ENR Incorporating

Similar documents
TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

technical catalogue tetris KW Chiller and heat pumps air/water

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

CWP-CO / CWP-RC / CWP-HP 02 to 35

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

CATÁLOGO TÉCNICO COMERCIAL

AQWL/AQWH/AQWR 1404 to 2406

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw

R134a Water Cooled Chillers. WCWWXT/Y Series ( Ton)

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

Y-Flow TCHEY-THHEY

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

WQL/WQH/WQRC 524 to 1204

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

Reversible air-to-water scroll heat pumps

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

AQVSL/AQVSH STAR 85 to 140

VHA. Air cooled chiller with

AZURA. Air/water multifunctional chiller&heat pump, kw

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

DIMENSION AND SELECTION GUIDE

LDA LDA. Air cooled water chillers with axial fans VERSIONS R410A

LHA LHA A ++ High efficiency air to water heat pumps EVI EVI EVI DC. Versions

ZETA ECHOS. Chillers and heat pumps Air/water kw. General Air/Water chillers and heat pumps with axial fans and hermetic scroll compressors.

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Air-Cooled Liquid Chiller with integrated hydraulic module

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series

UMXCA/UMXCBA ECVA/ECVBA

OMICRON V EVO. Multifunctional unit

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

TEAL FCTM. Chiller with integrated Free Cooling system chillers and heat pumps, kw

Epsilon Echos DK kw

30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER

AHN 064 to 304 EHN/CHN 064 to 304

Product Catalog TSE Series Scroll Central Chillers

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans.

Product Catalog TSE Series Scroll Central Chillers

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

CGA CXA VGA VXA CG-PRC006-E4

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

AIR COOLED CHILLERS WATER COOLED CHILLERS

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

WCA4**4. Product Specifications

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

application guide axial condensing units

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK

CONTINUOUS CAPACITY CONTROL MODELS

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension

RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

PRODUCT CATALOGUE CHILLER ECOMAX

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

CXAM. Options. Accessories

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

CHILLER START UP PROCEDURE FORM DOC. N (DOC.N BELOW TO BE RETURN TO AERMEC)

FOCS. Climaveneta Technical Bulletin. Air-cooled water chiller with helical fans kw

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

RCD Air Cooled Condensing Unit (50/60 Hz)

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Inverter air to water heat pumps

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

Chillers. EWAD-C- 620~1860 kw. Air-cooled R-134a. » Wide capacity range (620 kw kw) » Multiple efficiency and sound versions

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

Index Features and advantages... 3 General characteristics... 5 Nomenclature Technical specifications... 11

Multi-pipe units with scroll compressors

Air cooled chillers With axial fans and power ratings from 238 to 1600 kw with two-screw compressor

NECS-WQ. Climaveneta Technical Bulletin NECS_WQ_0152_1604_201006_GB. INTEGRA unit for 4-pipe systems, water source ,6-522 kw

YH Series Scroll Compressors With Dual-Compliance For A/C and Chiller

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options.

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

... RTU Technical Manual. Packaged Air Conditioning Unit...

ED.X Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS. COOLING CAPACITY FROM 6,7 TO 138 kw. ED.X 331 U Kc

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

Air/Water chillers for outdoor installation Screw compressors, shell and tube heat exchangers and axial fans Cooling capacity kW 1402/9603

TSA6. Product Specifications. SmartComfort TXC 5600

Water Source Heat Pump P 34 P 35. Features. Optional. Instruction of model. Water-Cooled Screw Chiller

TEAL FC. Chiller with integrated Free Cooling system kw

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

WATER SOURCE HEAT PUMPS

N2AE - 50 Hz PRODUCT SPECIFICATIONS

Transcription:

ENR 002-480 Incorporating R410A Refrigerant Air cooled water chillers with scroll compressors and axial fans, 2.2-480kW ENR 002-100 models inc. self-cleaning coaxial evaporators ENR 130-480 models inc. shell and tube evaporators

The complete solution to all your cooling needs ENR 002-480 Index Page General Description... 3 Technical features...3 Technical Data ENR Range 002 030... 4 Technical Data ENR Range 038 100... 5 Technical Data ENR Range 130 480... 6 Optional Accessories... 7 1

