INSTRUCTION MANUAL AND PARTS LIST FOR 3SIC AND 4SIC SERIES PUMPS

Similar documents
PRODUCT SERVICE MANUAL. BK6DHZ(C)-250, 275, 312 and 400 PUMPS

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

INSTRUCTION MANUAL AND PARTS LIST FOR PG/RG3D_-187, 218, 250 and 312 SERIES PUMPS

PRODUCT SERVICE MANUAL

PRODUCT SERVICE MANUAL FOR. F312XICR-312_, 325_, 400_ and 437_ Pumps. For Solar Turbines

INSTRUCTION MANUAL AND PARTS LIST FOR PG/RG3D-275 SERIES PUMPS (Idler Cup and Hydrostatic Thrust Designs)

INSTRUCTION MANUAL AND PARTS LIST FOR. (A)E3LB(C)(K)-187, -200, and -250 SERIES PUMPS

Product Service Manual For DLH12DHT SERIES PUMPS

PRODUCT SERVICE MANUAL SERIES 4U AND 6U SERIES 4T AND 6T ROTOR SIZES

Product Service Manual For AA3G Series Pumps Size 187 Through 250

PRODUCT SERVICE MANUAL For G6D-187, 218, 250, 275 and 312 PUMPS

K12DHZ-312P Pump PRODUCT SERVICE MANUAL. Imo Part Number / BOM # 3220/523

INSTRUCTION MANUAL AND PARTS LIST FOR 3G SERIES PUMPS SIZES 95 THROUGH 162

CFHN SERIES PRODUCT SERVICE MANUAL

AA2BIC SERIES PRODUCT SERVICE MANUAL

INSTRUCTION MANUAL AND PARTS LIST FOR 3E CANNED MOTOR PUMPS

PRODUCT SERVICE MANUAL FOR _G3D -350 and 400 SERIES PUMPS (Idler Cup and Hydrostatic Thrust Designs)

PRODUCT SERVICE MANUAL FOR E12L SERIES PUMPS

INSTRUCTION MANUAL AND PARTS LIST FOR A3D SERIES PUMPS

Instruction Manual and Parts List (G323FHF 630M) with Flow Serve Type Q Seal

Instruction Manual & Parts List For H/G323FXFSX-500_ & 800_ Pumps With Flowserve Type BX Cartridge Seal

SERIES G3DB/AG3DB ELEVATOR

Instruction Manual and Parts List For G/H323F 550/550J/550M Pumps with Crane Type 2, 8-1, FS QWD and FS Q Non-Cartridge Seals

PRODUCT SERVICE MANUAL FOR C324AXFX-250/12005 PUMP

INSTRUCTION MANUAL AND PARTS LIST FOR SERIES 8L-630J AND 630M WARNING

PRODUCT SERVICE MANUAL FOR C324AXFS-250/12004 PUMP

PRODUCT SERVICE MANUAL FOR CIG Lip Seal & Weep Hole Design Single Pump

PRODUCT SERVICE MANUAL FOR CIG Lip Seal Double Pumps

TECHNICAL SERVICE MANUAL

Medium and high pressure pumps

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

Maintenance Information

TECHNICAL SERVICE MANUAL

Maintenance Information

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL

PRODUCT OBSOLETED 4Q16

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

Maintenance and Service Instruction

Maintenance Information

PRODUCT OBSOLETED 1Q16

250L Cartridge Dual Seal

TECHNICAL SERVICE MANUAL

Maintenance Information

TECHNICAL SERVICE MANUAL

Maintenance Information

FOR FUTURE REFERENCE SERIES 93HPS

TECHNICAL SERVICE MANUAL HEAVY-DUTY BRACKET MOUNTED PUMPS SERIES 120 and SERIES 124 MODELS J, K, KK, L, LQ, LL AND LM

REPAIR PROCEDURES MANUAL

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL

Maintenance Information

OPERATION MANUAL INTERNAL GEAR PUMP. Models: NG-H, NG-HL, NG-K, NG-KK, NG-L, NG-LQ, NG-LL, NG-LS, NG-Q, NG-QS. Tel: Fax:

