Factory Authorized Mechanism Enhancement (FAME)

Similar documents
Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

Removal/installation instructions for Series NRX (IZMX) drawout levering (racking) mechanism

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

Instruction Booklet IB E. Contents

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

Reprogramming guide. Power Defense ICCB. Instructional Leaflet IL EN WARNING WARNING. Instructions apply to:

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

3-way multi-family drawout cable interlock kit - type 32 - RF

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

Effective November 2016 Supersedes September 1998 (S )

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

Two-way cable interlock kit for Magnum drawout circuit breakers

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

Effective June 2016 New Issue

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

O & M Manual for the EATON Generator Ready Loadcenter

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

Effective March 2015 Supersedes S August 2012

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

Two-way cable interlock kit for Magnum fixed circuit breakers

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

Magnum Breaker Remote Racking Device (MRR1000)

High-voltage primary bushings installation instructions

COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

CCP2-FLR1-21_ flange-rod operating mechanism

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

Effective November 2016 Supersedes February 2012 (S )

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

Instructions for installation, operation, and maintenance of medium voltage VC-W MR2 (integral racking)

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

Type NR oil switch installation and operation instructions

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

Magnum breaker remote racking device (MRR1000)

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

COOPER POWER SERIES. KA716L7001 adjustable control valve kit for Types L, E, 4E, V4E, and V4L reclosers installation and adjustment instructions

Effective May 2017 Supersedes December 2004 (S )

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

Digitrip Retrofit System for the Federal Pioneer 25-H(L)-2, 30-H(L)-2, 30-H(L)-3, and 30-3 Breakers

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

50 / 75 / 150 DHP [Cable or Hard Bus Application] Ground and Test Device

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

Effective May 2017 Supersedes January 2003 (S )

38 kv Type VCPW-HD Simple Electrical Ground & Test Device (SEG&TD) lower terminal instruction booklet

Remote Power Racking System (RPR-2)

Simple Electrically Operated Ground & Test Device For use in Type VCP-W Switchgear rated up to 15kV, 25 and 40kA UPPER TERMINAL SET VERSION

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

Digitrip Retrofit System for Allis-Chalmers LA-600 F Electrically Operated Fused Breakers

AM-4.16/7.2/13.8-VR Replacement Circuit Breaker

Instructions for using Functional Test Kit on Digitrip 520 and 1150 family of Power Circuit Breaker Trip Units and Series G and FD MCCB Trip Units

www. ElectricalPartManuals. com Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers

AM4.16/7.2/13.8-VR + VR-Series + Replacement Circuit Breaker

Advanced Test Equipment Rentals ATEC (2832)

AMH-4.76-VR Replacement Circuit Breaker

IB PowlVac ITE-HK Remote Racking Device

COOPER POWER SERIES. KA146W5 single pole-mounting hanger; KA146W2 tank lifting windlass assembly and installation instructions. Reclosers MN280039EN

COOPER POWER SERIES. Metal-enclosed capacitor banks installation instructions. Power Capacitors MN230010EN

CM52 Network Protector with Arc Flash Reduction Module

COOPER POWER SERIES. Types D and DV recloser installation instructions. Reclosers MN280030EN

TVSS Installation for RLCM/CHGENLC, RLCU, and CHGEN ATSs

COOPER POWER SERIES. Metal-enclosed, pad-mounted capacitor banks installation instructions. Power Capacitors MN230009EN

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker

Flush Mount AIN ALPHA Meters. General. Hardware Kit

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

Vacuum Circuit Breaker (Vehicle)

Instruction and Installation Guide

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

COOPER POWER SERIES. Manually-Operated M-Force Switch Installation and Operation Instructions. Switches and Disconnects MN008003EN

Digitrip Retrofit System for BBC LKD 8 Breakers

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2

COOPER POWER SERIES. Instructions for oil-filled, single-phase overhead distribution transformers. Distribution Transformers MN201003EN

DANGER. See Wiring Diagrams on page 7 for illustrations of both internal and connection wiring diagrams. WARNING

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

Digitrip Retrofit System for the General Electric AKR 6D/7D-30/50 and AKRT 6D/7D-50 Series Breakers

