Han K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/

Han-Power Energy Bus Components

Han Q 1/0 Axial Screw Protected. Available February 2017

Contents Technical characteristics Han A Technical characteristics Han 3 A with HARAX Termination

Contents Technical characteristics Han A Technical characteristics Han 3 A with HARAX Termination

D-Sub adapter Cable entry protection with metric cable entries Cable entry protection with Pg cable entries

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

Crimpmate Range pitch 5.00

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

Han ES Press. Features. Description. Removal of conductor. Size 6 B - 24 B

Operating voltage from 10 KVDC to 15 kvdc. Operating current up to 13 A. 2-5 HV contacts. For cable sizes AWG 26-14

General characteristics and technical data Series MCS

MK 2/ mm 2 IEC UL CSA. IEC UL CSA Rated voltage AWG AWG AWG AWG Rated surge voltage / pollution severity

EPIC CIRCON M23 Series

RockStar HighPower. Contents. RockStar HighPower Introduction C.2 C.1

PCB plug-in connectors

Directory chapter 08. InduCom Robust and EMI protected D-Sub interfaces

Powermate Range pitch 7.00 Powermate Range pitch 7.00

- 1 - General ordering data Order No

Datasheet. System pitch mm (0.400 inch) - SU/BU BUZ 10.16HP/02/180F AG BK BX

General characteristics

JIGO JIGO HEAVY DUTY CONNECTORS HEAVY DUTY CONNECTOR 6 POLE (JG-HE-006)

EPIC. Connector Accessories CONNECTOR ACCESSORIES. Glands, Seal Rings & Adapters Glands 412 EPIC SM & SP Glands, EPIC CM-M Glands

MK 2/ mm 2 IEC UL CSA. IEC UL CSA Rated voltage AWG AWG Rated surge voltage / pollution severity AWG 24..

06. har-mik INTERFACE CONNECTORS

Shell material Insulator Contacts Sealing Temperature Mating Protection

Directory chapter 03 DIN Power (to 15 A) Types H, H 3, MH , MH Technical characteristics type H

Female socket block, Screw connection, No. of poles: 12, Width: mm, Colour: Green

EPIC CIRCON M23 Series

HA series the slim connectors

SEK Solder board connectors

Unimate Range Pitch 5.08

USA Canada On the Internet: Toll Free wieland Product Range Electrical Connections

Multi-pole terminal strips

Printview: Stackable PCB terminal block; 16 mm²; Pin spacing 15 mm; 1-pole; CAGE CLAMP ; commoning option - Item No.

Hints. 1) Han-Modular Inserts. See: HARTING Industrial Connectors Han, chapter 06. 2) Han-HC contacts

Series BHT. Specifications. B HT 6 pole + PE. B HT 10 pole + PE. B HT 16 pole + PE. B HT 24 pole + PE. Page

HDD Insert Series. Application Specification Apr 30 th, 2017 Rev. A. Table of contents

DOUBLE-LEVEL TERMINAL BLOCKS SRKD SSLD

HD Insert Series. Application Specification Apr 30 th, 2017 Rev. A. Table of contents

FL series position switches

NEW. Datasheet. WMF 2.5 Terminal Series

Safety switches for hinges

Standard Hoods/Housings Han B Size 24 B

Contents. Han Q Technical characteristics Han Q 5/ Han Q 5/ Technical characteristics Han Q 7/

AF40... AF96 3-pole contactors Technical data

SCREW-TYPE DISTRIBUTION BLOCKS

ZS4-SF1 Screw Clamp Terminal Block

Transforming customer wishes into concrete solutions

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS CCF. Connectors

CSF - CSM CONNECTORS. Functional characteristics. RoHS 2011/65/EU. Brief description. Dimensional class: low. Standard colour: green

Datasheet WMF 2.5 Terminal Series NEW. Phone: Fax: Web: -

Metal LIQUID TIGHT CONDUIT FITTINGS & ACCESSORIES for Industrial Application

Safety switches with separate actuator

DN9C. Up to 9 contacts 30 A / 415 V max. IP54/IP55 Metal page 74. Up to 7 contacts 25 A / 500 V max. IP66/IP67 GRP or metal page 72

SCREW-TYPE DISTRIBUTION BLOCKS

HYDROCON Standard Sealed Connectors

Safety switches with separate actuator

LR-LX-LK-LW Safety Switches with separate actuator

DBL distribution blocks 3x1 pole

Datasheet. BL/SL 5.08 series BLF 5.08/02/180 SN OR BX

Application Coding Cable diameter Color Part No. Std. Pack Part No. Std. Pack. Female connector. gray black gray black gray black green

Load and Motor Switches, Load-Break Switches Series 8549

Safety rope switch without reset for simple stop

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc.