TECHNICAL SERVICE MANUAL

SM64155 Maintenance & Repair Manual

This instruction is valid for all ACF/UCF pump models shown on page 2

TECHNICAL SERVICE MANUAL GENERAL PURPOSE BRACKET MOUNTED PUMPS SERIES 115 MODELS G, GX2, H and HX4

PRODUCT OBSOLETED 4Q16

Boston Gear LOR Series

Service Manual #67. Installation and Service Instructions 6000, 7000 & 8000 Series Magnetically Coupled Pumps

Torque-Hub Planetary Final Drive S12A1 & 2 Series Service Manual

TECHNICAL SERVICE MANUAL

Maintenance and Service Instruction

This instruction is valid for all ACF/UCF pump models shown on page 2

SERVICE MANUAL 200 SERIES MOTORIZED 20352, 20452, 20551, 20552, AND MODELS

AV INSTALLATION, OPERATION & MAINTENANCE MANUAL

Installation and Parts Replacement Manual For No. 188D BIO-DISC Reducer

VIS 40 Series Brake Motors Parts and Repair Manual -004

Model 8329 Table of Contents

Page 1 of 26 Oteco Inc. Houston, Texas

Amerigear SF Spindle

3M Overhaul Service Kit

Maintenance Information

IMPORTANT SAFETY NOTICE

SERVICE MANUAL Moyno Mag Drive Series Motorized Pumps with Magnetic Drives 331, 332, 333, 344 MODELS

3M Overhaul Service Kit

PRODUCT OBSOLETED 1Q16

Internal Gear Pumps Installation Manual

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB-SR-S SEISMIC SPRING RETURN SERIES PNEUMATIC ACTUATORS

Safety Precautions Certain service procedures may require the vehicle/machine to be disabled (wheels raised off ground, work function disconnected, et

INGERSOLL -RAND. A WARNING AIR MOTORS OPERATION AND MAINTENANCE MANUAL

H Low Torque Impact Wrench

Hydraulic Motors Repair Instructions

TRANSMISSION 6.7 GENERAL HOME. See Figure The transmission is a five-speed constantmesh type housed in an extension of the crankcase.

CSO / CP PUMPS Vertical Spindle Type Installation, Operation and Maintenance Manual

TC20 Chain Driven Power Take-Off Overhaul Instructions

Opti Line ACG8 Screw pump Maintenance & Start up Instruction

NOTE: Visit our website at for video repair procedures, under the Tools section.

D/G-03 Maintenance. Shutdown Procedure During Freezing Temperatures. Daily. Periodically

LOR Series Trig-O-Matic Lite Overload Release Clutch

POLY TIP-DOWN WINDSHIELD KIT

Installation and Service Instructions. ST Series Pumps

GT SERIES WET PRIME PUMPS SERVICE MANUAL

TECHNICAL BULLETIN. TP Issued Servicing Rockwell s TB Series Trailer Axles with Unitized Hub Assemblies

SERVICE MANUAL. PVR15-Manifold Series Pump. J Design Series INSTALLATION. Ordering Code PVR15 - _ RM - _ - - J

Disassembly and Reassembly for CBB (Double Acting) Series Pneumatic Actuators

LIMITED SLIP DIFFERENTIAL INSTALLATION

Installation, Operation, and Maintenance Manual

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

CALIPER BRAKE INSTALLATION AND MAINTENANCE MANUAL

Transcription:

TM INSTRUCTION MANUAL AND PARTS LIST FOR 3SIC AND 4SIC SERIES PUMPS WARNING This manual, and General Instructions Manual, CA-1 should be read thoroughly prior to pump installation, operation or maintenance. This manual now is identified as part no. SRM00024 Manual No. 3-4SIC Rev. 0 September 1997

