An American Control Electronics Brand RG500 SERIES USER MANUAL RG500UA RG500UA-PCM RG500A RG510UA RG510UA-PCM RG510A.

Similar documents
DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

17429X.00 SERIES MODELS:

USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM

User s Manual. SCR, Adjustable Speed Drives for DC Brush Motors

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

Models: User s Manual. Pulse-Width Modulated, Adjustable Speed Drives for DC Brush Motors

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

An American Control Electronics Brand. RG6xU SERIES USER MANUAL RG60U RG61U.

SCR THYRISTOR MOTOR CONTROLS , , , , , , M , M , M OPERATION MANUAL

MM23xx1C Series USER MANUAL MM23001C MM23001C-Q MM23011C MM23011C-Q MM23101C MM23111C MM23201C MM23211C MM23401C MM23411C.

XP Series USER MANUAL PCMXP02-115AC PCMXP05-115AC PCMXP10-115AC XP02-115AC XP02-115AC-Q XP05-115AC XP10-115AC.

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

DC3RD Digital Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC. Instruction Manual D2-3455

RG500 SERIES USER S MANUAL. SCR, Dual Voltage, Adjustable-Speed Regenerative Drives for DC Brush Motors

MM501U. User s Manual. SCR, Dual-Voltage, Adjustable Speed Drive for DC Brush Motors

PWP Series USER MANUAL PWP100-2 PWP100-2-QDT PWP100-5 PWP PWP101-2 PWP101-5 PWP

C1XP Series. Models: C1XP01-115AC C1XP03-115AC C1XP03-D240AC USER MANUAL

SPEEDMASTER. Operation Manual & NEMA 4X SCR MOTOR CONTROLS

MHS Series USER MANUAL MHS MHS MHS MHS443-10

USER S MANUAL VFD05-D230-PCM VFDP4X04-D230-PCM VFDA4X04-D230-PCM VFDF4X04-D230-PCM VFDS4X05-D230-PCM

VFD Series USER MANUAL VFD02-115AC VFD02-230AC VFD02-D230AC VFD04-115AC VFD04-230AC VFD04-D230AC.

Excel [XL] Series USER S MANUAL

Model A Switching Logic Board. User s Manual. For Use With Minarik Full-Wave Regenerative Drives

USER S MANUAL

Boston Gear Ratiotrol DC Motor Speed Control

User s Manual MMVFD SERIES MODEL: MMVFD06-D230AC. Variable-frequency drives for 3-phase AC motors

MM03-PCM MM10-PCM. User s Manual. SCR, Adjustable Speed Drives for DC Brush Motors

USER S MANUAL VFD SERIES. Variable-frequency drives for 3-phase and single-phase AC motors

USER S MANUAL. Variable-frequency drive for 3-phase and single-phase AC motors

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Boston Gear Ratiotrol DC Motor Speed Control

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

CONTROL FEATURES AVAILABLE OPTIONS

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE MODEL KBRG-255 (5HP) KB Part No FULL WAVE 4 QUADRANT FWD ACCEL REV ACCEL FWD CL

Fincor Series 2230 MKII/2240

USER S MANUAL. Variable-frequency drives for 3-phase and single-phase AC motors

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.

Boston Gear Ratiotrol DC Motor Speed Control

Boston Gear Ratiotrol

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE FULL WAVE 4 QUADRANT REV S/LT NLT R33 AC LINE FUSE ARMATURE F2 FUSE TB2

Filtered PWM Speed Control for Permanent Magnet DC Motors

DC3N Non-Regenerative DC Drives

Installation & Operation Manual


Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Description

WDC CONTROL SERIES. Instruction Manual. Variable Speed DC Control

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

BC141, BC142, BC142-5 & BC142-6 DC Control

DC Variable Speed Drive Panel

Installation and Operating Manual

Series 2330MKII. Single-Phase. Adjustable-Speed. DC Motor Controllers (1/6 3 HP) BOOK 0958-B

Installation and Operation Manual. *See page 6 for CE Information

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

MaxPak Plus Analog DC V S Drive

Boston Gear Ratiotrol

KBPC-240D (Part Nos and 9342) Installation and Operation Manual Supplement

Boston Gear. Adjustable-Speed Regenerative DC Motor Controllers. Installation and Operation Manual. Doc. No RBA-RG VEA-RG Series

SERIES 2600/2610 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-5 HP)

5001TCP SPEED CONTROLLER

INSTALLATION AND OPERATION MANUAL SUPPLEMENT KBPC-225 (PART NOS & 9392)

SAFTRONICS DF8 PLUS SERIES

RBD Series. Installation and Maintenance Manual. An Altra Industrial Motion Company

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

WarninG TraDeMarkS Copyright 2013, 2018 Automationdirect.com Incorporated All Rights Reserved

KBWS WHISPER DRIVE PULSE WIDTH MODULATED (PWM)

Copyright 2013 Automationdirect.com Incorporated All Rights Reserved

5001TCP SPEED CONTROLLER

KBMD-240D MULTI-DRIVE

DUAL SWIVEL REEL OPERATING INSTRUCTIONS

Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT. For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO

Boston Gear Ratiotrol

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

Boston Gear Ratiotrol

Boston Gear Ratiotrol

CABINET REEL OPERATING INSTRUCTIONS

Table of Contents General Information Specifications Dimensions Programming Instructions Installation Parts List Input Devices

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

BLAZER D.C. MOTOR CONTROL

Dayton DC Motor Control

BC200/BC201 Regenerative Drive Adjustable Speed DC Control

Boston Gear RB Series

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

User Guide 4Q kW D.C.Motor Regenerative Speed Controller. Part Number: Issue Number: 3

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

MELLTRONICS DRIVES. Single Phase Regenerative DC Drives ¼ HP TO 7½ HP INSTALLATION OPERATION MAINTENANCE

TABLE OF CONTENTS STANDARD FEATURES

Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101

Boston Gear Ratiotrol

CABINET REEL OPERATING INSTRUCTIONS

BC203 Regenerative Drive Adjustable Speed DC Control

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

TRAC-3 TENSION READOUT AND CONTROL

Type ABL-3906C Low-Voltage Brushless DC Motor Controls (IP-00)

Transcription:

An American Control Electronics Brand RG500 SERIES USER MANUAL RG500UA RG500UA-PCM RG500A RG510UA RG510UA-PCM RG510A www.minarikdrives.com

Dear Valued Consumer: Congratulations on your purchase of the RG500 Series drive. This User Manual was created for you to get the most out of your new device and assist with the initial setup. Please visit www.minarikdrives.com to learn more about our other drives. Thank you for choosing Minarik Drives! No part of this document may be reproduced or transmitted in any form without written permission from American Control Electronics. The information and technical data in this document are subject to change without notice. American Control Electronics makes no warranty of any kind with respect to this material, including, but not limited to, the implied warranties of its merchantability and fitness for a given purpose. American Control Electronics assumes no responsibility for any errors that may appear in this document and makes no commitment to update or to keep current the information in this document.

Safety First!! WARNING! SAFETY WARNINGS Text in gray boxes denote important safety tips or warnings. Please read these instructions carefully before performing any of the procedures contained in this manual. DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED. Have a qualified electrical technician install, adjust and service this equipment. Follow the National Electrical Code and all other applicable electrical and safety codes, including the provisions of the Occupational Safety and Health Act (OSHA), when installing equipment. Reduce the chance of an electrical fire, shock, or explosion by using proper grounding techniques, over-current protection, thermal protection, and enclosure. Follow sound maintenance procedures.! WARNING! It is possible for a drive to run at full speed as a result of a component failure. Minarik Drives strongly recommends the installation of a master switch in the main power input to stop the drive in an emergency. Circuit potentials are at 115 VAC or 230 VAC above earth ground. Avoid direct contact with the printed circuit board or with circuit elements to prevent the risk of serious injury or fatality. Use a non-metallic screwdriver for adjusting the calibration trim pots. Use approved personal protective equipment and insulated tools if working on this drive with power applied. i

Table of Contents Section 1. Regenerative Drives... 1 Section 2. Specifications... 2 Section 3. Dimensions... 4 Section 4. Installation... 8 Heat Sinking... 8 Chassis... 8 NEMA 4X... 8 Mounting... 9 Chassis... 9 Speed Adjust Potentiometer...10 NEMA 4X...11 Wiring...12 Shielding Guidelines...13 Line Fusing...14 Connections...16 Power Inputs...16 Motor...16 Field Output Connections...17 Speed Adjust Potentiometer...18 Speed Adjust Potentiometer (-PCM models)...19 Analog Input Signal...20 Analog Input Signal (-PCM models)...21 +15 and -15...22 Enable, Regen Brake, Inhibit...22 Direction Switch...22 Tachogenerator Feedback...23 ii