Installation and Operating Instructions

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Clearwater Tech - Phone: Fax: Web: -

13.1. Range of Enclosures. KRONECTION Box A 2 for up to 2 pairs. Expert Knowledge. Short survey of the KRONECTION Box A 2 for up to 2 pairs

Safety rope switches with reset for emergency stop

revos power New variety for industrial connectors

Safety rope switch with reset for emergency stop

Data sheet... W-Series WPE 4

Datasheet. Approvals. Technical data. Feed-through terminal WK 4 / U BLUE /V0. General. Technical data. Connection Data

Thermal overload relay TF65 and TF96

Multipole Industrial Connectors Aluminium enclosures - Cable glands and fittings

Fuse switch disconnectors

Single foot switches - PX and PA series

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

LK Position Switches TECHNICAL DATASHEET.

Safety switches for hinged doors

Load disconnect switch Series 8146/5-V11

Data sheet... W terminal earth terminal WPE 4

SERIES MHV (H4) HIGH VOLTAGE CONNECTORS

Double-deck PCB terminal strip; 2 solder pins, in line; 4x2-pole; pin spacing 10 mm / in

Position Switches Series 8074/2

Han-Kit Complete Connector Sets Industrial Connectors for Applications up to 500 V / 16 A

Safety switches with solenoid and separate actuator

EPIC. Pin & Sleeve Connectors PIN & SLEEVE CONNECTORS

Position Switches Series 8070/2

Load and Motor Switches, Load-Break Switches Series 8544

SFS-UFS Single Foot Switches

Insulator Connector inserts: Polyamide (PA66) UL 94 V0 All connectors with different shielding material for different jacket and shield diameters.

Load and Motor Switches, Load-Break Switches Series 8544

HARTING Industrial Connectors Han Short Form Catalogue

HDD series the compact connectors

Installation and Operating Instructions

Amphenol-Tuchel Electronics 44 Series

M3 Series Product. Class 0 - protection against electric shock relies upon basic insulation

UK 6-FSI/C. Extract from the online catalog. Order No.:

Transcription:

HK-00, SERIES HK-00 SERIES Modular Heavy-current connector 12-01

HK-00/0HK-00/2 Heavy-current inserts HE-006 HK-00 Technical characteristics Specifications Approvals Inserts Number of contacts Electrical data acc. to EN 61 984 Power area -Rated current -Rated voltage conductor -Rated impulse voltage -Pollution degree Pollution degree 2 also Signal area -Rated current -Rated voltage -Rated impulse voltage -Pollution degree Pollution degree 2 also Insulation resistance Limiting temperatures Flammability acc. to UL 94 Mechanical working life(mating cycles) Contacts Surface Contact resistance For stranded wire acc. to IEC 60 228 Class 5 Axial screw termination Power contacts - Wire gauge - AWG - Hexagonal driver - Stripping length - Tightening torque PE contact (only HK /2) - Wire gauge - AWG - Hexagonal driver - Stripping length - Tightening torque Signal contact (only HK /2) - Wire gauge - AWG - Stripping length - Tightening torque DIN EN 60 664 DIN EN 61 984,/2+PE 0A 1150/00V 8kV 0A 00V 12kV 2 16A 400V 6kV 16A 500V 6kV 2 10 10 polycarbonate -40...+125 V0 500 copper alloy silver 0.2m 5-70mm 2 2-00 SW5 22mm mm 2 5 50 70 N.m 8 9 10 16-5mm 2 5-2 SW4 14mm 6Nm 2.5mm 2 14 7mm 0.5Nm Current carrying capacity The current carrying is limited by maximum temperature of materials for inserts and contacts including terminals Control and test procedures according to DIN EN 60512-5 Operating current[a] A 00 5 250 225 0 175 150 125 100 75 50 25 1 2 0 40 50 60 70 80 90 100 110 1 10 Ambient temperature[ ] 24B Pressure tight hoods/housings with 4 modules 1 Wire gauge5 mm 2 2 Wire gauge50 mm 2 Wire gauge70 mm 2 12-02

