SPECTRACOOL Slim Fit Air Conditioners (Surface-Mount Units Only) Quick Start Operation Guide

Similar documents
P70, P72 and P170 Series Controls for High Pressure Applications

P70, P72, and P170 Series Controls for High Pressure Applications

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

Application Engineering

ZHA/ZHB SERIES WARNING

Mizer Single Pump and Starter Box

D M S 760 C01 A A 1 1

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

R134a R134a R13. 4a R134a R134a R134

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

POWERLINE 2000 Energy Management System TM

Quik-Spec Coordination Panelboard Specifications

P5RF Series Single Packaged Air Conditioner Single Phase

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS

P445 Series Electronic Lube Oil Control

S /5000 BTU/Hr. 1000/1500 Watt

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls. Instruction Sheet PA October 2007

ACCESSORY KIT INSTALLATION INSTRUCTIONS

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton.

Q5RD Series Single Packaged Heat Pump, Single Phase

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls

Electronically Commutated Motors

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

ESE Series Cast Iron Sewage Pumps

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

Application Engineering

MODEL SCA Installation and Operation Manual Important:

NM650 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

WATER SOURCE HEAT PUMPS

Corp L3 Revised CB17/CBH17 SERIES UNITS SPECIFICATIONS CB17-95V CBH17-95V

FM800R SERVICE PARTS

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

V High Efficiency Series

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

ACCESSORY KIT INSTALLATION INSTRUCTIONS

CHILLER START UP PROCEDURE FORM DOC. N (DOC.N BELOW TO BE RETURN TO AERMEC)

8300 Series Installation Guidelines

13 SEER CONDENSING UNITS

DIMENSION AND SELECTION GUIDE

P70, P72, and P170 Controls for Low Pressure Applications

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Stylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a

Eclipse 2000 Service Parts

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL

14.5 SEER VALUE SERIES CONDENSING UNITS

Q7RE Series Single Packaged Heat Pump, Single Phase

Installation Instructions

10+ SEER - AIR CONDITIONER

Addendum. Remote Air-Cooled Condenser

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

EVoInnovate EVSE Model Numbers: EVO & EVO User Manual & Installation Guide. Revision 1.0

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

Water to Water Geothermal Heat Pump 3-Phase Models Both 208 & 480

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

Pretest Module 24 Three-phase Service Entrance

SUPPLEMENT MANUAL IM250R03. AQUAVAR CPC SUPPLEMENT A - Variable Speed Drive SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167)

Air-Cooled Scroll Compressor Chillers Models AGZ 010A to AGZ 034A Models AGZ 026B to AGZ 130B. Revised Electrical Data Tables.

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

User Manual. Solar Charge Controller 3KW

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

MDT5N25 & MTD5N40 SERVICE PARTS

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

AUTO PUMP 12V MODEL #: V 12 VOLT DC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. INPUT: Volts DC, 11 Amps OUTPUT: 100 PSI Max

NME950 & FME1200 SERVICE PARTS

INSTALLATION INSTRUCTIONS DNLOWAMB015A00, DNLOWAMB016A00

Short-Circuit Current Ratings

VHIA High-Static Ducted Indoor Units - 60HZ

Installing and Removing Power Supplies

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

PCB COMMERCIAL SERIES

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

INSTALLATION INSTRUCTIONS

5300 Series Installation Guidelines

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

2 1/2 Ton Convertible Air Handler TAM7A0B30H21SD Standard Coil TAM7A0B30H21EA Black Epoxy Coil

Transcription:

SPECTRACOOL Slim Fit Air Conditioners (Surface-Mount Units Only) Quick Start Operation Guide Rev. D 2018 nvent PH 763 422 2211 nvent.com

