Pressure Independent Flow Controller

Similar documents
protected SkoFlo Valve Model SF15000NMFB OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION PROCEDURES: 1. Install valve so that the flow is in the p

Pressure Independent Flow Controller

Pressure Independent Flow Controller

Pressure Independent Flow Controller. SkoFlo Valve Model SF10000DRS OPERATION AND MAINTENANCE INSTRUCTIONS

Back Pressure Regulator

Back Pressure Regulator

High Turn Down Valve Model SF10000HTD Operations and Maintenance Manual. P.O. BOX 1728 Woodinville, WA USA FAX 425.

High Flow Back Pressure Regulator

Surface CIMV, Low Flow, HTV, Manual

Mark 6127 Series. Pressure Regulators Mark 6127 Series. Pressure Reducing Valves. Valve Features. Operation

OPERATION AND PARTS MANUAL

Step by Step Assembly Instructions

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

Installation, Operation, and Maintenance Manual

2 ½ 12. Model RP 4A Model RPDA 4A Model RPDA2 4A. Installation, Operation, and Maintenance Manual

Model BPS05-Npt-P. Plastic Back Pressure Regulator Valve

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

I N S T R U C T I O N M A N U A L

MAINTENANCE MANUAL. Covering Models: Series (1/4-10 ) S Series (1/4-1 ) Series (3-10 )

MODEL 5540 CONTENTS. Installation, Operation and Maintenance Instructions 1.0 GENERAL

SUPER 30 AUTO EJECT -AE

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

I N S T R U C T I O N M A N U A L

2 ½ 12. Installation, Operation, and Maintenance Manual. Reduced Pressure Principle Backflow Preventer. Reduced Pressure Detector Assembly

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

THE LF-690 SERIES. Operating and Service Manual. Series includes all variants of LF-690/691 and 692

JSRHF Series. Sanitary Valves JSRHF Series High Flow Pressure Reducing Valves. High Flow Bioprocess Clean Gas Pressure Reducing Valves

SERVICING INSTRUCTIONS

I & M MK96 & MK96C. Ideal Installation. Start-Up. Maintenance PROTECT VALVES WITH LINE STRAINERS

PRESSURE REDUCING CONTROL VALVE

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

To ensure proper installation, digital pictures with contact information to before startup.

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INJECTION PUMP

Colt Series C400, C500

Oregon Fuel Injection

JSRLP Series Low Pressure Reducing Valves for Bio-Pharm Gas Applications

INSTALLATION & MAINTENANCE MODEL mm

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B

Wafer and Globe Style Silent Check Valve. Operation, Maintenance and Installation Manual

I N S T R U C T I O N M A N U A L

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Installation, Operation & Maintenance Instructions

Technical Manual MSI Hydraulic Adjustable Choke

I & M Mark 96AA Series

CV Control Valves Installation and Operation Manual

Maintenance Manual. 3-Inch Internal Valve. F660 Series

REPAIR PROCEDURES MANUAL

Maintenance Manual 3-INCH INTERNAL VALVE F660 SERIES

Baumann Sanitary Diaphragm Angle and Inline Control Valve

KAM IAS ISOKINETIC AUTOMATIC SAMPLER. User Manual IASMANUAL-0513 KAM CONTROLS, INC Ann Arbor Drive Houston, Texas USA

Suggested Installation & Operating Instructions for Sidewinder Pumps

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

Suggested Installation & Operating Instructions for Sidewinder Pumps

Type EZR Relief Valve or Backpressure Regulator

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

Type MR108 Direct-Operated Backpressure Regulators

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

Sanitary Design Control Valves V972. Instruction Manual. Installation & Maintenance instructions for W.Arthur Fisher V972 series control valves

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

Installation, Operation and Maintenance Instructions

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

A. Perform a vacuum gauge test to determine engine condition and performance.

Table of Contents. D. Air modules...d-2 AQ2 Air module...d-2 1. Product Overview...D-2 2. Installation...D Operation...D-5 4. Maintenance...

