LEP ASSESSMENT REVIEW

Similar documents
ELECTRICAL SERVICE TECHNICIAN EXAMINATION 16 September 2017 QUESTION AND ANSWER BOOKLET

ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET

ELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 25 November 2017 QUESTION AND ANSWER BOOKLET

EST Electrical Service Technician Answer Schedule

ES5 Security Theory/Regulations Answer Schedule

ELECTRICIAN S THEORY EXAMINATION 11 September 2010 QUESTION AND ANSWER BOOKLET

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 22 November 2014 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 29 June 2013 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

ELECTRICIAN S THEORY EXAMINATION 19 June 2010 QUESTION AND ANSWER BOOKLET

ELECTRICIAN S THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

FINAL-ER 42 Electrician Regulations Answer Schedule

NZQA registered unit standard version 1 Page 1 of 5

ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

ES5. Candidate Code No. For Board Use Only. Result Date Int. Result Date Int

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011

ELECTRICIAN S THEORY EXAMINATION 20 June 2015 QUESTION AND ANSWER BOOKLET

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 3 NOVEMBER 2009

Initial and Periodic Inspection and Testing of Electrical Installations ( ) Sample Test

ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010

Electrical Awareness and Considerations

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

Fault Finding. Standard/Fundamental Faults

Class X Chapter 09 Electrical Power and Household circuits Physics

Electrical. Earthing & Bonding. Installation Techniques. Learning Notes MODULE 2.2 UNIT PHASE:2

Boardworks Ltd Mains Electricity

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 4 NOVEMBER 2009

Question 2: Around the bar magnet draw its magnetic fields. Answer:

TRANSMISSION SYSTEMS

MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33

Solar PV General Introduction Guide for Electricians

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

MAGNETIC EFFECTS OF ELECTRIC CURRENT. To understand Magnetic effects of Electric current, first we should know what is the Magnet?

Effective discrimination of protective devices

Wilkins Safety Group

Electrical Protection

Electrical Testing Company Pty Ltd / download at electricaltestingcompany.com.au / AS/NZS 3003:2011 Cardiac (Rev C)

Level 3 Award in the Requirements for Electrical Installations BS 7671:2018 ( )

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

Electrical Testing Company Pty Ltd / / AS/NZS 3003:2011 Body (Rev E)

Item L.1 Voltages 1. The consumer voltage must be between +10% and -10% of the nominal national voltage (nnv.)

Page 1 of 19. Website: Mobile:

Intext Exercise 1 Question 1: Why does a compass needle get deflected when brought near a bar magnet?

Underground Distribution Construction Manual

SAFETY FACT SHEETS. Electrical Hazards Safety Non Negotiable. G-HS-ST Electrical Hazards. G-HS-FS Version:1

Service Entrance Methods

Magnetic Effects of Electric Current

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

This page is purposely left blank

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

IT 28 ELECTRICAL INSPECTOR EXAMINATION ANSWER SCHEDULE. Question 1 Marks Reference Marking notes. (1 mark) ESR 57(3)(e)(ii)

LEAD ACID BATTERY CHARGER

Safety Lampholders and Pendants

LED Recessed Troffer Retrofit Kit

CHAPTER 13 MAGNETIC EFFECTS OF ELECTRIC CURRENT

EC400 Power Control System

KEWTECH. KT56 digital multi function tester. Instruction manual

Major changes within the New 18 th Edition Wiring Regulations announced by The IET

FACT SHEET Standard: Electrical Safety

reflect energy: the ability to do work

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Key elements of the AS3000 Wiring standards and some of the recent changes.

Earthing Principles. Symmetra PX 250/500 kw

BSS Examination Checking Procedures Part 3 - Electrical systems Recommendations for change May 2012

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Qualification UEE 30806/07 Cert III in Electrotechnology Electrician

PAPER 2 THEORY QUESTIONS

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

9. Effects of an electric current

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

1.Safe testing IMPORTANT:

DIGITAL RCD(ELCB) TESTER

SafetyPAT Plus A B P/N:

Electrical operating instructions

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 2 NOVEMBER 2009

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

FAQ s. Designing metering switchboards as per Victorian service installation rules

CHAPTER 2: ELECTRICAL SAFETY

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

INFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL

Ordinary Level Physics SOLUTIONS: EFFECTS OF AN ELECTRIC CURRENT

Product Data Sheet. Damper Interface. Features

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show.