READ THIS ENTIRE PAGE BEFORE PROCEEDING FOR THE SAFETY OF PERSONNEL AND TO PREVENT DAMAGE TO THE EQUIPMENT, THE FOLLOWING NOMENCLATURE HAS BEEN USED IN THIS MANUAL: D A N G E R Failure to observe the precautions noted in this box can result in severe bodily injury or loss of life. W A R N I N G Failure to observe the precautions noted in this box can cause injury to personnel by accidental contact with the equipment or liquids. Protection should be provided by the user to prevent accidental contact. CAUTION ATTENTION Failure to observe the precautions noted in this box can cause damage or failure of the equipment. Non-compliance of safety instructions identified by the following symbol could affect safety for persons: Safety instructions where electrical safety is involved are identified by: Safety instructions which shall be considered for reasons of safe operation of the pump and/or protection of the pump itself are marked by the sign: ATTENTION CONTENTS SAFETY AND TABLE OF CONTENTS... A A. GENERAL INSTRUCTIONS... 1 B. INTRODUCTION... 1 C. DESCRIPTION OF THE PUMP... 1 D. ORDERING INSTRUCTIONS... 1 E. OPERATION... 1 F. PARTS LIST AND TORQUE TABLES... 2 G. INSPECTION... 3 H. PUMP MAINTENANCE... 3 I. ASSEMBLY DRAWING... 5 A

A. GENERAL INSTRUCTIONS The instructions found herein cover the disassembly, assembly and parts identification of 3SIC and 4SIC Series pumps. NOTE: Individual contracts may have specific provisions that vary from this manual. For further detailed information and technical assistance to questions not answered by these manuals, please refer to Imo Pump, Technical/Customer Service Department, at (704) 289-6511. This manual cannot possibly cover every situation connected with the installation, operation, inspection, and maintenance of the equipment supplied. Every effort was made to prepare the text of the manual so that engineering and design data is transformed into the most easily understood wording. Imo Pump must assume the personnel assigned to operate and maintain the supplied equipment and apply this instruction manual have sufficient technical knowledge and experience to apply sound safety and operational practices which may not be otherwise covered by this manual. WARNING If installation, operation and maintenance instructions are not correctly and strictly followed and oboserved, injury to personnel or serious damage to pump could result. Imo Pump cannot accept responsibility for unsatisfactory performance or damage resulting from failure to comply with instructions. B. INTRODUCTION This instruction manual covers series 3SIC and 4SIC Imo pumps. This series of pumps has been designed for use in hydraulic elevator submerged applications. The model, construction and material of each pump is identified on the pump nameplate. Definitions of model designators are identified in Figure 1. Figure 1. Model Designator Definitions X X XXX X Design Modifications: A, B, D, E Series 3SIC, 4SIC Rotor Lead Rotor Size: 187, 200, 218, 250, 275 (Examples) C. DESCRIPTION OF PUMP The 3SIC and 4SIC series pumps are positive displacement, rotary screw pumps consisting of a precision bored housing that encloses a driven screw (power rotor) and two intermeshing following screws (idler rotors). These screws when rotating form a succession of closures or cavities. As they rotate, the fluid is moved axially from the inlet to the outlet port in a continuous, uniform flow with minimum fluid pulsation and pump noise. D. ORDERING INSTRUCTIONS To order a replacement pump, contact Imo service representative with the pump model number, serial number and manufactured date. This information can be found on the pump s nameplate. E. OPERATION E.1 LIQUID LIMITATIONS Never operate with thin liquids such as solvents or water. The pump is designed for liquids having the general characteristics of oil. 1