HOUSTON OILFIELD EQUIPMENT 9669 PORT ERROLL RD. HOUSTON, TX PHONE: (713) FAX: (713)

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material

CVS Series H-900, H-1500 and H-2500 Design Valve Bodies

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS .5 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 15

INSTALLATION, OPERATION, & MAINTENANCE MANUAL

Disassembly and Reassembly for CBB-SR (Spring Return) Series Pneumatic Actuators

SERIES 20/20S/20H/ 20HS PILOT

SCREWED BONNET NEEDLE VALVES

MACH 1A HVLP (MACH 1AV HVLP) Automatic Airspray Gun

Check List for Optimal Filter Performance

Model 2000 Control Valves Technical Sales Bulletin

Product Manual. S&S V-100 Ball Valves 2 though 8 Inch Designs. Introduction: Installation:

Fisher CAV4 Control Valve

MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

SAFETY MANUAL READ FIRST!

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

BFMM DC4A SBF EFFECTIVE AUGUST 1, 2016

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

8000 Pump Maintenance

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

1-1/2" DIAPHRAGM PUMP 1:1 Ratio (metallic) with Cone Checks

TY-FLO 3 Piece Ball Valves

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Transcription:

protected Pressure Independent Flow Controller SkoFlo Valve Model SF10000NMFA OPERATION AND MAINTENANCE INSTRUCTIONS

protected SkoFlo Valve Model SF10000NMFA OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION PROCEDURES: 1. Install valve so that the flow is in the proper direction. The "IN" connection and the "OUT" connection are MP20000 connections for 3/4" tubing, and are marked respectively. 2. Install an inline filter in the system. Generally, this is located upstream of the pump. Clean chemical and proper filtering is very important. A 200 micron size filter is recommended. START UP PROCEDURES: 1. Open the supply isolation valve to the flow controller slowly. 2. Turn the rate adjustment handle until you are at the desired flow rate. 3. The flow controller is now set and further adjustments are not required. r:\msoffice\excel\e-mail\o_manuals\skoflo sf15000nmfa\sf15000nmfa-manual-a1 Page 2 of 13

Seat PRINCIPLE OF OPERATION P 2 P 3 OUT CHAMBER 2 P 2 Piston Pin Springs Valve P 1 IN Rate Adjustment Handle Adjustable Cv Section CHAMBER 1 P 1 CHAMBER 3 P 1 The SkoFlo valve is a pressure independent flow control valve used in the petroleum industry to accurately inject chemicals. The valve consists of a body, a base plate that is bolted to the body, and a flow rate adjustment handle. The principle of operation of the Model SF10000NMF SkoFlo valve is that it internally maintains a constant differential pressure across an adjustable Cv section, thus resulting in a constant flow through that Cv section. The piston/spring assembly utilizes system pressure to adjust the internal pin and seat Cv section, which then sets a constant differential pressure across the adjustable Cv section, thus maintaining a constant flow. Flow rate changes through the valve can only be made by adjusting the rate adjustment handle. Fluid enters the valve inlet at pressure P 1 and flows into chamber 1. It then flows through the adjustable Cv section into chamber 2 where the piston and springs are located. These springs put a force against the piston based on how much the springs are deflected. The spring force against the piston is set by the differential pressure between P 1 in chamber 3 and P 2 in chamber 2. This pressure balance establishes the pressure P 2 in chamber 2 at a fixed differential from P 1. Flow then exits the valve at pressure P 3 after passing through the seat. The flow through the seat is held back by the pin that mates with the seat. As the pressure in chamber 2 changes, either as a result of a change in P 1 or a change in P 3, the pin moves in relation to the seat and controls pressure P 2. As soon as equilibrium flow through the valve is established, the flow rate will remain constant even when pressures upstream and/or downstream of the valve change. r:\msoffice\excel\e-mail\o_manuals\skoflo sf15000nmfa\sf15000nmfa-manual-a1 Page 3 of 13

