Solenoid interlock AZM 200 The non-contact interlock.

Similar documents
Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Safety Sensor CSS 180 Product Information

Safety door-handle system STS

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

AZM300 More than just a solenoid interlock

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

AZM 161SK 12/12RKED/TU 024

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock AZM About this document. Content

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

More than just a solenoid interlock AZM300

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Guard locking systems for the protection of man and machine

Operating instructions Solenoid interlock AZM About this document. Content

Operating instructions Solenoid interlock AZM About this document. Content

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Operating instructions Solenoid interlock AZM 170

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Safety switches with solenoid and separate actuator

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

SG-B1 SERIES / SG-A1 SERIES

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

Door locking devices. 4 Schmersal Industrial Switchgear

Technical data. Standards: IEC/EN BG-GS-ET-15

Application Mini Contactors for Motors and Resistive Loads

Workshop Solenoid Interlocks

Safety switches with solenoid and separate actuator

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Under the aspect of simplified

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

F3S-TGR-KHL1/-KHL3/-KHL3R

Single foot switches - PX and PA series

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Motor Starter Reverse MSR22-FBP

FUNCTIONAL SAFETY SOLUTIONS in Solenoid Valves

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Safety rope switches with reset for emergency stop

Sense7-series Non-contact coded safety switch

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

1.1. Safety Products. Contents. LS-Titan Safety Interlock Switches. LS-Titan Safety Interlock Switches

Safety Control HR1S-AC. Safety Relay HR1S-AC

Datasheet - MV8H Y

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

Transponder-coded. with guard locking

SFS-UFS Single Foot Switches

SOLENOID VALVES AND PNEUMATIC VALVES

Safety switches / Position switches / Command devices

Safety switches with separate actuator

IDEM MPC Non-Contact Coded Magnetic Safety Switches MPC Series Plastic Housing

Transponder-coded. with guard locking

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Safety switches for hinges

Electronic circuit breaker EBU10-T

Switches with manual reset

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

FL series position switches

Application Mini Contactors for Motors and Resistive Loads

LR-LX-LK-LW Safety Switches with separate actuator

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

LK Position Switches TECHNICAL DATASHEET.

DX³ RCCBs - ID 4P up to 100 A

CAUTION CM-SE CM-S21 CM-S41

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Contactors. C110B/80, C110B/120 C110B/200, C110B/300 Single pole DC NO contactors for industrial trucks Catalogue B71.en

ZB0050 / ZB0051 ZB0070 / ZB0071

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

TX³ RCCBs 2P up to 100 A

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

FOOT SWITCHES

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Contactelement,1N/C,frontmount,6.contact,screwconnection. Product range RMQ-Titan (drilling dimensions 22.5 mm)

Single foot switches PX and PA series

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Transcription:

Solenoid interlock AZM 200 The non-contact interlock.

Solenoid interlock AZM 200 The non-contact Solenoid interlocks demand accurate alignment of actuator and device. This requirement is met on new machinery. But during its lifetime, the situation may occur in which the actuator can no longer easily enter the device. As a consequence, both parts become damaged. This in turn leads to machine downtime and repair costs. Schmersal eliminates this problem with the new, patented AZM 200 solenoid interlock. Due to newly developed sensor technology from Schmersal, the actuator and interlock can now have an offset of ± 5 mm and the actuator still engages the interlock. This simplifies the mounting and reduces regular maintenance and adjustment of the safety guard. As an additional installation feature, the AZM 200 has two slotted mounting holes, enabling a quick and smooth mounting on aluminium profiles or steel frames using just two screws. The slim, symmetrical design is ideally suited for installation on current aluminium profiles with a minimum width of 40 mm. With its modern and ergonomic design, the AZM 200 is the right choice of solenoid interlock for all machinery with a high demand on visual appearance. Three LED's indicate the operating state. Therefore, the operator always knows whether the door is released for unlatching. This interlock offers enormous advantages particularly for fences around hazardous areas with walk-in access. Due to the one-hand operation of the emergency handle, the hazardous area can be left quickly and safely, even during a power failure a feature, which is unique on the market. The AZM 200 increases machine availability through the integrated modern electronics. This is because intelligent diagnosis provides fast trouble-shooting. A fault does not lead to an immediate machine switch-off; the fault is first signalled so that the machine can be progressively shut down in a controlled manner. The AZM 200 can even be wired in series with other AZM 200 solenoid interlocks and also with the Schmersal safety sensor CSS 180. This feature considerably reduces the wiring costs and simplifies the set-up of safety circuits. 2