E.2 OPERATING LIMITATIONS CAUTION ATTENTION Operating conditions, such as speed, fluid viscosity, temperature inlet pressure, discharge pressure, filtration, duty cycle, drive type, mounting, etc., are interrelated. Due to these variable conditions, the specific application limits may be different from that of the operational limitations. This equipment must not be operated without verifying the system s operating requirements are within the pump s capabilities. Under no circumstances are the operating limits (specified in Table 1) to be exceeded without specific approval from Imo Pump. MAXIMUM SPEED... 3600 RPM VISCOSITY... 60 SSU (10.3 cst) Minimum, if over 5000 SSU (1079 cst) contact Imo Pump NOTE: Consult factory for allowable operating viscosity at specific speeds and pressures. DO NOT alter design viscosity without prior consultation with Imo Pump TEMPERATURE... 0 to 180 F (-18 to 82 C) Maximum INLET PRESSURES... 3SIC and 4SIC Pump types must be submerged to a depth of at least 6 in. (15.24 cm) from top of pump to top of fluid DISCHARGE PRESSURE*... See Elevator Pump Data Book DRIVE... Direct drive only FILTRATION... Always use inlet strainer supplied with pump MOUNTING... Flange mounted F. PARTS LIST AND TORQUE TABLES Table 1. Pump Operating Limits Table 2. Pump Parts List IDP QTY DESCRIPTION IDP QTY DESCRIPTION 1 1 Power Rotor 10 4 Hex Bolt(s) 2 1 Key 11 2 Idler Rotor(s) 3 1 Truarc Ring(s) 12 2 Spacer(s) 4 1 Truarc Ring(s) 13 1 Thrust Plate 5 1 Bearing 14 2 Hex Bolt(s) 6 1 Inboard Cover 15 1 Strainer 8 1 Rotor Housing 16 1 Strainer Clamp 9 2 Lockwasher(s) 17 4 Hex Bolt(s) Table 3. Fastener Descriptions and Torque Tightening Values PUMP IDP DESCRIPTION TORQUE (English) TORQUE (Metric) 17 HEX BOLT 100 ± 5 lb. in. 12 ± 3 Nm SIC 187/200 10 CAP SCREW 18 ± 2 lb. ft. 25 ± 3 Nm 14 CAP SCREW 18 ± 2 lb. ft. 25 ± 3 Nm 17 HEX BOLT 100 ± 5 lb. in. 12 ± 3 Nm SIC 218 10 HEX BOLT 50 ± 2 lb. ft. 68 ± 3 Nm 14 HEX BOLT 18 ± 2 lb. ft. 25 ± 3 Nm 17 HEX BOLT 100 ± 5 lb. in. 12 ± 3 Nm SIC 250 10 HEX BOLT 50 ± 2 lb. ft. 68 ± 3 Nm 14 HEX BOLT 18 ± 2 lb. ft. 25 ± 3 Nm 17 HEX BOLT 100 ± 5 lb. in. 12 ± 3 Nm SIC 275 10 HEX BOLT 75 ± 5 lb. ft. 102 ± 7 Nm 14 HEX BOLT 18 ± 2 lb. ft. 25 ± 3 Nm 2

G. INSPECTION The interval for inspection and replacement of worn parts varies with the properties of the pumped liquid and can only be determined by experience. All parts of the 3SIC and 4SIC series pumps are lubricated by the pumped fluids. Pumping liquid which contains abrasive materials or liquid that is corrosive, will significantly reduce service life and call for shorter service intervals. A worn pump will be noticeable by excessive vibration, noise, reduction in flow or reduction in pressure. H. PUMP MAINTENANCE WARNING Failure to observe precautions while installing, inspecting, and maintaining the pump can cause injury to personnel from accidental handling, liquids that may harm skin or clothing, fire hazard risks from flammable liquids, or injury from high pressure fluid jets. DANGER BEFORE working on equipment, make sure all power to the equipment is disconnected and locked-out. H.1 GENERAL COMMENTS Part number identifiers (IDPs) contained within parenthesis such as (8) refer to the circled numbers shown on Assembly Drawings, Figures 2 and 3. Close all pump line valves. H.2 TOOLS REQUIRED The procedures described in this manual require common mechanics hand tools, a torque wrench and a suitable lifting device (such as) slings, straps, etc. H.3 PUMP DISASSEMBLY CAUTION ATTENTION Fluid leakage from disassembly of pump may make the floor slippery and cause personal injury. NOTE: The 3SIC and 4SIC pumps incorporate highly finished precision parts that must be handled carefully to avoid damage to critical machined surfaces. The parts removed should be tagged for identification and their exact positions in the pump carefully noted so that new parts, or theremoved parts, are properly replaced. STEP 1. Remove Pump from Driver. Remove bolts (17) and washers (18). Slide pump out and away from driver. Place pump on workbench. If replacing bearing, remove key (2) from power rotor (1) shaft keyway. STEP 2. Remove Strainer (suction side). Remove strainer clamp (16) and strainer (15). STEP 3. Remove Thrust Plate. Remove bolts (14) lockwashers (9) thrust plate (13) and spacers (12). STEP 4. Remove Idler Rotors. Remove idler rotors (11) from the bore of the housing (8) by pulling and rotating rotors in a clockwise direction. STEP 5. Remove Power Rotor (discharge side) 1. Using snap-ring pliers remove the Truarc rings (4) from the groove of inboard cover (6). 2. Holding shaft of power rotor (1) pull rotor from inboard cover (6) and rotor housing (8). 3