ADJUSTMENT AND CALIBRATION: CHEMICAL SUPPLY (AS AN EXAMPLE SAY 4500 PSIG / 310 BAR) - MUST BE AT LEAST 200 PSI / 14 BAR HIGHER THAN PRESSURE OF THE CHEMICAL TO PROCESS CHEMICAL INJECTION CONTROL VALVE SF 3-WAY VALVE CHEMICAL TO PROCESS (AS AN EXAMPLE SAY 4200 PSIG / 289 BAR) CHEMICAL TO CALIBRATION BEAKER OR TO CALIBRATION FLOW METER (AS AN EXAMPLE SAY 50 PSIG / 4 BAR) The SkoFlo Valve is a pressure independent flow control valve. Once the valve is set at a desired flow rate, that flow rate is maintained even though the pressure conditions upstream and/or downstream of the valve may change considerably. The standard Multi-Point SkoFlo valve is set by manually adjusting the rate adjustment handle. When the desired flow rate is set, the valve needs no further adjustment, and the valve remains at that fixed flow rate until the rate adjustment handle is turned to a new setting. The flow rate can be set using a flow meter in the line to the process. However, a flow meter in this line must be capable of withstanding the process pressure. This normally limits the availability of this type flow meter. The most common method of calibrating the SkoFlo Valve is with a 3-way valve and a line to a calibration beaker or to a low pressure flow meter. Once the flow rate is set, the 3-way valve is switched to direct the chemical to the process. Since the SkoFlo Valve flows at the set rate independent of the pressure differential across the SkoFlo Valve, the flow rate to the process is the same as the flow rate set using the beaker or flow meter. Overall monitoring of the flows is done by taking inventory of the usage from the supply tank. In the above example, the SkoFlo Valve is set with a differential pressure of 4450 psi / 306 bar across the valve. The flow rate set will remain the same when the chemical is routed to process and the SkoFlo Valve has a differential pressure of 300 psi / 21 bar. Note that the SkoFlo valve should not be operated continuously at differential pressures above 3000 psi / 207 bar. r:\msoffice\excel\e-mail\o_manuals\skoflo sf15000nmfa\sf15000nmfa-manual-a1 Page 4 of 13

OPERATION NOTES AND WARNINGS: 1. The SkoFlo valve has hard seats and is not designed to provide complete "bubble-tight" shut off. Separate isolation valves should be used for shutting off the flow. Overtightening the handle could cause damage to the stem section. If flow rate does not decrease when turning the handle in, see "Trouble Shooting Improper Valve Performance". 2. The model SF10000NMF valve should not be operated at flow rates below 0.2 gpm. Lower rates can cause excessive pressure drops in the stem section. 3. Operating valve with continuous differential pressures above 3000 psi / 207 bar may cause premature internal wear and must be avoided. 4. The SkoFlo Valve is designed for flow in one direction only. Do not flow backwards through the SkoFlo valve. Some internal seals are designed for one direction only and could possibly become dislodged. The valve will not control flow in the reverse direction. Flow Control Industries recommends installation of a check valve in the outlet line from the SkoFlo valve (see "Multi-Point System Sample Schematic") to avoid reverse flow of process fluids into the chemical system. 5. When lifting the SkoFlo valve, lift from the base. Do not lift using the handle as this can damage the handle. MAINTENANCE: 1. Replacing Seals: When replacing valve seals, it is recommended that the Piston Seal Installer Tool (P/N SF15000N-T1) be used. A. Remove SkoFlo valve from system. B. Remove the adjustment handle retainer lock bolt. Remove the retainer lock plate. Unscrew the stem retainer and pull the rate adjustment handle out of the body. C. Pull out the needle trim using a hooked probe or similar devise. Use care to avoid damage to the internal surfaces of the SkoFlo valve. (See Figure I). Figure I r:\msoffice\excel\e-mail\o_manuals\skoflo sf15000nmfa\sf15000nmfa-manual-a1 Page 5 of 13