5/15/27 kv, 25/31.5/50/63 ka Manual Ground & Test Devices Installation, Operations and Maintenance Manual

Digitrip Retrofit System for Siemens-Allis RLX-1600 Breakers

5HK-VR, 15HK-VR, & 17HK-VR - (Model 03) Replacement Circuit Breaker

T- VACR Fixed (up to 40kA) T-VAC Draw out (up to 40kA)

COOPER POWER SERIES. Fused loadbreak elbow connector installation instructions. Loadbreak Apparatus Connectors MN650014EN

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

Installation Power Management Unit Battery Cables and Battery Harness

Straight-Bore Clutch LSCC-32, 44, 54

Transcription:

Instruction Leaflet IL182403EN Supersedes April 2017 Effective July 2018 Factory Authorized Mechanism Enhancement (FAME) FAME Upgrade Shown

Factory Authorized Mechanism Enhancement (FAME) DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton s experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. m DANGER IMPROPERLY INSTALLING OR MAINTAINING THESE PRODUCTS CAN RESULT IN DEATH, SERIOUS PERSONAL INJURY OR PROPERTY DAMAGE. READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE ATTEMPTING ANY UNPACKING, ASSEMBLY, OPERATION OR MAINTENANCE OF THE CIRCUIT BREAKERS. INSTALLATION OR MAINTENANCE SHOULD BE ATTEMPTED ONLY BY QUALIFIED PERSONNEL. THIS IS A SUPPLEMENT TO THE OEM INSTRUCTION BOOKLET AND SHOULD NOT BE CONSIDERED ALL INCLUSIVE REGARDING INSTALLATION OR MAINTENANCE PROCEDURES. IF FURTHER INFORMATION IS REQUIRED, YOU SHOULD CONSULT EATON S ELECTRICAL SERVICES & SYSTEMS. The operating mechanism of this power circuit breaker was enhanced by Eaton with the latest materials and design concepts that were fully tested to applicable IEEE Standards. The enhancements extend the useful life and numbers of operations of the circuit breaker mechanism. These enhancements do not affect or improve the interrupting capabilities of the OEM circuit breaker design. All possible contingencies which may arise during installation, operation or maintenance, and all details and variations of this equipment do not purport to be covered by these additional instructions. If further information is desired by purchaser regarding his particular installation, operation or maintenance of particular equipment, contact an Eaton representative. THE CIRCUIT BREAKERS DESCRIBED IN THIS BOOK ARE DESIGNED AND TESTED TO OPERATE WITHIN THEIR NAMEPLATE RATINGS. OPERATION OUTSIDE OF THESE RATINGS MAY CAUSE THE EQUIPMENT TO FAIL, RESULTING IN DEATH, BODILY INJURY AND PROPERTY DAMAGE. ALL SAFETY CODES, SAFETY STANDARDS AND/OR REGULATIONS AS THEY MAY BE APPLIED TO THIS TYPE OF EQUIPMENT MUST BE STRICTLY ADHERED TO. VACUUM CIRCUIT BREAKERS ARE DESIGNED TO BE INSTALLED PURSUANT TO THE AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). SERIOUS INJURY, INCLUDING DEATH, CAN RESULT FROM FAILURE TO FOLLOW THE PROCEDURES OUTLINED IN THE OEM INSTRUCTION MANUAL AND THIS SUPPLEMENTAL INSTRUCTION LEAFLET. ii Instruction Leaflet IL182403EN July 2018 www.eaton.com

Factory Authorized Mechanism Enhancement (FAME) Table of Contents SECTION 1: INTRODUCTION 4 1.1 VISUAL INSTRUCTION BOOKLET ESSENTIALS 4 1.2 QUICK RESPONSE CODE 4 1.3 ADDITIONAL LABEL INFORMATION 4 1.4 FAME CIRCUIT BREAKER ENHANCEMENTS 5 SECTION 2: SAFE PRACTICES 5 SECTION 3: INSPECTION & MAINTENANCE 6 3.1 INSPECTION FREQUENCY 6 SECTION 4: REPLACEMENT PARTS 6 4.1 GENERAL 6 4.2 ORDERING INSTRUCTIONS 6 Instruction Leaflet IL182403EN July 2018 www.eaton.com iii