STEP 6. Remove Inboard Cover. Remove bolts (10) and inboard cover (6). STEP 7. Remove Bearing from Power Rotor (Optional step for bearing removal). 1. Using a screwdriver, remove the outer Truarc ring halves (3). 2. Using a bearing puller or press, remove ball bearing (5) from power rotor (1). NOTE: Imo Pump strongly recommends replacement of the ball bearing (5) every time the bearing is pressed-off the power rotor. H.4 PUMP ASSEMBLY NOTE: Prior to pump assembly, all parts should be cleaned and inspected for nicks, burrs or gouges. When ready for assembly, wipe all parts, including bolts, with SAE 30 lubricating oil. STEP 1. Install Inboard Cover (discharge side) Install rotor housing (8) on inboard cover (6) using bolts (10). Torque bolts as follows: 1. Using Figure 2, torque bolts (10) to 18 ± 2 lb. ft. 2. Using Figure 3, torque bolts (10) to 50 ± 2 lb. ft. 3. For all SIC-275 series pumps, torque bolts (10) to 75 ± 5 lb. ft. STEP 2. Install Bearing (If previously removed). Using an arbor press, install ball bearing (5) onto power rotor (1) shaft by pushing on bearing inner race ring only. CAUTION Bearing service life could be significantly reduced if the bearing is pushed on by its outer race ring. NOTE: STEP 3: STEP 4: STEP 5: STEP 6: STEP 7: STEP 8: STEP 9: Take care to press on the bearing inner race only. Press bearing down until the inner race of ball bearing (5) is positioned against power rotor (1) shoulder. Install Truarc rings (3) in groove of power rotor(1). Install Power Rotor. Install the power rotor (1) into inboard cover (6) and rotor housing (8). Install Truarc Rings. Install Truarc rings set (4) next to ball bearing (5) in groove of inboard cover (6). Install Idler Rotors. Install idler rotors (11) into rotor housing (8) idler bores, by meshing threads and pushing and turning idlers (11) while inserting. Install Thrust Plate. Install spacers (12) and thrust plate (13) on rotor housing (8) using bolts (14) and lockwashers (9). Torque bolts to a value of 18 ± 2 lb. ft. Install Strainer. Install strainer (15) and strainer clamp (16). Reinstall Pump to Driver. Install key (2) in power rotor (1) keyway. Slide pump shaft into driver shaft. Mount Pump and Driver. Install bolts (17) into inboard cover (6) and torque to 100 ± 5 lb. ft. 4

OUTLET INLET CLOCKWISE RO TATION Figure 2. Assembly Drawing for 3SIC-187, -200 and 4SIC-187, -200 Series Pumps OUTLET INLET CLOCKWISE RO TATION Figure 3. Assembly Drawing for 3SIC-218, -250 and 4SIC-218, -250, -275 Series Pumps NOTE: Actual pump may differ slightly from figure. 5