interlock ± 5 mm The solenoid interlock enables safeguarding of the guard door up to control category 4 to EN 954-1 using just one interlock, even when multiple interlocks are wired in series. An additional switch on the guard door is no longer necessary. Consequently, along with the reduced wiring costs, the number of control modules needed is also reduced. The AZM 200 not only complies with the requirements of EN 954-1, it was also developed and certified to IEC 61508, which makes it suitable for applications up to SIL 3. A SIL 3 certification requires the use of high reliable components inside the device as well as a high resistance to electromagnetic interferences, which is an important quality feature. The AZM 200 increases machine availability and is an extremely reliable highefficient device. Furthermore, the entire system of interlock and actuating unit saves additional door handles and hardware. The actuator is always inserted into its housing via the ergonomically shaped door handle. This protects the actuator and the operator against damages and injury. This design also impedes tampering with the interlock. Emergency exit with panic handle Actuating unit with door handle AZM 200 interlock 3

The essential advantages Patented system Sensor technology permits an offset of ± 5 mm between actuator and interlock Control category 4 to EN 954-1 with door detection sensor (without additional second switch) Suitable for SIL 3 applications to IEC 61508 Modern electronics facilitates intelligent diagnosis and increases the availability of machinery, because faults do not lead to the immediate machine switch-off Modern and ergonomic design for machinery which places high demands on visual appearance Easy mounting with just two screws Fine adjustment through mounting slots in the device and the actuator Slim, symmetrical device, perfectly suited for aluminium profiles with a minimum width of 40 mm LED indication of the operational state simplifies operation Emergency release with one hand possible, even in de-energised condition Smooth and intuitive operation No risk of injury from protruding actuator Saves additional door handles Does not protrude into the door opening Manual release from both sides Manual release Actuator sensors Actuator sensors Door detection sensors (optional) Door detection sensors (optional) 4

Mounting and application The AZM 200 was especially developed for applications at hinged guards and fences. The two slotted holes enable a fast and smooth installation on aluminium profiles or steel frames. In this way, the interlock can be perfectly adjusted and aligned with the doorpost, even afterwards, and does not protrude into the door opening. The actuator unit is also fixed with two screws. The link blocks allow for an accurate horizontal and vertical adjustment, both of the actuator unit and the optional emergency exit. This installation method does not require any additional mounting plates for the interlock and the actuating unit. Only the supplied square bar must be cut to the right length. Once the individual components (interlock, actuator unit and optionally the emergency exit) are fitted, the mounting screws are invisible, thus offering a high protection against tampering. The system is fit for any fence with a door gap restricted to 6,5 ± 1,5 mm and a door opening of at least 400 mm. Door hinge on left-hand side 57 51 33 6,5 ± 1,5 6 5 7 A 7 6,5 ± 1,5 5 51 57 33 6 Door hinge on right-hand side 155 155 115 88 78 88 78 115 6,5 6,5 6,5 32,5 32,5 6,5 115 220 220 115 40 B 40 Legend A = Front and rear manual release B = Cable entry M20 x 1,5 C = Emergency exit P1 D = Door handle G1 120 81,5 50 36,5 C D 16 max. 170 max. 170 16 C D 50 36,5 120 81,5 57,5 57,5 5

Diagnosis The integrated electronics of the AZM 200 allow for an extensive diagnosis of the different operational states of the device, thus facilitating the integration in the machine control as well as fast fault detection and trouble-shooting. This feature increases the runtime of the machinery. The AZM 200 has three LED s indicating its current state. Furthermore, the combination of the safety outputs and the diagnostic output informs the machine control about the operational state of the AZM 200. Meaning of the three LED s: Green = Supply voltage 24 VDC available Yellow = blinking: door closed, unlocked = continuous: door locked Red = blinking: error code (see below) = continuous: internal error The diagnostic output "OUT" has two states: 0 V, when the actuator is not inserted in the interlock and 24 VDC, when the actuator has been detected (i.e. engaged). When the interlock has locked the door, both the safety outputs Y1 and Y2 and the diagnostic output OUT supply 24 VDC. In case of a system error, which does not completely deactivate the safety function of the device (e.g. cross-wire) and therefore may only be tolerated for a certain time according to IEC 61508, the safety outputs are not immediately switched off. They keep supplying 24 VDC; the diagnostic output however immediately drops to 0 V. From this combination of safety outputs and diagnostic output, the machine control can immediately detect the error and progressively shut down the machine in a controlled manner, before the outputs of the AZM 200 drop to 0 V, thus triggering an immediately standstill of the machine. In case of such an error, the safety outputs are switched off after 30 minutes. 6

