better analysis counts

Similar documents
Monitor Chlorine in Crude at Sub-ppm Levels

X-ray Essentials from XOS Proven Performance

Elemental Analysis Advanced

Determination of chlorine/chlorides using MWD- XRF

Are You Prepared For Tier 3 Gasoline Standards? Presented by: Shaun Spiro and Leslie Johnson

ASTM D7039. Sulfur analysis plus a further 21 elements by MWDXRF. Model SS1000-S Sulfur in oil, petrol, diesel All liquids The new S1000 series MWDXRF

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

MESA-7220 Multi-Element Analyzer Using EDXRF Technology

MESA-7220 Measurement of Sulfur, Chlorine and other elements in Petroleum Products Using Mono-chromatic, Polarized EDXRF Analysis

ElvaX Sulfur in Oil analyzer

Low cost EDXRF elemental analyzer

Technical Offer. ViscoPro Measure Viscosity and Temperature on line for continuous process improvement

Process Analyzer. Reid Vapor Pressure Analyzer Model P-700. Credible Solutions for the Oil and Gas Industry

Physical Property Analyzer PPA4100 Series. On-Line RVP Analyzer

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Flash Point Process Analyzer

BARTON 7400 Precision Gas Turbine Flow Meters

TSHR 6000 series TN/TS/TX analyzer

Process Analyzer. Viscosity Index Analyzer Model P-950. Credible Solutions for the Oil and Gas Industry

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

Process Analyzer. Flash Point Analyzer Model P-500. Credible Solutions for the Oil and Gas Industry

STANDARD COMPLIANT VAPOR PRESSURE

Process Analyzer. Cold Filter Plugging Point Process Analyzer CFPP-4. Credible Solutions for the Oil and Gas Industry

Understanding the Si licon Issue

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

SPECTRO XRF Report. SPECTRO iq II

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS

WEBINAR: WDXRF for Petrochemical Analysis More Than a One-Trick Pony. October 31,

Sulfur in Oil Analyzer

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

A unique density, viscosity sensor. High technology brick. Field oriented. For light & medium petroleum products. Related norms

breakthrough versatility

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Oil & Gas Lubrication Systems

On-Line Process Analyzers: Potential Uses and Applications

VariStroke II Electro hydraulic Actuator

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Experience the Difference

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Why measure viscosity in-line?

InfraCal 2 Biodiesel Blend Analyzer

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

White Paper.

Micro Motion 7827 Digital Viscosity Meter

TSHR 7000 series TN-TS-TX analyzer

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Optidew Vision Optical Dew-Point Meter

Remote Process Analysis for Process Analysis and Optimization

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

FasTrak High Capacity Smart Positioner

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

Rosemount 570 Natural Gas Chromatograph

STS SERIES. Enclosed Automated Fuel Maintenance Systems (STS)

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

Smart Products. Maxon Workshop Richard Reyes

THC Heated FID 3-300A

MODEL 106F TEFLON LIQUID FLOW SENSOR

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

New Small Spectrometer Concepts Covering the Ultraviolet to the Mid-Infrared

OPTIMASS 3000 Technical Datasheet

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

S-PRO 3200 GC System for Sulfur Analysis

REVOLUTIONIZE YOUR DENSITY AND CONCENTRATION MEASUREMENT TECHNOLOGY

Jet Fuel Conductivity Analysers & Additive Management systems

X-STREAM Enhanced XEGP - General Purpose Gas Analyzer

Rosemount Analytical Model 500 Process Gas Chromatograph

X-STREAM Enhanced XEGK - Compact Gas Analyzer

Flowmeters. The Satam flowmeter range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and liquid chemicals.

Testing Instrumentation Gasboard 5020 for exhaust gases from petrol or LPG engines

Continuous Duty Torque Measurement. Directly and accurately measures the power of turbomachinery in the Oil, Gas and Petrochemical industries.

