FADE Series Wall Axial Fans

Similar documents
HP190SL Series Slimline Radon Fans

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

Models eged/egsd. Installation, Operation, and Maintenance Manual. Direct Drive Sidewall Propeller Fans (Exhaust and Supply)

FarmTek Stock Numbers

2SHE Series Direct-Drive Shutter Fans

1SDE Series Standard Duty Exhaust Wall Fans

8-12 INSTALLATION AND WIRING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS

SDBDe, STXDe, ered* Installation, Operation, and Maintenance Manual INSTALLATION AND WIRING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS

Models GED/GSD, DFE/DFS & DDE/DDS Installation, Operation, and Maintenance Manual

ered Installation, Operation, and Maintenance Manual Direct Drive sizes 6-15 Nonoverloading B.I. Wheel

Air Curtain. Installation, Operating and Maintenance Instructions

SDBDe, STXDe, STXDeRHUL

Model CWD Installation, Operation, and Maintenance Manual

5DDU-EC Series Direct Drive Upblast Roof Ventilator

SPC-PANEL Simplex, Single Phase Pump Control Panel

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

SOLAR DASH CHARGING SYSTEM USER GUIDE

NUTONE RANGE HOOD NTM SERIES

INW Panel Meter Reading an INW PT12 Sensor

Kitchen Tech Series Air Curtain

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

User s guide SIRH series Infrared radiator heater models: SIRH4002W*, SIRH4203W*, SIRH6002W* *Add R for the weather-resistant model

Pump Installation and Service Manual HRS Hydromatic Retractable System

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

BCFS Belt Driven Centrifugal Filtered Supply Fans

Power. On Your Terms.

10 Year Limited Warranty

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

ELECTRONIC FIREPLACE DAMPER

HARTZELL. Cool Blast, Utility, and HartKool. Fans. Hartzell Fan, Inc., Piqua, Ohio

PVI 60KW, PVI 82KW, PVI 95KW

Installation Instructions

SUNC3000 / Item #40885

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

Raydot LLC 24 Actuator (115 VOLT)

ESE Series Cast Iron Sewage Pumps

SUNTURA SOLAR TRACKER

User s Manual and Operating Instructions

Hood. warning. warning. caution

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

! FOR DOMESTIC COOKING ONLY!

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

SUNTURA HD SOLAR TRACKER

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

WIND STOPPING 14 (WMI) AND WIND STOPPING 16 (WMH) INDUSTRIAL SERIES

Bulletin REXJR05 CENTREX REX JR. Model: REXJR Direct Drive Centrifugal Inline Fans

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

OPERATING MANUAL. centrifugal fan SAFETY PRACTICES

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

! FOR DOMESTIC COOKING ONLY!

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

INVERTER HARNESS INSTALLATION FOR FREIGHTLINER CASCADIA

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

37SCENE 46SCENE 79SCENE

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

Installation and Operation Manual

6 OFF ROAD LIGHT BAR

Model Numbers: MAC-36-BDF, MAC-42-BDF, MAC-48-BDF CONSUMER: READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

SYSTEM CONTROL KIT. Model: CK-41F. Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances.

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

Operating and Installation Instructions

User s Manual for Tennessee Chill Box System P/N CB8000

User s Manual and Operating Instructions

WhispAire Range Hood Quiet Hood

RANGE HOODS USER INSTRUCTIONS

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

DAP-625S and DAP-875S

Instruction Book for. ContouR ElECtRol

HBC-20 - LED HIGH BAY

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

P/N# Performance Lowering Springs Installation Instructions

BULLETIN: VB PVC BLOWER-SCRUBBER VIRON INTERNATIONAL

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

OPERATING MANUAL. aeration fans. models: sa sa sa SAFETY PRACTICES

EMISSION CONTROL WARRANTY STATEMENT

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

SUBMERSIBLE POND PUMP

Users Guide for Ac-sync

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

ASSEMBLY / OPERATION INSTRUCTIONS. Low Profile Motorcycle Dolly

MaxLite LED Linear HighBay Fixtures

SUBMERSIBLE PUMP. Model ASSEMBLY AND OPERATING INSTRUCTIONS

ADI-125/750 ADI-125/1500 ADI-125/2500

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

Transcription:

Installation and Operation Manual Item #: 401442 Rev Date: 070113 FADE Series Wall Axial Fans Fantech Inc. certifies that the FADE Series shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. United States 10048 Industrial Blvd., Lenexa, KS, 66215 Tel.: 800.747.1762 Fax: 800.487.9915 Canada 50 Kanalflakt Way, Bouctouche, NB, E4S 3M5 Tel.: 800.565.3548 Fax: 877.747.8116

