Kitchen Tech Series Air Curtain

Similar documents
Air Curtain. Installation, Operating and Maintenance Instructions

Raydot LLC 24 Actuator (115 VOLT)

Installation Manual DIAPHRAGM WELL TANK

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Model FM2642 Wall Mount. Full Motion Television Wall Mount

StormPro BA Series Sump Pump

SPC-PANEL Simplex, Single Phase Pump Control Panel

Owner s Manual GLASSLINED PUMP TANK

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

FADE Series Wall Axial Fans

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Extension Hopper Installation & Operator s Instruction Manual for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

ESE Series Cast Iron Sewage Pumps

Installation manual. 2 front / 1 rear spacer kit Jeep Wrangler JK 2 & 4 door Part # 42005

StormPro BCV400 Sewage Ejector Pump

Effective June 1, 2013 This guide supersedes all previous versions

Owner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

HP190SL Series Slimline Radon Fans

1000-LB. ENGINE STAND

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

1000-LB. MOTORCYCLE LIFT TABLE OWNER S MANUAL

Model C230 Pump Controller

2SHE Series Direct-Drive Shutter Fans

Installation manual. 1.5 front leveling kit. Nissan Titan. Part # Part # Important customer information: Nissan Titan

2000-LB. ENGINE STAND

Installation manual. Replacement front sway bar end link Dodge Ram Dodge Ram 1500 Part # 30927

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Heavy Duty Four Wheeled Walker

RED23305 Owner s Manual

Pump Installation and Service Manual HRS Hydromatic Retractable System

Model FM2260 Wall Mount. Full Motion Television Wall Mount

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual

Installation Instructions Receiver Rack (Part # 7700) Universal Application

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Installation manual. Front leveling kit. Part # Part # Important customer information: Ram WD Ram WD

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Operating and Installation Instructions

Model 90 Twin Control Unit

Instructions for Tradewind. Please read before use. Model # Serial # Form # ADM Stowe Dr., Poway, Ca

Prime Attachments & Custom Fab Brush Mower Owners/Operators Manual

Installation manual. Rear traction bars. Ram Ram Part # Part # Important customer information:

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

PUSH BUTTON KEY CABINET

Tiller Lock Assembly

Installation Instructions

Sawhorse with Chainsaw Holder

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

Premium Supply. Direct Push. Models PCK-3530-DP PCK DP PCK-530-DP. Operator s Manual and Installation Instructions

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

6-TON DOUBLE LOCKING JACK STANDS OWNER S MANUAL

IMPORTANT! 09 to Current Straight Up Electric Billet Center Stand. Dealer and/or Customer must complete the following items: Center Stand Checklist

Installation manual 2 Leveling kit GM x 4. Part # Part # Important customer information: GM x 4

Installation manual. Long arm upgrade kit of lift March 1999 Dodge Ram 1500, 2500 and Part # 30945

Part No DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345

ASSEMBLY / OPERATION INSTRUCTIONS. Low Profile Motorcycle Dolly

Installation Manual. Uniball Upper Control Arm Kit Toyota Tacoma 4x Toyota 4Runner 4x Toyota Tundra 4x4 Part # 50965

Installation manual. Toyota Tundra 4WD & 2WD. 2.5 Suspension kit. Part # Part # Important customer information:

Installation manual. Rear ladder bars. Chevy/GMC 2500/3500 HD. Part # Part # Important customer information:

CAMBELT TENSION GAUGE

Adjustable Steel Welding Table

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

DISC BRAKE CALIPER TOOL SET

BMRX Series ROTARY LEVEL CONTROL

Installation and Operation Instructions Safety Director Arrow

TONS. Before each shift: Before operating: Before initial operation of hoist:

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

25 GALLON PORTABLE OIL LIFT

16 Inch Hanging Pendant Barn Light

Installation manual. 2 Suspension System. Ford F150 4WD and 2WD. Part # Part # Ford F150 4WD and 2WD

User s Manual and Operating Instructions

Cincinnati, OH USA

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

GARDEN HOSE UTILITY PUMP

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

HA/HAB Fiberglass Wall Mount Ventilators

LIFT NAME PART NUMBER SETBACK (min) SETBACK (max)

Installation Manual 2019 Ram wd. 2 front leveling kit. Part # Part # Ram wd (will not fit Air ride models)

Heavy-Duty Drywall Dolly Cart

MANUAL NO CREATED: 08/08/2012 MMH REV A STEEL COMPANY R 65 BUSHEL MINI-BIN PARTS AND ASSEMBLY MANUAL

3-TON DOUBLE LOCKING JACK STANDS OWNER S MANUAL

2019-ON RAM 1500 INSTALLATION INSTRUCTIONS

Installation Precautions. Use Precautions. Specifications

Heavy-Duty Welding Fabrication Table

Electric Chainsaw Sharpener With Bar Mount

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

RAM 1500, 2019 CLASSIC & 2010-ON 2500/3500 INSTALLATION INSTRUCTIONS

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

50 Ft. Retractable Cord Reel

ATV Log Arch and Holder

Owner s Manual Drill and Light Weight Portable Utility Pumps

Installation Power Management Unit Battery Cables and Battery Harness

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Transcription:

Installation, Operating, and Maintenance Instructions Save this manual for future reference. Kitchen Tech Series Air Curtain Model Numbers: KTECH026, KTECH036, KTECH042, KTECH048, KTECH060, KTECH072, KTECH084, KTECH096, KTECH108, KTECH120, KTECH144, READ THIS OWNER S MANUAL CAREFULLY BEFORE YOU INSTALL YOUR NEW WILLIAMS AIR CURTAIN. Door/window widths from 26 to 144 inches Heavy-gauge, galvanized steel construction Voltages 120V, 208V, 240V Adjustable aluminum directional vanes WARNING: Altering the product or replacing parts with unauthorized factory parts will void all warranties and may result in improper operation and/or a hazardous safety condition to service personnel or occupants. Mounting plate provided for easy installation Contents Your Warranty...2 Installation Record...2 Safety Rules...3 Introduction...4 Installing Your Air Curtain... 5-6 Operating Your Air Curtain...7 How to Care for Your Air Curtain..........7 Replacement Parts........8 Service Record......... 9 Williams continues to improve its products and as a result, the design and specifications of each product may be changed without notice. Installation and service must be performed by a qualified installer or service agency. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or for additional information consult a qualified installer or service agency. Williams 250 West Laurel Street Colton, California 92324 USA

Your Warranty The manufacturer, Williams, warrants this air curtain to the original purchaser under the following conditions: LIMITED FIVE-YEAR WARRANTY 1. Any part thereof which proves to be defective in material or workmanship within five years from date of original purchase for use will be replaced at the Manufacturer s option, FOB to its factory. 2. No liability is assumed by the Manufacturer for removal or installation labor costs, nor for freight or delivery charges. LIMITATIONS 1. THIS LIMITED WARRANTY IS THE ONLY WARRANTY MADE BY THE MANUFACTURER, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE ARE LIMITED TO THE SAME FIVE YEAR TERM AS THE EXPRESS WARRANTY. UNDER NO CIRCUMSTANCES SHALL THE MANUFACTURER BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, SPECIAL OR CONTINGENT DAMAGES OR EXPENSES ARISING DIRECTLY OR INDIRECTL Y FROM ANY DEFECT IN THE PRODUCT OR ANY COMPONENT OR FROM THE USE THEREOF. THE REMEDIES SET FORTH HEREIN ARE THE EXCLUSIVE REMEDIES AVAILABLE TO THE USER AND ARE IN LIEU OF ALL OTHER REMEDIES. Some states do not allow limitation on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. 2. This warranty does not include any charge for labor or installation. 3. This warranty does not extend to painted surfaces or to damage or defects resulting from accident, alteration, misuses or abuse or improper installation. 4. This warranty does not cover claims which do not involve defective workmanship or materials. DUTIES OF THE ENDUSER 1. The equipment must be installed by a qualified installer and operated in accordance with the installation instructions furnished with the equipment. 2. Any travel, diagnostic costs, service labor, and labor to repair the defective unit will be the responsibility of the owner. 3. A bill of sale, cancelled check, payment record or permit should be kept to verify purchase date to establish the warranty period. 4. Have the installer enter the requested information in the space below. GENERAL 1. The manufacturer neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with said equipment. 2. Service under this warranty should be obtained by contacting your dealer. Provide the dealer with the model number, serial number, and purchase date verification. 3. If, within a reasonable time after contacting your dealer, satisfactory service has not been received, contact: Customer Service Department, 250 West Laurel Street, Colton, CA 92324 for assistance. 4. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. Installation Record Model No. Serial No. Original Purchaser Address City and State Zip Dealer Address City and State Zip Installation Date Name Signature (Dealer or authorized representative who certifies that this appliance is installed in accordance with Manufacturer s instructions and local codes.) 2