WBS 3000 Water Bottom Sensor for fuel oil and chemical storage tanks Installation and Operating Instructions

Prodigy ICP Application Note: # 1039

AVL Particle Measurement System Aviation

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits

Gas analyzers EL3060 The specialists for hazardous areas

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

Contents. Purpose. 1.Measurement Condition. 2.Sample. 3.Standard Requirement. 4.Contents of evaluation. 5.Result. 6.Conclusion. 7.Notices.

State-of-the-art viscosity monitoring

CFPP Process Analyzer

RMF SYSTEMS CONDITION MONITORING CENTER PURE POWER

On-Line NIR Analysis for Blending

1) Analysis of Ultra Low Sulfur in Automotive Fuels According to ASTM D by Sulfur Analyzer Micro-Z ULS (Rigaku Application Note XRF1053)

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

Pressure & Vacuum Measurement. Series 355 & 358. Solutions. Micro-Ion Vacuum gauge and Controller

FPA4 DATASHEET JUNHO 2013

TALYS ASP400 Series A simple and robust process FT-NIR analyzer For refinery and petrochemical industry applications

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

Excellence in gas analyzers since Over 180 years of JY optical experience. The expertise of Horiba combustion technology

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits

flow measurement solutions RIM10 series rotor insertion flowmeters

PRODUCED WATER CANTY INFLOW WATER CUT METER MULTI-PHASE PARTICLE DISTRIBUTION (% OIL IN WATER, % SAND, % GAS) OiW

EDXRF APPLICATION NOTE SULFUR IN BUNKER FUEL # 1230

ASTM D Test to Low ppb. Contact us today for a copy of the Southwest Research Institute D-5453 Fitness for Use Report.

F-2600 SERIES INLINE VORTEX FLOW METER

Transcription:

better analysis counts Application Areas: Upstream desalting, refining, power generation and effluent management. Total chlorine analysis in: - raw and desalted crudes - water and effluent streams - refinery process streams - finished product Features and Benefits: LOD: 0.2 ppm in hydrocarbon matrices (at 300s) 0.3 ppm in aqueous streams (at 300 s) Dynamic range: 0.2 ppm 3000 ppm wt. No consumable liquids or gasses required. No combustion or sample conversion: ensures safe and low maintenance operation. Calibration is linear up to 3000 ppm and one calibration curve runs all hydrocarbon matrices. Direct measurement in ppm wt. Continuous and real time analysis. Options: Multi-stream analysis capability Auto-validation capability. On-Line Chlorine Analysis in Crude, Water and Process Streams Chlorine monitoring in crude oil, process streams, water and effluent streams presents valuable insights in e.g. desalting and refining operations for corrosion management, environmental and process control purposes. The CLORA On-Line Analyzer presents a breakthrough process analytical solution for quantification of total chlorine from 0.2 ppm up to 3000 ppm. CLORA analyzers are not sensitive to sample temperature variation and do not require consumable gasses or liquids. Comprehensive data communications and diagnostics capabilities enable a maximum in uptime. The CLORA On-Line Analyzer is based on the same MWD XRF analytical platform as the CLORA Bench-Top Analyzer.