HK-00 Inserts HK-00/0,HK-00/2 Heavy-current inserts 1150/00V 0A /0,/2+ Inserts Hoods/Housingssize Pressure tight hoods/housings,detail please find the page12-04~12-05. Axial screw terminal Insert Male Female HK-00/0-M HK-00/0-F 0600510100 06005100 Distance for contact max. 21 mm 16..5 Axial screw terminal Insert Male Female HK-00/2-M HK-00/2-F 0600510110 0600510210 22 6 6.5 4 51.7 4 M 51.7 6 6 F 12-0

2-M4 48 5 29 6 88 M6 60 M6 60 M/PG Pressure tight hoods/housings Degree of protection IP68,M,M HP24B/H-TEH-2S- HP24B/H-TEH-2S-M HP24B/H-TEH-2T- HP24B/H-TEH-2T-M 04125902 041259802 04225902 042259802 H version M 2-M6 HE-006 HK-00 Hoods/Housings M6 M6 HP24B/H-TEH-2S-M6 HP24B/H-TEH-2T-M6 0412602 0422602 M6x1.5 70 110 55 Housings, straight version,m,m HP24B/H-SFH-2H- HP24B/H-SFH-2H-M HP24B/H-SFH-2T- HP24B/H-SFH-2T-M 04124602 04124619802 04224602 04224619802 80 216 187 M Housings, horizontal version,m M50,M M50 HP24B/H-BK-SE-2H- HP24B/H-BK-SE-2H-M HP24B/H-BK-SE-2H-M50 HP24B/H-BK-SE-2T- HP24B/H-BK-SE-2T-M HP24B/H-BK-SE-2T-M50 0412409912 04124099812 04124091612 0422409912 04224099812 04224091612 216 187 59 M4 M 119 15 HP24B/H-BK-2H HP24B/H-BK-2T 04124050002 04224050002 10 108 4-6.5 10 145 R7 12-04

9 4 0.1 5 24.5 10.5 18 88 60 M6 60 HK-00 Hoods/Housings Pressure tight hoods/housings Degree of protection IP68,M HP24B/H-TEH-4S- HP24B/H-TEH-4S-M 04126902 041269802 H version 2-M6 M M6 HP24B/H-TEH-4S-M6 041268602 M6x1.5 70 110 55 Housings, straight version,m HP24B/H-SFH-4H- HP24B/H-SFH-4H-M 0412462902 04124629802 80 216 187 M Housings, horizontal version,m M50 HP24B/H-BK-SE-4H- HP24B/H-BK-SE-4H-M HP24B/H-BK-SE-4H-M50 0412410912 04124109812 04124101612 216 187 118.5 M HP24B/H-BK-4H 04124060002 4-6.5 108 10 2-M4 10 17 12-05

-250 Heavy-current inserts Crimp terminal HE-006 Modular 250 Crimp Technical characteristics Specifications Approvals Inserts Number of contacts Electrical data acc. to DIN EN 61 984 Rated current -Rated voltage -Rated impulse voltage -Pollution degree Insulation resistance Limiting temperatures Flammability acc. to UL 94 Mechanical working life(mating cycles) Contacts Surface Contact resistance Crimp terminal - mm 2 Max. insulation diameter Crimp dies Pressing force requirement Frame Tightening torque of the fixing screws DIN EN 60 664 DIN EN 61 984 1,2,,4,+PE 250A 00V 12kV 10 10 polycarbonate -40...+125 V0 500 Copper alloy hard-silver plated 0. m 5-70 mm 2 18 mm acc. to DIN 46 5 10 kn stainless steel 0.5Nm Current carrying capacity The current carrying is limited by maximum temperature of materials for inserts and contacts including terminals Control and test procedures according to DIN EN 60512-5 Operating current[a] 50 00 250 0 150 100 50 0 0 1 2 10 0 40 50 60 70 80 90 100 110 1 10 Ambient temperature[ ] 24B Pressure tight hoods/housings with 4 modules 1 Wire gauge5 mm 2 2 Wire gauge50 mm 2 Wire gauge70 mm 2 Assembly Details Cut the cable head square and strip the insulation The copper strands must be cleaned from dirt and oxid film Copper strands must not be drilled Insert the cable strand completelyinto the crimp ferrule Insertion check via inspection hole 12-06