2

The complete solution to all your cooling needs ENR 002-480 General Description ENR range consists of 28 models covering a cooling capacity from 2.2 to 480kW. Technical features Frame Self-supporting painted steel frame. Easy to remove panels allow access to the inside of the unit for maintenance and other necessary operations. Compressors Scroll hermetic type with oil sight glass. Includes an internal overheat protection and crankcase heater, installed on rubber shock absorbers. Evaporator Self-cleaning coaxial type (ENR 002-100) or dual circuit shell and tube (ENR 130-480). Condenser Made up of a copper tube and aluminium fins. Circuits on the refrigerant side are made to create one circuit in models ENR 002-100 and ENR 005-100 and two independent circuits in models ENR 130-480. Alternative materials are available. Fans Axial fans directly coupled to a three-phase electric motor with external rotor (ENR 002-004 are single phase). A safety fan guard is fitted on the air flow discharge. On the super silenced units the fans have a low rpm. Electrical Board Includes: main switch with door safety interlock, fuses, overload protection for compressors & thermocontacts for fans, interface relays and electrical terminals for external connections. The power supply for ENR 002-004 is 230V/1Ph/50Hz. For all other models, the supply is 400V/3Ph/50Hz. Refrigeration Circuit All models include filter dryer. Models ENR 002-004 are capillery, ENR 005+ have thermostatic valves. Models ENR 005+ also include sight glass and liquid line solenoid valve. Water Circuit: Includes end suction close coupled pump, water tank, flow switch (ENR 002-008 supplied loose), evaporator, temperature sensor, antifreeze probe, water pressure gauge and manual air breather valve. Microprocessor A microprocessor controls all the functions of the unit and allows any adjustments to be made. The set-points and operating parameters are set directly into the microprocessor. This type of microprocessor enables the adjustment of up to four compressors. It has a visual alarm signal, push buttons for the various functions, and offers a continuous control of the system as well as saving all the data in case of a cut in the power supply. Through the display, one can input and have an indication of set values. Principal functions Indication of entering and leaving water temperature; identification and display of blocks by means of alphanumerical code; control of one or two pumps; differential pressure switch alarm delay at start-up; prestarting of the fans; hour counter of compressors in operation; automatic changeover of compressor and pump sequence; compressors start individually and not together; frost protection; remote on-off; operation signalling; manual operation; manual reset; pump down stop. Alarms High and low pressure (from 022 model) and overload on each compressor; antifreeze; flow switch (from 022 model); configuration error. Accessories Electronic card for connection to management and service systems; remote display. Operating Range Cooling Min. Max. Inlet water temperature C 8 25 Outlet water temperature C 5 20 Water thermal difference C 3 9 Ambient air temperature C -20 46 Minimum chilled water outlet temperature with glycol mixture Max. operating pressure heat exchanger water side C -8 kpa 1000 3

