TPAK Series COOLANT PUMP

Similar documents
TPHK Series Immersible Pump

TPHK Series Immersible Pump

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

Duplex Booster System Instruction Manual

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

Walrus Pump Co., Ltd.

Unilift KP 150, KP 250, KP 350

AUTOMATIC SUBMERSIBLE UTILITY PUMP

GARDEN HOSE UTILITY PUMP

ADI-125/750 ADI-125/1500 ADI-125/2500

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS

Installation and Operating Instructions for Davey HS20-65Y2 Multistage Pump

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

ESE Series Cast Iron Sewage Pumps

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Pump Installation and Service Manual HRS Hydromatic Retractable System

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

OWNERS MANUAL JANUARY 2007 ISO

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

SPC-PANEL Simplex, Single Phase Pump Control Panel

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

User Guide IGD Series

Level One Electric Vehicle Charging Station Wall Mount Product Guide

StormPro BA Series Sump Pump

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

MIL-24/2600Q MIL-24/3200DQ

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

SUNC3000 / Item #40885

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

SUBMERSIBLE MINI-PUMP

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Matala. VersiFlow Series. Instruction and Maintenance Manual

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

OWNERS MANUAL JANUARY 2007 ISO

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER SYSTEM

DC to AC Power Inverters

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

10 Year Limited Warranty

DC to AC Power Inverters

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Air Compressor. Owner s Manual

OWNER S MANUAL STOP. Models: Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof

SUPER PUMP OUT SYSTEM

Installation Instructions Receiver Rack (Part # 7700) Universal Application

TW1000E-20W-70-DCA In Enclosure w/ Double Check Assembly VARIABLE SPEED BOOSTER SYSTEM

Operators Manual. Recirculating Chiller /06/08

SHALLOW WELL JET PUMP

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

HUNTER PUMPS ELECTRIC FIRE PUMP SET

STAR STOP SHALLOW WELL JET PUMP

Tank Monitor. Instruction manual DTM01. Tank Monitor

Owner s Manual Drill and Light Weight Portable Utility Pumps

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

SELF PRIMING CHEMICAL SERVICE PUMPS

All products subject to this warranty must be returned for examination, repair or replacement to:

TW G-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

SUBMERSIBLE SWIMMING POOL DRAINER

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Owner s Manual Hydro-X Xtreme Xtractor

StormPro BCV400 Sewage Ejector Pump

Pure Sine Wave Inverter 600W-24V User Manual

Grid Tied Limiter User Manual

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

Raydot LLC 24 Actuator (115 VOLT)

High Velocity Series Air Curtains

HALLMARK INDUSTRIES INC

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

Grundfos.bk Page 1 Thursday, June 11, :59 PM GRUNDFOS INSTRUCTIONS. CRN MAGdrive. Installation and operating instructions

WARNINGS, CAUTIONS AND NOTES

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

Environmental Series Air Curtains

Installation and Operating Instructions. WHISPER Series, TYPHOON C & T-Series Swimming Pool Pumps

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

Deluxe ASA Halogen Spot/Flood Light

Power. On Your Terms.

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

PRE-PLUMBED SEWAGE SYSTEM

Transcription:

TPAK Series COOLANT PUMP Instruction Manual ISO 9001 Certified WALRUS PUMP CO., LTD.

EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No.83-14, Dapiantou, Sanzhi Dist., New Taipei City 252, Taiwan Declare that the machinery described: Name : Water Pump Model : TPAK Series Conform to the following directive: 2006/42/EC Machinery directive 2006/95/EC Low voltage directive 2004/108/EC EMC (Electromagnetic compatibility) directive Refer to the following standards: EN ISO 12100:2010 EN ISO 13857:2008 EN 809:1998+A1:2009 EN 60204-1:2006 EN 60335-1:2012 EN 60335-2-41:2003 EN 61000-6-2:2005 EN 61000-6-3:2007 R&D department manager: Kao Tien-chuan Manager: ~ 2 ~

