC voltages, see page 1.13 1 Single phase motor ratings are based upon wiring all three poles in series. 2 In group motor applications, use the lowest maximum fuse or MCCB size..14 Discount schedule MA MS32 Low Voltage Products & Systems Discount schedule AA WLA ABB Inc. 888-38-1221 www.abb-control.com

Type MS40 MS497 Manual motor protectors MS40 MS497 Manual motor starters FLA adjustment range Horsepower ratings Single-phase1 Three-phase 11V 230V 200V 208V 230V 460V 7V Weight Availability (lbs) code MS40 11 16 1 3 10 1 2.12 A MS40-16 $ 40 14 20 1. 3 7. 1 20 2.12 A MS40-20 40 18 2 2 7. 10 20 2 2.12 A MS40-2 40 22 32 3 10 10 2 30 2.12 A MS40-32 40 28 40 3 7. 1 1 30 40 2.12 A MS40-40 10 36 4 7. 1 1 30 40 2.12 A MS40-4 10 40 0 10 1 20 40 0 2.12 A MS40-0 10 MS49 28 40 3 7. 1 1 30 40 4.63 A MS49-40 62.0 36 0 10 1 20 40 0 4.63 A MS49-0 62.0 4 63 1 20 2 0 60 4.63 A MS49-63 62.0 7 7 7. 1 2 2 60 7 4.63 A MS49-7 600 70 90 10 20 30 30 7 100 4.63 A MS49-90 61 80 100 10 2 40 40 7 100 4.63 A MS49-100 690 MS497 11 16 1 3 10 1 2.12 B MS497-16 40 14 20 1. 3 7. 1 20 2.12 B MS497-20 40 18 2 2 7. 10 20 2 2.12 B MS497-2 40 22 32 3 10 10 2 30 2.12 B MS497-32 40 28 40 3 7. 1 1 30 40 4.63 B MS497-40 62.0 36 0 10 1 20 40 0 4.63 B MS497-0 62.0 4 63 20 2 0 60 4.63 B MS497-63 62.0 7 7 7. 2 2 60 7 4.63 B MS497-7 600 70 90 10 30 30 7 100 4.63 B MS497-90 61 80 100 10 30 40 7 100 4.63 B MS497-100 690 MS41 11 16 1 3 10 1 2.12 B MS41-16 40 14 20 1. 3 7. 1 20 2.12 B MS41-20 40 18 2 2 7. 10 20 2 2.12 B MS41-2 40 22 32 3 10 10 2 30 2.12 B MS41-32 40 28 40 3 7. 1 1 30 40 2.12 B MS41-40 10 36 4 7. 1 1 30 40 2.12 B MS41-4 10 40 0 10 1 20 40 0 2.12 B MS41-0 10 MS496 28 40 3 7. 1 1 30 40 4.63 B MS496-40 62.0 36 0 10 1 20 40 0 4.63 B MS496-0 62.0 4 63 1 20 2 0 60 4.63 B MS496-63 62.0 7 7 7. 1 2 2 60 7 4.63 B MS496-7 600 70 90 10 20 30 30 7 100 4.63 B MS496-90 61 80 1002 10 2 40 40 7 100 4.63 B MS496-100 690 Availability code A Standard item, stock to two weeks lead time B Stock to four weeks lead time C 4 to 6 weeks lead time UL File # E16720 Overload tripping class 10 Overload tripping class 20 1 Single phase motor ratings are based upon wiring all three poles in series. 2 Maximum motor current 9A. Low Voltage Products & Systems Discount schedule MA.1 ABB Inc. 888-38-1221 www.abb-control.com

Manual motor protectors Type MS40 MS497 for UL 08 Type E Applications MS40-16E MS497-16E Manual motor starters Overload tripping class 10 Overload tripping class 20 FLA adjustment range Horsepower ratings Single-phase1 Three-phase 11V 230V 200V 208V 230V 460V 7V Weight Availability 3 (lbs) code MS40 11 16 1 3 10 1 2.12 A MS40-16E $ 2 14 20 1. 3 7. 1 20 2.12 A MS40-20E 2 18 2 2 7. 10 20 2 2.12 A MS40-2E 2 22 32 3 10 10 2 30 2.12 A MS40-32E 2 28 40 3 7. 1 1 30 40 2.12 A MS40-40E 8 36 4 7. 1 1 30 40 2.12 A MS40-4E 8 40 0 10 1 20 40 0 2.12 A MS40-0E 8 MS49 28 40 3 7. 1 1 30 40 4.63 A MS49-40E 622.0 36 0 10 1 20 40 0 4.63 A MS49-0E 622.0 4 63 1 20 2 0 60 4.63 A MS49-63E 622.0 7 7 7. 1 2 2 60 7 4.63 A MS49-7E 720 70 90 10 20 30 30 7 100 4.63 A MS49-90E 73 80 100 10 2 40 40 7 100 4.63 A MS49-100E 810 MS497 11 16 1 3 10 1 2.12 B MS497-16E 70 14 20 1. 3 7. 1 20 2.12 B MS497-20E 70 18 2 2 7. 10 20 2 2.12 B MS497-2E 70 22 32 3 10 10 2 30 2.12 B MS497-32E 70 28 40 3 7. 1 1 30 40 4.63 B MS497-40E 622.0 36 0 10 1 20 40 0 4.63 B MS497-0E 622.0 4 63 20 2 0 60 4.63 B MS497-63E 622.0 7 7 7. 2 2 60 7 4.63 B MS497-7E 720 70 90 10 30 30 7 100 4.63 B MS497-90E 73 80 100 10 30 40 7 100 4.63 B MS497-100E 810 MS41 11 16 1 3 10 1 2.12 B MS41-16E 2 14 20 1. 3 7. 1 20 2.12 B MS41-20E 2 18 2 2 7. 10 20 2 2.12 B MS41-2E 2 22 32 3 10 10 2 30 2.12 B MS41-32E 2 28 40 3 7. 1 1 30 40 2.12 B MS41-40E 8 36 4 7. 1 1 30 40 2.12 B MS41-4E 8 40 0 10 1 20 40 0 2.12 B MS41-0E 8 MS496 28 40 3 7. 1 1 30 40 4.63 B MS496-40E 622.0 36 0 10 1 20 40 0 4.63 B MS496-0E 622.0 4 63 1 20 2 0 60 4.63 B MS496-63E 622.0 7 7 7. 1 2 2 60 7 4.63 B MS496-7E 720 70 90 10 20 30 30 7 100 4.63 B MS496-90E 73 80 1002 10 2 40 40 7 100 4.63 B MS496-100E 810 Availability code A Standard item, stock to two weeks lead time B Stock to four weeks lead time C 4 to 6 weeks lead time 1 Single phase motor ratings are based upon wiring all three poles in series. 2 Maximum motor current 9A. 3 includes all parts required for UL08/E applications..16 Discount schedule MA Low Voltage Products & Systems ABB Inc. 888-38-1221 www.abb-control.com