Factory Authorized Mechanism Enhancement (FAME) SECTION 1: INTRODUCTION This instruction leaflet provides updated information on VCP-W and VR-Series vacuum circuit breakers with the Factory Authorized Mechanism Enhancement (FAME). The FAME process is not a conversion, but rather an enhancement that upgrades an existing VCP-W or VR-Series metal-clad circuit breaker mechanism to the latest materials and components. The FAME process does not increase or modify the nameplate operating characteristics of the VCP-W or VR-Series, however, it offers these performance enhancements to the circuit breaker s mechanism: 10-year or 10,000 operation scheduled maintenance intervals. When applied in usual service conditions as defined by IEEE C37.04-1999, the FAME upgraded VCP-W and VR-Series requires maintenance only once every ten years or ten thousand operations, which ever comes first. NNote: See inspection and testing procedures in the OEM instruction booklet for details. Increased mechanical endurance. Circuit breakers in repetitive duty applications offer 50% more operations over conventional vacuum circuit breaker elements before parts replacement may be needed. Use this instruction leaflet in conjunction with the technical information provided with the OEM equipment order which includes electrical control schematic and wiring diagrams, outline diagrams, installations plans, and procedures for installation. Satisfactory performance is dependent on proper application, correct installation, and adequate inspection. It is very important that this instruction leaflet be read and followed closely to achieve optimum performance and a long useful circuit breaker life in its application. 1.1 VISUAL INSTRUCTION BOOKLET ESSENTIALS Eaton provides additional documentation designed to enhance the technical information provided in this instruction booklet for the VCP-W and VR-Series FAME circuit breakers. The Visual Instruction Booklet Essentials (VIBE) is a digital supplemental booklet featuring user interactive content and informative videos intended to assist with the maintenance of the VCP-W and VR-Series FAME circuit breaker. The VIBE document is available for immediate download at www.eaton.com/vr-series. DO NOT FOLLOW THE LUBRICATION INSTRUCTIONS SHOWN IN THE OEM INSTRUCTION BOOKLET. THE CIRCUIT BREAKER MECHANISM SHOULD NEVER BE OILED OR RE-LUBRICATED IN ANY MANOR AFTER THE FAME UPGRADE IS PERFORMED. THE FAME WARRANTY WILL VOID IF ANY LUBRICATION IS PERFORMED ON THE CIRCUIT BREAKER THAT HAS THE FAME PROCESS APPLIED. 1.2 QUICK RESPONSE CODE VCP-W and VR-Series FAME circuit breakers have a new front escutcheon plate which includes a quick response code (QR Code). The escutcheon is mounted on the front cover of the power circuit breaker. This QR Code is a matrix barcode that provides direct access to download VCP-W and VR-Series FAME specific documentation, such as this product instruction leaflet, product aids and the VIBE documentation. See Figure 1.1 for the featured VCP-W and VR-Series FAME QR Code and Figure 1.2 for the front escutcheon plate. Figure 1.1. Quick Response Code FAME QR Code Figure 1.2. Front Escutcheon Plate 1.3 ADDITIONAL LABEL INFORMATION The front cover of the FAME upgraded circuit breaker displays information specific to the FAME process in addition to the OEM label decals. An updated nameplate reflects the upgrade information. (Figures 1.3 and 1.4) Figure 1.3. Mechanism Notice Label Figure 1.4. Lubrication Notice Label NNote: A smart phone with an adequate QR Code Scanner application must be used. Downloading content may incur data charges from the mobile service provider. 4 Instruction Leaflet IL182403EN July 2018 www.eaton.com