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

User Manual Rittal PMC UPS 6kVA

INSP-3 Wiring Inspection Tester

Electrical test equipment for use on low voltage electrical systems

12 amp RMS Battery Charger

1. Why does a compass needle get deflected when brought near a bar magnet?

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010

Learning Module 10: Loadcenters. 101 Basic Series

Trade of Metal Fabrication. Module 1: Basic Fabrication Unit 15: Electricity Phase 2

Transcription:

LEP ASSESSMENT REVIEW FOR SURNAME: NAME: ASSESSMENT DATE:

Candidate: Assessor: Final Mark NOTE: Question 1 is a negative marking system. Start with 35 marks and marks are deducted from 35 if mistakes or omissions are made. Zero (0) mark is the minimum mark for question 1. Q1 Relates to Wiring of Meter Board, Switchboard and Distribution Board (35 marks) Type of Installations Incorrect installation wired Correct Installation Installed The type of supply installed does not match the Installation requested Maximum Demand Calc. Correct Maximum Demand Calculated Incorrect table used for MD calculation Incorrect FSC MD Incorrect Sub-Mains MD Incorrect Total MD Incorrect balance of MD across 3 phase Mains / Sub Mains Cable Size Mains / Sub Mains Cable Size Correct Consumer Mains over size Consumer Mains under size Sub - Mains over size Sub - Mains under size Incorrect standard/table/column used for cable selection Cable size units omitted or incorrect Main Earth Cable Size Main Earth Cable Size Correct Main Earth over size Main Earth under size Main Earth under recommended Min size (WR 5.3.3.2) Consumer Mains - Unmetered Underground Pit Underground Pit Labelled Correctly Address label not on the U/G cables Address does not include House/Lot No, Street, Suburb Mains Box Mains Box Connections Correct Consumers Mains Actives Not installed as per manufacturer instructions Consumers Mains Neutral Not installed as per manufacturer instructions

Meter Box Supply Fuses Supply Fuses Wired Correctly Installed with O/H Consumer Mains Incorrectly wired (must use top and bottom terminal of fuse) Phase sequence not as per SIR requirements Not installed with U/G Consumer Mains Meter wiring Meter Wiring Correct Line and Load actives not installed as per SIRs - Meter Panel wiring requirements Active conductor used as Meter neutral Meter neutral Not in accordance with SIR requirement (7.5.1.3) - (Minimum size - 4mm 2 ) Neutral link Neutral Link Wired Correctly Consumer mains incoming Neutral not connected under Clamp terminal Neutral Link not used Cable Tie Cable Tie Installed Correctly All hinged cables not under cable tie and tied to the Meter Panel Cable installed but too loose to stop cables from pulling through cable tie Address label Address label on Meter Panel Correctly Address does not include House/Lot No, Street, Suburb and spelt correctly Address label not provided on the Meter Panel as per SIRs Underground Details Underground Details Correct Underground cable plan & details not provided Underground cable plan & details not provided as per instructions or incomplete Switch Board / Distribution Board MEN Connection MEN Link Installed Correctly MEN not installed MEN under single screw on Neutral / Earth Bar MEN under two screws on Neutral/Earth bar but only one screw tightened MEN under size MEN in incorrect position on Neutral / Earth Bar and not labelled Main Earth installation Main Earth Installation Correct Not installed in a manner to be free from the likelihood of mechanical damage or becoming displaced, and secured to prevent stress on the termination (i.e. large loop at Earth Clip) No earth clip used / Earth clip not used in accord with manufactures instructions Main Earth install on Earth bar under single screw Main earth under two screws on Earth bar but only one screw tightened No Main Earth wire installed Earth Electrode location not identified at the Main Switchboard (wording must be Earth Electrode) "Do not disconnect" tag not installed as per the WR requirements Main Switch / Switches / O/L protection on Consumers Mains Main Switch / Switches / O/L protection on Consumers Mains Correct Main switch not provided

