Accord DS/DM Series UltraSwitch Switch box

Similar documents
Automax DS/DM Series UltraSwitch Switch box

Accord DS/DM Series UltraSwitch Switch box

Accord WS/WM Series UltraSwitch

PMV WS/WM Series UltraSwitch

PMV WS/WM Series UltraSwitch

USER INSTRUCTIONS. Automax WS/WM Ultraswitch Switchbox. Installation Operation Maintenance FCD AXENIM /16

flowserve.com Flowserve Solenoid Valves Namur, Remote and Banjo Mounted Designs for Precision Control

D30 Compact Digital Positioner

USER INSTRUCTIONS. Accord PS/PM Ultraswitch Switchbox. Installation Operation Maintenance FCD ACENIM /14

Product Specification

Product Specification

Installation Operation Maintenance

Installation Operation Maintenance

PMV. P5 Pneumatic Positioner. Product Information

USER INSTRUCTIONS. PMV PS/PM Ultraswitch Switchbox. Installation Operation Maintenance FCD PMENIM /13

Product Specification

USER INSTRUCTIONS. Automax XCL/XML UltraSwitch. Installation Operation Maintenance. Switchbox. Experience In Motion FCD AXENIM A4-09/16

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

Logix 3800 Digital Positioner

Installation Operation Maintenance

Logix 3800 Digital Positioner

ACCORD Controls ARG Series Heavy Duty Actuator

Valve Position Monitors

WORCESTER CONTROLS F519/529/819/829. Full Bore Fire Safe Flanged Ball Valves

flowserve.com Limitorque LRP Limitorque Rack & Pinion Pneumatic Actuator

Installation Operation Maintenance

Kämmer Series Low Flow Valves

CRANE Limit Switches. CCR Series. CXA Series. CCA Series

Limitorque Actuation Systems PT Series Worm Gear Operator

Kämmer Series Low Flow Valve

flowserve.com Durco PlugSeal Valve ASME Class 600 Plug Valves Serving the Worldwide Desalination Industry Experience In Motion

Valve Position Monitors

Kämmer Series Split Body Valves

Mounting: The following instructions apply to rotary actuators only. Linear applications require special mounting and coupling (consult factory).

Limitorque Accutronic MX/WTR Performance and Dimensions. Limitorque Actuation Systems

TECHNICAL BULLETIN. NAF Trunnball DL Ball Valves. Experience in Motion FCD NFENTB A4 09/14

Limitorque. HBC Series Worm gear operators proven in the most demanding situations

Limitorque Actuation Systems B320 Series. Rugged and dependable bevel gear operators for manual or motorized valve control applications

SERIES 5A AND 5B VALVE STATUS MONITOR THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

TECHNICAL BULLETIN. NAF Setball SF Ball Sector Valves. Experience In Motion. flowserve.com. NAF Setball FCD NFENTB A4 02/16

Vogt Valves The Connection Bulletin for Y Pattern Globe & Check Valves Class 1690 & Class 2680 CB 18

Desuperheater FCD VLENTB /11. Experience In Motion

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /13

TECHNICAL BULLETIN. Logix 505si Series Digital Positioner. Experience In Motion FCD LGENTB /13

Automax SuperNova Series. Pneumatic Rack & Pinion Actuators

TECHNICAL BULLETIN. NAF Duball DL Ball Valves. Experience in Motion FCD NFENTB A4 12/14

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

SERIES 5A AND 5B VALVE STATUS MONITOR THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

Kämmer Multi-Z Severe Service Valves

flowserve.com Kämmer Multi-Z Kämmer Multi-Z Severe Service Valves

Quartz. Save Space with Low Profile Design

General purpose / hazardous area

NAF Duball DL Pocket Ball Valves TECHNICAL BULLETIN FCD NFENTB A4 11/17

Vogt Valves The Connection Bulletin for Forged Steel Globe Valves for Water-Free Chlorine Service Class 300, 600 & 800 CB 07

Limitorque HBC Series Worm Gear Operators

MARPAC K SERIES. Full Bore Fire Safe Flanged Ball Valves

USER INSTRUCTIONS. Valtek Control Products Spring Cylinder Linear Actuators. Installation Operation Maintenance. Experience In Motion

CONTROLS INC. Position Indicators. Valve Positioners

Sensor boxes SRBE Key features and product range overview

Product cataloge 2017

Solenoid Block Kit for Series 90 Modular Accessory System Installation, Operation and Maintenance Instructions

Limit Switch Type 4747

AccuTrak Rotary Position Monitors

USER INSTRUCTIONS. Limitorque TM V Series. Installation Operation Maintenance. Experience In Motion FCD LMENIM AQ 02/15

ACCUTRAK ROTARY POSITION MONITORS FLAMEPROOF - ATEX/IEC

Explosionproof NEC. Fully integrated and encapsulated rotary valve position monitors that are certified for use in explosive atmospheres.

Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions

TECHNICAL BULLETIN. Logix 520MD Series Digital Positioner. Experience In Motion FCD LGENTB /09

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

Worcester Controls Directional Ball Valves

Rotary Switches & Positioners

Know-how makes the difference. Limit Switches

Plug Valve Solutions for the Upstream Exploration and Production Pipelines Production manifolds, test manifolds and other dirty services

LIMIT SWITCH BOX MODEL - APL

Edward. Equiwedge Forged Gate Valvee. Experience In Motion

Integrated Control modules

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

TECHNICAL BULLETIN. Audco Ball Valve. Reduced Bore Fire safe Flanged Ball Valves 51/52 Series. Experience In Motion

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16

Durco T4E Lined Plug Valves Fluoropolymer Lined Valves

SPECIFICATIONS. Limitorque MX. Selection Data. Experience In Motion. Performance and Dimensions for MX Series 05 through 150 Electric Actuators

INTERNATIONAL METAL ENGINEERING

Integrated Control modules

Installation Instructions

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

S-17 CATALOG. Forged Steel Strainers

Valtek XL Series High Performance Positioner. for Control Valves

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Logix 505+ and 510+ Digital Positioners

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

TECHNICAL BULLETIN. Valtek Torex TX Control and Shut-off Valves Butterfly Valves. Experience In Motion VLENTB

Installation Instructions

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

brands you trust. CRANE - Automation Actuators and Instrumentation

INTERNATIONAL METAL ENGINEERING

Installation Instructions

Installation Instructions

Limit Switches. Series NI700 Installation, Maintenance and Operating Instructions

Rotary Valve Maxflo + 60 and 80 Opening type NT

Transcription:

Accord DS/DM Series UltraSwitch Switch box

Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Accord provides cost efficient, accurate and reliable position signaling for hazardous locations. The sturdy enclosure is offered in aluminum or corrosion resistant stainless steel and is provided with multiple switch options. An external indicator is available. The DS/DM is designed to be directly and easily mounted onto actuators for both rotary and linear indication. It may also be used as a junction box for direct connection of solenoid valves. Minimum two open terminals are always provided. Its compact housing has multiple mounting possibilities, up to three conduit entries and pre-wired switches to enable easy installation. It is designed to meet IP66 and NEMA Type 4X standards and is offered for general purpose/weather proof and for explosion proof hazardous locations. Features and Benefits SIL 2 Tool-free Quick-Set cams ATEX Ex d IIC T4 IECEx Ex d IIC T4 ccsa Class I, Division 1, Groups B,C,D, T4 CSAus Class I, Division 1, Groups A,B,C,D, T4 Switches available in a wide range of options (See Technical Data page - switch options) Easily accessed pre-wired terminal strip Minimum two open terminals are provided Housing of aluminum or corrosion resistant stainless steel Temperature range 2-55 C to +85 C -67 F to +180 F Conduit entries (2x) 3/4 NPT or (2x) M25x1.5mm (third entry optional) Optional 4-20mA feedback signal

Hazardous Locations Approvals Typical applications / industries suitable for the DS/DM-Series UltraSwitch are: Chemical Oil & Gas Pharmaceutical Offshore Hazardous locations approvals and communication Explosion proof: AS-Interface (AS-i) Approvals for: The DS/DM-series can be equipped with optional AS-i ATEX Ex d IIC T4 IECEx Ex d IIC T4 ccsa Class I, Division 1, Groups B,C,D, T4 CSAus Class I, Division 1, Groups A,B,C,D, T4 communication capabilities. This technology offers a very simple, flexible and cost efficient network system. Mounting options and visual indication NAMUR mounting kit with Indicator NAMUR mounting Standard NAMUR EN15714 mounting kits are available for standard NAMUR shafts. Available for 80x30 and 130x30 actuator top patterns with an actuator shaft height of 20, 30 or 50 mm. For linear applications the optional L shaft can be ordered. Visual indicator also shown. B Mounting kit NAMUR p/n 23648 23649 23650 A = Bolt pattern length (mm) 80 80 130 B = Bracket height (mm) 45 55 55 C = Height (mm) 145 155 155 C A 30 mm 3