MWD XRF Monochromatic Wavelength Dispersive X-Ray Fluorescence (MWD XRF) utilizes state-of-theart focusing and monochromating optics to increase excitation intensity and dramatically improve signal-to-background over traditional WD XRF instruments. This enables significantly improved detection limits and precision. A monochromatic and focused primary beam excites the sample and secondary characteristic fluorescence x-rays are emitted from the sample. A second monochromating optic selects the chlorine characteristic x-rays and directs these x-rays to the detector. MWD XRF is a direct measurement technique and does not require consumable gasses or sample conversion. Polychromatic Incident X-rays from tube Optic 1 Optic 2 Precision The MWD XRF analytical platform enables unrivalled precision and accuracy. Long term stability studies indicate highly stable and precise results. Crude 1 Crude 2 Water Average Value 14 ppm 3 ppm 10 ppm Run Time 5 min 5 min 5 min STD DEV 0.4 ppm 0.25 ppm 0.6 ppm Viscosity and Sample Conditioning The CLORA On-Line Analyzer can accept most all crude oil streams with a maximum viscosity limitation of 160 cst at 70 F (1.6 cm 3 /s at 21 C). More viscous materials can be analyzed by increasing sample temperature up to 300 F. A 100 micron self-cleaning by-pass flow style filter assembly or an in-line filter assembly is recommended. The analyzer is insensitive to water content in the crude oil. Aqueous matrices can be tested for chlorine concentration in the same fashion as hydrocarbon matrices. High Viscosity Dynamic Window Module The High Viscosity Dynamic Window Module (HV-DWM) ensures stable and accurate test results independent of sample matrix. The HV-DWM automatically and at preprogrammed intervals positions a new and robust window material in the measurement area. As a result, the measurement is stable and drift caused by contamination build up is eliminated. The HV-DWM uses an x-ray transparent polyimide film allowing stream pressures up to 80 psi (550kPa). While the sample stream continuously flows through the HV-DWM, the sample analysis takes place continuously as well ensuring rapid and highly representative chlorine monitoring of the sample stream. Product Specifications Analytical Platform Dynamic Range Calibration Data Communication Digital Communication Remote Diagnostics Local HMI Ambient Temperature Power Instrument Air - Purge and Valve Dimensions Certifications Flowrate Sample Pressure Sample Temperature Sample Viscosity Sample Filtration Monochromatic WD XRF 0.2-3000 ppm wt. 3-5 point cal curve (depending on range) Analog outputs: 2x 4-20 ma, multiple discrete alarm outputs Modbus RS-232, Modbus RS-485 (Half or Full Duplex), Modbus TCP Optional via TCP/IP or UDP Touch screen display 0-40 C, (32-104 F) 110-240 VAC, 50-60Hz, 750W max. 40-100 psig, (275-690 kpa) 4 scfm max; -40 F (-40 C) dewpoint, oil free, N 2 optional 62 (h) x 34 (w) x 18 (d), 158 cm (h) x 86 cm (w) x 46 cm (d) ATEX Zone 1 Ex d ia [ia] px IIC T4; CE, NEC Class I Div 2 Groups B,C,D T4A Continuous flow through measurement cell at 3-5GPH (11.4-18.9 lph) 30-80 psi (210-550 kpa) Min: > Cloudpoint, Max: 300 F (150 C) Max 160 cst at 70 F, (1.6 cm 2 at 21 C) more viscous material may require sample heating No water removal required, particle filtration to 100 micron better analysis counts 15 Tech Valley Drive East Greenbush, New York 12061, USA 518.880.1500 Fax: 518.880.1510 e-mail: info@xos.com website: www.xos.com XOS (2011) JUNE2011

Sulfur Process Analyzer for Petroleum Fuels Sindie ON LINE KEY FEATURES Total sulfur determination by MWD XRF Dynamic range from 0.6ppm to 3000 ppm Measurement time: 30 seconds to 5 minutes, user programmable No consumables, gases or high temperature processes Extremely low maintenance Modular design for plug-and-go operation Also available in bench-top format USAGE Pipeline terminals: interface cuts and tank contamination prevention Refinery: hydrotreating, hydrofiner and blending processes TOTAL SULFUR ANALYSIS From 0.6 ppm to 3000 ppm in diesel, gasoline, naphtha and kerosene