2 Note Warning/ Important note Information Technical information Practical tip Read and Save these instructions for future reference. 1. FADE units can be mounted at any angle for exhaust ventilation. When planning installation, allow adequate space for blower removal for service or inspection. 2. Because this unit has rotating parts, safety precautions should be exercised during all phases of installation, operation and maintenance. 3. CAUTION: For General Ventilation Use Only. Do Not Use To Exhaust Hazardous Or Explosive Material and Vapors. 4. Remove unit from package and inspect within 10 days after receipt. If damaged, report damage to carrier. Do Not operate this unit with visible damage to the blower or impeller assembly. 5. Ensure centrifugal impeller has free rotation. If impeller hits orifice, check screws holding motor bracket. Tighten all screws before operating unit. WEAR HAND PROTECTION AND STAY CLEAR OF SHARP EDGES! 6. Screen guards must be installed within reach of personnel, within (7) feet of the working area, or when advisable for safety. 7. When mounting fan, the inside dimension of the opening should correspond to dimension D possibly allowing an extra 1/4. When using a louver or damper, provide adequate framing depth to accommodate the fan. PLEASE read the entire manual before installing. Warnings DO NOT CONNECT POWER SUPPLY until fan is completely installed. Make sure electrical service to the fan is in the locked OFF position. 1. All fans are suitable for use with solid-state speed control. 2. WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS - OBSERVE THE FOLLOWING: a. Use this unit in the manner intended by the manufacturer. If you have any questions, contact your manufacturer s representative or contact us directly. b. CAUTION: Before installation, servicing or cleaning unit, switch power off at service panel and lock the service disconnection means to prevent power from being switched on accidentally. When the service disconnection means cannot be locked, securely fasten a prominent warning device, such as tag, to the panel. c. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. d. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Association (NFPA), and the American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities. e. When cutting or drilling into wall and ceiling, do not damage electrical wiring and other hidden utilities. f. Ducted fans must always be vented to the outdoors. g. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit. h. NEVER place a switch where it can be reached from a tub or shower. 3. WARNING! Check voltage at the fan to see if it corresponds to the motor name plate.

Dimensions 3 FADE S-TYPE Fan Only Model FADE S-TYPE Fully Assembled Model FADE A-TYPE Fan Only Model FADE A-TYPE Fully Assembled Model Model A B C D1 D2 E F G Blade Type FADE 8-4 12 5/16 2 10 1/4 7 3/4 8 1/16 1/4 - - S FADE 10-4 14 9/16 2 12 5/8 10 10 5/16 1/4 - - S FADE 12-4 / FADE 12-4 WHD 17 3 15 12 12 7/8 5/16 21 15 1/2 S FADE 14-4 / FADE 14-4 WHD 19 3/16 3 1/8 17 1/8 14 15 3/8 5/16 21 15 1/2 S FADE 16-4 / FADE 16-4 WHD 22 3/4 3 1/2 21 16 1/2 17 1/4 3/8 24 16 1/2 S FADE 18-4 / FADE 18-4 WHD 22 9/16 4 1/4 21 18 18 1/2 3/8 24 16 1/2 S FADE 20-4 / FADE 20-4 WHD 25 3/16 4 1/2 24 1/4 20 20 1/2 3/8 26 17 1/2 A FADE 20-6 / FADE 20-6 WHD 25 3/16 4 1/2 24 1/4 20 20 1/2 3/8 26 17 1/2 A FADE 22-6 / FADE 22-6 WHD 28 5/8 5 1/4 26 9/16 22 22 1/2 3/8 32 18 3/4 A FADE 25-6 / FADE 24-6 WHD 31 3/4 6 29 1/2 25 25 1/2 3/8 32 18 3/4 A All dimensions in inches. FADE 12 through FADE 25 models can be ordered fully assembled with housing and damper. See Fantech Catalog for detailed descriptions and model numbers.

4 wiring SPECIAL WIRING PRECAUTIONS: All installation should be wired according to the following diagrams. Failure to comply will cause the motor to "hum" or not work. All units are pre-wired, just bring incoming supply into marked ports on terminal strip. (EXCEPT FOR 3 PHASE UNITS, please use a motor contactor & TK leads to prevent damage to motor). Maximum torque that can be applied to the terminal block screws is 0.79 Nm (7 lb-in). 120/230 Volt Single Phase Fans FADE 8-4 120/230 Volt Single Phase Fans FADE 10-4, 12-4, 14-4, 16-4 Green/Yellow (Ground) Capacitor Motor Leads Blue Black N/L2 L/L1 Supply Voltage Motor Leads White or Brown(TK) Black (Z1) Blue (U2) L/L1 N/L2 Supply Voltage Green/Yellow (Ground) 120/230 Volt Single Phase Fans FADE 18-4, 20-4, 22-6 25-6 Capacitor Wiring schematic for 4 lead meotors, single phase 1. All leads are color coded as well as identified with an Alpha / Alpha or Alpha / Numeric code (i.e. TK or Z2). This code may be shown as a band on the wire or on a schematic on the motor hub. Colors should be verified against code band. If code band and color do not correspond to schematics above, wire according to the code on the band. 2. Color of capacitor leads may be reversed. Fan operation will not be affected. Motor Leads Black (Z1) White or Brown(TK) Blue (U2) Green/Yellow L/L1 N/L2 (Ground) Supply Voltage 230 Volt Three Phase Fans FADE 20-4, 22-6, 25-6 1. Contactor should be used. Control coil should be wired in series with motor thermal contacts (TK leads) as shown in diagram to provide thermal motor protection. 2. All leads are color coded as well as identified with a band containing an Alpha/Alpha or Alpha/Numeric code (i.e. TK or Z2). Colors should be verified against code band. If code band and color do not correspond to schematics above, wire according to the code on the band.