Diagnosis The blinking sequence of the red LED of the AZM 200 identifies the active error. The following errors are indicated: Indication (red) Meaning 1 blinking impulse Error output Y1 2 blinking impulses Error output Y2 3 blinking impulses Cross-wire 4 blinking impulses Temperature too high 5 blinking impulses Target error 6 blinking impulses Error target combination 7 blinking impulses Error AD values 8 blinking impulses Error transmission voltage 9 blinking impulses Channel error Continuous red Error The diagnostics function of the AZM 200 solenoid interlock The solenoid interlock signals the operational state and possible errors through thee coloured LED s, which are installed to the front of the device. The diagnostic output "OUT" is signalling errors before the safety outputs are switched off, thus enabling a controlled shut-down of the machine. LED State AZM 200 Diagnostic output Safety outputs green Supply voltage 0 V or 24 V 0 V or 24 V yellow Actuator inserted and locked 24 V 24 V (if X1=X2 = 24 V) blinking yellow Actuator inserted and not locked 24 V 0 V blinking red (1-9 impulses) Error: see blinking codes 10 s delayed: 0 V see table below continuous red internal error 0 V 0 V Blinking codes Meaning Autonomous Cause (red) switch-off after 1 blinking impulse Error output Y1 30 min Error in output test or voltage at output "Y1", although the output is switched off 2 blinking impulses Error output Y2 30 min Error in output test or voltage at output "Y2", although the output is switched off 3 blinking impulses Cross-wire 30 min Cross-wire between the output cables or error at both outputs 4 blinking impulses Temperature too high 30 min Temperature measurement indicates too high an inner temperature 5 blinking impulses Target error 0 min The difference between the code (frequency) of the detected target and the set value is too large, false target 6 blinking impulses Error target combination 0 min An invalid combination of targets was detected at the 4 coils of the AZM. (Current setting: latching bolt detected & door target not detected => latch breakage or tampering attempt) 7 blinking impulses Error AD values 30 min Internal hardware error 8 blinking impulses Error transmission voltage 0 min Supply voltage too low or defective internal voltage control 9 blinking impulses Channel error 30 min Data comparison between the channels leads to differences in the signal evaluation because of an internal hardware error 7

Electrical wiring I The AZM 200 is simply integrated in the safety circuit using the terminal block in the wiring compartment. I The safety outputs Y1 and Y2 consists of p-type shortcircuit proof transistors. Both outputs must be connected to the inputs of the safety control module used. In case of series wiring of multiple AZM 200 s, the outputs are connected to the safety inputs X1 and X2 of the next device. The magnet is energised through the "IN" terminal, i.e. when the terminal is connected to 24 VDC, the interlock is either locked (Power- To-Lock) or unlocked (Spring-To-Lock). The diagnostic output "OUT" signals the presence of the correct actuator in the interlock. If 24 VDC is supplied, the door is closed, but not necessarily locked. When no voltage is supplied, the actuator is not engaged in the interlock. In case of single device wiring, the bridge between the "24 V" terminal and the "X1" and "X2" terminals must be established; for series wiring, this bridge must only be established in the first device of the series. +24VDC 24V 24V X1 X2 IN AZM 200 Y1 Y2 OUT II 1 Q1 II SPS Q2 II 3 I2 Q3 0V Reset +24VDC K B K A A1 S12 S22 X1 X2 13 23 33 41 SRB 301 LC/B 0V A2 14 24 34 42 K A K B N Wiring example: Single device wiring 8

I I Wiring compartment AZM 200 24V 24V X1 X2 IN AZM 200 Y1 Y2 OUT Meaning Supply Voltage Supply Voltage Safety Input 1 Safety Input 2 Magnet Actuation Ground Ground Safety Output 1 Safety Output 2 Diagnostic Output Terminal 24 V 24 V X1 X2 IN Y1 Y2 OUT +24VDC 24V 24V X1 X2 IN AZM 200 Y1 Y2 OUT 24V 24V X1 X2 IN AZM 200 Y1 Y2 OUT 24V 24V X1 X2 IN AZM 200 Y1 Y2 OUT 0V II 1 Q1 II SPS Q2 II 3 I2 Q3 +24VDC K B K A Reset A1 S12 S22 X1 X2 13 23 33 41 SRB 301 LC/B 0V A2 14 24 34 42 K A K B N Wiring example: Series wiring of 3 AZM 200 9