D. Unscrew and remove the base cap. E. Screw a bolt into the thread on the piston (use handle retainer lock bolt or any M8 bolt) and carefully pull out the piston assembly and the springs. (See Figure II). Figure II F. If replacing the seal on the ceramic seat, remove the snap ring and seat retainer. Use a hooked probe to carefully remove the seat. (See figure III). Figure III G. Lubricate new seat seal with Parker Super Lube or equivalent. Slide seal onto seat holder. Install back up ring on low pressure side of o-ring (toward outlet). Insert the seat into the body by slowly pushing with a tool which will not chip the ceramic seat. Orient seat with largest hole end into the body. Reinstall seat retainer and snap ring. Figure IV r:\msoffice\excel\e-mail\o_manuals\skoflo sf15000nmfa\sf15000nmfa-manual-a1 Page 6 of 13

H. Remove piston cup seal snap ring and cup seal retainer. Remove seal. Lubricate new piston seal with Parker Super Lube or equivalent. Slide seal onto piston (orient seal correctly). Replace cup seal retainer and snap ring. Place piston spring stack into the valve body (orient as shown in attached drawing "Assembly Section / Parts List"). Carefully slide the piston assembly into the valve body. Using the Piston Seal Installer Tool, push seal and piston assembly into body to clear base plate (See Figure V). Figure V I. Lubricate base o-ring with Parker Super Lube or equivalent. Place o-ring into o-ring groove of base. Install back up ring on low pressure side of o-ring. J. Screw base plug into body until just past the edge of the body. Install the base plug lock bolt and torque to maximum 10 foot-pounds (1.4 kg-m). Be careful not to overtighten. K. Install o-rings and backup rings on the needle trim. Locate the backup rings on the low pressure side of the o-rings as shown in Figure VI. Figure VI BACKUP RING r:\msoffice\excel\e-mail\o_manuals\skoflo sf15000nmfa\sf15000nmfa-manual-a1 Page 7 of 13

L. Push needle trim into the body. M. Install o-rings and backup rings on the needle stem. Locate the backup rings as shown in Figure VII. Figure VII BACKUP RING N. Install adjustment handle assembly into the body. Torque the stem retainer to 10-30 foot-pounds (1.4-4 kg-m). Orient the stem retainer so that the retainer lock plate and retainer lock bolt will fit in place. O. Install the retainer lock plate and lock bolt onto the body. Torque the retainer lock bolt to 10 foot-pounds (1.4 kg-m). 2. Replacing Needle Stem Assembly: A. Disassemble and reassemble the SkoFlo valve using new seals as described in the "Replace Seals" section above. 3. Replacing Piston / Pin Assembly: A. Disassemble and reassemble the SkoFlo valve using new seals and piston assembly as described in the "Replace Seals" section above. B. When installing pin holder into piston, hold piston in a manner where the surface finish will not be damaged. Torque pin holder to 100 inch-pounds (1.15 kg-m). r:\msoffice\excel\e-mail\o_manuals\skoflo sf15000nmfa\sf15000nmfa-manual-a1 Page 8 of 13

TROUBLE SHOOTING IMPROPER VALVE PERFORMANCE: SYMPTOM CAUSE REMEDY 1. No Flow Upstream filter is Clean or replace plugged. filter element. Supply valve is shut off. Discharge line is shut off. Open valve slowly. Open valve. 2. Fluctuations in Internal passage in Dismantle the valve flow rates valve body between and clean up the inlet and piston passage. chamber is plugged. Piston Springs are not installed properly. Seat or pin worn or damaged. Supply pressure is not adequate. Install springs in accordance with drawing SF-0738 and Figure V. Replace seat holder or piston assembly. The flow controller requires a minimum of 200 psi (14 bar) differential pressure across the valve for proper operation. (Valves designed for special high flows may require a higher differential pressure). r:\msoffice\excel\e-mail\o_manuals\skoflo sf15000nmfa\sf15000nmfa-manual-a1 Page 9 of 13