NOTE: Refer to the instruction manual for all other installation and safety information HANDLING AND TESTING THE AIR CONDITIONER Inspect the air conditioner and verify correct functionality before mounting the air conditioner. CAUTION Do not attempt to operate the air conditioner while it is horizontal or on its side, back or front. The refrigeration compressor is filled with lubricating oil. This will cause permanent damage to the air conditioner and voids the warranty. If the air conditioner has been in a horizontal position, be certain it is placed in an upright, vertical or mounting position for a minimum of five (5) minutes before operating. ELECTRICAL INSTALLATION Refer to the nameplate for proper electrical current requirements, and then wire the unit to a properly grounded power supply using copper conductors only. Power supply wiring should be restrained after field installation to ensure no contact with internal fan. Minimum circuit ampacity should be at least 125% of the amperage, and +/- 10% of the voltage, shown on the unit nameplate. No other equipment should be connected to this circuit to prevent overloading. Use a higher ampere rated circuit breaker, or time-delay fuse, that is closest to the nominal ampere rating of the air conditioner, or sum of the individual component ampere ratings, to protect system electrical circuits from short circuit or overload. 1. Loosen the screw on the evaporator access panel and remove the power access panel, see Figure 1 2. Route the power supply wire through the strain relief. 3. Connect the wire to the terminal block per the label. 4. Reinstall the power access panel and screw. 5. Tighten the screw on the strain relief to secure the supply wire, see Figure 2. 6. For optional 3-phase operation, ensure the proper phase connection order by observing the phase monitor green light. Figure 1 Figure 2-2 - 2018 nvent PH 763 422 2211 nvent.com

Immediately after applying power, the evaporator blower (enclosure air) should start running. Operate the air conditioner with the compressor running for five (5) to ten (10) minutes. You will need to set the cooling controller set point below the ambient temperature to operate the compressor. Condenser air temperatures should be warmer than normal room temperatures within a few minutes after the condenser impeller(s) starts. If electrical power to the air conditioner is interrupted and reapplied, the compressor may take up to five (5) minutes to restart due to the high back pressure of the compressor. DOOR SWITCH The door switch terminal block on the back of the unit includes a jumper that is used only if the door switch option is not used. Several door switches may be connected in series and operated on one cooling unit. The door switch only supports a floating connection, no external voltages. Remove the jumper from terminals 3 and 4 of the connector, and connect the door switch to the two terminals if the door switch is available. SURFACE MOUNTING CAUTION Air conditioner must be in upright position during operation. 1. Using the mounting gasket kit provided with the unit, install gasket to the air conditioner, see Figure 3. 2. See Figure 5 or Figure 6 or Figure 7 or Figure 8 or Figure 9 for the enclosure cutout diagrams, depending on the unit being installed. 3. Screw the supplied grub screws into the blind nuts on the rear of the unit, see Figure 4. 4. Secure the unit using the supplied washers and nuts. 5. Mount the air conditioner to the enclosure being careful not to damage the mounting gasket. The mounting gasket is the seal between the air conditioner and the enclosure. Avoid dragging the air conditioner on the enclosure with the mounting gasket attached as this could cause rips or tears in the gasket. 6. Allow unit to remain upright for a minimum of five (5) minutes before starting. Figure 3 Figure 4 SMART CONTROLLER The controller is wired and programmed at the factory to be energized when power is applied to the air conditioner. Adjust the controller to the desired cabinet temperature. The factory default cooling differential for controllers that are set-up for C, or for F, are as follows: Cooling Set-point Turn-on Turn-off 35 C 35 C 30 C 80 F 87 F 80 F - 3-2018 nvent PH 763 422 2211 nvent.com

9.38 238 11.50 292 21.65 550 19.44 494 7.74 196.315 8 (4) 9.61 244 Figure 5 S06 300W SURFACE-MOUNT CUTOUT 8.00 203 10.50 267.50 13 21.65 550 7.40 188 12.05 306 7.56 192 20.94 532.315 8 (4) 10.32 262 Figure 6 S06 500W SURFACE-MOUNT CUTOUT - 4-2018 nvent PH 763 422 2211 nvent.com

10.00 254 14.00 356 37.44 951 11.50 292 10.04 255 10.75 273 14.14 359 12.19 310 15.16 385.375 10 (8) 9.84 250 (4) 15.75 400 Figure 7 S10 1000/1500W SURFACE-MOUNT CUTOUT 12.44 316 14.00 356 14.96 380 62.19 1580 25.63 651 21.65 550 9.44 240 12.19 310 12.80 325 21.83 554 10.82 275.375 10 (10) (5) 15.75 400 Figure 8 S16 2000/2500W SURFACE-MOUNT CUTOUT - 5-2018 nvent PH 763 422 2211 nvent.com

12.44 316 17.94 456 14.96 380 62.19 1580 27.30 693 19.68 500 6.46 164 16.13 410 14.77 375 19.66 499 10.82 275.375 10 (10) 14.96 380 (5) 19.69 500 Figure 9 S16 4000W SURFACE-MOUNT CUTOUT - 6-2018 nvent PH 763 422 2211 nvent.com