Section 5. Operation... 27 Before Applying Power...27 Select Switches...28 Input Voltage Select (SW501, SW502)...28 Armature Voltage Select (SW503)...28 Feedback Select (SW504)...28 Signal Select (SW501) (-PCM models)...29 Input Voltage Select (SW502) (-PCM models)...29 Startup (Chassis models)...30 Startup (NEMA 4X models)...31 Starting and Stopping Methods...32 Automatic Restart Upon Power Restoration...32 Line Starting and Stopping...32 Regenerative Brake to Zero Speed (INHIBIT Terminals)...33 Regenerative Decel to Zero Speed (RB1 and RB2 Terminals)...34 Regenerative Decel to Minimum Speed...35 Coast to Zero Speed (INHIBIT-RUN)...36 Section 6. Calibration... 37 Minimum Speed (MIN SPD)...37 Maximum Speed (MAX SPD)...38 Forward Torque (FWD TQ)...39 Reverse Torque (REV TQ)...40 IR Compensation (IR COMP)...41 Forward Acceleration (FWD ACC)...43 Reverse Acceleration (REV ACC)...43 Deadband...44 Tachogenerator (TACH)...45 -MIN OUT, MAX OUT, and SIGNAL INPUT ADJUST (-PCM models)...46 iii

Section 7.Application Notes... 48 Direction Switch...48 Multiple Fixed Speeds...49 Adjustable Speeds Using Potentiometers In Series...50 Independent Adjustable Speeds...51 Independent Adjustable Forward and Reverse Speeds...52 RUN/JOG Switch - Inhibit Connection...53 RUN/JOG Switch - Potentiometer Connection...54 Leader-Follower Application...55 Single Speed Potentiometer Control Of Multiple Drives...56 Section 8. Troubleshooting... 57 Before Troubleshooting...57 Section 9. Accessories & Replacement Parts... 60 Notes... 61 Unconditional Warranty... 62 iv

List of Tables Table 1 Table 2 Table 3 Recommended Line Fuse Sizes...15 Short Circuit Current Ratings...15 Field Output Connections...17 List of Figures Figure 1 Four Quadrant Operation... 1 Figure 2 RG500UA and RG510UA Dimensions... 4 Figure 3 RG500UA-PCM and RG510UA-PCM Dimensions... 5 Figure 4 RG500A and RG510A Dimensions... 6 Figure 5 223-0235 Dimensions... 7 Figure 6 Speed Adjust Potentiometer...10 Figure 7 Speed Adjust Potentiometer Connections...18 Figure 8 -PCM Speed Adjust Potentiometer Connections...19 Figure 9 Analog Input Signal Connections...20 Figure 10 -PCM Analog Input Signal Connections...21 Figure 11 RG500UA and RG510UA Connections...24 Figure 12 RG500UA-PCM and RG510UA-PCM Connections...25 Figure 13 RG500A and RG510A Connections...26 Figure 14 Select Switches...28 Figure 15 SW501 Settings...29 Figure 16 -PCM Select Switches...29 Figure 17 Inhibit Terminals...33 Figure 18 Run/Decelerate to Minimum Speed Switch...35 Figure 19 Inhibit-Run Terminal Location and Run/Coast Switch...36 v

List of Figures Figure 1 Four Quadrant Operation... 1 Figure 2 RG500UA and RG510UA Dimensions... 4 Figure 3 RG500UA-PCM and RG510UA-PCM Dimensions... 5 Figure 4 RG500A and RG510A Dimensions... 6 Figure 5 223-0235 Dimensions... 7 Figure 6 Speed Adjust Potentiometer...10 Figure 7 Speed Adjust Potentiometer Connections...18 Figure 8 -PCM Speed Adjust Potentiometer Connections...19 Figure 9 Analog Input Signal Connections...20 Figure 10 -PCM Analog Input Signal Connections...21 Figure 11 RG500UA and RG510UA Connections...24 Figure 12 RG500UA-PCM and RG510UA-PCM Connections...25 Figure 13 RG500A and RG510A Connections...26 Figure 14 Select Switches...28 Figure 15 SW501 Settings...29 Figure 16 -PCM Select Switches...29 Figure 17 Inhibit Terminals...33 Figure 18 Run/Decelerate to Minimum Speed Switch...35 Figure 19 Inhibit-Run Terminal Location and Run/Coast Switch...36 Figure 20 Recommended FWD TQ, REV TQ, and IR COMP Settings...42 Figure 21 Deadband Settings...44 Figure 22 Forward-Reverse Switch...48 Figure 23 Forward-Stop-Reverse Switch...48 Figure 24 Multiple Fixed Speeds...49 Figure 25 Adjustable Speeds Using Potentiometers in Series...50 Figure 26 Independent Adjustable Speeds...51 Figure 27 Independent Adjustable Forward and Reverse Speeds...52 Figure 28 Independent Adjustable Forward and Reverse Speeds with Stop...52 vi

Figure 29 RUN/JOG Switch - Inhibit Connection...53 Figure 30 RUN/JOG Switch - Speed Adjust Potentiometer Connection.. 54 Figure 31 Leader-Follower Application...55 Figure 32 Single Speed Potentiometer Control of Multiple Drives...56 vii

Section 1. Regenerative Drives Most non-regenerative, variable speed, DC drives control current flow to a motor in one direction. The direction of current flow is the same direction as the motor rotation. Non-regenerative drives operate in Quadrant I, and also in Quadrant III if the drive is reversible (see Figure 1). Motors must stop before reversing direction. Unless dynamic braking is used, non regenerative drives cannot decelerate a load faster than coasting to a lower speed. Quadrant II Quadrant III MOTOR ROTATION Quadrant I Quadrant IV MOTOR TORQUE NOTE: ARROWS IN SAME DIRECTION = MOTOR ACTION Regenerative drives operate ARROWS IN OPPOSITE DIRECTION = REGENERATIVE ACTION in two additional quadrants: Quadrant II and Quadrant Figure 1. Four Quadrant Operation IV. In these quadrants, motor torque is in the opposite direction of motor rotation. This allows regenerative drives to reverse a motor without contactors or switches, to control an overhauling load, and to decelerate a load faster than it would to coast to a lower speed. 1

Section 2. Specifications Model Maximum Armature Current (ADC) HP Range with 90 VDC Motor HP Range with 180 VDC Motor Enclosure RG510UA RG510UA-PCM RG510A RG500UA* RG500UA-PCM* RG500A 3.0 1/20-1/4 1/10-1/2 Chassis Chassis NEMA 4X 10.0 1/8-1 1/4-2 Chassis Chassis NEMA 4X * Heat sink kit part number 223-0235 must be used when the continuous current output is over 7 amps. AC Line Voltage DC Armature Voltage with 115 VAC Line Voltage with 230 VAC Line Voltage Field Voltage with 115 VAC Line Voltage with 230 VAC Line Voltage Maximum Field Current Acceleration Time Range Deceleration Time Range Analog Input Range Non -PCM models (signal must be isolated; RB1 to S2) Voltage Signal Range PCM models Voltage Signal Range Current Signal Range 115/230 VAC ± 10% 50/60 Hz, single phase 0-90 VDC 0-180 VDC 50 VDC (F1 to L1); 100 VDC (F1 to F2) 100 VDC (F1 to L1); 200 VDC (F1 to F2) 1 ADC 0.5-15 seconds 0.5-15 seconds 0 to ± 10 VDC 0 to ± 250 VDC 4-20 ma 2

Input Impedance Non -PCM models (RB1 to S2) -PCM models (Voltage Signal) -PCM models (1-5 ma Signal) -PCM models (4-20 ma Signal) -PCM models (10-50 ma Signal) Form Factor Load Regulation with Armature Feedback with Tachogenerator Feedback Vibration Safety Certification Ambient Temperature Range Chassis models Enclosed models 32K ohms >25K ohms 1K ohms 235 ohms 100 ohms 1.37 at base speed 1% base speed or better 0.1% base speed 0.5G maximum (0-50 Hz) 0.1G maximum (> 50 Hz) UL Recognized Component, File # E132235 CSA Certified Component, File # LR41380 10 C - 55 C 10 C - 40 C 3