LTR A ECN DESCRIPTION INITAL RELEASE DRAWN DATE APPROVED JT 11/01/04 MK CLEARANCE HOLES FOR M8-1.25 (X5) 105.0 TO ARC END (X2) 1.461 MOUNTING HOLES M8-1.25 TAPPED.5 DEEP 5 HOLES THIS SIDE Ø 2.200.612 (X2) 1.855 (X2) 1.327 (X2).826 (X2) 17.4 (X2) R.25 (X2) R.375 (X2) TOP VIEW CUT OUT FOR PANEL MOUNT AUTOCLAVE ENGINEERS 20000 PSI MEDIUM PRESSURE CONNECTION FOR 3/4" TUBING MOUNTING HOLES M12-1.75 TAPPED.5 DEEP 2 PLACES EACH SIDES OUTLET 3.01 INLET 7.92 AUTOCLAVE ENGINEERS 20000 PSI MEDIUM PRESSURE CONNECTION FOR 3/4" TUBING 5.45 1.40 1.40 3.11 6.55 1.47 2.5 2.5 NOTES: 1) DIMENSIONS IN MM (INCHES) 2) STANDARD MATERIALS: BODY: NITRONIC 60 SS SEALS: GRAPHITE / TEFLON EPR (ALT: KALREZ) UNLESS OTHERWISE SPECIFIED DIM. ARE IN INCHES 2 PL. DEC. 3 PL. DEC. ANGLES FRACTIONS ± 1/64 ±.01 ±.005 ± 1 SIGNATURES DRAWN CHECKED ENGRG ISSUED JT DATE 11-01-04 SIZE A SCALE SF10000NMFB OUTLINE DRAWING DWG NO. SF-SK209 REV: A WOODINVILLE, WA NONE SHEET 1 OF 1

Multi-Point System Sample Schematic TANK BACK PRESSURE REGULATOR BPR FILTER PUMP PRV EXP PULSATION DAMPER (EXPANSION COMPENSATOR) Chemical Supply System PRESSURE GAUGE CHEMICAL TO VALVES ISOLATION VALVE FILTER SF SF SF SF CHEMICAL INJECTION CONTROL VALVE 3-WAY VALVE CHECK VALVE TO FLOW METER OR CALIBRATION BEAKER ISOLATION VALVE CHEMICAL OUT TO PROCESS Chemical Injection System Notes: 1. Any number of injection points can be served by a single pump and header system. The only limitation is the flow capability of the pump. 2. Check valve must be installed within 5 feet from the SkoFlo valve. r:\msoffice\excel\service\mp-schem r:\msoffice\excel\e-mail\o&m_manuals\sf5000c-manual-a3 Page 12 of 13