Main Switch incorrect rating No / incorrect over load protection of the Consumers Mains Main switch / Isolator switch labels Main Switch / Isolator Switch Labelled Correctly Not Provided Main Switchboard, Distribution Board MCB labelled as Isolator / Main Switch FSC Loads labelled as Main Switches Distribution board isolator labelled as Main Switch General Switchboard / Distribution Board labelling General Switchboard / Distribution Board labelling Correct FSC labelling not provided Incorrect Labelling of circuits provided (i.e Range labelled as HWS) Switchboard wiring / F.S.C. cables & connections Switchboard Wiring / F.S.C. Cables & Connections Correct No FSC neutrals wired No FSC earths wired Incorrect Neutral sequencing Incorrect wiring of the protected neutral bar Daisy chaining undersize cable across RCDs - MCBs Incorrect colour of FSC earths / Neutrals Incorrect table used for cable selection Incorrect cable size for FSC / Switchboard wiring RCD/s not wired to operate - Incorrectly wired MEN situation created at Distribution Switchboard All connections / screws done up to at least finger tight Other faults identified by assessor Details:... Final Sub Circuits protection Final Sub Circuits Protection Correct No Overload protection of the FSC Incorrect FSC overload protection Access to live parts No Access To Live Parts Escutcheon Plate missing / Distribution Board cover not securely closed Pole fillers missing adjacent to live conductors / components Neutral link cover not installed securely Meter Panel not securely closed Service fuse wedge/s not inserted 3 phase load cover not installed securely FOLCB cover not securely fixed in place Incorrect selection of components Selection of Components Correct Incorrect RCD type selected Details... General Extra components / circuit supplied and / or omitted Components / Circuits Supplied Correctly Distribution board isolator not provided

Extra circuit provided that was not ask for Using an RCD/MCB combo PLUS MCBs Circuits Omitted Unsafe defect not listed above Details... Total marks LOST for question 1 Total marks awarded for question 1 Q2 Relates to Testing an Installation (32 marks) Q2.1 Resistance of the Main Earthing Conductor and Bonding Conductors (2 marks) Main Earthing Conductor (1 mark) Main Earth conductor - Correct Reading and result Main Earth conductor - Correct Reading with result incorrect Main Earth conductor - Correct Reading with no or incorrect units Main Earth Conductor - Incorrect reading Main Earth conductor - Not attempted Bonding Conductor to water pipe (1 mark) Bonding conductor - Correct Reading and result Bonding conductor - Correct Reading with result incorrect Bonding conductor - Correct Reading with no or incorrect units Bonding Conductor - Incorrect reading Bonding conductor - Not attempted Q2.2 Insulation Resistance of Wiring (10 marks) Whole Installation (2 marks) Whole Installation - Correct Reading and Result Whole Installation - Correct Reading with result incorrect or not given. Whole Installation - Correct Reading with no or incorrect units Whole Installation - Incorrect reading Whole Installation - Not attempted Subcircuit No.1 (2 marks) Subcircuit No.1 - Correct Reading and Result Subcircuit No.1 - Correct Reading with result incorrect or not given. Subcircuit No.1 - Correct Reading with no or incorrect units Subcircuit No.1 - Incorrect reading Subcircuit No.1 - Not attempted Subcircuit No.2 (2 marks) Subcircuit No.2 - Correct Reading and Result

Subcircuit No.2 - Correct Reading with result incorrect or or not given. Subcircuit No.2 - Correct Reading with no or incorrect units Subcircuit No.2 - Incorrect reading Subcircuit No.2 - Not attempted Subcircuit No.3 (2 marks) Subcircuit No.3 - Correct Reading and Result Subcircuit No.3 - Correct Reading with result incorrect or not given. Subcircuit No.3 - Correct Reading with no or incorrect units Subcircuit No.3 - Incorrect reading Subcircuit No.3 - Not attempted Subcircuit No.4 (2 marks) Subcircuit No.4 - Correct Reading and Result Subcircuit No.4 - Correct Reading with result incorrect or not given. Subcircuit No.4 - Correct Reading with no or incorrect units Subcircuit No.4 - Incorrect reading Subcircuit No.4 - Not attempted Q2.3 Earthing & Insulation Resistance of Appliance (3 marks) Earthing of the appliance (1 marks) Earthing of Exposed Metal - Correct Reading and Result Earthing of Exposed Metal - Correct Reading with result incorrect Earthing of Exposed Metal - Correct Reading with no or incorrect units Earthing of Exposed Metal - Incorrect reading Earthing of Exposed Metal - Not attempted Insulation Resistance of Appliance (2 marks) Insulation Resistance - Correct Reading and Result Insulation Resistance - Correct Reading with result incorrect Insulation Resistance - Correct Reading with no or incorrect units Insulation Resistance - Incorrect reading Insulation Resistance - Not attempted Q2.4 Resistance of Protective Earthing Conductors (4 marks) Socket Outlet No.1 (1 mark) Socket Outlet No. 1 - Correct Reading and Result Socket Outlet No. 1 - Correct Reading with result incorrect Socket Outlet No. 1 - Correct Reading with no or incorrect units with the correct result. Socket Outlet No. 1 - Incorrect reading Socket Outlet No. 1 - Not attempted Socket Outlet No. 2 (1 mark) Socket Outlet No. 2 - Correct Reading and Result

