SM 1231 ANALOGINPUT MODULE

Similar documents
Overview. Application. Function. Design. Home

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

INTERNATIONAL METAL ENGINEERING

Process controller. for pneumatic and electric actuators. Process controller V. Process controller

2-channel analog input module; Pt100 / RTD; for resistance sensors

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

Product Data Sheet DV5214 NU

Differential Pressure Sensors

VersiVision - High Definition Fiber Optic Video

HVAC Products. Introducing the SED2 Variable Frequency Drives

Product Data Sheet 8412 NHU-519

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Product Data Sheet 632 NU-006

JUMO ecotrans Lf 01/02

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

Point level measurement Capacitance switches

IB IL 24 SEG/F. Function. INTERBUS Inline Segment Terminal With Fuse. Data Sheet 5656B

User s Manual. K Type Thermometer DT1311, DT1312

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Moving Coil Indicators with direct temperature sensor input

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

DC3N Non-Regenerative DC Drives

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

Wind display type WSDI-2 DATA SHEET

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Pneumatic Timer. TECHNICAL DATA Display digit roll s, s or s, depending on version Operating pressure 2...

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

MINI MCR-SL-UI-UI(-SP)(-NC)

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Power Supplies. 11/2 Introduction

NOT RECOMMENDED FOR NEW DESIGNS. Wind display type WSDI-2 DATA SHEET. Watertight. Displays

Encoder WDGA 58V CAN SAE J1939

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

1LG0 Low-voltage Motors

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Product Data Sheet 624 NR. The engineer's choice

Analog Input Terminal

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

ABB i-bus KNX DG/S x DALI-Gateway Basic

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Screw-in resistance thermometers with plug connector

ASZ... Potentiometers. Building Technologies Division. ASZxx.3x

Product Data Sheet 4118 N/ The engineer's choice

Product Data Sheet 4184 N/17X. The engineer's choice

Temperature Controller (Heat Pumps)

Analog Output Terminal

Electronic Circuit Breaker ESS20-0..

Plug-in relays Mini ISO relays

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Differential pressure sensor

Product Data Sheet ACi 4420 HHR

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

Overview of types. Technical data. Safety notes

JUMO MIDAS S05 Pressure transmitter Type

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Data Sheet for Precision Potentiometer

Preferred Series 215 kw to 1500 kw. Catalog DA /2000

See «Overview of types»

ELEMENT. Product family datasheet. Constant Voltage Non dimmable

INTECH Micro 2300-RTD6

Company name: GSI Created by: Xiao Ying Wong Phone: Date: 10/03/2017 Client: Client Number: Contact:

Safety technique. Emergency Stop Module BH 5928, BI 5928

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Product Data Sheet 8314 HR-197

Metso Conductivity for sensor series 9400 and 9500

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

Differential Pressure Sensors

Ground Resistance Tester Model 3620 & 3620 Kits

Power Switching Devices

SINAMICS G110 Inverter chassis units 0.12 kw to 3 kw

MS General Information Extended Product Type: MS

Pilot-Operated Proportional DC Valve Series D*1FH

TESTO 350 Upgrades / Accessories / Spare Parts. Replacement Sensors

Product Data Sheet 8412 N/ The engineer's choice

Product Data Sheet 4184 NXHH

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

Product Data Sheet 3214 JH3-195

Level Measurement Point level measurement - RF Capacitance switches

ARI-PACO 2G 1,6 D/Y. Electric thrust actuator. Electric thrust actuator ARI-PACO 2G 1,6 D/Y. Electric thrust actuator. ARI-PACO 2G 1,6 D 1,6 kn

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

MELT PRESSURE TRANSMITTERS K7 SERIES PERFORMANCE LEVEL c

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

MOM2 Handheld High Current Micro-ohmmeter

TEL-TRU MANUFACTURING COMPANY DIGITAL THERMOMETERS

Product Flyer ELC ELECTRONIC LAMP CONTROL

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

Product Data Sheet 4184 NXHH

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Advanced Test Equipment Rentals ATEC (2832)

Encoder WDG 58V.