C501 FAST ACTING FUSES ONLY R501 SW502 SW501 T505 R502 SW503 T504 T503 T502 T501 R503 ARMATURE FEEDBACK 90 180 ARM TACH SW504 SO502 C502 C503 TB501 IC501 IC502 TB502 C505 RG500 Series Section 3. Dimensions 0.19 [5] FU501 FU502 L1 L2 C504 C507 C506 C510 8.90 [228] 8.40 [213] SCR501 SCR502 SCR503 SCR504 SCR505 SCR506 SCR507 SCR508 C509 R504 R505 R506 C508 115 230 230 115 INH-RUN SO501 INHIBIT P501 P502 P503 P504 P505 P506 P507 P508 P509 MIN SPD FWD TQ REV TQ IR COMP MAX SPD FWD ACC REV ACC DB TACH S3 S2 S1 S0 RB1 RB2-15 +15 T1 T2 L1 L2 230V L2 115V GND F1 F2 A2 A1 3.50 [89] 4.78 [121] 1.85 [47] 0.92 [23] ALL DIMENSIONS IN INCHES [MILLIMETERS] Figure 2. RG500UA and RG510UA Dimensions 4

FAST ACTING FUSES ONLY C506 C505 C508 C507 C501 C502 SW502 SW501 C503 T505 C504 SW501 SW502 TP L2 L1 C502 C503 TB501 IC501 IC502 TB502 C505 RG500 Series 0.19 [5] 8.90 [226] 8.40 [213] FU501 L1 SCR501 FU502 L2 T501 C504 IC505 MAX OUT P502 COM IC502 IC501 115 230 230 115 IC503 MIN OUT P503 1-5mA 4-20mA 10-50mA SIGNAL INPUT ADJUST 1 2 3 IC504 P501 R501 INH INPUT VOLTAGE SELECT 115 230 OUT 1 OUT 2-15 +15 COM INPUT 1 INPUT 2 POL REV MIN SPD FWD TQ REV TQ IR COMP MAX SPD FWD ACC REV ACC DB TACH S3 S2 S1 S0 RB1 RB2-15 +15 T1 T2 L1 L2 230V L2 115V GND F1 F2 A2 A1 3.50 [89] 4.78 [121] 3.07 [78] 1.85 [47] 0.92 [23] ALL DIMENSIONS IN INCHES [MILLIMETERS] 5 Figure 3. RG500UA-PCM and RG510UA-PCM Dimensions

6.90 [175] 6.30 [160] POWER 40 SPEED 50 60 I 30 20 10 70 80 90 1.40 [36] O 0 100 10.22 [260] 9.80 [249] REVERSE BRAKE FORWARD 7.00 [178] 0.22 [6] 1.45 [37] 5.51 [140] 4.78 [121] 2.31 [59] 0.12 [3] 1.50 [38] 1.50 [38] ALL DIMENSIONS IN INCHES [MILLIMETERS] Figure 4. RG500A and RG510A Dimensions 6

6.90 [175] 6.60 [168] 0.3 [8] 1.375 [35] 8.375 [213] 9.78 [249] ALL DIMENSIONS IN INCHES [MILLIMETERS] 7 Figure 5. 223-0235 Dimensions

Section 4. Installation! WARNING! Do not install, rewire, or remove this control with input power applied. Failure to heed this warning may result in fire, explosion, or serious injury. Make sure you read and understand the Safety Precautions on page i before attempting to install this product. Heat Sinking Chassis Models RG500UA and RG500UA-PCM require an additional heat sink when the continuous armature current is above 7 amps. Use Minarik Drives heat sink kit part number 223-0235. All other chassis drives have sufficient heat sinking in their basic configuration. Use a thermally conductive heat sink compound (such as Dow Corning 340 Heat Sink Compound) between the chassis and the heat sink surface for optimum heat transfer. NEMA 4X All NEMA 4X models come with the heat sink already attached. Therefore, all NEMA 4X drives have sufficient heat sinking in their basic configuration. 8

Mounting Chassis Drive components are sensitive to electrostatic discharge. Avoid direct contact with the circuit board. Hold the drive by the heat sink only. Protect the drive from dirt, moisture, and accidental contact. Provide sufficient room for access to the terminals and calibration trim pots. Mount the drive away from heat sources. Operate the drive within the specified ambient operating temperature range. Prevent loose connections by avoiding excessive vibration of the drive. Mount the drive with its board in either a horizontal or vertical plane. Six 0.19 (5 mm) wide slots in the chassis accept #8 pan head screws. Fasten either the large base or the narrow flange of the chassis to the subplate. The chassis should be earth grounded. Use a star washer beneath the head of at least one of the mounting screws to penetrate the anodized surface and to reach bare metal. 9

Speed Adjust Potentiometer! WARNING! Be sure that the potentiometer tabs do not make contact with the potentiometer s body. Grounding the input will cause damage to the drive. If using a remote potentiometer with a chassis drive, mount the speed adjust potentiometer through a 0.38 in. (10 mm) hole with the hardware provided (Figure 6). Install the circular insulating disk between the panel and the 10K ohm speed adjust potentiometer. Twist the speed adjust potentiometer wire to avoid picking up unwanted electrical noise. If the speed adjust potentiometer wires are longer than 18 in. (46 cm), use shielded cable. Keep the speed adjust potentiometer wires separate from power leads (L1, L2, A1, A2, F1, F2). MOUNT THROUGH A 0.38 IN. (10 MM) HOLE CW WIPER CCW NUT STAR WASHER SPEED ADJUST POTENTIOMETER PANEL INSULATING DISK POT TAB ASSIGNMENTS Figure 6. Speed Adjust Potentiometer 10

Mounting (NEMA 4X Enclosures) NEMA 4X cased drives come with two 0.88 inch (22 mm) conduit knockout holes at the bottom of the case. The units may be vertically wall mounted using the four 0.19 inch (5 mm) slotted holes on the attached heat sink. For motor loads less than 5 ADC, the drive may be bench mounted horizontally or operated without mounting. 1. Install the mounting screws. 2. For access to the terminal strip, turn the slotted screw on the front cover counterclockwise until it is free from the case. The right side of the cover is hinged to the case. Pull the slotted screw to open the case. 3. Carefully remove the conduit knockouts by tapping them into the case and twisting them off with pliers. 4. Set the POWER switch to the OFF position before applying the AC line voltage. 5. Install conduit hardware through the 0.88 inch (22 mm) knockout holes. Connect external wiring to the terminal block. 6. Grasp the slotted screw and tilt the front cover back into place. Avoid pinching any wires between the front cover and the case. 7. Turn the slotted screw clockwise until tight to secure the front cover. 11

Wiring! WARNING! Do not install, rewire, or remove this control with input power applied. Failure to heed this warning may result in fire, explosion, or serious injury. Circuit potentials are at 115 or 230 VAC above ground. To prevent the risk of injury or fatality, avoid direct contact with the printed circuit board or with circuit elements. Do not disconnect any of the motor leads from the drive unless power is removed or the drive is disabled. Opening any one motor lead while the drive is running may destroy the drive. This product does not have internal solid state motor overload protection. It does not contain speed-sensitive overload protection, thermal memory retention or provisions to receive and act upon signal from remote devices for over temperature protection. If motor over protection is needed in the end-use product, it needs to be provided by additional equipment in accordance with NEC standards. Use 18-24 AWG wire for logic wiring. Use 14-16 AWG wire for AC line and motor wiring. 12

Shielding Guidelines! WARNING! Under no circumstances should power and logic level leads be bundled together. Induced voltage can cause unpredictable behavior in any electronic device, including motor controls. As a general rule, Minarik Drives recommends shielding of all conductors. If it is not practical to shield power conductors, it is recommended to shield all logic-level leads. If shielding of all logic-level leads is not practical, the user should twist all logic leads with themselves to minimize induced noise. It may be necessary to earth ground the shielded cable. If noise is produced by devices other than the drive, ground the shield at the drive end. If noise is generated by a device on the drive, ground the shield at the end away from the drive. Do not ground both ends of the shield. If the drive continues to pick up noise after grounding the shield, it may be necessary to add AC line filtering devices, or to mount the drive in a less noisy environment. Logic wires from other input devices, such as motion controllers and PLL velocity controllers, must be separated from power lines in the same manner as the logic I/O on this drive. 13

Line Fusing Models RG500UA, RG500UA and RG500A are preinstalled with 20 amp fuses. Models RG510UA, RG510UA-PCM and RG510A are preinstalled with 8 amp fuses. Preinstalled line fuses are rated for maximum horsepower. If the horsepower rating of the motor being used is less than the maximum horsepower rating of the drive, the line fuse may have to be replaced with a lower rated one. Fuses should be rated for 250 VAC or higher and approximately 150% of the maximum armature current. Refer to Table 1 on page 15 to install a lower rated fuse. Refer to Table 2 on page 15 for Short Circuit Current Ratings (SCCR). 14

