INSTALLATION AND OPERATION INSTRUCTION

Similar documents
GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

VRW2 Dynamic Pressure- Regulating Flanged Control Valves

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

FlowCon SM mm. Dynamic Self Balancing Control Valve SPECIFICATIONS

FlowCon Energy FIT System

Fig.306F (DN50-150) Pressure Independent Control Valve (PICV)

Flight Systems. Replacement for KASSEC DESCRIPTION

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Tracer VMA with AutoReg

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve

Installation and User Manual. with RAIN SENSOR.

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

SMT-150 Installer Manual

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Mounting UNV Kits to NV Type Actuators

Globe Valve Retrofits

IWT 565 Series Valve Operation Manual

Harmony Installation, Operation and Maintenance

RUS-L24-MOD Electric 24 Volt Modulating Control Damper & Louver Actuator

710-xxxp Propagation & Irrigation Battery Operated Controller

Water Specialist EE Control Valve Programming and Cover Drawing Manual

PowerView PV380-R2 Mechanical Configuration

Rally computer 3 Rally computer 3.GPS *

RUS-L24-MOD Electric 24 Volt Modulating Control Damper Actuator

Water Specialist igen Control Valve Programming and Cover Drawing Manual

STREAMLINER M 500 cc Instructions. User Operating Manual

i n s t r u c t i o n m a n u a l

SAVANNAH EI & DELUXE SYSTEM TROUBLE SHOOTING GUIDE

PLC Controlled High Performance Automatic Grease Lubricator

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

SPREADER SYSTEM. Proportional three function. 1. Features and Specifications. User Manual 12 INPUTS 12 OUTPUTS CONNECTIVITY MAIN FEATURES

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

i n s t r u c t i o n m a n u a l

BNT 85 /185 Valve Operation Manual

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Water Specialist EI Control Valve Programming and Cover Drawing Manual

Tracer VM with User Interface

Owner s Manual. MG2000 Speedometer IS0211. for use with SmartCraft Tachometer

LIPPERTCOMPONENTS, INC.

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

PTJ/PTJM Intelligent Electric Actuator Installation and Operation Instructions

ECLIPSE Laundry Dispenser Controller

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Technician Manual. Electronic Table -Top Autoclaves Models EZ9Plus & EZ11Plus

Documentation. RM-BV4 Micro DP. Filter control

Section 55 Chapter 6

i n s t r u c t i o n m a n u a l

i n s t r u c t i o n m a n u a l

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

Signet Temperature Transmitter

Water Specialist PR Control Valve Programming and Cover Drawing Manual

ECscan20 Pocket Conductivity Tester Instruction Manual

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

i n s t r u c t i o n m a n u a l

TC62D Installation Instructions

CruzPro. RPM, Engine Hours, Elapsed Time Gauge RH110. Other CruzPro Products

SE8300 Series Installation Guide 24 Vac Low Voltage

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual

SIGNET Temperature Transmitter

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Signet Pressure Transmitter

Application Note TADII - Threshold Angle Detector Operation and Calibration Instructions

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

TECHNICAL MANUAL FOR ELECTRONIC SPEEDOMETER STR-RIEJU MATRIX 2

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

Operating instructions Flow monitors SI / / 2010

PCT-3001 plus. Display LCD

Installation and Maintenance Manual IM

If your vehicle is not equipped with the DIC steering wheel buttons not all of the features listed will be available on your vehicle.

CA 180 Owner's Manual

Variable Speed Pump and Drive Technical Guide

Owner s Guide CA2LCD5

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

fusion RF Control Handle

SAX Electronic Valve Actuator

B-RAD Select USER MANUAL TABLE OF CONTENTS

ECL Apex 10. User Guide. ECL Apex 10 *087R9745* Installation and configuration. *vijem102*

Model FMBC3000 Series Operating Instructions. Drum Pump Flow Meter

MATRIX LLC LEVEL CONTROL PANEL

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

ECONOMISER SERIES E2T USER MANUAL

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

Pressure Independent Control Series

S1024-2POS / S POS S2024-2POS / S POS

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

Signet Pressure Transmitter

L5000Plus. Programming Guide

KVC7934, KVC7936. Modulating Actuators without and with Power Failure Reposition For KVC Series Cartridge Valve. Specifications 12.