5 Wiring (cont'd) 460 Volt Three Phase Fans FADE 20-4, 22-6, 25-6 For 460 colt operation, Orange (W2), red (U2) and Grey (V2) wires must be spliced 1. Contactor should be used. Control coil should be wired in series with motor thermal contacts (TK leads) as shown in diagram to provide thermal motor protection 2. All leads are color coded as well as identified with a band containing an Alpha/Alpha or Alpha/Numeric code (i.e. TK or Z2). Colors should be verified against code band. If code band and color do not correspond to schematics above, wire according to the code on the band. 120 Volt Single Phase Fans FADE 20-6 Contactor for 3-Phase Fans, 208-230/460 volt Capacitor Incoming 3-Phase Supply 208/230/460 Motor Leads Black (Z1) White (TK) Blue (U2) Green/Yellow Orange (Z2) Brown (U1) L N (Ground) Supply Voltage Control Power for Contactor C1 C2 T1 T2 T3 L1 L2 L3 AC Contactor Ground White (TK) TK TK L1 L2 L3 L3 Motor Leads

6 Warranty Three (3) Year Warranty This warranty supersedes all prior warranties DURING ENTIRE WARRANTY PERIOD: Fantech will repair or replace any part which has a factory defect in workmanship or material. Product may need to be returned to the Fantech factory, together with a copy of the bill of sale and identified with RMA number. FOR FACTORY RETURN YOU MUST: Have a Return Materials Authorization (RMA) number. This may be obtained by calling Fantech either in the USA at 1.800.747.1762 or in CANADA at 1.800.565.3548. Please have bill of sale available. The RMA number must be clearly written on the outside of the carton, or the carton will be refused. All parts and/or product will be repaired/replaced and shipped back to buyer; no credit will be issued. OR The Distributor may place an order for the warranty part and/or product and is invoiced. The Distributor will receive a credit equal to the invoice only after product is returned prepaid and verified to be defective. Fantech WARRANTY TERMS DO NOT PROVIDE FOR REPLACEMENT WITHOUT CHARGE PRIOR TO INSPECTION FOR A DEFECT. REPLACEMENTS ISSUED IN ADVANCE OF DEFECT INSPECTION ARE INVOICED, AND CREDIT IS PENDING INSPECTION OF RETURNED MATERIAL. DEFECTIVE MATERIAL RETURNED BY END USERS SHOULD NOT BE REPLACED BY THE DISTRIBUTOR WITHOUT CHARGE TO THE END USER, AS CREDIT TO DISTRIBUTOR S ACCOUNT WILL BE PENDING INSPECTION AND VERIFICATION OF ACTUAL DEFECT BY Fantech. THE FOLLOWING WARRANTIES DO NOT APPLY: Damages from shipping, either concealed or visible. Claim must be filed with freight company. Damages resulting from improper wiring or installation. Damages or failure caused by acts of God, or resulting from improper consumer procedures, such as: 1. Improper maintenance 2. Misuse, abuse, abnormal use, or accident, and 3. Incorrect electrical voltage or current. Removal or any alteration made on the Fantech label control number or date of manufacture. Any other warranty, expressed, implied or written, and to any consequential or incidental damages, loss or property, revenues, or profit, or costs of removal, installation or reinstallation, for any breach of warranty. WARRANTY VALIDATION The user must keep a copy of the bill of sale to verify purchase date. These warranties give you specific legal rights, and are subject to an applicable consumer protection legislation. You may have additional rights which vary from state to state. Limitation of Warranty and Liability This warranty does not apply to any Fantech product or part which has failed as a result of faulty installation or abuse, incorrect electrical connections or alterations made by others, or use under abnormal operating conditions or misapplication of the product or parts. We will not approve for payment any repair not made by us or our authorized agent without prior written consent. The foregoing shall constitute our sole and exclusive warranty and our sole exclusive liability, and is in lieu of any other warranties, whether written, oral, implied or statutory. There are no warranties which extend beyond the description on the page hereof. In no event, whether as a result of breach of contract, or warranty or alleged negligence, defect incorrect advice or other causes, shall Fantech be liable for special or consequential damages, including, but not limited to, loss of profits or revenue, loss of use of equipment or any other associated equipment, cost of capital, cost of substitute equipment, facilities or services, downtime costs, or claims of customers of purchase for such damages. Fantech neither assumes or authorizes any person to assume for it any other liability in connection with the sale of product(s) or part(s). Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you. Warning Fantech products are designed and manufactured to provide reliable performance, but they are not guaranteed to be 100% free from defects. Even reliable products will experience occasional failures and this possibility should be recognized by the user. If these products are used in a life support ventilation system where failure could result in loss or injury, the user should provide adequate backup ventilation, supplementary natural ventilation, failure alarm system, or acknowledge willingness to accept the risk of such loss or injury.

notes 7

Fantech reserves the right to make technical changes. For updated documentation please refer to www.fantech.net Fantech