SINDIE On-Line Sulfur Analysis in Petroleum Fuels The SINDIE On-Line Analyzer is an industrial grade process sulfur analyzer with breakthrough detection capability for monitoring fuel streams as exacting as ultra low sulfur diesel and gasoline. This process analyzer presents the ultimate solution for Pipeline Terminals, where measurement speed, and reliability are essential. The breakthrough Monochromatic Wavelength Dispersive X-Ray Fluorescence technique of the SINDIE On-Line Analyzer offers a Limit Of Detection (LOD) of 0.6 ppm, and a dynamic range of 3000 ppm. This direct and non-destructive measurement technique does not require sample conversion or consumable gases and does not involve high temperature operations. The result: a robust process analyzer with minimal maintenance and unprecedented detection capability and measurement speed. MWD XRF Technology Monochromatic Wavelength Dispersive X-Ray Fluorescence (MWD XRF) analysis provides dramatically improved S/B over conventional XRF techniques, in a compact and simplified on-line configuration. The improved S/B is achieved by eliminating the scattering of bremsstrahlung from the x- ray source. The configuration of a MWD XRF unit is shown in Figure 1. It consists of an x-ray source, a point-focusing optic for excitation, a sample cell, a focusing optic for collection and an x-ray detector. In this system, the first pointfocusing optic captures a narrow bandwidth of x-rays from the source and focuses an intense monochromatic beam in a small spot on the sample cell. The monochromatic primary beam excites the sample and secondary characteristic fluorescence x-rays are emitted. The second collection optic collects only the characteristic sulfur x-rays which are then focused onto the detector. FEATURES AND BENEFITS: Excellent detection capability: LOD: 0.6 ppm Dynamic range from 0.6 ppm 3000 ppm sulfur Continuous monitoring with programmable response times: -10 seconds: ideal for pipeline interface cuts - 5 minutes: for most demanding refinery processes Direct measurement without sample conversion Analysis in ppm (wt) No density conversion needed No consumable gases required Extremely low maintenance: - No heating elements - No quartz tubing - No columns Dynamic window module design is operator independent and ensures measurement stability Robust industrial design: wall mounted or stand alone Outstanding linearity: One calibration curve for diesel and gasoline matrixes, over full dynamic range Compact footprint 24 w x 17 d x 65 h FIGURE 1 Analytic Engine Configuration Monochromatic excitation = Extremely high S/B Compact and modular analyzer engine design No moving parts in analyzer engine No consumables or sample conversion required Simplified matrix correction

Purge System Type X PLC High Voltage Power Supply User Interface Display Analyzer Engine Sample Management System Dynamic Window Module Product Specifications Electrical Purge Fuel Sampling System Included Ambient Temperature Size and Weight Communication Sample Conditioning Systems Classification Input voltage: 115 VAC, +/- 10%, <300V peak-to-peak max. transient Input frequency: 57 63 Hz Requires 15 amp, dedicated circuit with disconnect 1 MPT in explosion-proof enclosure for X-Purge Instrument Air or Dry Nitrogen 6 scfm @ 60 psig min. for normal operation 12 scfm during initial purge cycle (5 minutes at 75 psi) Connections: (1) 3/8 SST tubing Inlet: 0.03-3.0 GPM: 10-90 psig Outlet: 0.03-3.0 GPM: 0-70 psig Conventional or in NeSSI format 0 40 C (40 104 F) 24 w x 17 d x 65 h 180 lbs. RS 485 cable to lab or control room display interface Ethernet cable for phone modem interface 4-20mA output proportional to sulfur concentration Explosion-proof screen interface Remote diagnostics capability Optional: Sample pressure and flow regulators Particle and H2O removal Class 1, Division 1, Groups C-D, X Purge Class 1, Division 2, Groups C-D, Z Purge

Sample Data FIGURE 2 Linear Calibration 0 500 ppm FIGURE 3 On-Line Monitoring of Diesel Fuels at Various Sulfur Levels Repeatability S Concentration Standard Deviation 1 ppm 0.1 ppm 10 ppm 0.4 ppm 100 ppm 1.3 ppm 500 ppm 3.0 ppm Better Analysis Counts 15 Tech Valley Drive East Greenbush, New York 12061, USA 518-880-1500 Fax: 518-880-1510 e-mail: info@xos.com website: www.xos.com X-Ray Optical Systems, Inc. [2007] Development of this product partially funded by the NEW YORK STATE ENERGY RESEARCH AND DEVELOPMENT AUTHORITY