Factory Authorized Mechanism Enhancement (FAME) SATISFACTORY PERFORMANCE OF THESE CIRCUIT BREAKERS IS CONTINGENT UPON PROPER APPLICATION, CORRECT INSTALLATION AND ADEQUATE MAINTENANCE. THIS INSTRUCTION LEAFLET ALONG WITH THE OEM INSTRUCTION BOOKLET MUST BE CAREFULLY READ AND FOLLOWED IN ORDER TO OBTAIN OPTIMUM PERFORMANCE FOR LONG USEFUL LIFE OF THE CIRCUIT BREAKERS. IT IS FURTHER RECOMMENDED THAT THE INSTALLATION BE PERFORMED BY AN EATON TRAINED ENGINEER OR TECHNICIAN. CIRCUIT BREAKERS ARE PROTECTIVE DEVICES, AS SUCH, THEY ARE MAXIMUM RATED DEVICES. THEREFORE, THEY SHOULD NOT UNDER ANY CIRCUMSTANCE BE APPLIED OUTSIDE THEIR NAMEPLATE RATINGS. ALL POSSIBLE CONTINGENCIES WHICH MIGHT ARISE DURING INSTALLATION, OPERATION, OR MAINTENANCE, AND ALL DETAILS AND VARIATIONS OF THIS EQUIPMENT ARE NOT COVERED BY THESE INSTRUCTIONS. IF FURTHER INFORMATION IS DESIRED BY THE PURCHASER REGARDING A PARTICULAR INSTALLATION, OPERATION, OR MAINTENANCE OF THIS EQUIPMENT, THE LOCAL EATON REPRESENTATIVE SHOULD BE CONTACTED. 1.4 FAME CIRCUIT BREAKER ENHANCEMENTS The FAME process does not change the rating, outline diagrams, or dimensions of the circuit breaker. The receiving, handling and storage for the FAME upgraded circuit breaker remains the same. Moreover, the initial inspection, installation, and operation of FAME upgraded circuit breakers remain the same as the OEM VCP-W and VR-Series circuit breakers. Refer to the OEM instruction booklet for information on these details. The inspection and maintenance guidelines for the FAME upgraded circuit breakers are different from the OEM guidelines. Refer to Section 3 for updated inspection and maintenance recommendations for the FAME upgraded circuit breakers. SECTION 2: SAFE PRACTICES Vacuum replacement circuit breakers are equipped with high speed, high energy operating mechanisms. They are designed with several built-in interlocks and safety features to provide safe and proper operating sequences. m DANGER TO PROTECT THE PERSONNEL ASSOCIATED WITH INSTALLATION, OPERATION, AND MAINTENANCE OF THESE CIRCUIT BREAKERS, THE FOLLOWING PRACTICES MUST BE FOLLOWED: Only qualified persons, as defined in the National Electrical Safety Code, who are familiar with the installation and maintenance of medium voltage circuits and equipment, should be permitted to work on these circuit breakers. Read these instructions carefully before attempting any installation, operation or maintenance of these circuit breakers. Always remove the circuit breaker from the enclosure before performing any maintenance. Failure to do so could result in electrical shock leading to equipment failure, resulting in death, severe personal injury, equipment damage and/or improper operation. Do not work on a circuit breaker with the secondary test coupler engaged. Failure to disconnect the test coupler could result in an electrical shock leading to equipment failure, resulting in death, severe personal injury, equipment damage and/or improper operation. Do not work on a closed circuit breaker or a circuit breaker with closing springs charged. The closing spring should be discharged and the main contacts open before working on the circuit breaker. Failure to do so could result in cutting or crushing injuries. Do not use a circuit breaker by itself as the sole means of isolating a high voltage circuit. Move the circuit breaker to the Disconnect position and follow all lockout and tagging rules of the National Electrical Code and any and all applicable codes, regulations and work rules. Do not leave the circuit breaker in an intermediate position in the circuit breaker compartment. Always have the circuit breaker either in the Disconnect / Test or Connect position. Failure to do so could result in a flash over and possible equipment failure, resulting in death, severe personal injury, equipment damage and/or improper operation. Always remove the maintenance tool from the circuit breaker after charging the closing springs. Circuit breakers are equipped with safety interlocks. Do not defeat them. This may result in equipment failure, resulting in death, severe personal injury, equipment damage and/or improper operation. Instruction Leaflet IL182403EN July 2018 www.eaton.com 5