Incorporating Technical Data ENR Range 002 030 Aircooled liquid chillers ENR series Scroll compressors R410A Coaxial evaporator Condenser with copper tubes, aluminium fin Axial fans Model 002 003 004 005 008 010 012 016 018 022 030 Nominal cooling capacity (1) kw 2.2 3.4 4.6 5.3 7.9 10.2 12.2 15.8 18 22.5 31.7 Nominal cooling capacity (1) Frig/h 1892 2924 3956 4558 6794 8772 10492 13588 15480 19350 27262 Total compressors nominal absorbed power (1) kw 0.8 1.3 1.7 1.7 2.6 3.4 3.9 5.2 5.8 6.7 8.9 COP W/W 2.7 2.6 2.7 3.12 3.04 3.00 3.13 3.04 3.10 3.36 3.56 EER W/W 2.4 2.5 2.6 2.9 2.8 2.8 2.7 2.7 2.8 3.0 3.07 ESEER 3.4 3.3 3.4 3.3 3.3 3.6 3.8 3.9 3.9 3.8 4.2 IPLV 3.9 3.8 3.9 4.1 4.1 4.1 4.3 4.3 4.3 4.5 4.9 Compressors no. 1 1 1 1 1 1 1 1 1 1 1 Circuits no. 1 1 1 1 1 1 1 1 1 1 1 Partion step no. 1 1 1 1 1 1 1 1 1 1 1 Hydraulic Section Nominal water flow m 3 /h 0.4 0.6 0.8 0.9 1.4 1.8 2.1 2.7 3.1 3.9 5.5 Evaporator pressure drop kpa 22 22 23 23 26 25 27 28 28 31 31 Available pressure mca 15 15 15 22 24 26 25 24 24 25 28 Pump absorbed power kw 0.15 0.15 0.15 0.37 0.88 0.98 0.98 0.98 0.98 1.28 1.28 Pump absorbed current A 1.9 1.9 1.9 3.2 1.7 1.8 1.8 1.8 1.8 2.4 2.4 Hydrulic connections BSP/ 1" 1 1/2 1/2 1/2 3/4" 1" 1" 1" 1" 1" DN 1/4 1/2" Tank volume dm 3 40 40 40 40 50 50 50 50 110 110 270 Fan Section Total air flow m 3 /h 1400 1300 1500 1500 4700 4700 5900 5700 5700 9100 15600 Fans nr. 1 1 1 1 1 1 1 1 1 1 2 Fans absorbed power kw 0.10 0.10 0.10 0.10 0.25 0.25 0.68 0.68 0.68 0.81 1.44 Fans absorbed current A 0.4 0.4 0.5 0.5 1.1 1.1 3.0 3.0 3.0 1.5 2.8 Total Electric Data Nominal absorbed power kw 1.2 1.6 2.1 2.2 3.7 4.6 5.6 6.9 7.5 8.8 11.6 Maximum absorbed current (F.L.A.) A 8.7 10 10.4 12.5 10.1 10.5 14 14.6 18.8 19.8 26.3 Maximum peak current (L.R.A.) A 31 36 35 46 48 48 71 71 75 104 144 Electric feed V/Ph/ Hz 230/1/50 400/3/50 Noise Data Sound pressure (2) db(a) 51.0 51.0 51.0 51.0 51.0 51.0 52.0 52.0 52.0 52.5 52.3 Dimensions and Weight Length mm 600 600 600 600 820 820 820 820 1008 1008 1610 Width mm 655 655 655 655 615 615 615 615 718 718 860 Height mm 1035 1035 1035 1035 1360 1360 1360 1360 1580 1580 1540 Weight empty kg 85 85 90 102 175 180 185 190 230 260 390 Weight operating kg 125 125 130 145 225 230 235 240 360 390 690 (1) Inlet/Outlet water temperature = +12/+7 C - Condenser air temperature = +35 C; fouling factor = 0.000043 m²k/w (2) Sound pressure level referred to measures according to normative ISO3744, pressure level at distance of 10 m, referred to free field on reflecting surface 4