-250 Inserts -250 Heavy-current inserts 00V 250A Inserts Hoods/Housingssize Pressure tight hoods/housings,detail please find the page12-08~12-09. Crimp terminal Order crimp contacts separately Insert Male Female 250-MC 250-FC 00011 00012 M 26.5 26.5 72.2 1.6 4.2 F 72 1.6 4.2 Accessories Crimp contacts 250A Silver plated NO. 1 2 Male CHSM250-5 CHSM250-50 CHSM250-70 08121421000 08121400 08121425000 Female CHSF250-5G CHSF250-50G CHSF250-70G 081214200 08121424000 08121426000 For stranded wire acc. to IEC 60 228-5 Crimp zone acc. to DIN 46 25 1 7 2 7 crimp crimp 7 crimp NO. Wire gauge Stripping length 1 2 5 mm 2 50 mm 2 8.45 mm 10.25mm 22 mm 22 mm 70 mm 2 11.75 mm 22 mm PE crimp contacts 250A Silver plated Male CHSM250PE-5 CHSM250PE-50 CHSM250PE-70 08121421100 0812142100 08121425100 Female CHSF250PE-5 CHSF250PE-50 CHSF250PE-70 08121422100 08121424100 08121426100 M 26.5 19.4 8.2.5 1.4 5 8 F 26.5 19.4 8.2.5 1.4 51.9 Tools Manual hydraulic clamp Wire gauge 10-240mm² TL05 09100015000 12-07

4. 7 17 4. 17 2-M4 48 5 29 6 88 60 M6 M6 60 M/PG Pressure tight hoods/housings Degree of protection IP68 HP24B/H-TEH-2S- HP24B/H-TEH-2S- HP24B/H-TEH-2T- HP24B/H-TEH-2T- 0412572 04125702 0422572 04225702 H version 2-M6-250 HE-006 Hoods/Housings Housings, straight version HP24B/H-SFH-2H- HP24B/H-SFH-2H- HP24B/H-SFH-2T- HP24B/H-SFH-2T- 041246172 0412461702 042246172 0422461702 216 187 80 Housings, horizontal version HP24B/H-BK-SE-2H- HP24B/H-BK-SE-2H- HP24B/H-BK-SE-2T- HP24B/H-BK-SE-2T- 04124097212 0412409712 04224097212 0422409712 216 187 119 59 M4 15 HP24B/H-BK-2H HP24B/H-BK-2T 04124050002 04224050002 10 4-6.5 108 10 145 R7 Frame HF24B-004A-M HF24B-004A-F 0024C00 0024C00240 11.25.75 7.75 11.25 12-08

4. 7 17 4. 17 9 4 0.1 5 24.5 10.5 18 88 60 18 60-250 Hoods/Housings Pressure tight hoods/housings Degree of protection IP68 HP24B/H-TEH-4S- HP24B/H-TEH-4S- 0412672 04126702 H version 2-M6 Housings, straight version HP24B/H-SFH-4H- HP24B/H-SFH-4H- 0412462 04124602 216 80 187 Housings, horizontal version HP24B/H-BK-SE-4H- HP24B/H-BK-SE-4H- 04124107212 0412410712 216 187 118.5 HP24B/H-BK-4H 04124060002 4-6.5 108 10 2-M4 10 17 Frame HF24B-004A-M HF24B-004A-F 0024C00 0024C00240 11.25.75 7.75 11.25 12-09