Table 1. Recommended Line Fuse Sizes 90 VDC Motor Horsepower 180 VDC Motor Horsepower Maximum DC Armature Current (amps) AC Line Fuse Size (amps) 1/20 1/15 1/8 1/6 1/10 1/8 1/4 1/3 0.5 0.8 1.5 1.7 1 1.5 3 3 1/4 1/2 2.5 5 1/3 1/2 3/4 1 3/4 1 1 1/2 2 3.5 5.0 7.5 10 8 10 15 15 Minarik Drives offers fuse kits. See Section 9: Accessories and Replacement Parts for fuse kit part numbers. Table 2. Short Circuit Current Ratings Drive Model Short Circuit Current Rating Maximum Current, A Maximum Voltage, V Types of Branch Circuit Protection Maximum Rating of Overcurrent Protection RG500UA RG500UA-PCM RG500A 10,000 240 V Non-time Delay K5 Fuse Inverse Time Circuit Breaker 30 A 15

Connections! WARNING! Do not connect this equipment with power applied. Failure to heed this warning may result in fire, explosion, or serious injury. Minarik Drives strongly recommends the installation of a master power switch in the voltage input line, as shown in Figures 11 and 12 on pages 24 and 25. The switch contacts should be rated at a minimum of 200% of motor nameplate current and 250 volts. Power Input For chassis models, connect the AC line power leads to terminals L1 and L2 (115) if using a 115 VAC line or to terminals L1 and L2 (230) if using a 230 VAC line. Minarik Drives recommends the use of a singlethrow, double-pole master power switch. The switch should be rated at a minimum of 250 volts and 200% of motor current. Refer to Figures 11 and 12 on page 24 and 25. For NEMA 4X models, the connect the AC line power leads to terminals 1 and 2 if using a 115 VAC line or to terminals 1 and 3 if using a 230 VAC line. Refer to Figure 13 on page 26. Motor Drives supply motor armature voltage from A1 and A2 terminals. It is assumed throughout this manual that, when A1 is positive with respect to A2, the motor will rotate clockwise (CW) while looking at the output shaft protruding from the front of the motor. If the motor does not spin in the desired direction, remove power and reverse the A1 and A2 connections. Connect a DC motor to terminals A1 and A2 as shown in Figures 11, 12 and 13 on pages 24, 25 and 26. Ensure that the motor voltage rating is consistent with the drive s output voltage. 16

Field Output Connections! WARNING! The field output is for shunt wound motors only. Do not make any connections to F1 and F2 when using a permanent magnet motor. See Table 3 for field output connections. Use 14-16 AWG wire to connect the field output to a field / shunt wound motor. Table 3. Field Output Connections Line Voltage (VAC) 115 115 230 230 Approximate Field Voltage (VDC) 50 100 100 200 Connect Motor Field To F1 and L1 F1 and F2 F1 and L1 F1 and F2 17

Speed Adjust Potentiometer Use a 10K ohm, 1/4 W potentiometer for speed control. The motor can operate in one direction (unidirectional) or two directions (bidirectional) depending on how the speed adjust potentiometer is connected to the drive. For unidirectional operation in the foward direction, connect the speed adjust potentiometer as shown in Figure 7(a). For unidirectional operation in the reverse direction, connect the speed adjust potentiometer as shown in Figure 7(b). For bidirectional operation, connect the speed adjust potentiometer as shown in Figure 7(c). The motor does not operate when the potentiometer is in the center position. Turning the potentiometer clockwise (CW) from the center position causes the motor to rotate in the forward direction, while turning the potentiometer counterclockwise (CCW) causes rotation in the reverse direction. S3 S2 S1 S0 S3 S2 S1 S0 CW 10K OHM SPEED POT FWD (a). Unidirectional Forward CW 10K OHM SPEED POT REV S3 S2 S1 S0 CW FWD REV (c). Bidirectional 10K OHM SPEED POT (b). Unidirectional Reverse Figure 7. Speed Adjust Potentiometer Connections 18

Speed Adjust Potentiometer (-PCM models) Use a 10K ohm, 1/4 W potentiometer for speed control. The motor can operate in one direction (unidirectional) or two directions (bidirectional) depending on how the speed adjust potentiometer is connected to the drive. For unidirectional operation in the foward direction, connect the speed adjust potentiometer as shown in Figure 8(a). For unidirectional operation in the reverse direction, connect the speed adjust potentiometer as shown in Figure 8(b). For bidirectional operation, connect the speed adjust potentiometer as shown in Figure 8(c). The motor does not operate when the potentiometer is in the center position. Turning the potentiometer clockwise (CW) from the center position causes the motor to rotate in the forward direction, while turning the potentiometer counterclockwise (CCW) causes rotation in the reverse direction. 10K OHM SPEED POT -15 +15 COM INPUT 1 CW FWD (a). Unidirectional Forward 10K OHM SPEED POT -15 +15 COM INPUT 1 CW FWD REV 10K OHM SPEED POT -15 +15 COM INPUT 1 CW REV (c). Bidirectional (b). Unidirectional Reverse Figure 8. -PCM Speed Adjust Potentiometer Connections 19

Analog Input Signal Instead of using a speed adjust potentiometer, the drive may be wired to follow an analog input voltage signal that is isolated from earth ground (Figure 9). Connect the signal common ( ) RB1. Connect the signal input (+) to S2. A potentiometer can be used to scale the analog input voltage. An interface device, such as Minarik Drives model PCM4, may be used to scale and isolate an analog input voltage. An isolated analog input voltage range of -10 to 10 VDC is required to produce an armature voltage range of -90 to 90 VDC with 115 VAC line voltage or -180 to 180 VDC with 230 VAC line voltage. RB1 RB1 (-) Signal Common S3 S2 S1 S0 S2 (+) Signal Reference Figure 9. Analog Input Signal Connections 20

Analog Input Signal (-PCM models) Instead of using a speed adjust potentiometer, the drive may be wired to follow an analog input voltage or current signal that is either isolated or non-isolated from earth ground. Connect the signal common (-) to terminal 7 (COM). If using an input current signal or an input voltage signal of 0 to ± 25 VDC or less, connect the signal reference (+) to terminal 8 (INPUT 1), or if using an input voltage signal greater than 0 to ±25 VDC, connect the signal reference (+) to terminal 9 (INPUT 2). Refer to Figures 15 and 16 on page 29 for switch SW501 settings and location. If using an input current signal, the signal may be used to determine motor speed only. To change direction, a direction switch must be used. POLARITY REVERSAL SWITCH PREWIRED TO RGA BOTTOM BOARD Figure 10. -PCM Analog Input Signal Connections 21

+15 and -15! WARNING! Do not short the +15 and -15 terminals for any reason. Shorting these terminals will damage the drive. RG500 series drives can supply a regulated +15 and -15 VDC signal (each sourcing 15 ma maximum) with respect to RB1, to isolated, external devices. See Figure 10 for voltage supply terminal locations. Enable, Regen Brake, and Inhibit See the Starting and Stopping Methods section on pages 32 through 36 for a detailed description of the Enable, Inhibit, and Regen Braking (RB1, RB2) connections. Direction Switch For non -PCM models, refer to Figures 22 and 23 on page 50. For -PCM models, a single-pole, single-throw switch can be used as a reversal switch. Connect the switch to terminals COM and DIR. Close the switch to reverse the motor. Open the switch to return the motor back to it s original direction. Refer to Figure 12 on page 25. 22

Tachogenerator Feedback Using tachogenerator feedback improves speed regulation from approximately 1% of motor base speed to approximately 0.1% of motor base speed. Use tachogenerators rated from 7 VDC per 1000 RPM to 50 VDC per 1000 RPM. Connect the tachogenerator to terminals T1 and T2 of terminal block TB502. The polarity is positive (+) for T1 and negative (-) for T2 when the motor is running in the forward direction. Place SW504 in the TACH position. See Figures 11, 12 and 13 on pages 24, 25 and 26 for tachogenerator connections. The TACH trim pot must be adjusted prior to operating with tachogenerator feedback. Refer to the Calibration section for instructions on calibrating the TACH trim pot. 23