Socket Outlet No. 2 - Correct Reading with result incorrect Socket Outlet No. 2 - Correct Reading with no or incorrect units with the correct result. Socket Outlet No. 2 - Incorrect reading Socket Outlet No. 2 - Not attempted Fluorescent Luminaire (1 mark) Fluorescent Luminaire - Correct Reading and Result Fluorescent Luminaire - Correct Reading with result incorrect Fluorescent Luminaire - Correct Reading with no or incorrect units with the correct result. Fluorescent Luminaire - Incorrect reading Fluorescent Luminaire - Not attempted Appliance Socket Outlet (1 mark) Appliance Socket Outlet - Correct Reading and Result Appliance Socket Outlet - Correct Reading with result incorrect Appliance Socket Outlet - Correct Reading with no or incorrect units with the correct result. Appliance Socket Outlet - Incorrect reading Appliance Socket Outlet - Not attempted Q2.5 Polarity Test - Consumers Mains (2 marks) Consumers Mains ACTIVE (1 mark) Active - Correct Reading and Result Active - Correct Reading with result incorrect Active - Correct Reading with no or incorrect units Active - Incorrect reading Active - Not attempted Consumers Mains Neutral (1 mark) Neutral - Correct Reading and Result Neutral - Correct Reading with result incorrect Neutral - Correct Reading with no or incorrect units Neutral - Incorrect reading Neutral - Not attempted Q2.6 Polarity Test - Operation of Switches (5 marks) Ceiling Rose (1 mark) Ceiling Rose - Correct response given with the correct result. Ceiling Rose - Correct response given with an incorrect result Ceiling Rose - Incorrect response given. Ceiling Rose - Not attempted Fluorescent Luminaire (1 mark) Fluorescent Luminaire - Correct response given with the correct result. Fluorescent Luminaire - Correct response given with an incorrect result Fluorescent Luminaire - Incorrect response given. Fluorescent Luminaire - Not attempted

Socket Outlet No. 1 (1 marks) Socket Outlet No. 1 - Correct response given with the correct result. Socket Outlet No. 1 - Correct response given with an incorrect result Socket Outlet No. 1 - Incorrect response given. Socket Outlet No. 1 - Not attempted Socket Outlet No. 2 (1 mark) Socket Outlet No. 2 - Correct response given with the correct result. Socket Outlet No. 2 - Correct response given with an incorrect result. Socket Outlet No. 2 - Incorrect response given. Socket Outlet No. 2 - Not attempted Socket Outlet FAN (1 mark) Socket Outlet Fan - Correct response given with the correct result. Socket Outlet Fan - Correct response given with an incorrect result Socket Outlet Fan - Incorrect response given. Socket Outlet Fan - Not attempted. Q2.7 Fault Loop Impedance (2 marks) Appliance socket outlet Appliance Socket Outlet - All parts correct Appliance Socket Outlet - Correct Measured and T 8.2 values with incorrect result. Appliance Socket Outlet - Correct Measured value with incorrect T 8.2 value therefore incorrect result. Appliance Socket Outlet - Incorrect Measured Value Appliance Socket Outlet - Incorrect Protective device rating. Appliance Socket Outlet - Values have no or incorrect units given. Appliance Socket Outlet - Not attempted Q2.8 RCD Testing (4 marks) RCD 1 reading correct - time / trip current RCD 1 reading incorrect - time / trip current RCD 2 reading correct - time / trip current RCD 2 reading incorrect - time / trip current RCD 3 reading correct - time / trip current RCD 3 reading incorrect - time / trip current Wiring rule correct Wiring rule incorrect