-50 Heavy-current inserts Axial screw terminal HE-006 Modular 50 Technical characteristics Specifications Approvals Inserts Number of contacts Electrical data acc. to EN 61 984 without adapter -Rated current -Rated voltage -Rated impulse voltage -Pollution degree with adapter -Rated current -Rated voltage -Rated impulse voltage -Pollution degree Insulation resistance Limiting temperatures Flammability acc. to UL 94 Mechanical working life(mating cycles) Contacts Surface Contact resistance For stranded wire acc. to IEC 60 228 Class 5 Axial screw termination - Wire gauge - AWG - Stripping length - Max. cable diameter - Tightening torque Screw terminal - - Wrench size - Tightening torque Frame Tightening torque of the fixing screws Tightening torque of the cross-tying screws on the frame for 4 poles DIN EN 60 664 DIN EN 61 984 1,2,/+PE 50A 00V 12kV 50A 4000V 18kV 10 10 polyamide -40...+125 V0 500 copper alloy silver 0.2m 5-70mm 2 / 95-1mm 2 1-00 / 000-0000 19-mm 19.5mm mm 2 5 50 70 95 1 Nm 8 10 12 14 16 M10 SW17 14Nm 0.5Nm 1.5Nm stainless steel Current carrying capacity The current carrying is limited by maximum temperature of materials for inserts and contacts including terminals Control and test procedures according to DIN EN 60512-5 Operating current[a] 500 480 460 0 4 400 80 60 40 0 00 280 260 240 2 0 180 160 140 1 100 80 60 40 4 2 1 0 40 50 60 70 80 90 100 110 1 10 Ambient temperature[ ] 24B Pressure tight hoods/housings with modules 1 Wire gauge50 mm 2 2 Wire gauge70 mm 2 Wire gauge95 mm 2 4 Wire gauge1 mm 2 12-10

-50 Inserts -50 Heavy-current inserts 00/4000V 50A Inserts Hoods/Housingssize Pressure tight hoods/housings,detail please find the page12-14~12-19. Axial screw terminal Insert Male Female 50.70-M (5-70mm 2 ) 50.1-M (95-1mm 2 ) 50.70-F (5-70mm 2 ) 50.1-F (95-1mm 2 ) 0001101 00011010 0001102 000110 M SW5 0.5 75.2.8 1.5 84.7 7. 1.5 28 F SW5 25 28 Assembly Details Step 1: The outer diameter of the cable must not exceed 19.5 mm. Strip the cable by 19 mm. Insert the cable through hood. Step 1: Step 2: Step 2: Press the Han contact NC on the cable strand and applytightening torque according table 1 by using a tightening torques tool.take care that all cable strands fit completely inside the contact termination cavity. During assembling adhere the cable and the contact to minimise axial movement or twisting. Step : Step : Move the perforated plate D across the contacts. Step 4: Step 4: Fit frame E onto the hexagon shape of the contact. Coding can be arranged by turning the contact within 60. Bolt Steps the frame E together with perforated plate D. Step 5: Step 5: Push back the packet inside the hood. Step 6: Tighten the four M screws and the cable gland according manufacturer recommendation. Step 6: 12-11

-50 Heavy-current inserts Crimp terminal HE-006 Modular 50 Crimp Technical characteristics HE Current carrying capacity Specifications Approvals DIN EN 60 664 DIN EN 61 984 The current carrying is limited by maximum temperature of materials for inserts and contacts including terminals Inserts Control and test procedures according to DIN EN 60512-5 Number of contacts Electrical data acc. to EN 61 984 without adapter -Rated current -Rated voltage -Rated impulse voltage -Pollution degree with adapter -Rated current -Rated voltage -Rated impulse voltage -Pollution degree Insulation resistance Limiting temperatures Flammability acc. to UL 94 Mechanical working life(mating cycles) 1,2,/+PE 50A 00V 12kV 50A 4000V 18kV 10 10 polyamide -40...+125 V0 500 Operating current[a] 450 450 400 50 00 250 0 150 100 50 0 1 5 2 4 0 10 0 40 50 60 70 80 90 100 110 1 10 Ambient temperature[ ] 24B Pressure tight hoods/housings with modules 1 Wire gauge5 mm 2 4 Wire gauge95 mm 2 Contacts 2 Wire gauge50 mm 2 5 Wire gauge1 mm 2 Surface Contact resistance Crimp terminal - mm 2 Max. insulation diameter Crimp dies Pressing force Frame copper alloy hard-silver plated 0.m 5-1mm 2 22mm acc. to DIN 46 25 10kN Assembly Details Wire gauge70 mm 2 Cut the cable head square and strip the insulation Tightening torque of the fixing screws Tightening torqueof the cross-tying screws on the frame for 4 poles 0.5Nm 1.5Nm stainless steel The copper strands must be cleaned from dirt and oxid film Copper strands must not be drilled Insert the cable strand completelyinto the crimp ferrule Insertion check via inspection hole 12-12