R502 R503 C507 C510 C506 ARMATURE FEEDBACK 90 180 ARM TACH SCR505 SCR506 SCR507 SCR508 C509 R504 R505 R506 C508 SCR501 SCR502 SCR503 SCR504 C501 FU501 FU502 FAST ACTING FUSES ONLY L1 L2 SW502 SW501 SW503 T504 T503 T502 T501 R501 T505 115 230 230 115 SW504 SO502 INH-RUN SO501 C502 C503 TB501 INHIBIT IC501 IC502 P501 P502 P503 P504 P505 P506 P507 P508 P509 MIN SPD FWD TQ REV TQ IR COMP MAX SPD FWD ACC REV ACC DB TACH S3 S2 S1 S0 RB1 RB2-15 +15 T1 T2 NOTE: DO NOT make any connections to T1 and T2 unless using a tachogenerator. REGENERATIVE BRAKE SWITCH (OPTIONAL) TACHOGENERATOR (OPTIONAL) C504 TB502 C505 L1 L2 230V L2 115V GND F1 F2 A2 A1 230 VAC 115 VAC A ARMATURE OUTPUT POWER SWITCH LINE VOLTAGE FIELD OUTPUT For shunt wound motors only. See field output section for connections. Figure 11. RG500UA and RG510UA Connections 24

POLARITY REVERSAL SWITCH MIN SPD FWD TQ REV TQ IR COMP MAX SPD FWD ACC REV ACC DB TACH PREWIRED TO BOTTOM BOARD S0 R501 S2 SCR501 FU501 FU502 FAST ACTING FUSES ONLY L1 L2 SW502 SW501 115 230 230 115 T505 C502 C503 TB501 IC501 IC502 S3 S2 S1 S0 RB1 RB2-15 +15 T1 T2 REGENERATIVE BRAKE SWITCH (OPTIONAL) TACHOGENERATOR (OPTIONAL) C504 TB502 C505 L1 L2 230V L2 115V GND F1 F2 A2 A1 230 VAC 115 VAC A ARMATURE OUTPUT NOTE: DO NOT make any connections to T1 and T2 unless using a tachogenerator. POWER SWITCH LINE VOLTAGE FIELD OUTPUT For shunt wound motors only. See field output section for connections. 25 Figure 12. RG500UA-PCM and RG510UA-PCM Connections

C501 L2 230V SW501 L2 R502 SW503 T504 T503 T502 T501 R503 ARMATURE FEEDBACK 90 180 ARM TACH SW504 SO502 C502 C503 TB501 IC501 IC502 TB502 C505 RG500 Series C507 C506 CR502 SCR503 SCR504 SCR505 SCR506 SCR507 SCR508 C509 R504 R505 R506 C508 INH-RUN SO501 INHIBIT P501 P502 P503 P504 P505 P506 P507 P508 P509 MIN SPD FWD TQ REV TQ IR COMP MAX SPD FWD ACC REV ACC DB TACH C510 NOTE: DO NOT make any connections to T1 and T2 unless using a tachogenerator. TACHOGENERATOR (OPTIONAL) 230 VAC 115 VAC 1 2 3 C504 L1 115 230 115V GND F1 F2 A2 A1 S3 S2 S1 S0 RB1 RB2-15 +15 T1 T2 PREWIRED TO POT AND SWITCH ON COVER A ARMATURE OUTPUT FIELD OUTPUT For shunt wound motors only. See field output section for connections. Figure 13. RG500A and RG510A Connections 26

Section 5. Operation! WARNING! Change voltage switch settings only when the drive is disconnected from AC line voltage. Make sure both switches are set to their correct position. If the switches are improperly set to a lower voltage position, the motor will not run at full voltage and may cause damage to the transformer. If the switches are improperly set to a higher voltage position, the motor will overspeed, which may cause motor damage, or result in bodily injury or loss of life. Dangerous voltages exist on the drive when it is powered. BE ALERT. High voltages can cause serious or fatal injury. For your safety, use personal protective equipment (PPE) when operating this drive. If the motor or drive does not perform as described, disconnect the AC line voltage immediately. Refer to the Troubleshooting section, page 59, for further assistance. Before Applying Power 1. Verify that no foreign conductive material is present on the printed circuit board. 2. Ensure that all switches are properly set. 27

C504 115 230 230 115 S3 S2 S1 S0 RB1 RB2-15 +15 T1 T2 SCR501 SCR502 SCR503 SCR504 INH-RUN SO501 INHIBIT SCR505 SCR506 SCR507 R504 R505 R506 SCR508 P501 P502 P503 P504 P505 P506 P507 P508 P509 MIN SPD FWD TQ REV TQ IR COMP MAX SPD FWD ACC REV ACC DB TACH C509 C508 C507 C506 C510 RG500 Series Select Switches Input Voltage Select (SW501, SW502) Set the input voltage select switches SW501 and SW502 to either 115 or 230 to match the AC line voltage. See Figure 14. Armature Voltage Select (SW503) Set the armature voltage select switch SW503 to either 90 or 180 to match the maximum armature voltage. See Figure 14. Feedback Select (SW504) Set the feedback select switch SW504 to either ARM for armature feedback or TACH for tachogenerator feedback. See Figure 14. L1 L2 230V FAST ACTING FUSES ONLY L1 L2 FU501 FU502 C501 Armature Voltage Select (SW503) L2 115V GND F1 F2 A2 A1 TB502 C505 TB501 SW501 Input Voltage Select (SW501, SW502) C503 IC502 SW502 C502 IC501 T505 R501 SO502 T501 T502 T503 Feedback Select (SW504) T504 SW503 SW504 ARMATURE FEEDBACK 90 180 ARM TACH R502 R503 Figure 14. Select Switches 28

Signal Select (SW501) (-PCM models) Set the signal switch SW501 based on the type of input signal to be used. See Figure 15 for settings and Figure 16 for location. INPUT SIGNAL LEVEL VDC 1-5 ma 4-20 ma 10-50 ma Figure 15. SW501 Settings Input Voltage Select (SW502) (-PCM models) Set the input voltage select switch SW502 to either 115 or 230 to match the AC line voltage. See Figure 16. Signal Select (SW501) Input Voltage Select (SW502) Figure 16. -PCM Select Switches 29

Startup RG500UA, RG500UA-PCM, RG510UA, and RG510UA-PCM 1. Turn the speed adjust potentiometer full counterclockwise (CCW) or set the input voltage or current signal to minimum. 2. Apply AC line voltage. 3. Slowly advance the speed adjust potentiometer clockwise (CW) or increase the input voltage or current signal. The motor slowly accelerates as the potentiometer is turned CW or as the input voltage or current signal is increased. Continue until the desired speed is reached. 4. Remove AC line voltage from the drive to coast the motor to a stop. 30

RG500A and RG510A 1. Set the FORWARD/BRAKE/REVERSE switch to the BRAKE position. 2. Turn the speed adjust potentiometer to 0 (full CCW) or set the input voltage signal to minimum. 3. Set the POWER switch to the ON position. 4. Set the FORWARD/BRAKE/REVERSE switch to the desired direction of rotation. 5. Slowly advance the speed adjust potentiometer clockwise (CW) or increase the input voltage signal. The motor slowly accelerates as the potentiometer is turned CW or as the input voltage signal is increased. Continue until the desired speed is reached. 6. To brake the motor to a stop, set the FORWARD/BRAKE/ REVERSE switch to the BRAKE position. To coast the motor to a stop, set the POWER switch to the O (OFF) position. 7. To reverse direction, set the FOWARD/BRAKE/REVERSE switch to the desired direction. 8. Set the POWER switch to the OFF position. 31

Starting and Stopping Methods! WARNING! Regenerative braking, coasting to a stop, or decelerating to minimum speed is recommended for frequent starts and stops. Do not use any of these methods for emergency stopping. They may not stop a drive that is malfunctioning. Removing AC line power (both lines) is the only acceptable method for emergency stopping. For this reason, Minarik Drives strongly recommends installing an emergency stop switch on both AC line inputs (see Figures 11 and 12 on pages 23 and 24). Frequent starting and stopping can produce high torque. This may cause damage to motors, especially gearmotors that are not properly sized for the application. Automatic Restart Upon Power Restoration All drives automatically run to set speed when power is applied, the drive is enabled, and the inhibit is open. Line Starting and Stopping Line starting and stopping (applying and removing AC line voltage) is recommended for infrequent starting and stopping of a drive only. When AC line voltage is applied to the drive, the motor accelerates to the speed set by the speed adjust potentiometer or analog signal. When AC line voltage is removed, the motor coasts to a stop. 32