Q3 MEN System Voltage Measurements 3.1 Measured Values (8 marks) All parts correct No supply voltage measured or incorrect Test Condition 1 All readings correct Test Condition 1 All readings incorrect Test Condition 1 Appliance Frame reading correct Test Condition 1 Appliance Frame reading incorrect Test Condition 1 Appliance terminal reading correct Test Condition 1 Appliance terminal reading incorrect Test Condition 1 Water Pipe reading correct Test Condition 1 Water Pipe reading incorrect Test Condition 2 All readings correct Test Condition 2 All readings incorrect Test Condition 2 Appliance Frame reading correct Test Condition 2 Appliance Frame reading incorrect Test Condition 2 Appliance terminal reading correct Test Condition 2 Appliance terminal reading incorrect Test Condition 2 Water Pipe reading correct Test Condition 2 Water Pipe reading incorrect Test Condition 3 All readings correct Test Condition 3 All readings incorrect Test Condition 3 Appliance Frame reading correct Test Condition 3 Appliance Frame reading incorrect Test Condition 3 Appliance terminal reading correct Test Condition 3 Appliance terminal reading incorrect Test Condition 3 Water Pipe reading correct Test Condition 3 Water Pipe reading incorrect Test Condition 4 All readings correct Test Condition 4 All readings incorrect Test Condition 4 Appliance Frame reading correct Test Condition 4 Appliance Frame reading incorrect Test Condition 4 Appliance terminal reading correct Test Condition 4 Appliance terminal reading incorrect Test Condition 4 Water Pipe reading correct Test Condition 4 Water Pipe reading incorrect All the APPLIANCE FRAME readings incorrect All the WATER PIPE readings incorrect All the APPLIANCE TERMINAL readings incorrect No units or incorrect units given 3.2 MEN explanation (10 marks) Your explanation of the Voltage readings covers all aspects of the question No mention of what the fault could be and where the fault occurs? No explanation of the MEN system. Your explanation does not fully explain your voltage readings. In your explanation you write that voltage flows in the circuit instead of current flow.

Current flow diagram not completed or incorrect No explanation of the safety of the installation Other Q4 Visual Defects (15 marks) Defect 1 (3 marks) Correct defect and Wiring Rules Clause No. Correct defect with Wiring Rules Clause/Table Number incorrect or not provided Correct defect with Wiring Rules Clause/Table Number incomplete Incorrect defect with correct Wiring Rules Clause/Table Number Incorrect defect with incorrect Wiring Rules Clause/Table Number Defect 2 (3 marks) Correct defect and Wiring Rules Clause No. Correct defect with Wiring Rules Clause/Table Number incorrect or not provided Correct defect with Wiring Rules Clause/Table Number incomplete Incorrect defect with correct Wiring Rules Clause/Table Number Incorrect defect with incorrect Wiring Rules Clause/Table Number Defect 3 (3 marks) Correct defect and Wiring Rules Clause No. Correct defect with Wiring Rules Clause/Table Number incorrect or not provided Correct defect with Wiring Rules Clause/Table Number incomplete Incorrect defect with correct Wiring Rules Clause/Table Number Incorrect defect with incorrect Wiring Rules Clause/Table Number Defect 4 (3 marks) Correct defect and Wiring Rules Clause No. Correct defect with Wiring Rules Clause/Table Number incorrect or not provided Correct defect with Wiring Rules Clause/Table Number incomplete Incorrect defect with correct Wiring Rules Clause/Table Number Incorrect defect with incorrect Wiring Rules Clause/Table Number Defect 5 (3 marks) Correct defect and Wiring Rules Clause No. Correct defect with Wiring Rules Clause/Table Number incorrect or not provided Correct defect with Wiring Rules Clause/Table Number incomplete Incorrect defect with correct Wiring Rules Clause/Table Number Incorrect defect with incorrect Wiring Rules Clause/Table Number