Stay Safe WARNING: Read these rules and the instructions carefully. Failure to follow these rules and instructions could cause a malfunction of the air curtain. This could result in death, serious bodily injury and/or property damage. INSTALLATION MUST CONFORM TO LOCAL CODES. COMPLIANCE WITH ALL CODES IS THE RESPONSIBILITY OF THE INSTALLER. 1. The important safety instructions, warnings and cautions in these pages are not meant to cover all possible problems or conditions. Use common sense and caution when installing, maintaining or operating the equipment. Always contact Williams about any problems or conditions that you do not understand. 2. Use only manufacturer s replacement parts. Use of any other parts could cause injury or death. 3. It is the sole responsibility of the customer to provide the necessary protection to prevent vandalism and weather protection of the equipment. Under no circumstance should the air curtain be left exposed to the elements. Protect the units from dirt, plaster and other debris during the entire construction phase. Prior to start-up, the entire interior of the unit should be inspected for debris and dirt. Clean, if necessary. Any failure of the unit or damage to the building as a result of improperly protecting and cleaning the unit is not covered by the warranty. 8. Any access panels, guards or parts removed for servicing must be replaced prior to operating to avoid property damage, bodily injury or death. 9. Always use good safety practices regarding the handling, installation and servicing mechanical equipment. 10. When the air curtain is operating, some components operate at high speeds. Personal injury can result in touching these items. 11. Take caution that no internal damage will result if screws or holes are drilled into the cabinet. 12. Always use proper eye protection, safety equipment and tools equipment during the installation. 13. No wiring or other work should be performed without verifying that the fan coil is completely disconnected from the power source and locked out. 4. Units weigh 25 to 75 pounds. A minimum of two people are recommended for handling and installation. 5. The equipment must be properly supported. Supports must always be adequate to hold the equipment securely. 6. All power must be disconnected before any installation or service is performed. More than one power source may be supplied to the air curtain. 7. Protect adjacent flammable material when welding or soldering. Use a heat shield to protect against sparks and solder. 3

Introduction The following steps are all needed for proper installation and safe operation of your air curtain. If you have any doubts as to any requirements, check with local authorities. Obtain professional help where needed. All of the checks and adjustments in the Start-Up Procedures are vital to the proper and safe operation of the air curtain. Please read the instructions before you install and use your air curtain. This will help you obtain its full value. It could also help you avoid needless service costs if the answer to the problem is found within this instruction manual. Always consult your local HVAC inspector or building department regarding regulations codes or ordinances which apply to the installation. Check the air curtain nameplate prior to installation. It is the responsibility of the installing contractor to inspect and verify that the unit received is the correct model number, voltage, etc. Any discrepancies should be resolved before uncrating and/or installation. Williams is not responsible for any back charges due to an incorrect unit being installed. Upon delivery, examine each unit and all parts carefully for shipping damage. Immediately report any freight damage to the freight carrier and file a freight claim with the carrier. All units are shipped FOB factory; therefore Williams is not responsible for damage during transit. Returns require written authorization from Williams. Unauthorized returns will be refused. All material returned will be inspected. Any damage, missing parts, rework or repackaging resulting from prior installation, abuses or neglect will constitute just cause for Williams to issue partial or no credit. Helpful Installation Information The following material will help you in making the installation: National Electrical Code ANSI/NFPA No. 70 or, in Canada, C.S.A. StandardC22.1 Unpacking Your Air Curtain Upon delivery, examine each unit and all parts carefully for shipping damage. Immediately report any freight damage to the freight carrier and file a freight claim with the carrier. All units are shipped FOB factory, therefore Williams is not responsible for damage occurring transit. It is the responsibility of the installing contractor to inspect and verify that the unit received is the correct model number, voltage, etc. Any discrepancies should be resolved before uncrating and /or installation. Williams is not responsible for any back charges due to an incorrect unit being installed. Returns require written authorization from Williams. Unauthorized returns will be refused. All Material returned will be inspected. Any damage, missing parts, rework or repackaging resulting from prior installation, abuses or neglect will constitute just cause for Williams to issue partial or no credit. REMOVE PACKING MATERIAL. Be sure to remove cardboard inserts from around blower wheels. 4