The complete solution to all your cooling needs ENR 002-480 Technical Data ENR Range 038 100 Aircooled liquid chillers ENR series Scroll compressors R410A Coaxial evaporator Condenser with copper tubes, aluminium fin Axial fans Model 038 045 055 061 070 075 090 100 Nominal cooling capacity (1) kw 39 45 52 61 66 78 90 100 Nominal cooling capacity (1) Frig/h 33540 38700 44720 52460 56760 67080 77400 86000 Total compressors nominal absorbed power (1) kw 11.5 12.9 17.0 17.8 20.5 23.0 25.9 30.7 COP kw/kw 3.39 3.49 3.06 3.43 3.22 3.39 3.47 3.26 EER kw/kw 2.97 3.14 2.79 3.00 2.70 2.90 3.02 2.89 ESEER 4.4 4.4 4.3 4.2 4.3 4.3 4.2 4.3 IPLV 5.1 5.1 5.1 5.0 5.1 5.1 5.1 5.1 Compressors no. 1 1 1 2 2 2 2 2 Circuits no. 1 1 1 1 1 1 1 1 Partion step no. 1 1 1 1/1 1/1 1/1 1/1 1/1 Hydraulic Section Nominal water flow m 3 /h 6.7 7.3 8.9 10.5 11.3 13.4 15.5 16.5 Evaporator pressure drop kpa 32 32 33 34 33 32 38 39 Available pressure mca 31 30 33 32 31 29 28 27 Pump absorbed power kw 1.28 2.20 2.57 2.56 2.56 2.56 3.48 3.48 Pump absorbed current A 2.4 4.2 4.6 4.6 4.6 4.6 6.1 6.1 Hydrulic connections BSP/DN 1 1/2" 1 1/2" 1 1/2" 2" 2" 2" 2" 2" Tank volume dm 3 270 270 270 410 410 410 410 410 Fan Section (Axel) Total air flow m 3 /h 16800 14800 15600 24800 36000 36000 34000 34000 Fans nr. 2 2 2 2 2 2 2 2 Fans absorbed power kw 1.62 1.44 1.62 2.50 3.90 3.90 3.90 3.90 Fans absorbed current A 3.1 2.8 3.1 5.0 7.8 7.8 7.8 7.8 Total Electric Data Nominal absorbed power kw 14.4 16.5 21.2 22.9 27.0 29.5 33.3 38.1 Maximum absorbed current (F.L.A.) A 31.9 37.8 47.8 51.8 59.9 65.2 75.5 84.4 Maximum peak current (L.R.A.) A 160 201 220 173 192 197 242 259 Electric feed V/Ph/Hz 400/3/50 Noise Data Sound pressure (2) db(a) 53.0 54.8 55.5 55.1 56.2 57.1 57.9 59.5 Dimensions and Weight Length mm 1610 1610 1610 2220 2220 2220 2220 2220 Width mm 860 860 860 1100 1100 1100 1100 1100 Height mm 1540 1540 1540 2100 2100 2100 2100 2100 Weight empty kg 400 430 450 810 820 830 855 930 Weight operating kg 700 730 750 1240 1250 1260 1285 1360 (1) Inlet/Outlet water temperature = +12/+7 C - Condenser air temperature = +35 C; fouling factor = 0.000043 m²k/w (2) Sound pressure level referred to measures according to normative ISO3744, pressure level at distance of 10 m, referred to free field on reflecting surface 5

Incorporating Technical Data ENR Range 130 480 Aircooled liquid chillers ENR series Scroll compressors R410A Shell and tube evaporator Condenser with copper tubes, aluminium fin Axial fans Model 130 160 185 230 280 340 370 430 480 Nominal cooling capacity (1) kw 127 156 184 227 277 340 370 430 480 Nominal cooling capacity (1) Frig/h 109220 134160 158240 195220 238220 292400 318200 369800 412800 Total compressors nominal absorbed power (1) kw 35.7 46.0 51.8 70.1 77.6 96.0 106.9 127.8 149.5 COP kw/kw 3.56 3.39 3.55 3.24 3.57 3.54 3.46 3.36 3.21 EER kw/kw 3.21 3.01 3.19 2.84 3.17 3.22 3.12 3.08 2.98 ESEER 4.4 4.3 4.4 4.3 4.2 4.4 4.3 4.3 4.3 IPLV 5.2 5.2 5.1 5.1 5.0 5.0 5.1 5.1 5.0 Compressors no. 4 4 4 4 4 4 6 6 6 Circuits no. 2 2 2 2 2 2 2 2 2 Partion step no. 2/2 2/2 2/2 2/2 2/2 2/2 3/2 3/2 3/2 Hydraulic Section Nominal water flow m 3 /h 21.8 26.8 31.6 39.0 47.7 58.5 63.6 72.4 82.6 Evaporator pressure drop kpa 39 39 38 36 40 40 43 43 49 Available pressure mca 28 27 30 30 28 28 28 28 27 Pump absorbed power kw 4.57 4.57 6.26 6.26 8.61 8.61 10.17 10.17 12.22 Pump absorbed current A 7.8 7.8 10.4 10.4 14.3 14.3 16.7 16.7 20.3 Hydraulic connections BSP/DN DN65 DN65 DN65 DN125 DN125 DN150 DN150 DN150 DN200 Tank volume dm 3 390 390 390 500 500 500 500 500 500 Fan Section (Axial) Total air flow m 3 /h 38000 58000 54000 90000 87500 85000 108000 105000 102000 Fans nr. 2 3 3 5 5 5 6 6 6 Fans absorbed power kw 3.88 5.82 5.82 9.70 9.70 9.70 11.64 11.64 11.64 Fans absorbed current A 7.8 11.7 11.7 19.5 19.5 19.5 23.4 23.4 23.4 Total Electric Data Nominal absorbed power kw 44.2 56.4 63.9 86.1 95.9 114.3 128.7 149.6 173.4 Maximum absorbed current (F.L.A.) A 100.0 125.1 145.3 190.3 232.2 279.8 299.3 337.7 388.9 Maximum peak current (L.R.A.) A 221 257 312 365 443 538 439 548 599 Electric feed V/Ph/Hz 400/3/50 Noise Data Sound pressure (2) db(a) 56.4 59.3 59.7 62.2 62.6 64.9 65.5 66.5 67.1 Dimensions And Weight Length mm 3350 3350 3350 5350 5350 5350 6350 6350 6350 Width mm 1100 1100 1100 1100 1100 1100 1100 1100 1100 Height mm 2180 2180 2180 2180 2180 2180 2180 2180 2180 Weight empty kg 1265 1440 1595 1915 2115 2160 2390 2560 2720 Weight operating kg 1950 2155 2350 2695 3025 3080 3310 3480 3640 (1) Inlet/Outlet water temperature = +12/+7 C - Condenser air temperature = +35 C; fouling factor = 0.000043 m²k/w (2) Sound pressure level referred to measures according to normative ISO3744, pressure level at distance of 10 m, referred to free field on reflecting surface 6