Factory Authorized Mechanism Enhancement (FAME) SECTION 3: INSPECTION & MAINTENANCE DO NOT WORK ON A CIRCUIT BREAKER IN THE CONNECT POSITION. DO NOT WORK ON A CIRCUIT BREAKER WITH SECONDARY DISCONNECTS ENGAGED. DO NOT WORK ON A CIRCUIT BREAKER WITH SPRINGS CHARGED OR CONTACTS CLOSED. DO NOT DEFEAT ANY SAFETY INTERLOCKS. DO NOT LEAVE MAINTENANCE TOOL IN THE SOCKET AFTER CHARGING THE CLOSING SPRINGS. STAND AT LEAST ONE METER AWAY FROM THE CIRCUIT BREAKER WHEN TESTING FOR VACUUM INTEGRITY. FAILURE TO FOLLOW ANY OF THESE INSTRUCTIONS MAY CAUSE EQUIPMENT FAILURE, RESULTING IN DEATH, SEVERE PERSONAL INJURY, EQUIPMENT DAMAGE AND/OR IMPROPER OPERATION. SEE SECTION 2 - SAFE PRACTICES FOR MORE INFORMATION. SECTION 4: REPLACEMENT PARTS 4.1 GENERAL The FAME upgrade is achieved with custom engineered subassemblies available only from Eaton s Power Breaker Center (PBC) and are not required for general maintenance or purchase for renewal parts. The FAME upgrade and repairs to the FAME mechanism should only be performed at Eaton s PBC or one of the Power Breaker Reconditioning centers (PBRc). DO NOT ATTEMPT TO REPAIR A FAME MECHANISM USING ANY OF THE RENEWAL PARTS LISTED IN THE OEM INSTRUCTION MANUAL. In order to minimize production downtime, it is recommended that an adequate quantity of spare control parts be carried in stock. The quantity will vary from customer to customer, depending upon the service severity and continuity requirements. Each customer should develop their own level based on operating experience. However, when establishing a new operating record, it is a good practice to stock one set of control components for every six circuit breakers of the same control voltage. This quantity should be adjusted with time and frequency of operation of the circuit breakers. These components are not included in the FAME upgrade. Refer to the OEM instruction booklet for replacement control components. 3.1 INSPECTION FREQUENCY The scheduled maintenance interval of a FAME upgraded power circuit breaker is 10 years or 10,000 operations, whichever comes first. However, it is recommended that the circuit breaker be inspected and cleaned on a regular interval based on the surrounding ambient conditions. Dust, contaminants and moisture can combine to create voltage tracking on the surfaces of insulating materials. An inspection schedule should be created based on the surrounding ambient conditions. Inspection schedules typically range from 1 to 5 years, but may extend to more or less frequency depending on the cleanliness of the circuit breaker installation. A vacuum integrity test should be performed as outlined in the OEM instruction booklet before the initial installation of a FAME upgraded circuit breaker and also anytime the circuit breaker is transported to a new circuit breaker compartment location. Additionally, it is recommended to inspect the circuit breaker every time it interrupts fault current. NNote: The OEM instruction booklet contains specific inspection, maintenance and trouble shooting procedures. Refer to the table in the OEM instruction manual for maintenance and trouble-shooting. DO NOT FOLLOW THE LUBRICATION INSTRUCTIONS SHOWN IN THE OEM INSTRUCTION BOOKLET. THE CIRCUIT BREAKER MECHANISM SHOULD NEVER BE OILED OR RE-LUBRICATED IN ANY MANOR AFTER THE FAME UPGRADE IS PERFORMED. THE FAME WARRANTY WILL VOID IF ANY LUBRICATION IS PERFORMED ON THE CIRCUIT BREAKER THAT HAS THE FAME PROCESS APPLIED. 6 Instruction Leaflet IL182403EN July 2018 www.eaton.com

Factory Authorized Mechanism Enhancement (FAME) Instruction Leaflet IL182403EN July 2018 www.eaton.com 7

Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 2018 Eaton All Rights Reserved Printed in USA Publication No. IL182403EN July 2018 Eaton is a registered trademark. All trademarks are property of their respective owners.