Please read this instruction manual carefully before installing your new system as failures caused by incorrect installation and operation are not cover by the warranty. 1. Application The TPAK Series coolant pump is design for the circulation and spraying of cooling lubricants, especially for machine tools. This series may use on all machine tools performing Turning, Milling, Drilling, Cutting, Slitting, Grinding etc. operation. It is suitable to carry liquids such as water, coolant, light oil and other clean, non aggressive matters. 2. Model Code 3. Operating Limits 1. Ambient temperature : Max. +40 C 2. Liquid temperature range: 0 C to 90 C 3. Operating pressure : Max. 10 kg/cm² 4. Head: 50Hz : Up to 12M 60Hz : Up to 17M 4. Installation The pump has hot surface on the motor. It must be installed so that persons cannot accidentally come into contact the hot surface. 4.1.Pump location Note : The pumps can only be mounted in vertical position, see fig.1. Fig.1 4.2.Submerged depth : L (mm) To avoid dry running and damage the pump during operation, the minimum pump submerged depth as follows. Min. L TPAK 2-18 Model TPAK 2 TPAK 4 TPAK 8 TPAK 15 L (mm) 50 60 90 120 Installation length 18 = 180 mm 25 = 250 mm Output power 2 = ¼ HP 4 = ½ HP 8 = 1 HP 15 = 1.5 HP Model name 4.3.Maximum liquid level Min. 20 mm ~ 3 ~

5. Electrical Connection 5.1 The electrical connection should be carried out in accordance with local regulations. Never make any connections unless the electricity supply has been switched off. 5.2. The electrical hazard warning mark is placed outside the connection box. Be careful. 5.3. Electrical data (voltage and frequency) are shown on the pump nameplate. Verify if these data match your electricity supply. A Residual current device (RCD, 30mA) should be installed and the grounding be properly connected for your safety. 5.4. Motors must be connected to a motor-protective circuit breaker which can be manually reset. Set the motor-protective circuit breaker according to the rated current of the motor. See nameplate. 5.5. Make electrical connection in accordance with connecting diagram located inside the connection box. The motor current must be within the rated amps range indicated on nameplate. Three phase motor requires a magnetic starter for safety. 5.6. For three phase motors, look down from the fan cover the correct direction of rotation is rotate clockwise. if wrong rotation, you can reverse the direction of rotation by interchanging any two of the incoming supply wires. 5.7. Motors must equipped overload protector and open-phase protector to avoid motor damage. 6. Start-up Before starting the pump, make sure the following: 6.1. For three phase motors, verify if the rotating direction is correct. It should be clockwise, look down from the motor fan cover. 6.2. All piping joints are completely tight. Leakage in piping may cause the pump hydraulic loss. 6.3. The pump is filled with liquid. 6.4. The suction filter is not blocked by any foreign objects. 7. Operation and Maintenance It is dangerous to operate the pump against a closed discharge outlet because it will cause extremely high liquid flow temperature and damage the pump in a few minutes. 7.1. Periodic checks The following checks should be carried out periodically to ensure the normal operation. 7.1.1. Check the quantity of liquid and operating pressure. 7.1.2. Check there are no leaks on piping joints. 7.1.3. Check the tripping of the motor starter. 7.1.4. Check that all controls are functioned normally. 7.2. The pump must not be used to transfer explosive liquids. In systems with hot liquids (over 60 C), extra caution should be exercised to prevent from personal injury. 7.3. The pump should not be used to transfer toxic or contaminated liquids. Please carefully follow all instructions in the manual as Walrus may refuse to accept the contaminated pump for servicing. 7.4. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent. ~ 4 ~

8. Sound pressure level 9. Wiring diagram Motor db(a) TPAK 2 <70 TPAK 4 <70 TPAK 8 <70 TPAK 15 <70 3Ø W2 U1 L1 CONNECTING U2 V2 W2 U2 V2 V1 W1 U1 V1 W1 L2 L3 L1 L2 L3 LOW VOLTAGE HIGH VOLTAGE 10. Fault finding (Make sure electricity supply has been switched off before attempting to diagnose any fault) Fault Cause a. No electricity supply b. Fuses are blown. 10.1 Motor does not start c. Motor overheating relay tripped. d. Defective magnetic contactors. e. Control circuit malfunction. a. Fuses blown or breakers tripped. 10.2. Motor cut out during operation. b. Overheating relay tripped. c. Control circuit malfunction. d. Pump locked up by foreign objects. 10.3. Pumped capacity is not constant. a. Pump impeller blocked by impurities. b. Insufficient liquid level in the tank. (See Sec. 4.2) a. Impellers damage. 10.4. Pump runs but gives no liquid. b. Liquid level is too low (See Sec. 4.2) ~ 5 ~ c. Incorrect rotating direction.

