SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Similar documents
SUNC3000 / Item #40885

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

AUTOMATIC SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

GARDEN HOSE UTILITY PUMP

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

HALLMARK INDUSTRIES INC

SUBMERSIBLE SUMP PUMPS

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

SUBMERSIBLE SUMP PUMPS

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

ESE Series Cast Iron Sewage Pumps

THERE IS NO OTHER EXPRESS WARRANTY.

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

StormPro BA Series Sump Pump

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Sump / Effluent Pump

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

PRE-PLUMBED SEWAGE SYSTEM

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

115 VOLT TRANSFER PUMP

SUBMERSIBLE MINI-PUMP

SUPER PUMP OUT SYSTEM

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Ion Technologies WC33 Submersible Sump Pump

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Powerful & Intelligent Submersible Pumps

Matala. VersiFlow Series. Instruction and Maintenance Manual

StormPro BCV400 Sewage Ejector Pump

1/2 HP CAST IRON TRANSFER PUMP

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

Illumifalls Patio Pond

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

GeyserMax-Flow Series

Submersible Pond Pump with UV 800 Gallons Per Hour

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Submersible Waterfall Pump 1200 Gallons Per Hour

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Premium Pond Pump 330 Gallons Per Hour

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

Owner s Manual Drill and Light Weight Portable Utility Pumps

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS

SHALLOW WELL JET PUMP

Premium Waterfall Pump 1200 Gallons Per Hour

MODEL P INSTALLATION INSTRUCTIONS

STAR STOP SHALLOW WELL JET PUMP

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

SUBMERSIBLE SWIMMING POOL DRAINER

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

PL Submersible, Semi-Vortex, Water Feature Pump

LESTRONIC II BATTERY CHARGER MODEL 19740

OWNER S MANUAL CONVERTIBLE JET PUMP

SUBMERSIBLE PUMP. Model ASSEMBLY AND OPERATING INSTRUCTIONS

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Operating Manual Includes Pumps: PG-9000 Part #R809606

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

MODEL H INSTALLATION INSTRUCTIONS

Sealless Centrifugal Canned Motor Pumps

SuperFlo 9,000 High Volume Pump Product Manual

G8 Portable Fuel Transfer Pump Owner s Manual

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

QPET, QPETXU Battery Chargers

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

SUBMERSIBLE POND PUMP

OBE, OBEXU, ON BOARD Battery Chargers

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

QSSE, QSSEX INDUSTRIAL Battery Chargers

Unilift KP 150, KP 250, KP 350

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

INSTALLATION & OPERATION MANUAL

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Pump Installation and Service Manual HRS Hydromatic Retractable System

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

SPC-PANEL Simplex, Single Phase Pump Control Panel

MODEL INSTALLATION INSTRUCTIONS. 12 Volt UTILITY PUMP

SUBMERSIBLE PUMP HSE RANGE

Natural Fiber Planter Fountain

OBAE, OBAEXU, ON BOARD Battery Chargers

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

Container Fountain Kit with LED Light

SUBMERSIBLE PUMP HSE RANGE

36 VOLT AUTOMATIC BATTERY CHARGER PART NO

User s Manual. Automatic Switch-Mode Battery Charger

Transcription:

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM

Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200 1/6 1500 1400 1300 1100 750 300 26 ft. Safety Information Please read and understand this entire manual before attempting to assemble, operate or install the product. If you have any questions regarding the product, please call customer service at 877-278-2797 DANGER 1. Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not disassemble the motor housing. 2. Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resulting in property damage, serious personal injury and/or death. 3. ALWAYS disconnect the power to the pump before servicing. 4. Do not handle pump or pump motor with wet hands or when standing on wet or damp surface, or in water. WARNING 1. Release all pressure and drain all water from system before servicing any component. 2. Secure discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage. 3. Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension cord to power this pump is not permitted. 4. Wear safety goggles at all times when working with pumps. 5. This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 3-conductor cord and 3-prong grounded plug. DO NOT REMOVE THE GROUND PIN UNDER ANY CIRCUMSTANCES. The 3- prong plug must be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not use this pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and local codes and ordinances. All wiring should be performed by a qualified electrician. 6. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use damaged or worn cords. 7. Failure to comply with instruction and designed operation of this unit, may void warranty. ATTEMPTING TO USE A DAMAGED PUMP can result property damage, serious personal injury and/or death. 8. Make certain the electrical circuit to the pump is protected by a 10 Amp fuse or circuit breaker. CAUTION 1. Do not lift pump by the power cord. 2. Know the pump and its applications, limitations, and potential hazards. 3. Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping the pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature failure.