Housing Aluminum or Stainless Steel housing Powder Epoxy painted Aluminum housing Base always black. Covers in black (standard), white or optional cover color on request Corrosion free Stainless Steel housing Unpainted stainless steel DIN 1.4408 4

Technical Data Switch Options Data/Materials Code Switch Option Manufacturer Load Capacity M1 SPDT Mechanical Honeywell MicroSwitch 15A @ 125/250 VAC; 0,5A @ 125 VDC; 0,25A @ 250VDC; 5A @ 120VAC MG SPDT Gold Mechanical Honeywell MicroSwitch 1A @ 125 VAC; 50 ma @ 24 VDC MC SPDT Mechanical Honeywell MicroSwitch Mechanical switch 250 F F3 IF5250 IFM 10-36VDC NC PNP, 150mA, 3-wire NC Data Ingress protection Weight Aluminum housing Weight Stainless Steel housing IEC 529 IP 66, Nema Type 4X 1.8kg / 4 lbs 3.5kg / 7.75 lbs F5 IF6001 IFM 18-32VDC, NO PNP, 150mA@50 C F6 IF6034 IFM 10-36VDC, NO PNP, 150mA, Stainless Steel F7 IN0074 IFM 20-250 AC/DC NO, 350mA/100mA F8 IN0081 IFM 20-250 AC/DC NO, 350mA/100mA w/led P5 SPDT Proximity Hamlin 0.25A @ 120 VAC; 0.25A @ 28 VDC (3 W Max.) PE SPDT Sabre Proximity Flowserve 1A @ 120 VAC; 1A @ 24 VDC PP SPDT Phazer Proximity Flowserve 3A @ 120 VAC; 2A @ 24 VDC PT SPST BRS Proximity Flowserve 3A @ 120 VAC; 0.5 @ 24 VDC N3 Slotted NAMUR PF SJ3.5-S1N NAMUR NO 2-wire Safety function N8 Solid State Proximity PF NJ2 V3 N NAMUR NC Sensor; 8 VDC N9 Solid State Proximity PF NBB3-V3-Z4 NPN Sourcing; 100 ma max. Current; 5-60 VDC NP Solid State Proximity PF SJ3.5-N NAMUR Sensor Output; 5-25 VDC Supply NQ Solid State Proximity PF NJ4-12GK-N NAMUR NC Sensor; 8 VDC NR Solid State Proximity PF NJ4-12GM40-E1 PNP Sinking; 200 ma max. Current; 10-60 VDC NS Solid State Proximity PF NJ4-12GM40-E2 NPN Sourcing; 200 ma max. Current; 10-60 VDC NT Solid State Proximity PF NJ4-12GK40-E2 NPN Sourcing; 200 ma max. Current; 10-60 VDC NW Solid State Proximity PF SJ3.5-SN NAMUR NC Sensor; 8 VDC Part Housings & Covers Shaft Cams/Splines Terminal Block Internal Brackets All External Fasteners All Internal Fasteners Indicator Label Certificate ATEX IECEx Material Powder epoxy painted Aluminum or Stainless Steel Stainless Steel Nylon Nylon Nylon, Aluminum or Stainless Steel Stainless Steel Stainless Steel Polyurethane Polyester or Stainless Steel II 2GD Ex d IIC T4 Gb Ex tb IIIC T113 C Db Ex d IIC T4 Gb Ex tb IIIC T113 C Db ccsa Class I, Division 1, Groups B,C,D, T4 CSAus Class I, Division 1, Groups A,B,C,D, T4 More switch options available 5