The complete solution to all your cooling needs ENR 002-480 Optional Accessories Mechanical Configuration Options LN Low noise (compressors jacket, fan speed regulator) Model 008 onwards CF Condenser aluminium filter Model 002 onwards CV Epoxy coated aluminium fin coils Model 002 onwards CC Copper/copper condenser Model 002 onwards CG Fin guard silver treatment on condenser Model 002 onwards GALV1 Galvanised main frame Model 002-022, included on 030+ GALV2 Galvanised panels (in conjunction with main frame) Model 002-022, included on 030+ ATS Spring type anti-vibration mounting Model 002 onwards Hydraulic Circuit Configuration Options BPA Automatic bypass Model 002 onwards SS.T.WP Stainless steel hydraulic circuit with plate exchanger, pump & tank Model 002 onwards NT.NP No tank, no pump, carbon steel with shell & tube evaporator Model 002 onwards NT No tank, with shell & tube evaporator and pump Model 002 onwards DP Double pump Model 018 onwards PH 5 bar pump Model 002 onwards DPH Double pump with 50 mca with contacts and overload Model 018 onwards AT Management pumps (in conjunction with DP or DPH) Model 022 onwards VTP Manual valve between tank & pump (in conjunction with standard version/dp/ph or DPH) Model 002 onwards RAGT Antifreeze heater internal in tank Model 002 onwards RAGP Antifreeze heater pump Model 002 onwards LLA Electric float low level alarm Model 002 onwards Refrigerant Circuit Configuration Options CSV Compressor suction valve Model 008 onwards HP High pressure gauges Models 002-045, included on models 061+ LP Low pressure gauges Models 030 onwards PDS De-superheater with plate exchanger Model 030 onwards PMC Precision leaving temperature (+/-1ºC) Model 002 onwards LW Low water temperature (outlet until -15ºC) Model 002 onwards LT Low ambient temperature (until -25ºC) Model 002 onwards Electric Circuit Configuration Options RV Fan speed regulator Model 002 onwards RVG General voltage relay Model 008 onwards CSF 3 phases sequences relay Model 008 onwards OFC On-off compressors signal Model 012 onwards SF Soft start Model 012 onwards Remote Connection Arrangement Options RS485 Serial card for carel/modbus (RS485) Model 002 onwards OFR Remote display (on/off) Model 002 onwards OFRC Remote control with on/off remote + alarm management Model 030 onwards Packing Options WCA Wooden cage packing ISPM15 Model 002 onwards ANS Rubber pad anti-vibrating (shipment) Model 002 onwards PLT Pallet/ISPM15 pallet Models 002-022 7

8 Incorporating

The complete solution to all your cooling needs ENR 002-480 9

Due to continual product development, details contained within this brochure may change without notice and are therefore purely indicative. T: 0845 0941 800 F: 0845 0941 900 www.aquacooling.co.uk Aqua Cooling Solutions Ltd Unit D4 Segensworth Business Centre Segensworth Road Fareham Hampshire PO15 5RQ