4. Periodically inspect the pump and system components to be sure the pump inlets are free of mud, sand, and debris. DISCONNECT THE PUMP FROM THE POWER SUPPLY BEFORE INSPECTING. 5. Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In additional, all Occupational Safety and Health Administration (OSHA) guidelines must be followed. IMPORTANT 1. The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset itself once the motor cools down and an acceptable temperature has been reached. The pump may start unexpectedly if it is plugged in. 2. Make certain the electrical power source is adequate for the requirements of the pump. 3. Before using the pump, check hose for holes or excess wear, which could cause leaks, and be sure hose is not kinked or making sharp angles. A straight hose allows the pump to move the greatest amount of water quickly, and also check that all hose connections are tight to minimize leaks. NOTE 1. This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long time when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris may cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump problems and remedies. 2. Always make sure the pump is unplugged as soon as the water level reaches 1/2 in. At water levels less than 1/2 in., the pump is attempting to pump air, which will cause the pump to overheat and wear out. Running the pump without sufficient water will damage the pump and void the pump s warranty Application The submersible pump is designed for water removal applications. Use this pump only for pumping water. It can drain or remove water from the following: pits, sinks, window wells, basements, swimming pool covers, boats, low spots in yards, or other flooded areas. This pump is not designed to function as a permanently installed sump pump. It is also not engineered to be run continuously as a fountain or waterfall pump. Features:! Ending water level max-----1/2! Operating water depth - beginning minimum -------1 Pre-installation TOOLS REQUIRED Flathead Screwdriver Phillips Screwdriver Safety goggles

MATERIALS REQUIRED (NOT INCLUDED) NOTE: Hose and hose kit shown not to scale Garden Hose 1-1/4 in. Hose Kit PACKAGE CONTENTS NOTE: Adapter shown not to scale Part A B Description Pump 1-1/4in. hose adapter Pre-installation(continued) ESTIMATED INSTALLATION TIME 5 minutes SPECIFICATIONS Voltage Hertz Ampere 115V (single phase) 60Hz 10A (GFCI 3-prong receptacle)

Installation CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug the pump and allow time for it to cool after periods of extended use. 5/8 in. Garden Hose Connection Attach a 5/8 in. inside diameter or larger garden hose (not included) to the pump outlet. 1-1/4 in. Hose Kit Connection If you would prefer to use a larger hose in order to pump water away more quickly, attach the included adaptor to pump, and then securely attach the Hose Kit ( sold separately) to the adaptor. NOTE: Be sure the hose end has a rubber washer to minimize water leaks. WARNING: Secure the discharge hose before plugging in the pump. Pump torque may cause an unsecured discharge hose to whip, possibly causing personal injury and/or property damage. Operation 1 Place the pump in flooded area or any place that you would like to remove water. And plug the pump into a 115 volt GFCI power outlet. 2 Allow pump to run and monitor its progress. UNPLUG when pump has removed water down to approximately 1/2. Remove the pump and hose from the location when finished pumping, as the hose still has water that can drain back through the pump. Remove remaining water with squeegee, mop, sponge, towel, wet/dry vac, etc. NOTE: After starting, the pump will lower the water level to 1/2 (12.7mm) before losing suction. It will not pick up water less than 1/2 (12.7mm) deep when running and will not operate successfully if started in