C504 INH-RUN SO501 INHIBIT SCR505 SCR506 SCR507 R504 R505 R506 SCR508 P501 P502 P503 P504 P505 P506 P507 P508 P509 MIN SPD FWD TQ REV TQ IR COMP MAX SPD FWD ACC REV ACC DB TACH C509 C508 C507 C506 C510 RG500 Series Regenerative Brake to Zero Speed (INHIBIT Terminals) Short the INHIBIT terminals to regeneratively brake the motor to zero speed (see Figure 17). The inhibit bypasses both the MIN SPD trim pot and the deceleration rate set by the FWD ACC or REV ACC trim pots. Open the INHIBIT terminals to accelerate the motor to set speed. Twist inhibit wires and separate them from power-carrying wires or sources of electrical noise. Use shielded cable if the inhibit wires are longer than 18 inches (46 cm). If shielded cable is used, ground only one end of the shield to earth ground. Do not ground both ends of the shield. Minarik Drives offers two accessory plug harnesses for connecting to the INHIBIT terminals: part number 201-0024 [plug with 18 in. (46 cm) leads]; and part number 201-0079 [plug with 36 in. (91 cm) leads]. L1 L2 230V FAST ACTING FUSES ONLY L1 L2 FU501 FU502 SCR501 SCR502 SCR503 SCR504 C501 L2 115V GND F1 F2 A2 A1 TB502 C505 TB501 SW501 115 230 230 115 SW502 C502 IC501 IC502 C503 T501 R501 SO502 T505 SW503 SW504 T504 T503 T502 Inhibit Terminals ARMATURE FEEDBACK 90 180 ARM TACH R502 R503 S3 S2 S1 S0 RB1 RB2-15 +15 T1 T2 Figure 17. Inhibit Terminals 33

Regenerative Decel to Zero Speed (RB1 and RB2 Terminals) Short the RB1 and RB2 terminals to regeneratively brake the motor to zero speed. See Figures 11, 12 and 13 on pages 24, 25 and 26. The RB1 and RB2 circuit follows the deceleration rate set by the FWD ACC and REV ACC trim pots. Open the RB1 and RB2 terminals to accelerate the motor to set speed. 34

Regenerative Decel to Minimum Speed The switch shown in Figure 18 may be used to decelerate a motor to a minimum speed. Closing the switch between S0 and S2 decelerates the motor from set speed to a minimum speed determined by the MIN SPD trim pot setting. If the MIN SPD trim pot is set full CCW, the motor decelerates to zero speed. The REV ACC or FWD ACC trim pot setting determines the rate at which the drive decelerates, depending on the direction of deceleration. By opening the switch, the motor accelerates to set speed. S1 or S3 S2 S0 CW 10K OHM SPEED ADJUST POTENTIOMETER RUN DECEL TO MIN SPEED Figure 18. Run/Decelerate to Minimum Speed Switch 35

L2 S 3 S 2 1 1 5 2 3 0 2 3 0 1 1 5 S 1 S 0 R B 1 R B 2-1 5 + 1 5 T 1 T 2 IN H - R U N S O 5 0 1 IN H IB IT RG500 Series Coast to Zero Speed (INHIBIT-RUN) To coast the motor to a stop, without removing power to the drive, jumper INHIBIT-RUN terminals 1 and 2. To restart the motor, jumper INHIBIT-RUN terminals 2 and 3. A single-pole, double-throw switch may be used as a COAST/RUN switch. Each drive is assembled with INHIBIT- RUN terminals 2 and 3 jumpered. These terminals must be connected for the motor to run. See Figure 19. Minarik Drives offers an accessory plug harness for connecting to the INHIBIT-RUN terminals: part number 201-0197 [plug with 18 in. (46 cm) leads]. C O CA OAST S T T O TOS T SO TOP P RUN R U N C O A S T / R U N S W I T C H 1 2 3 INI N H - R RU N U N S O S0502 230V R 501 F U 504 S W 502 S W 501 L2 115 V G N D F 1 T 505 1 2 3 S O 502 F 2 C 502 C 503 T B 501 A 2 A 1 IC 501 IC 502 T B 502 C 505 Figure 19. Inhibit-Run Terminal Location and Run/Coast Switch 36

Section 6. Calibration! WARNING! Dangerous voltages exist on the drive when it is powered. When possible, disconnect the voltage input from the drive before adjusting the trim pots. If the trim pots must be adjusted with power applied, use insulated tools and the appropriate personal protection equipment. BE ALERT. High voltages can cause serious or fatal injury. RG500 series drives have user-adjustable trim pots. Each drive is factory calibrated to its maximum current rating. Readjust the calibration trim pot settings to accommodate lower current rated motors. All adjustments increase with CW rotation and decrease with CCW rotation. Use a non-metallic screwdriver for calibration. Each trim pot is identified on the printed circuit board. 37

Minimum Speed (MIN SPD) The MIN SPD setting determines the minimum motor speed in unidirectional operation when the speed adjust potentiometer or input voltage signal is set for minimum speed. To calibrate the MIN SPD: 1. Set the speed adjust potentiometer or input voltage signal for minimum speed. 2. Adjust MIN SPD until the desired minimum speed is reached or is just at the threshold of rotation. Maximum Speed (MAX SPD) The MAX SPD setting determines the maximum motor speed in the forward and reverse direction when the speed adjust potentiometer or input voltage signal is set for maximum speed. To calibrate MAX SPD: 1. Set the speed adjust potentiometer or input voltage signal for maximum speed. 2. Adjust MAX SPD until the desired maximum speed is reached. Note: Check the MIN SPD and MAX SPD adjustments after recalibrating to verify that the motor runs at the desired minimum and maximum speed. Note: If using models RG500UA-PCM or RG510UA-PCM, set the MIN SPD to full CCW and the MAX SPD to full CW. Use the MIN OUT and MAX SPD trim pots located on the top board for minimum and maximum speed calibration. See page 45 for calibration of those trim pots. 38

Forward Torque (FWD TQ)! WARNING! FWD TQ should be set to 150% of motor nameplate current rating. Continuous operation beyond this rating may damage the motor. If you intend to operate beyond the rating, contact your Minarik Drives representative for assistance. The FWD TQ setting determines the maximum torque for accelerating and driving the motor in the forward direction. It also sets the maximum torque for decelerating the motor in the reverse direction. To calibrate FWD TQ, refer to the recommended FWD TQ settings in Figure 20 (page 42) or use the following procedure: 1. With the power disconnected from the drive, connect a DC ammeter in series with the armature. 2. Set the FWD TQ trim pot to minimum (full CCW). 3. Set the speed adjust potentiometer or input voltage or current signal to maximum speed. 4. Carefully lock the motor armature. Be sure that the motor is firmly mounted. 5. Apply line power. The motor should be stopped. 6. Slowly adjust the FWD TQ trim pot CW until the armature current is 150% of motor rated armature current. 7. Set the speed adjust potentiometer CCW or decrease the input voltage or current signal to minimum speed. 8. Remove line power. 9. Remove the stall from the motor. 10. Remove the ammeter in series with the motor armature if it is no longer needed. 39

Reverse Torque (REV TQ)! WARNING! REV TQ should be set to 150% of motor nameplate current rating. Continuous operation beyond this rating may damage the motor. If you intend to operate beyond the rating, contact your Minarik Drives representative for assistance. The REV TQ setting determines the maximum torque for decelerating the motor in the forward direction. It also sets the maximum torque for accelerating and driving the motor in the reverse direction. To calibrate REV TQ, refer to the recommended REV TQ settings in Figure 20 (page 42) or use the following procedure: 1. With the power disconnected from the drive, connect a DC ammeter in series with the armature. 2. Set the REV TQ trim pot to minimum (full CCW). 3. Set the speed adjust potentiometer or input voltage or current signal to maximum speed. 4. Carefully lock the motor armature. Be sure that the motor is firmly mounted. 5. Apply line power. The motor should be stopped. 6. Slowly adjust the REV TQ trim pot CW until the armature current is 150% of motor rated armature current. 7. Set the speed adjust potentiometer CCW or decrease the input voltage or current signal to minimum speed. 8. Remove line power. 9. Remove the stall from the motor. 10. Remove the ammeter in series with the motor armature if it is no longer needed. 40

IR Compensation (IR COMP) The IR COMP setting determines the degree to which motor speed is held constant as the motor load changes. Use the following procedure to recalibrate the IR COMP setting: 1. Set the IR COMP trim pot to minimum (full CCW). 2. Increase the speed adjust potentiometer or input voltage or current signal until the motor runs at midspeed without load (for example, 900 RPM for an 1800 RPM motor). A handheld tachometer may be used to measure motor speed. 3. Load the motor armature to its full load armature current rating.the motor should slow down. 4. While keeping the load on the motor, rotate the IR COMP trim pot until the motor runs at the speed measured in step 2. If the motor oscillates (overcompensation), the IR COMP trim pot may be set too high (CW). Turn the IR COMP trim pot CCW to stabilize the motor. 5. Unload the motor. See Figure 20 on page 42 for recommended IR COMP settings. 41