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Product Data Sheet 8414 NGH

Transcription:

SM 1231 ANALOGINPUT MODULE Function The SM 1231 analog input signal modules convert analog signals from the process into digital signals for internal processing by the SIMATIC S7-1200. Technical specifications Page 879 Mar 2008 Siemens ITS

Technical specifications 6ES7 231-4HD30-0XB0 6ES7 231-4HF30-0XB0 SM 1231 AI 4x13 bit SM 1231 AI 8 x 13 bit Supply voltage 24 V DC Yes Yes Input current Current consumption, typ. 45 ma 45 ma from backplane bus 5 V DC, 80 ma 90 ma typ. Power losses Power loss, typ. 1.5 W 1.5 W Analog inputs Number of analog inputs 4; Current or voltage differential inputs 8; Current or voltage differential inputs Page 880 Mar 2008 Siemens ITS

permissible input frequency for± 35 V ± 35 V current input (destruction limit), max. permissible input voltage for 35 V 35 V voltage input (destruction limit), max. permissible input current for voltage input (destruction limit), max. 40 ma 40 ma Cycle time (all channels) max. 625 µs 625 µs permissible input current for 40 ma 40 ma current input (destruction limit), max. Input ranges Voltage Yes; ±10 V, ±5 V, ±2.5 V Yes; ±10 V, ±5 V, ±2.5 V Current Yes; 0 to 20 ma Yes; 0 to 20 ma Thermocouple No No Resistance thermometer No No Resistance No No Input ranges (rated values), voltages -10 V to +10 V Yes Yes Input resistance (-10 V to +10 V) 9 MOhm 9 MOhm Page 881 Mar 2008 Siemens ITS

-2.5 V to +2.5 V Yes Yes Input resistance (-2.5 V to 9 MOhm 9 MOhm +2.5 V) -5 V to +5 V Yes Yes Input resistance (-5 V to +5 9 MOhm 9 MOhm V) Input ranges (rated values), currents 0 to 20 ma Yes Yes Input resistance (0 to 20 250 ohms 250 ohms ma) Temperature compensation Parameterizable No No Analog outputs Number of analog outputs 0 0 Analog value creation Integrations and conversion time/ resolution per channel Resolution with overrange 12 bit; + sign 12 bit; + sign (bit including sign), max. Integration time, Yes Yes parameterizable Interference voltage suppression Page 882 for interference 40 db, DC to 60 V for interferencemar frequency 2008 50 / 40 db, DC to 60 V for interference frequency Siemens 50 ITS/

Interference voltage suppression for interference frequency f1 in Hz 40 db, DC to 60 V for interference frequency 50 / 60 Hz Smoothing of measured values Parameterizable Yes Yes Step: None Yes Yes Step: low Yes Yes Step: Medium Yes Yes Step: High Yes Yes Errors/accuracies Temperature error (relative to input area) Basic error limit (operational limit at 25 C) Voltage, relative to input area Current, relative to input area Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency 40 db, DC to 60 V for interference frequency 50 / 60 Hz 25 C ±0.1 % to 55 C ±0.225 C ±0.1 % to 55 C % total measurement range ±0.2 % total measurement range +/- 0,1 % +/- 0,1 % +/- 0,1 % +/- 0,1 % Page 883 Mar 2008 Siemens ITS

common mode voltage, max. 12 V 12 V Interrupts/diagnostics/status information Alarms Alarms Yes Yes Diagnostic alarm Yes Yes Diagnoses Diagnostic functions Yes Yes Monitoring the supply voltage Yes Yes to the electronics Wire break No No Diagnostics indication LED for status of the inputs Yes Yes for maintenance Yes Yes Galvanic isolation Galvanic isolation analog outputs between the channels and the power supply of the electronics Climatic and mechanical conditions for storage and transport No Page 884 Mar 2008 Siemens ITS No

Climatic conditions for storage and transport Free fall 0.3 m; five times, in dispatch package 0.3 m; five times, in dispatch package Drop height, max. (in packaging) Temperature -40 C to +70 C -40 C to +70 C Permissible temperature range Air pressure acc. to IEC 60068-2-13 1080 to 660 hpa 1080 to 660 hpa Permissible air pressure Mechanical and climatic conditions during operation Climatic conditions in operation Temperature Permissible temperature range Air pressure acc. to IEC 60068-2-13 0 C to 55 C horizontal installation 0 C to 45 C vertical installation 0 C to 55 C horizontal installation 0 C to 45 C vertical installation Page 885 Mar 2008 Siemens ITS

1080 to 795 hpa 1080 to 795 hpa Permissible air pressure Pollutant concentrations S02: < 0.5 ppm; H2S: < 0.1 SO2 at RH < 60% ppm; RH < 60% without condensation condensation-free Degree and class of protection IP20 Yes Yes Standards, approvals, certificates CE mark Yes Yes C-TICK Yes Yes FM approval Yes Yes Connection method required front connector Yes Yes Mechanics/material Type of housing (front) Plastic Yes Yes Dimensions Width 45 mm 45 mm Height 100 mm 100 mm Depth 75 mm 75 mm Weight S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free Page 886 Mar 2008 Siemens ITS