Installing Your Air Curtain The following steps are needed for proper installation and safe operation of your air curtain. Installation must adhere to all local and national code requirements. If you have any doubts as to any requirements, obtain professional help. Remember to ALWAYS consult your local HVAC inspector or building department regarding regulations, codes, or ordinances which apply to the installation. This unit must be installed in a manner which will allow the blower panel to be removed in order to clean the blower and motor and to provide access to electrical connections. It is the sole responsibility of the customer to provide the necessary protection to prevent vandalism and weather protection of the equipment. Protect the units from dirt, plaster and other debris during the entire installation phase. Prior to start-up, the entire interior of the unit should be inspected for debris and dirt. Clean, if necessary. Any failure of the unit or damage to the building as a result of improperly protecting and cleaning the unit is not covered by the warranty. Mounting Units weigh 25 to 75 pounds. A minimum of two people are recommended for handling and installation. Determine the location above the opening to where the air curtain is to be installed. It should be centered in the opening and as close to the top of the opening as possible. Make sure there are no obstructions that will interfere with the discharge of air curtain. The wall mounting plate must be level and be securely mounted to the structure with sufficient load-carrying capacity to support the weight of the equipment. All anchors for mounting must be placed and sized to ensure a safe installation. Mounting hardware is not included. Slide the top of the air curtain down to engage the top of the wall plate, then pivot the front down to the bottom of the plate. Using the screws provided, attach the unit to the wall plate through the holes along the bottom edge of the plate. Ensure that there are no gaps between the unit and wall. Hanging mount - there are four threaded openings on top of the unit for suspending the unit from the ceiling, if desired. For NSF Installations: The installation height is 7 feet. Make sure there no obstructions that will interfere with the air curtain. Ensure that there are no gaps between the unit and the wall. Hanging mount option Have pan head screws installed in the four threaded openings on top of the unit. These must be removed before installation in the hanging mount position (suspension rods from the ceiling). Electrical No wiring or other work should be performed without verifying that the air curtain is completely disconnected from the power source and locked out. Verify a good ground connection exists prior to energizing the power source. All wiring must comply with local and national code requirements. Williams air curtains are provided with a wiring diagram and nameplate data to provide the necessary information needed for field wiring. Wiring used for connections to the air curtain must be rated for at least 90 centigrade. All wiring connections must be tight. For outdoor wiring, motor wiring must go thru rainproof conduit and fittings to a rainproof electrical junction box located above the unit with no more than 2 feet of conduit run so that the motor wires may reach the junction box without having splices. Do not make wire splices inside the air curtain cabinet when it is being installed outdoors. The motor must be properly wired prior to start up. The warranty on all motors is void if the motor is burned-out due to incorrect wiring. Check the rating of the unit to determine: voltage, frequency, phase, amperage, appropriate switching, maximum over current protection (MOP) and full load amps (FLA). Any optional items, such as fan switches to be field installed must be wired in accordance with the wiring diagram supplied with the unit and the switch manufacturer s directions. See page 6 Figures 2 and 3. Adjusting Air Foil Deflector The air foils have 40 of adjustment. The majority (approximately 85%) of the air flow should be directed to the outside. See figure 1. To adjust the air foils loosen the screws securing the air foil bracket. Adjust the air foils to the angle desired and retighten the screws. 5

Installing Your Air Curtain FIGURE 1 FIGURE 2 Single Speed (NSF) FIGURE 3 - Variable Speed

Operating Your Air Curtain Start-Up Procedure Blower Wheel: With the power off, be sure that the blower wheel(s) rotate freely and quietly. To avoid imbalance or vibration, make sure the blower has been cleaned from any installation debris. Housekeeping: To ensure the best performance, be sure the equipment is clean of any debris collected during installation. Access Panels/Filters: All access panels and filters must be in place before operation. Caring for Your Air Curtain How to Care for Your Air Curtain WARNING RISK OF ELECTRICAL SHOCK CAN CAUSE INJURY OR DEATH. Disconnect all remote electric power supplies before servicing. Closing the door or window should not be used for disconnect purposes. To attain maximum performance, a formal schedule of maintenance should be performed. See page 9. Motor and Blower: At a minimum, the motor and blower should be cleaned annually. More frequently if installed in a dirty/greasy environment. Filter (optional): The filter should be changed every three months, or more often as required. CAUTION This unit must be installed in a manner that allows it to operate according to the nameplate data and comply with all applicable codes. Williams will assume no liability for damage to the unit or building due to misapplication, including field installed control devices not furnished or specified by Williams. 7

Replacement Parts Models: KTECH026, KTECH036, KTECH042, KTECH048, KTECH060, KTECH072, KTECH084, KTECH096, KTECH108, KTECH120, KTECH144 26-48 60-72 ITEM NO. DESCRIPTION QTY. 1 CAB SUB-ASY 1 2 SPRT BRKT MOT MT 1 3 MOTOR 1 4 WHL TANGENTIAL 1 5 WHL TANGENTIAL 1 6 CLMP MTR MNT 2 7 PNL COV 1 8 SPRT BRKT WALL MNT 1 9 JB COV 1 10 HEX INSERT.275 X.465 14 11 P626354 8 12 P138200 2 13 SCR 2 14 ES ASY BLD AIR FOIL 1 ITEM NO. DESCRIPTION QTY. 1 CAB SUB-ASY 1 2 SPRT BRKT MOT MT 1 3 MOTOR 1 4 WHL TANGENTIAL 1 5 WHL TANGENTIAL 1 6 CLMP MTR MNT 2 7 PNL COV 1 8 SPRT BRKT WALL MNT 1 9 JB COV 1 10 HEX INSERT.275 X.465 14 11 P626354 6 12 P138200 2 13 SCR 2 14 ASY BLD AIR FOIL 2

Replacement Service Record Parts Model No. Serial No. Model Description _ Installation Date Filter Part No. Voltage Amps Date Service Performed Parts Required Service Company Signature 250 West Laurel Street, Colton, CA 92324 (909) 825-0993 FAX: (909) 824-8009 e-wfc-fc.com All Rights Reserved D107748, 05/25/16