RG500 Models FWD D TQ REV TQ IR COMP 1 HP 90 VDC 10 ADC FWD D TQ REV TQ TQ IR COMP 2 HP 180 VDC 9.2 ADC FWD D TQ REV TQ IR COMP 3/4 HP 90 VDC 7.6 ADC FWD D TQ REV TQ TQ IR COMP 1 HP 180 VDC 5 ADC FWD TQ REV TQ IR COMP 1/2 HP 90 VDC 5 ADC FWD D TQ REV TQ TQ IR COMP 3/4 HP 180 VDC 3.8 ADC FWD D TQ REV TQ IR COMP 1/4 HP 90 VDC 2.7 ADC FWD D TQ REV TQ TQ IR COMP 1/2 HP 180 VDC 2.5 ADC RG510 Models 1/8 HP 90 VDC 1.3 ADC FWD D TQ REV TQ IR COMP FWD D TQ REV TQ IR COMP 1/4 HP 180 VDC 1.4 ADC 1/10 HP 90 VDC 1.1 ADC FWD D TQ REV TQ IR COMP FWD D TQ REV TQ IR COMP 1/8 HP 180 VDC 0.67 ADC FWD D TQ REV TQ IR COMP 1/20 HP 90 VDC 0.56 ADC Figure 20. Recommended FWD TQ, REV TQ, and IR COMP settings (actual settings may vary with each application) 42

Forward Acceleration (FWD ACC) The FWD ACC setting determines the time the motor takes to ramp to a higher speed in the forward direction or to a lower speed in the reverse direction. See Specifications on page 2 for approximate acceleration times. ACCEL is factory set for the fastest acceleration time (full CCW). Turn the FWD ACC trim pot CW to increase the foward acceleration time and CCW to decrease the foward acceleration time. Reverse Acceleration (REV ACC) The REV ACC setting determines the time the motor takes to ramp to a lower speed in the forward direction or to a higher speed in the reverse direction. See Specifications on page 2 for approximate acceleration times. REV ACC is factory set for the fastest acceleration time (full CCW). Turn the REV ACC trim pot CW to increase the reverse acceleration time and CCW to decrease the reverse acceleration time 43

Deadband (DB) The DB setting determines the time that will elapse between the application of current in one direction before current is applied in the opposite direction. The DB affects the resistance that a motor has to changes in the shaft position at zero speed. It does this by applying an AC voltage to the motor armature. The deadband is factory calibrated to approximately 3/4 of a turn position for 60 Hz AC line operation. Recalibrate the trim pot to approximately the 1/4 of a turn position for 50 Hz AC line operation. If you hear motor noise (humming), the deadband might be set too high. Turn the DB trim pot CCW until the motor noise ceases. 50 Hz Applications 60 Hz Applications DB DB Figure 21. Deadband settings 44

Tachogenerator (TACH)! WARNING! Calibrate the TACH setting only when a tachogenerator is used. The TACH setting, like IR COMP setting, determines the degree to which motor speed is held constant as the motor load changes. To calibrate the TACH trim pot: 1. Connect the tachogenerator to T1 and T2. The polarity is positive (+) for T1 and negative (-) for T2 when the motor is running in the forward direction. 2. Set the feedback select switch SW504 to ARM for armature feedback. 3. Set the speed adjust potentiometer or input voltage or current signal to maximum speed. Measure the armature voltage across A1 and A2 using a voltmeter. 4. Set the speed adjust potentiometer or input voltage or current signal to zero speed. 5. Set SW504 to TACH for tachogenerator feedback. 6. Set the IR COMP trim pot to full CCW. 7. Set the TACH trim pot to full CW. 8. Set the speed adjust potentiometer or input voltage or current signal to maximum speed. 9. Adjust the TACH trim pot until the armature voltage is the same value as the voltage measured in step 3. Check that the TACH is properly calibrated. The motor should run at the same set speed when SW504 is set to either armature or tachogenerator feedback. 45

Minimum Speed (MIN OUT), Maximum Speed (MAX OUT) & Signal Input Adjust (-PCM models) The following minimum and maximum values should be known. INmin - Minimum analog input signal. INmax - Maximum analog input signal. OUTmin - Minimum analog output signal. OUTmax - Maximum analog output signal. INmin and INmax is the voltage applied across terminals 7(COM) and 8 (INPUT 1) or 9 (INPUT 2). OUTmin and OUTmax is the voltage across terminals 1 (OUT 1) and 2 (OUT 2) that connect to the lower board. Calibration Procedure 1. Ensure that switch SW501 on the -PCM board is properly set. See page 29 for switch settings. 2. Connect (but do not power) the analog input signal as follows. - Connect the signal negative (-) to terminal 7 (COM). - For a current signal or a 0 - ± 25 VDC voltage signal, connect the - signal positive (+) to terminal 8 (INPUT 1). - For a 0 - ± 250 VDC voltage signal, connect the signal positive (+) to - terminal 9 (INPUT 2). 46

3. Calibrate the regenerative drive s MIN SPD trim pot full CCW and the MAX SPD trim pot full CW. 4. Apply AC line voltage and the analog input signal. 5. Set the input signal to INmin. 6. Adjust the MIN OUT trim pot (P503) so that the output voltage is OUTmin. 7. Set the analog input signal to INmax. 8. Calculate the test point voltage, V tp ; INmax * m V tp = where m = 2 OUTmax - OUTmin INmax - INmin 9. Adjust the SIGNAL INPUT ADJ trim pot (P501) so that the voltage between terminals 7 (COM) and 10 (TP) is V tp. 10. Adjust the MAX OUT trim pot (P502) so that the voltage output signal is OUTmax. 11. Repeat steps 4, 5, 6, 7, 9, and 10 using the same values. 47

Section 7.Application Notes Direction Switch For a Forward/Reverse switch, use a single-pole, two-position switch with a single speed adjust potentiometer to regeneratively reverse the motor (Figure 22). If a Forward/Stop/Reverse switch is desired, use a single-pole, three-position switch (Figure 23). The MIN SPD setting is in effect for either direction. S0 S1 S2 S3 FWD 10K OHM SPEED ADJUST POTENTIOMETER CW REV Figure 22. Forward-Reverse Switch S0 S1 S2 S3 STOP FWD 10K OHM SPEED ADJUST POTENTIOMETER CW REV Figure 23. Forward-Stop-Reverse Switch. 48

Multiple Fixed Speeds Replace the speed adjust potentiometer with a series of resistors with a total series resistance of 10K ohms (Figure 24). Add a single pole, multiposition switch with the correct number of positions for the desired number of fixed speeds. R1 S1 or S3 S2 S0 R2 R3 TOTAL SERIES RESISTANCE 10K OHMS R4 Figure 24. Multiple Fixed Speeds 49

Adjustable Speeds Using Potentiometers In Series Replace the speed adjust potentiometer with a single pole, multiposition switch, and two or more potentiometers in series with a total series resistance of 10K ohms. Figure 25 shows a connection for high and low speed adjust potentiometers. S1 CW S2 HIGH SPEED LOW SPEED 5K OHM CW S0 5K OHM Figure 25. Adjustable Speeds Using Potentiometers In Series 50

Independent Adjustable Speeds Replace the speed adjust potentiometer with a single pole, multiposition switch, and two or more potentiometers in parallel, with a total parallel resistance of 10K ohms. Figure 26 shows the connection of two independent speed adjust potentiometers that can be mounted at two separate operating stations. S0 SPEED 2 CW CW S2 S1 or S3 SPEED 1 20K OHM 20K OHM Figure 26. Independent Adjustable Speeds 51

Independent Adjustable Forward and Reverse Speeds Replace the speed adjust potentiometer with a single pole, multi-position switch, and two or more potentiometers in parallel, with a total parallel resistance of 10K ohms. Figures 27 and 28 show the connection of two independent forward and reverse speed adjust potentiometers that can be mounted at two separate operating stations. S3 S2 S1 S0 FWD REV CW REV 10K OHM CW FWD 10K OHM Figure 27. Independent Adjustable Forward and Reverse Speeds S3 S2 S1 S0 FWD REV STOP CW REV 10K OHM CW FWD 10K OHM Figure 28. Independent Adjustable Forward and Reverse Speeds with Stop 52

