Drying ovens FD 53 - Drying oven with forced convection FD series units are primarily used in applications needing rapid drying and sterilization. Totally homogenous temperature distribution, rapid dynamic response, and a special air turbine which was developed by us and has 20 % higher output, have made the FD series a genuine time-saving device. Performance features and equipment : Electronically controlled APT.line preheating chamber assuring temperature accuracy and reproducible results Temperature range 5 C (32 ºF) above ambient temperature up to 300 C (572 F) DS controller with integrated timer 0 to 99 h Digital temperature setting with an accuracy of one degree Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm Adjustable front ventilation flap slide and rear exhaust ø 50 mm (1.97 inch) Units up to 115 liters are stackable 2 chrome-plated racks included BINDER test certificate 04/02/2009
Technical specification FD 53 FD 53 Exterior dimensions Width (mm/inch) 634 / 25.0 Height (inclusive feet/castors) (mm/inch) 617 / 24.3 Depth (mm/inch) 575 / 22.6 Plus door handle, I-panel and exhaust duct (mm/inch) 105 / 4.1 Wall clearance rear (mm/inch) 100 / 3.9 Wall clearance side (mm/inch) 160 / 6.3 Exhaust duct outer- Ø (mm/inch) 52 / 2.1 Steam space volume (l/cu.ft.) 77 / 2.7 Number of doors 1 Interior dimensions Width (mm/inch) 400 / 15.8 Height (mm/inch) 400 / 15.8 Depth (mm/inch) 330 / 13 Interior volume (l/cu.ft.) 53 / 1.9 Racks, chrome-plated (number standard/max.) 2 / 5 Load per rack (kg/lbs.) 15 / 33 Permitted total load (kg/lbs.) 40 / 88 Weight of the unit (empty) (kg/lbs.) 44 / 97 Temperature data Temperature range, 5 C (41 F) above ambient up to ( C / F) 300 / 572 Temperature variation 1) at 70 C (± C) 0,8 at 150 C (± C) 2 at 300 C (± C) 3.7 Temperature fluctuation (± C) 0.3 Heating up time 1), 2) to 70 C (Min.) 7 to 150 C (Min.) 22 auf 300 C (Min.) 45 Recov. time after door was opened for 30 sec. at 70 C (Min.) 2 at 150 C (Min.) 4 at 300 C (Min.) 9 Air change data Air change at 70 C (x/h) 59 at 150 C (x/h) 64 at 300 C (x/h) 53 Electrical data Housing protection acc. to EN 60529 IP 20 Nominal voltage (±10 %) 50 / 60 Hz (V) 230 Nominal power (kw) 1.2 Energy consumption at 70 C (W) 172 at 150 C (W) 429 at 300 C (W) 951 1) value without window 2) up to 98 % of the set value 3) The air change depends on the inner chamber- and ambient temperature and is subject to significant individual variance. The indicated air change rate represents average values for standard equipment. Individual measurement of air change rate in acc. To ASTM D 5374 are optionally available. All technical specification are specified for units with standard equipment at an ambient temperature of 25 C (77 F) and a voltage fluctuation of ±10 %. The temperature data are determinated in accordance to factory standard following DIN 12880, part 2 respecting the recommended wall clearances of 10 % of the height, width and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to alter technical specifications at all times.
ptions and accessories FD series Access ports With silicon plugs for inserting external measuring devices into the chamber. Access ports with 10, 30, 50 mm (0.4, 1.2, 2 inch) diameter. Door with window and interior lighting For optimum process control in the interior, available for all equipment sizes. Lockable door Prevents unauthorized access and interference with processes in the chamber. Calibration certificates and validation BINDER can significantly reduce the time and effort needed for equipment qualification. We draw on unparalleled knowledge of our equipment applications and years of experience in certification.
ptions and accessories FD series Access port with silicone plugs, 10 mm (0.39 inch), 30 mm (1.18 inch), 50 mm (1.97 inch), 100 mm (3.94 inch) Independent adjustable temperature safety device, Class 3.1 (DIN 12880) Analog temperature output, 4-20 ma, with 6 - pin DIN socket (output not adjustable) ver temperature alarm, acoustic, can be switched off. Temperature limit can be set at the independent, adjustable temperature safety device class 2 Anti-slip rubber pads for safe stacking (4 pieces) Temperature measurement acc. to DIN 12880 (27 measuring points) at 150 C (302 F) or at specified temperature with measuring protocol and certificate Factory calibration certificate. Measurement in center of chamber at 150 C (302 F) or at specified testing temperature Extension to factory calibration certificate. Each additional measurement at an additional measuring point or temperature Rack, chrome - plated or stainless steel Shelf, perforated, stainless steel Lockable door FKM door gasket Door with window and interior lighting, 15 W (230 x 230 mm / 9.06 x 9.06 inch) FD 53
Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK ffice, using the details below. UK ffice Keison Products, P.. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.