Page 13 of 13 23 27 24 7 32 OUT 22 11 15 29 30 31 16 1 5 MATERIAL LIST - Sko-Flo Valve SF10000NMFA ITEM QTY PART NO. MPR NO DESCRIPTION MATERIALS 1 1 SF15000NMFB-1 20282 BASE PLUG 316LSS 2 1 SF15000NMFB-2 20673 BODY 316LSS 3 1 SF15000NMFA-3A 20693 HANDLE (with set screw) 316SS 4 1 SF15000NMFB-3B 20674 NEEDLE STEM NITRONIC 60 SS 5 1 SF15000NMFA-4 20613 PISTON NITRONIC 60 SS 6 1 SF15000NMFA-5 20617 NEEDLE TRIM NITRONIC 60 SS 7 1 SF15000N-6-XXXL 20275 SEAT CERAMIC 8 1 SF15000NMFA-7 20639 PIN HOLDER 316LSS 9 1 SF15000N-8-XXXL 20638 PIN CERAMIC 10 1 SF15000NMFA-9 71002075 PIN SPRING 304SS 11 15 SF15000NMFA-10 22110 PISTON SPRING 316SS 12 1 SF15000NMFA-11 SEE BELOW O-RING (UPPER TRIM) EPR (KALREZ) 13 1 SF15000-18-XXXL SEE BELOW O-RING (LOWER TRIM) EPR (KALREZ) 14 2 SF5000C-12 SEE BELOW O-RING (STEM) EPR (KALREZ) 15 1 SF15000NMFB-13 71001867 CUP SEAL (PISTON) TEFLON w/ GRAPHITE FIBERS 16 1 SF15000NMFA-16 SEE BELOW O-RING (BASE TO BODY) EPR (KALREZ) 17 1 SF15000NMFA-27 71001932 BACK UP RING FOR ITEM 12 PEEK 18 1 SF15000NMFA-28 71001930 BACK UP RING FOR ITEM 13 PEEK 19 2 SF15000NMFA-29 71001924 BACK UP RING FOR ITEM 14 PEEK 20 1 SF15000NMFA-17 20675 STEM RETAINER 316LSS w/ NI-BR BUSHING 21 1 SF15000NMFB-18 20677 RETAINER LOCK PLATE 316SS 22 1 SF15000NMFB-24 20689 PISTON GUIDE WASHER NITRONIC 60 SS 23 1 SF15000-18-XXXL SEE BELOW O-RING (SEAT) EPR (KALREZ) 24 1 SF15000NMFA-28 71001929 BACK UP RING FOR ITEM 23 PEEK 25 1 SF15000NMFA-31 20528 SEAT RETAINER NITRONIC 60 SS 26 1 SF15000NMFA-32 71002969 SNAP RING (SEAT) 15-7 SS 27 1 SF15000NMFA-22 71002882 RETAINER LOCK BOLT 316SS 28 2 SF15000NMFA-23 71002091 BASE PLUG LOCK BOLT 316SS 29 1 SF15000NMFA-33 20288 CUP SEAL RETAINER NITRONIC 60 SS 30 1 SF15000NMFA-34 71001945 SNAP RING (CUP SEAL) 302SS 31 1 SF15000NMFA-35 71001943 BACK UP RING FOR ITEM 16 PEEK 32 2 BPR15000MF-79 20531 CONNECTION ADAPTER 316SS 33 1 SF15000-25 21353 NAMEPLATE 302SS 34 2 SF15000NMFA-35 SEE BELOW O-RING (AE ADAPTER TO BODYEPR (KALREZ) SF15000NMFA-35, EPDM - 71001829 SEAL KIT, SF10000NMFA -20, EPDM - 22088 NOTES: SF15000NMFA-11, EPDM - 71001766 SF15000NMFA-35, KALREZ - 71001830 SEAL KIT, SF10000NMFA -20, KALREZ - 22089 SF15000NMFA-11, KALREZ - 71001768 SF15000-18-XXXL, EPDM - 71001758 SF15000-18-XXXL, KALREZ - 71001762 SF5000C-12, EPDM - 71001738 SF5000C-12, KALREZ - 71001741 SF15000NMFA-16, EPDM - 71001803 SF15000NMFA-16, KALREZ - 71001805 SF15000-18-XXXL, EPDM - 71001753 SF15000-18-XXXL, KALREZ - 71001756 r:\msoffice\excel\drawings\skoflo\sf-0738 4 8 3 9 20 21 6 14 33 12 13 25 2 28 10 19 17 18 IN 26 SCALE: DATE: SkoFlo Valve Model SF10000NMFA NONE APPROVED BY: DRAWN BY: FJG 2/13/03 REVISED: 11/28/06 SF10000NMFA FLOW CONTROLLER DRAWING NUMBER REV ASSEMBLY SECTION / PARTS LIST SF-0738 A title block=r:\msoffice\excel\drawings\template\a_port)

Our focus is on you our customer and for ISO 9001:2000 compliance we have prepared and request that you take the time to complete this customer satisfaction survey. Company: Contact: Email: Phone: Please rate following categories Highly Highly Dissatisfied N/A Satisfied 1. Product Quality 2. Product Features 3. Reliability 4. After sale support 5. Implementation 6. Delivery Score from 1 (Low ) to 7 (High) (Low) N/A (High) 1 2 3 4 5 6 7 Recommend SkoFlo to friend or colleague. Likely to Purchase Products from SkoFlo Overall quality of relationship with SkoFlo Overall level of satisfaction with SkoFlo Overall level of satisfaction with respect to Product Valve Overall level of satisfaction with respect to product engineering Level of confidence of SkoFlo abilities to provide compliant product Comments: W:\Sales\PDF & EXCEL Drawings\O & M Manuals\SFI Customer Satisfaction Survey.doc Page 1 of 1