RUN/JOG Switch - Inhibit Connection Use a single pole, two position switch for the RUN/JOG switch, and a single pole, normally closed, momentary operated pushbutton for the JOG pushbutton. Connect the RUN/JOG switch and JOG pushbutton to the inhibit terminals as shown in Figure 29. The motor coasts to a stop when the RUN/JOG switch is set to JOG. Press the JOG pushbutton to jog the motor. Return the RUN/JOG switch to RUN for normal operation. RUN JOG PUSHBUTTON INHIBIT JOG Figure 29. RUN/JOG Switch - Inhibit Connection 53

RUN/JOG Switch - Potentiometer Connection Connect the RUN/JOG switch and the JOG pushbutton as shown in Figure 30. When the RUN/JOG switch is set to JOG, the motor decelerates to zero speed. Press the JOG pushbutton to jog the motor. Return the RUN/ JOG switch to RUN for normal operation. S1 or S3 S2 S0 CW 10K OHM SPEED ADJUST POTENTIOMETER RUN JOG JOG PUSHBUTTON Figure 30. RUN/JOG Switch - Speed Adjust Potentiometer Connection 54

Leader-Follower Application In this application, use a PCM4 to monitor the speed of the leader motor (Figure 31). The PCM4 isolates the leader motor from the follower drive, and outputs a voltage proportional to the leader motor armature voltage. The follower drive uses this voltage reference to set the speed of the follower motor. An optional ratio potentiometer may be used to scale the PCM4 output voltage. Leader Drive A1 A2 MOTOR 9 (+) (+) 2 8 PCM4 (-) 1 7 (-) TB502 TB501 10K Ohm (optional) S2 S0 Follower Drive Figure 31. Leader-Follower Application 55

Single Speed Potentiometer Control Of Multiple Drives Multiple drives can be controlled with a single speed adjust potentiometer using a USIM-8 at the input of each drive to provide isolation (Figure 32). Optional ratio potentiometers can be used to scale the USIM-8 output voltage, allowing independent control of each drive. 10K Ohms S3 S2 S1 + 1 - ratio pot A (optional) 10K Ohms S2 S0 Drive A A1 A2 Mot o r A + 2 - ratio pot B (optional) 10K Ohms S2 S0 Drive B A1 A2 Mot o r B ISO101-8 + 8 - ratio pot H (optional) 10K Ohms S2 S0 Drive H A1 A2 Mot o r H Figure 32. Single Speed Potentiometer Control of Multiple Drives 56

Section 8. Troubleshooting! WARNING! Dangerous voltages exist on the drive when it is powered. When possible, disconnect the drive while troubleshooting. High voltages can cause serious or fatal injury. Before Troubleshooting Perform the following steps before starting any procedure in this section: 1. Disconnect AC line voltage from the drive. 2. Check the drive closely for damaged components. 3. Check that no conductive or other foreign material has become lodged on the printed circuit board. 4. Verify that every connection is correct and in good condition. 5. Verify that there are no short circuits or grounded connections. 6. Check that the drive s rated armature is consistent with the motor ratings. For additional assistance, contact your local Minarik Drives distributor or the factory direct: (800) MINARIK or FAX: (800) 394-6334 57

PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTIONS Line fuse blows. 1. Line fuse is the wrong size. 1. Check that the line fuse is correct for the motor size. 2. Motor cable or armature is shorted to ground. 2. Check motor cable and armature shorts. Line fuse does not blow, but the motor does not run. 3. Nuisance tripping caused by a combination of ambient conditions and high-current spikes (i.e. reversing). 1. Speed adjust potentiometer or speed reference voltage is set to zero speed. 3. Add a blower to cool the drive components; decrease FWD TQ or REV TQ settings, or resize motor and drive for actual load demand, or check for incorrectly aligned mechanical components or jams. See pages 38 and 39 for information on adjusting the FWD TQ and REV TQ trim pots. 1. Increase the speed adjust potentiometer setting or speed reference signal. 2. INHIBIT mode is active. 2. Remove the short from the INHIBIT. 3. S2 is shorted to S0 or RB1. 3. Remove the short. 4. Drive is in current limit. 4. Verify that the motor is not jammed. Increase FWD TQ or REV TQ setting if set too low. See pages 39 and 40. 5. Drive is not receiving AC line voltage. 5. Apply AC line voltage to L1 and L2. 6. Motor is not connected. 6. Connect the motor to A1 and A2. 7. Drive is not enabled 7. Make sure jumper SO502 is set to RUN. 58

PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTIONS Motor runs in the opposite direction (non-reversing drives) 1. Motor connections to A1 and A2 are reversed. 1. Reverse connections to A1 and A2. Motor runs too fast. Motor will not reach the desired speed. 1. MAX SPD and MIN SPD are set too high. 2. Motor field connections are loose. 1. Calibrate MAX SPD and MIN SPD. See page 38. 2. Check motor field connections. 1. MAX SPD setting is too low. 1. Increase MAX SPD setting. See page 38. 2. IR COMP setting is too low. 2. Increase IR COMP setting. See page 41. 3. Torque setting is too low. 3. Increase FWD TQ or REV TQ setting. See pages 39 and 40. 4. Motor is overloaded. 4. Check motor load. Resize the motor and drive if necessary. Motor pulsates or surges under load. 1. IR COMP is set too high. 1. Adjust the IR COMP setting slightly CCW until the motor speed stabilizes. See page 41. 2. Motor bouncing in and out of current limit. 2. Make sure motor is not unddersized for load; adjust FWD TQ or REV TQ trim pot CW. See pages 39 and 40. 59

Section 9. Accessories & Replacement Parts Displays Closed Loop... DLC600 Open Loop... VT-8 Kits Potentiometer & Connector Pot Kit... 202-0003 Fuse 1.5-5 Amp Fuse Kit... 050-0066 1-8 Amp Fuse Kit with Pico Fuse... 050-0068 3-8 Amp Fuse Kit with Pico Fuse... 050-0069 5-15 Amp Fuse Kit... 050-0071 1-20 Amp Fuse... 050-0019 Logic Cards Current Sensing 5 Amps... CSC1-5 20 amps... CSC1-20 Isolation Cards -PCM Adder Board Kit... 200-0416 Unidirectional, 8 outputs... USIM-8 60

Notes 61

Unconditional Warranty A. Warranty American Control Electronics warrants that its products will be free from defects in workmanship and material for twelve (12) months or 3000 hours, whichever comes first, from date of manufacture thereof. Within this warranty period, American Control Electronics will repair or replace, at its sole discretion, such products that are returned to American Control Electronics, 14300 De La Tour Drive, South Beloit, Illinois 61080 USA. This warranty applies only to standard catalog products, and does not apply to specials. Any returns of special controls will be evaluated on a case-by-case basis. American Control Electronics is not responsible for removal, installation, or any other incidental expenses incurred in shipping the product to and from the repair point. B. Disclaimer The provisions of Paragraph A are American Control Electronics s sole obligation and exclude all other warranties of merchantability for use, expressed or implied. American Control Electronics further disclaims any responsibility whatsoever to the customer or to any other person for injury to the person or damage or loss of property of value caused by any product that has been subject to misuse, negligence, or accident, or misapplied or modified by unauthorized persons or improperly installed. C. Limitations of Liability In the event of any claim for breach of any of Americn Control Electronics s obligations, whether expressed or implied, and particularly of any other claim or breach of warranty contained in Paragraph A, or of any other warranties, expressed or implied, or claim of liability that might, despite Paragraph B, be decided against American Control Electronics by lawful authority, American Control Electronics shall under no circumstances be liable for any consequential damages, losses, or expenses arising in connection with the use of, or inability to use, American Control Electronics s product for any purpose whatsoever. An adjustment made under warranty does not void the warranty, nor does it imply an extension of the original 12-month warranty period. Products serviced and/or parts replaced on a no-charge basis during the warranty period carry the unexpired portion of the original warranty only. If for any reason any of the foregoing provisions shall be ineffective, American Control Electronics s liability for damages arising out of its manufacture or sale of equipment, or use thereof, whether such liability is based on warranty, contract, negligence, strict liability in tort, or otherwise, shall not in any event exceed the full purchase price of such equipment. Any action against American Control Electronics based upon any liability or obligation arising hereunder or under any law applicable to the sale of equipment or the use thereof, must be commenced within one year after the cause of such action arises. 62

RG500A RG500UA RG500UA-PCM RG510A RG510UA RG510UA-PCM An American Control Electronics Brand www.minarikdrives.com 14300 DE LA TOUR DRIVE SOUTH BELOIT, IL 61080 (800) MINARIK 250-0210 Rev 8