only 1/2 (12.7mm) of water. NOTE: The pump must be standing in at least 1 (25.4mm) of water before starting it. The shaft seal is water lubricated and may be damaged if pump runs dry. NOTE: Place upright on a solid base. WARNING: Do not handle pump or pump motor with wet hands or when standing on wet or damp surface, or in water. Airlock CAUTION: Do not run the pump dry. Operating the pump without water will cause damage to seals and will cause the pump to fail, thereby voiding the pump s warranty. This pump is a centrifugal utility pump, designed to efficiently remove water. However, it cannot move air. If air is trapped inside the pump (a condition called airlock ), the pump cannot pump water out even though the pump is completely submerged. This pump has an anti- airlock hole. Air flows out through the anti-airlock hole, eliminating the air so that the pump can operate properly. If debris blocks the anti-airlock hole or if the anti-airlock hole cannot move freely, unplug the pump, clean out the anti-airlock hole, and restart the pump. Alternately, drain the water out of the garden hose, keep the end of the hose out of the water, and plug in the power cord, restarting the pump. CAUTION: This hole is for anti-airlock purpose, leakage of air or water is NORMAL and NECESSARY. DO NOT REMOVE OR PLUG THIS HOLE! Care and Cleaning CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug the pump and allow time for it to cool after periods of extended use. Do " When the power is disconnected, inspect the pump inlets and remove all debris, then plug pump back into the grounded (GFCI) outlet Do Not

" Disassemble the motor housing. This motor has NO repairable internal parts, and disassembly may cause leakage or dangerous electrical wiring issues. " Lift up the pump by the power cord. To clear a pump clogged with debris, first, UNPLUG PUMP from electrical power. Then, referring to the following picture, unscrew the stainless screws (5), and remove the volute (4),.use a flathead screwdriver to hold the shaft (1), then turn the impeller (2) counterclockwise to release the impeller (2). Remove debris from around the shaft (1) and on/under the impeller (2). Reassemble. Item Description Quantity 1 Shaft 1 2 Impeller 1 3 Gasket 1 4 Volute 1 5 Screw 9 Troubleshooting Problem Possible Cause Corrective Action Pump does not start or run Pump cannot pump water out 1. Blown fuse 2. Tripped breaker 3. Plug disconnected 4. Thermal overload 5. Corroded plug 6. Motor failed 1. Screen blocked 2. Hose kinked, bent sharply, or coiled 3. Airlock 4. Impeller loose on shaft 5. Impeller broken 1. Replace fuse 2. Reset breaker 3. Secure plug 4. Unplug the pump for 30 minutes, then plug in 5. Clean plug prongs 6. Call 877-278-2797 1. Clean screen 2. Straighten hose 3. Clean anti- airlock hole 4. Reassemble impeller 5. Call 877-278-2797

Warranty Limited Warranty For one (1) year from the date of purchase, AquaPro will repair or replace, at its option, for the original owner any parts of its filters ( Product ) which are found upon examination to be defective in materials or workmanship. This Limited Warranty covers parts only for a period of one (1) year. Please call 1-877-278-2797 for instructions. Be prepared to provide a receipt, the model number and serial number when exercising this limited warranty. Purchaser must pay all transportation charges on Products or parts submitted for repair or replacement. All non-warranty service charges are the responsibility of the original owner. Failure to pay for non-warranty service charges will void this Limited Warranty. This Limited Warranty does not cover Products that have been damaged as a result of accident, freezing, abuse, misuse, neglect, improper installation, improper maintenance or failure to operate in accordance with written instructions. All maintenance and service must be performed by service agents approved. Any unauthorized alteration or repairs will void this Limited Warranty. THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE (1) YEAR FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED. Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state. In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer s customers for such damages. This Limited Warranty does not include freight charges for equipment or component parts, to and from the factory, services such as maintenance or inspection, repair or damage due to negligence such as freezing conditions, incorrect installation, nor acts of God. The liability shall not exceed the repair or replacement of defective parts under this Limited Warranty. This Limited Warranty also does not include unnecessary service calls due to erroneous operational reports, external valve positions, or electrical service. If a non-warranty service call is made, and the homeowner is unwilling to pay for the service call, this Limited Warranty will be voided. This Limited Warranty is voided if the product is repaired or altered by any persons or agencies other than those authorized. This Limited warranty applies only within the continental USA. You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST present a copy of the purchase receipt at the time of service. Please call 1-877-278-2797 for service or return authorization and instructions. DO NOT MAIL THIS FORM. Use this form only to maintain your records.

MODEL NO. SERIAL NO. INSTALLATION DATE