Solenoid interlock AZM 200 The non-contact interlock Interlock 220 7 155 32,5 6,5 ± 1,5 5 6,5 40 51 57 6 6,5 115 33 88 78 115 Sensor technology permits an offset of ±5 mm between actuator and interlock Control category 4 to EN 954-1 with door detection sensor (without additional second switch) Suitable for SIL 3 applications to IEC 61508 Intelligent diagnosis Modern and ergonomic design Easy fitting Accurate adjustment through slotted holes LED indication of operating states (3 LED s) One-hand emergency release, even in de-energised condition Easy and intuitive operation No risk of injury from a protruding actuator Saves additional door handles Does not protrude into the door opening Emergency exit from both sides Approvals H under preparation Ordering data AZM 200➀-➁-1P2P➂ Nr. Insert Description ➀ SK Screw terminals CC Cage clamps ST Connector (M23) ➁ Without door detection sensors T With door detection sensors ➂ Power to unlock a Power to lock Actuator unit max. 170 16 57,5 50 36,5 120 81,5 The interlock and the actuator unit must be ordered separately. Below, the ordering codes for both units are indicated. Approvals H under preparation Ordering data AZ/AZM 200-B30-➀➁A➂➃ Nr. Insert Description ➀ L Door hinge on left-hand side R on right-hand side (view point towards the hazardous area) ➁ without T with door detection sensor ➂ G1 Door handle G2 Rotary button ➃ without emergency exit P1 with emergency exit Technical data Standards: IEC/EN 60947-5-1, EN 954-1, IEC/EN 61508 Enclosure: glass-fibre reinforced thermoplastic, auto-extinguishing Mechanical life: > 1 million operations F max : 2000 N Latching force: 30 N Protection class: IP 67 Insulation protection class: II, X Over-voltage category: III Degree of pollution: 3 Termination: screw terminals or cage clamps Cable section: min. 0,25 mm 2, max. 1,5 mm 2 (incl. conductor ferrules) Cable entry: M 20 x 1.5 Series wiring: max. 16 devices Cable length: max. 200m (Cable length and cable section alter the voltage drop depending on the output current) Ambient conditions: Ambient temperature: 25 C + 60 C Storage and transport temperature: 25 C + 85 C Resistance to vibration: 10 55 Hz, amplitude 1mm Resistance to shock: 30 g / 11 ms Switching frequency: 1 Hz Response time: < 30 ms Duration of risk: < 30 ms Time to readiness: < 2 s Electrical data: Rated operating voltage U e : 24 VDC -15% / +10% Rated operating current I e : 1 A No-load current I 0 : max. 0,5 A Rated impulse withstand voltage U imp : 800 V Rated insulation voltage U i : 32 VDC Fuse rating: internally short-circuit proof Device insulation: to UL 508 4 A; depending on the number of devices and loads (Y1, Y2 and OUT) Leakage current I r : 0.5 ma Safety inputs "X1" and "X2": Voltage range 3V 5V: low Voltage range 15V 30V: high > 2 ma at 24 V Safety outputs "Y1" and "Y2": p-type, short-circuit proof Rated operating voltage U e1 : max. 4 V under U e Rated operating current I e1 : max. 0.25 A Utilisation category: DC-13 Diagnostic output "OUT": p-type, short-circuit proof Rated operating voltage U e2 : max. 4 V under U e Rated operating current I e2 : max. 0.05A Utilisation category: DC-13 Magnet actuation "IN": Voltage range 3V 5V: low Voltage range 15V 30V: high >5 ma at 24 V Magnet: 100% ED Classification: to EN 954-1: up to control category 4 (with appropriate circuit) to IEC 61508: PFH value = under preparation, suitable for SIL 3 10

Solenoid interlock AZM 200 The non-contact interlock System components G1 G2 System components AES SRB Note Possible safety control modules The safety outputs of the AZM 200 are p-type transistor outputs. Taking the self-test feature of these outputs into account, the safety control modules must tolerate a brief switching-off of the outputs. The cross-wire detection must be deactivated. The following modules allow for a troublefree functioning in combination with the AZM 200: AES 1135 AES 1235 AZR 321 AR SRB 324 ST SRB 301 LC/B SRB-NA-R-C.21 SRB-NA-R-C.22 ESALAN Compact Further information about these devices can be found in our main catalogue Safety Technology. The modules and the structure of the entire safety circuit are determining the obtainable control categories. ESALAN Compact Ordering data Door handle for actuator Rotary button for actuator G1 G2 11

K.A. Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D-42279 Wuppertal Postfach 24 02 63 D-42232 Wuppertal Telefon +49 - (0)2 02-64 74-0 Telefax +49 - (0)2 02-64 74-1 00 E-Mail info@schmersal.de Internet http://www.schmersal.com 3.000 / L.D / 11.2004 / Teile-Nr. 1178229 / Ausgabe 02