-50 Inserts -50 Heavy-current inserts 00/4000V 50A Inserts Hoods/Housingssize Pressure tight hoods/housings,detail please find the page12-14~12-19. Crimp terminal Order crimp contacts separately Insert Male Female 50-MC 50-FC 0001100 00010 M 78. 49.6 1.5 1.1 87.5 49.6 1.5 F 1.1 Accessories Crimp contacts 50A Silver plated NO. 1 2 4 5 Male CHSM50-5 CHSM50-50 CHSM50-70 CHSM50-95 CHSM50-1 08121501000 0812150000 08121505000 08121507000 08121509000 Female CHSF50-5G CHSF50-50G CHSF50-70G CHSF50-95G CHSF50-1G 081215000 08121504000 08121506000 08121508000 08121510000 For stranded wire acc. to IEC 60 228-5 Crimp zone acc. to DIN 46 25 7 crimp 7 22 crimp 5 22 5 2 crimp crimp.5.5 Tools Manual hydraulic clamp 10-240mm² TL05 09100015000 crimp NO. Wire gauge Φ 1 2 4 5 5 mm 2 50 mm 2 70 mm 2 95 mm 2 1 mm 2 8.2 mm 10.0mm 11.5 mm 1.5 mm 15.5 mm Stripping length 26 mm 28 mm 28 mm 0 mm 24 mm 12-1

Pressure tight hoods/housings Degree of protection IP68 M25 M M25 M HP6B/H-TEH-2S-M25 HP6B/H-TEH-2S-M HP6B/H-TEH-2T-M25 HP6B/H-TEH-2T-M 0410645102 04106451402 04645102 046451402 H version M/PG 100 1 2-M6-50 HE-006 Hoods/Housings Frame, size 6B hoods/housings HF6B-001C 0006C00100 Frame, size 16B hoods/housings 2M25 2M25 HP6B/H-BK-2H HP6B/H-BK-2T HP16B/H-TEH-2S-2M25 HP16B/H-TEH-2T-2M25 HF16B-002C 04106050002 046050002 0411645602 0421645602 0016C000 29 MX10 M/PG 1 70 48 4- M/PG 6.5 51 2-M4 14.5.4.4 166 70 5 2-M6 MX10 77.5 84.5 15 HP16B/H-BK-2H HP16B/H-BK-2T 04116050002 04216050002 29 166 10 82 4-6.5 2-M4 48 5 10 118 R7 12-14

2-M4 48 5 29-50 Hoods/Housings Pressure tight hoods/housings Degree of protection IP68 2M25 2M 2M25 2M HP24B/H-TEH-2S-2M25 HP24B/H-TEH-2S-2M HP24B/H-TEH-2T-2M25 HP24B/H-TEH-2T-2M 04125602 041256402 04225602 042256402 H version M/PG M/PG 2-M6 Frame, size 24B hoods/housings HF24B-002C 0024C000 MX10 15.4 HP24B/H-BK-2H HP24B/H-BK-2T 04124050002 04224050002 10 108 4-6.5 10 145 R7 12-15

6 88 M6 60 M6 60 2-M4 48 5 29 Pressure tight hoods/housings Degree of protection IP68 HP24B/H-TEH-2S- HP24B/H-TEH-2T- 04125902 04225902 H version 2-M6 HE-006-50 Hoods/Housings -M25x1.5-6H 70 Frame, size 24B hoods/housings HF24B-00C 0024C002.4 MX10 15 HP24B/H-BK-2H HP24B/H-BK-2T 04124050002 04224050002 10 108 4-6.5 10 145 R7 Housings, straight version HP24B/H-SFH-2H- HP24B/H-SFH-2T- 04124602 04224602 80 216 187 HP24B/H-BK-SE-2H- HP24B/H-BK-SE-2T- 0412409912 0422409912 216 187 119 59 M4 15 12-16

48 5 9 28.5 9 12 5 9 5 9 12 100-50 Hoods/Housings Pressure tight hoods/housings Degree of protection IP68 M25 M HP6B/H-TEH-4S-M25 HP6B/H-TEH-4S-M 0410646102 04106461402 H version M/PG 11 Frame, size 6B hoods/housings HF6B-001C 0006C00100 Frame, size 16B hoods/housings 2M25 HP6B/H-BK-4H HP16B/H-TEH-4S-2M25 HF16B-002C 04106060002 0411646602 0016C000 4-6.5 2-M4 MX10 166 146 77.5 51 14.5.4.4 11 48 70 MX10 77.5 84.5 15 HP16B/H-BK-4H 04116060002 4-6.5 118 10 82 146 12-17