DS/DM-Series Ultraswitch Switch box Nomenclature A = B = C = D = E = F = G = H = I = J = K = L = M = Product & Connections (cable entry) DS Explosion proof / Flame proof switch box with 3/4 NPT cable entries DM Explosion proof / Flame proof switch box with M25x1,5 cable entries Number of open cable entries 2 2 x open cable entries (standard) 3 3 x open cable entries (option) Housing material /Surface treatment B Aluminum housing, polyester powdercoating, Black base & cover W Aluminum housing, polyester powdercoating, Black base & White cover C Aluminum housing, polyester powdercoating, Black base & Optional cover color S Stainless Steel housing Shaft D Double D Shaft 1/4 N Namur VDI/VDE 3845 Shaft (rotary actuators) T For NAF Turnex actuators L D style including nut for linear applications Indicator option 0 No indicator 1 Indicator Qty of switches 0 0 Switches 2 2 Switches 4 4 Switches Switch options - see page with switch options Certificate 14 General Purpose 18 ccsa Class I, Division 1, Groups B,C,D; Class II, Division 1, Groups E, F, G; Class III T4 CSAus Class I, Division 1, Groups A,B,C,D; Class II, Division 1, Groups E, F, G; Class III T4 19 ATEX II 2GD, Ex d IIC T4 Gb, Ex tb IIIC 25 IECEx Ex d IIC T4 Gb, Ex tb IIIC Product approval marking 0 Self-adhesive marking label, Polyester M Stainless steel marking plate Analog Output 0 None 4 4-20mA transmitter (G= none, M1 or MG only) Terminal Options 2 2 Extra open terminals (Standard) 4 4 Extra open terminals (Optional, not possible for all switch options) 6 6 Extra open terminals (Optional, not possible for all switch options) 8 8 Extra open terminals (Optional, not possible for all switch options) H Heavy Duty Terminal Block, 8 contact points. Options/ Elastomers 0 Nitrile O-rings Brand A Accord V Viton O-rings Ordering code example A B C D E F G H I J K L M DS 2 B N 1 2 MG - 14-0 0 2 0 A 6 Explosion proof / Flame proof switch box with 3/4 NPT cable entries, 2 Cable entries, Aluminum housing, NAMUR shaft, Indicator, 2 switches MG, General purpose, label, No output, 2 Extra terminals, Nitrile O-rings, Accord Brand

Dimensions DS/DM (mm/inch) M6(4X) Ø 125 (4.213) 35,4 (1.394) 57,2 (2.252) 3/4-14 NPT OR M25x1.5 (1-3x) 149 (5.866) 4 (.157) 93 (3.740) 99,3 (3.090) 15(.590) Ø56 (2.203) 137,5 (5.413) 57,2 (2.252) 35,4 (1.394) 21(.827) 5/16-18 UNC(4X) Clearance=145 (5.701) 7

FCD ACENBR0136-03-A4-12/15 To find your local Flowserve representative: For more information about Flowserve Corporation, visit flowserve.com Hazardous Locations ATEX II 2GD Ex d IIC T4 Gb Ex tb IIIC T113 C Db IECEx Ex d IIC T4 Gb Ex tb IIIC T113 C Db ccsa Class I, Division 1, Groups B,C,D, T4 CSAus Class I, Division 1, Groups A,B,C,D, T4 Flowserve Corporation Flow Control Division 1978 Foreman Drive Cookeville, Tennessee 38501 USA Phone: +931 432 4021 Fax: +931 432 5518 Flowserve Flow Control (UK) Ltd. 44 Victoria Way, Burgess Hill West Sussex, RH15 9NF UNITED KINGDOM Tel: +44 (0) 1444 884846 E-mail: pmvuksales@flowserve.com Flowserve Flow Control Benelux Rechtzaad 17 4703 RC Roosendaal THE NETHERLANDS Tel: +31 (0) 30 6771946 Fax: +27 (0) 30 6772471 E-mail: fcbinfo@flowserve.com Flowserve Flow Control GmbH Rudolf-Plank Strasse 2 D-76275 Ettlingen GERMANY Tel: +49 (0) 7243 103 0 Fax: +49 (0) 7243 103 222 E-mail: argus@flowserve.com Flowserve Spa Via Prealpi, 30 20032 Cormano (Milano) ITALY Tel: +39 (0) 2 663 251 Fax: +39 (0) 2 615 18 63 E-mail: infoitaly@flowserve.com Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware thatflowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide generalguidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume theultimateresponsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation and Maintenance (I & M) instructions included with the product, and train its employees and contractors in the safe useof Flowserve products in connection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. 2015 Flowserve Corporation, Irving, Texas, USA. Flowserve and PMV are registered trademarks of Flowserve Corporation. Flowserve Ahaus GmbH von-braun-str. 19a 48683 Ahaus Phone: +49 2561 686-119 Fax: +49 2561 686-109 Flowserve Corporation No. 35, Baiyu Road Suzhou Industrial Park Suzhou 215021, Jiangsu Province, PRC Phone: +86-512-6288-1688 Fax: +86-512-6288-8737 Flowserve Australia Pty Ltd Flow Control Division 14 Dalmore Drive Scoresby, Victoria 3179 Austrialia Phone: +61 3 9759 3300 Fax: +61 3 9759 3301 Flowserve Pte Ltd No. 12 Tuas Avenue 20 Singapore 638824 Phone: +65 6879 8900 Fax: +65 6862 4940 Flowserve do Brasil Ltda Rua Tocantins, 128 - Bairro Nova Gerti São Caetano do Sul, São Paulo 09580-130 Brazil Phone: +5511 4231 6300 Fax: +5511 4231 6329-423 flowserve.com