11. Dimensions F G C E J K A D J B H L I Model DIMENSIONS: ( mm ) A B C D E F G H I J K N.W weight (kg) TPAK 2-15 325 150 175 24 Rp ½ 80 112.5 Ø120 Ø120 160 4xØ8 PCD158 9.5 TPAK 2-18 355 180 175 24 Rp ½ 80 112.5 Ø120 Ø120 160 4xØ8 PCD158 10.0 TPAK 2-25 425 250 175 24 Rp ½ 80 112.5 Ø120 Ø120 160 4xØ8 PCD158 10.6 TPAK 4-15 385 150 235 28 Rp ¾ 85 111 Ø135 Ø135 170 4xØ9 PCD170 11.2 TPAK 4-18 415 180 235 28 Rp ¾ 85 111 Ø135 Ø135 170 4xØ9 PCD170 11.9 TPAK 4-25 485 250 235 28 Rp ¾ 85 111 Ø135 Ø135 170 4xØ9 PCD170 12.7 TPAK 8-18 456 180 276 29 Rp 1 95 111 Ø150 Ø150 190 4xØ9 PCD185 15.5 TPAK 8-25 526 250 276 29 Rp 1 95 111 Ø150 Ø150 190 4xØ9 PCD185 17.1 TPAK 15-25 573 248 325 42 Rp 1½ 122 124 Ø180 Ø180 200 4xØ9 PCD210 24.0 ~ 6 ~

12. SPECIFICATION Model PH (Ø) Cycle (Hz) Input Power (W) Volts (V) Full load current (A) TPAK 2 3 50 270 200-255 / 380-440 1.0-1.3 / 0.6-0.8 60 350 200-255 / 380-480 1.2 / 0.7 TPAK 4 3 50 440 200-255 / 380-440 1.5-1.9 / 0.9-1.2 60 620 200-255 / 380-480 2.0 / 1.1 TPAK 8 3 50 930 200-255 / 380-440 3.1-4.4 / 1.9-2.6 60 1320 200-255 / 380-480 4.0 / 2.4 TPAK 15 3 50 1300 220 / 380 4.8 / 2.8 60 2000 220 / 380 5.4 / 3.1 ~ 7 ~

Limited Warranty Products manufactured by Walrus Pumps Co (Walrus) are warranted to the first user only to be free of defects in material and workmanship for a period of 12 months from date of installation, but no more than 24 months from date of shipment. Walrus' liability under this warranty shall be limited to repairing or replacing at our election, without charge, FOB Walrus' distribution center or authorized service agent. Walrus will not be liable for any cost of removal, installation, transportation or any other charges that may arise in connection with warranty claim. The warranty period commences on the date of original purchase of the equipment. Proof of purchase and installation date, failure date, and supporting installation data must be provided when claiming repairs under warranty. This warranty is subject to due compliance by the original purchaser with all directions and conditions set out in the installation and operating instructions. Failure to comply with these instructions, damage or breakdown caused by fair wear and tear, negligence, misuse, incorrect installation, inappropriate chemicals or additives in the water, inadequate protection against freezing, rain or other adverse weather conditions, corrosive or abrasive water, lightning or high voltage spikes or through unauthorized persons attempting repairs are not covered under warranty. Walrus will not be liable for any incidental or consequential damages, losses, or expenses, arising from installation, use, or any other causes. There are no express or implied warranties, including merchantability or fitness for a particular purpose, which extend beyond those warranties described or referred to above. Certain states do not permit the exclusion or limitation of incidental or consequential damages or the placing of limitations on the duration of an implied warranty, therefore, the limitations or exclusions herein may not apply. This warranty sets forth specific legal rights and obligations, however, additional rights may exist, which may vary from state to state. Supersedes all previous publications WALRUS PUMP CO., LTD. Web: w ww.walru spump.com CC70D0004DA00EW0R03