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Transcription:

INSTALLATION AND OPERATION INSTRUCTION ATi Max 2-1/2-6, 65-150mm Install the ATi Max valve either in the supply or return pipework for the unit. It is recommended that a strainer be installed prior to the valve body to prevent damage or blockage due to debris. INSTALL THE VALVE HOUSING WITH THE FLOW DIRECTIONAL ARROW POINTING IN THE CORRECT DIREC- TION. IMPORTANT: Valve diameter should NEVER exceed pipe diameter! The valve body is available for double flange connections, i.e figure 1. O-rings are supplied with the valve body and are used to seal the connections. Please make sure these are in place in the o-ring grooves in the inlet and outlet of the valve body, when installing the housing. It is recommended to grease the o-rings with a silicone grease before installation. IMPORTANT: Never use mineral oil or petrol based grease or oil on the o-rings. Valve bodies are as standard supplied with pressure/temperature fittings (p/t plugs). Before finger mounting the p/t plugs in the body tappings, please seal the threads of the p/t plugs (DO NOT OVER TIGHTEN). Figure 1 8-19-2013 1

Fitting and orientation of the actuator. The bottom side of the actuator To fit the actuator on the valve body, please grease the o-ring on the spindle adaptor and place the spindle adaptor on the valve spindle. Place the actuator on the spindle adaptor and place the three actuator legs into the three holes in the mounting bracket. Make sure that the snap ring is clicked onto the mounting bracket, so that the snap ring is locked at the top of the mounting bracket, but is able to rotate. Then turn the snap ring counter clockwise (upside view) approximately 1/6 of a turn until its stop points touch the actuator legs and the mounting is locked with a (small) click (please see figure 2 and 3). To remove the actuator, please reverse the procedure, i.e. turn the snap ring clockwise until the actuator is loosened and lift the actuator up (fig. 4). To ease removal of actuator, make sure that the valve is not fully closed. Symbols at the bottom side of the actuator also indicate how to lock and unlock the actuator with the snap ring. Figure 2 Actuator legs Snap ring: Figure 3 Stop points Figure 4 360º Figure 5 2

Wiring instructions. Analog Black Blue White Green Common Control Signal Feedback Digital - 2 position Supply Black Blue White Red Green Common Open if NC, Close if NO Close if NC, Open if NO Feedback Digital - 3 point floating Supply Black Blue White Red Green Common Open if NC, Close if NO Close if NC, Open if NO Feedback If feedback signal is not required, leave green wire detached. Start-Up sequence. When power to the actuator is turned on, the actuator will automatically calibrate: Valve is calibrating to determine closing point. This calibration can take up to 10 minutes depending on the valve s position at start-up. During calibration lower part of display will show CAL. When control signal is present, actuator will adjust to current control signal and proceed with normal operation. At first start-up please enter programming menu to adjust actuator settings. If no control signal is detected, flush is started if enabled in programming menu (enabled by default), opening valve to 5/6 of fully open. Lower part of display will show FLUSH until control signal is detected. 3