9 4 0.1 5 9 Pressure tight hoods/housings Degree of protection IP68 H version -50 HE-006 Hoods/Housings 2M25 2M HP24B/H-TEH-4S-2M25 HP24B/H-TEH-4S-2M 04126602 041266402 2-M6 17 Frame, size 24B hoods/housings HF24B-002C 0024C000 MX10 15.4 4-6.5 HP24B/H-BK-4H 04124060002 2-M4 108 10 17 12-18

24.5 10.5 18 88 60 M6 60 9 4 0.1 5 9 12 1-50 Hoods/Housings Pressure tight hoods/housings Degree of protection IP68 HP24B/H-TEH-4S- 04126902 2-M6 -M25x1.5-6H M HP24B/H-TEHH-4S-M 04124989402 17 Frame, size 24B hoods/housings HF24B-00C 0024C002.4 MX10 15 HP24B/H-BK-4H 04124060002 2-M4 4-6.5 108 10 17 Housings, straight version HP24B/H-SFH-4H- 04124629802 80 216 187 HP24B/H-BK-SE-4H- 04124109812 216 187 118.5 12-19

-650 Heavy-current inserts Axial screw terminal HE-006 Modular 650 Technical characteristics Specifications Approvals Inserts Number of contacts Electrical data acc. to EN 61 984 -Rated current -Rated voltage -Rated impulse voltage -Pollution degree Insulation resistance Limiting temperatures Flammability acc. to UL 94 Mechanical working life(mating cycles) Contacts Surface Contact resistance For stranded wire acc. to IEC 60 228 Class 5 Axial screw termination - Wire gauge - MCM - Stripping length - Max. cable diameter - Tightening torque Screw terminal - - Tightening torque Frame Tightening torque of the fixing screws DIN EN 60 664 DIN EN 61 984 1,2 650A 4000V 18kV 10 10 polyamide -40...+125 V0 500 copper alloy silver 0.2m 70-1mm 2 / 150-185mm 2 18-26 / 00-50 2-25 26.5mm mm 2 70 95 1 150 185 Nm 12 14 16 17 18 M12 16-18Nm stainless steel 0.5Nm Current carrying capacity The current carrying is limited by maximum temperature of materials for inserts and contacts including terminals Control and test procedures according to DIN EN 60512-5 A Operating current[a] 5 4 2 1 6 ( ) Ambient temperature[ ] 24B Pressure tight hoods/housings with 2 modules 1 Wire gauge70 mm 2 4 Wire gauge150 mm 2 2 Wire gauge95 mm 2 5 Wire gauge180 mm 2 Wire gauge1 mm 2 6 Wire gauge240 mm 2 12-

-650 Inserts -650 Heavy-current inserts 4000V 650A Inserts Hoods/Housingssize Pressure tight hoods/housings,detail please find the page12-24~12-25. Axial screw terminal Insert Male Female 650.1-M (70-1mm 2 ) 650.185-M (1-185mm 2 ) 650.1-F (70-1mm 2 ) 650.185-F (1-185mm 2 ) 000110100 000110110 0001100 000110210 M 40 40 40 8.5 8.6 110 2.1 110 2.1 5 7 F. 5 7 Assembly details Step 1 Strip cable to 2+2 mm Step 1Stripping length Step 2Push conductor through the cable gland and the housing. Push the stripped end of the conductor into the termination entry of the module until the insulation touches the contact. Step 2 and Step Step To tighten the axial screw, a hexagonal wrench size 8 is needed.insert the hexagonal wrench on the mating side of the contact. At the same time, push the conductor over the axial screw.the locking screw has to be tightened with the recommended tightening torque that is determined by the conductor s cross section. Step 4 and Step 5 Step 4Once the modules are terminated, they are mounted into the housing by using two metal frames (tightening torque of the fixing screws = 0.5 Nm). The modules have 4 pegs formed by 2 parallel ribs (each peg shapes like a H ).Each rib takes 1 pole frame, w- here the lateral link has to go into the relief of the frame. The 2 pole frames have 2 cutouts on the wall which get fitted to the H -shaped pegs (see figure).the heads of the screws have to face the mating direction of the module.coding can be establishedby rotating the contact by 90 degrees. Therefore it is important that the corresponding modules are assembled in the correct position otherwise mating is not possible Frame Hood Termination entry, Fixing screws, Step 5 After assembling the modules in the housing, the tightening torque of the locking screw can be checked and corrected if necessary. parallel ribs with Step 6 After final assembly of the contacts,the user should ensure that the cable is adequately strain reliefed to protect the contact from radial stress. Housings bulkhead mounting 12-21