Programming Menu. The programming menu is always accesible. To enter the programming menu, please simultaneously press and for 6 seconds, until bottom line blinks. All values selected in the programming menu are stored in non-volatile memory. Step Display Description Values Generally, press to accept value and go to next step and press button to go to previous step. To change the value, please press or keys, for quick scroll through values hold down the button. Press and simultaneously for 6 sec. to exit programming menu. Actuator will automatically return to operation mode if no action is detected on arrow keys during 1 minute. 0 Password. scrolling top: ENTER PASS WORD 1 Select language. scrolling top: SELECT LANGUAG Disabled by default Password: 3569266. Only if Enabled (in step 11). Change one digit at a time, press and to move between digits. At last digit, press to go to next step. Default: English. Possibility to choose other languages later on (not currently an option). 2 Select valve model onto which the actuator is installed. ATIMX-S-113 ATIMX-S-157 ATIMX-M-149 = = = SM.3.1 SM.3.2 SM.4.1 scrolling top: SELECT VALVE MODEL ATIMX-M-225 ATIMX-M-320 ATIMX-L-369 Default: SM.0.0 Select from the 7 available valve models. (See cross Reference Below) Options: SM.1.1, SM.2.1... = SM.4.2 ATIMX-L-468 = SM.5.2 = SM.4.3 = SM.5.1 3 Choose unit scale for rate. scrolling top: SELECT UNIT SCALE 4 Activate Flush mode at start-up. scrolling top: SELECT FLUSH MODE 5 Select type of control signal. scrolling top: SELECT CONTROL SIGNAL 4 Default: l/sec. Options: l/sec or l/hr or GPM. Default: Enable. Options: Enable or Disable. When no control signal (analog) is detected opened). It will be dismissed when control signal is detected. Default: 2-10VDC. Options: 2-10VDC or 4-20mA or digital. Choose: 2-10VDC for VDC 4-20mA for ma Digital for 2 position or 3 point

Step Display Description Values 6 Select minimum control value. scrolling top: SET MINIMUM LIMIT 7 Select maximum control value. scrolling top: SET MAXIMUM LIMIT 8 Select feedback signal. scrolling top: SELECT FEEDBAC SIGNAL 9 Set the designed maximum Accuracy: Greatest of either ±5% of designed max. ±2% of scrolling top: SELECT MAXIMUM FLOW 10 Select direction of rotation. scrolling top: SELECT ROTAT DIRECT 11 Activation of password. scrolling top: ACTIVAT PASS WORD Volt default: 2. Options: from 0-7. Increment: 0.1. ma default: 4. Options: from 0-14. Increment: 0.2. NA if Digital (in step 5). Volt default: 10. Options: from 3-10 and at least 3 VDC greater than the selected minimum limit. Increment: 0.1. ma default: 20. Options: from 6-20 and at least 6 ma greater than the selected minimum limit. Increment: 0.2. NA if Digital (in step 5). Default: AU; Automatic match of control signal if analog. Options: 0-10 VDC, 2-10 VDC or 4-20 ma or AU. If Digital (in step 5) AU is not an option. Default: Maximum setting. Values depend on valve model and unit scale chosen in step 2 and 3. Stepping increments as per tech note. Default: Normally Closed (NC). Options: Normally Open (NO) or Normally Closed (NC). Default: Disable. Options: Enable or Disable. If Enabled password is required to access alarm and programming menu. 12 Select direction of rotation when Failsafe. scrolling top: SELECT FAIL SAFE DIRECT Default: Closed. Options: Open or Closed. Only valid for BMTFS (failsafe model). Failsafe direction open means Failsafe mode (only BMTFS). If power supply is out of range or lost, failsafe mode will be activated: 1. Approx. 80 sec. delay. 2. Actuator opens/closes valve (according to failsafe direction chosen in programming menu). 3. Actuator shuts off. If power supply is restored during action 1. or 2., failsafe mode is deactivated. 5

In Operation. Display Description Values Indicates unit scale system. l/sec or l/min or GPM. ma or VDC. Indicates battery level. Basic version with no battery (BMT) Failsafe version with battery (BMTFS) Battery level low, charging needed. Medium battery level. Battery charged. Alarm indicator. Blinking if actuator is still functional (warning). Fully on if actuator is not working (critical). Information Current rate 1. Indicates current rate in l/sec, l/hr or GPM. CONTROL SIGNAL 2.0 VDC FEEDBAC SIGNAL 2.0 VDC VALVE SM. 3.1 pressur range 35-400 kpad MAXIMUM FLOW RATE 6.580 L/SEC OPERAT DIRECT NC FAIL SAFE DIRECT CLOSE ERROR CODE 01 Information Control signal Indicates value of control signal. 0-10 VDC or 0-20 ma or Open/Stop/Close Feedback signal Indicates value of feedback signal. 0-10 VDC or 0-20 ma. Valve Indicates valve model. SM.1.1, SM.2.1... Pressure range Indicates pressure range. 32-320 kpad, 40-320 kpad... Maximum rate Indicates selected maximum designed rate. Operational direction Indicates direction of rotation. NO or NC. Depends on valve etc. l/sec, l/hr or GPM. Failsafe direction Indicates failsafe direction. Open or Closed Only valid for SM.0.0.0.4 Critical Alarm Indicates alarm error code. 01, 03, 05 (without failsafe) or 06. Only if critical alarm is present. Note 1: Note that the rate displayed on the actuator is a calculated value based upon differential pressure being within control range. If display shows NA instead of current rate, it indicates that the rate is below minimum rate according to tech note, or that valve model has not been chosen in programming menu step 2. Use to go to next information line and to go to the previous. 6