-650 Heavy-current inserts Crimp terminal HE-006 Modular 650 Technical characteristics Specifications Approvals Inserts Number of contacts Electrical data acc. to EN 61 984 without adapter -Rated current -Rated voltage -Rated impulse voltage -Pollution degree with adapter -Rated current -Rated voltage -Rated impulse voltage -Pollution degree Insulation resistance Limiting temperatures Flammability acc. to UL 94 Mechanical working life(mating cycles) Contacts Surface Contact resistance Crimp terminal - mm 2 Max. insulation diameter Pressing force requirement Frame Tightening torque of the fixing screws DIN EN 60 664 DIN EN 61 984 1,2 650A 00V 12kV 650A 4000V 18kV 10 10 polyamide -40...+125 V0 500 copper alloy hard-silver plated 0.m 240mm 2 mm 10kN stainless steel 0.5Nm Current carrying capacity The current carrying is limited by maximum temperature of materials for inserts and contacts including terminals Control and test procedures according to DIN EN 60512-5 Operating current[a] A Ambient temperature[ ] 24B Pressure tight hoods/housings with 2 modules Assembly Details Cut the cable head square and strip the insulation The copper strands must be cleaned from dirt and oxid film Copper strands must not be drilled Insert the cable strand completelyinto the crimp ferrule Insertion check via inspection hole 12-22

-650 Inserts -650 Heavy-current inserts 4000V 650A Inserts Hoods/Housingssize Pressure tight hoods/housings,detail please find the page12-24~12-25. Crimp terminal Order crimp contacts separately Insert Male 650-MC 0001110 8.55 99.5 2.1 Female 650-FC 0001210 M 40 8.55 99.5 2.1 F 40 Accessories Crimp contacts 650A silver plated NO. 1 Male CHSM650-240 08121601000 Female CHSF650-240G 081216000 For stranded wire acc. to IEC 60 228-5 Crimp zone acc. to DIN 46 25 7 1 1 2 crimp NO. Wire gauge Φ Stripping length 1 240 mm 2 22.5 mm 46 mm Tool Manual hydraulic clamp Wire gauge 10-240mm² TL05 09100015000 12-2

2-M4 48 5 29 Pressure tight hoods/housings Degree of protection IP68 M40 M40 HP6B/H-TEH-2S-M40B HP6B/H-TEH-2T-M40B 04106451512 046451512 H version X M/PG 0 100-650 HE-006 Hoods/Housings 1 Frame, size 6B hoods/housings HF6B-001R 0006C00110 4 MX10 55 HP6B/H-BKH-2H HP6B/H-BKH-2T 04106050012 046050012 2M40 2M40 HP24B/H-TEH-2S-2M40B HP24B/H-TEH-2T-2M40B 041256512 042256512 56 M/PG M/PG 0 110 192 HF24B-002R 0024C00210 17 29 1 70 48 5 4-6.5 2-M4 70 Frame, size 24B hoods/housings MX10 56 92 2 1.95 HP24B/H-BK-2H HP24B/H-BK-2T 04124050002 04224050002 10 108 4-6.5 10 145 R7 12-24

9 4 0.1 5 9 8.6 5-650 Hoods/Housings Pressure tight hoods/housings Degree of protection IP68 M40 HP6B/H-TEH-4S-M40B 04106461512 H version M/PG 0 X 100 1 Frame, size 6B hoods/housings HF6B-001R 0006C00110 MX10 55 HP6B/H-BK-4H 04106060002 2M40 HP24B/H-TEH-4S-2M40B 041266512 56 M/PG M/PG 110 17 4 4-6.5 2-M4 11 48 70 0 192 Frame, size 24B hoods/housings HF24B-002R 0024C00210 MX10 56 92 2 1.95 HP24B/H-BK-4H 04124060002 2-M4 4-6.5 108 10 17 12-25