Alarm Menu. To enter the alarm menu, please simultaneously press and for 6 seconds. You can access the alarm menu only if an alarm is present (i.e when icon is displayed). Press to go to the next alarm display, press to return to previous step. Press and simultaneously for 6 seconds to exit alarm menu. Actuator will automatically return to operation mode if no action is detected on arrow keys during 1 minute. Display Description Action Alarm. Enter password. If enabled in programming menu step 11 Disabled by default. Password: 3569266. Code Icon Description Details 01 Valve/actuator is overtorqued. Operation is stopped. Actuator will retry operation every 4 minutes. If over torque condition FULL ON disappear, error will convert to error code 02. 02 Actuator has reached its torque BLINKING limit in the past. Actuator is functioning. To reset the alarm simultaneously press and for 6 seconds. 03 Critical - over temperature. Critical: Temperature in actuator is at least FULL ON 158ºF, motor operation is stopped. If temperature is decreasing, operation will resume. 04 High temperature. Actuator is still functioning. Temperature in BLINKING actuator is at least 122ºF as limited according to tech note. If temperature is decreasing, operation will resume. 05 No Failsafe: Power supply not Operation is stopped. Alarm will automatically FULL ON in range. reset when voltage is back in range. BLINKING With Failsafe: Power supply not detected / not in range. Failsafe is activated. Alarm will automatically reset when voltage is back in range. 06 Control signal not detected. Operation is stopped. Alarm will automatically FULL ON reset when control signal is back in range. 07 Battery error. Battery is not properly connected. Alarm will BLINKING reset when battery is properly connected. Only valid for BMTFS. In case of ERRORS or ALARM If actuator is still functioning (error 02, 04, 05 with failsafe and 07 with failsafe) the ALARM icon flash. Error codes can be found in the alarm menu. will If actuator is not functioning (error 01, 03, 05 without failsafe and 06) the ALARM icon is turned on. The error code will be available in the information in the upper part of the display and the alarm menu. 7

Auto-stroke - re-calibration. In case the valve does not operate as expected, start the auto-stroke sequence to re-calibrate the closing point of the valve and to make sure that the actuator is able to open the valve fully. Press buttons and simultaneously for 6 seconds to start the auto-stroke. Auto-stroke sequence. (display shows: AUTO STROKE CYCLES ): 1. Valve is closed to determine closing point. 2. Valve is opened fully (independent of max. flow chosen). 3. System returns to normal operation. If actuator is not able to open valve fully, an error will be displayed. An auto-stroke cannot be cancelled. Manual override. Manual override is used to temporarily set the position of the valve regardless of the settings and control signal for the actuator. 1. Turn off power to the actuator. 2. Remove actuator from valve as described. 3. Turn spindle to the relevant position (Clock-wise to close valve, counter clockwise to open valve). Be sure not to use more than 10 Nm torque. Please protect actuator from water while not on valve. 4. Re-mount actuator on valve as described. 5. Turn on power to the actuator when normal operation is needed. General. Water must always be suitable treated, clean and free of debris. It is recommended that a strainer be installed prior to the valve body to prevent damage or blockage due to debris. Ensure that the valve is not in the fully closed position when filling the system with water. Further, it is recommended not to exceed maximum differential pressure control range. Warranty obligation. Failure to abide by all recommendations as per this installation and operation instruction will void warranty. Do not remove cover from actuator. Opening cover will void warranty. When manually operating the valve (actuator disconnected) do not use more than 10 Nm torgue. Using more than 10 Nm torgue will void warranty. 8